Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

Similar documents
OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

Interfacing the 1724-Type Microprocessor-Controlled EDFA via a Serial Communication Port

TAS APFC Controller / Load Managers with MOD-BUS Interface

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS

Product Specification for model TT Transducer Tester Rev. B

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

METEOROLOGICAL INSTRUMENTS

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Stensat Transmitter Module

Instruction Sheet UPS SERIES. Serial Control Protocol. I Rev E

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

PowerPlex PowerPlex. DNP3 Interface Option Manual. June 15, 2010 ML0009 Document Revision C 2010 by Bitronics, LLC

ROTRONIC HygroClip Digital Input / Output

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP

DSTS-5A/2C User's Manual

Installation procedure Ground loop reader: LBS type R12 / RS232 type 5C

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A

4111 Usage Minutes 1 Integer RO Y - Minutes 0-59 Y Y YP

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

Stensat Radio Beacon

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

269 Troubleshooting Guide 11/4/98 1

Ocean Controls KT-5198 Dual Bidirectional DC Motor Speed Controller

Model ipm Intelligent Power Monitor

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE

Mastr III P25 Base Station Transmitter Tune-up Procedure

Microprocessor Control Board Set Up Procedures (OR PLC)

Back to. Communication Products Group. Technical Notes. Local/Remote Control, 9300 Series

Product Manual. 232-Amp+ 232-Amp+W. RS-232 Stereo Mixer/Amplifier Ver 2.3 July 19, 2016

2320 cousteau court

UART2PPM. User s Guide. Version 2.04 dated 02/20/16. Gregor Schlechtriem

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

Kelba (Australia) Pty Ltd. PA8101S Manual ~ TABLE OF CONTENTS

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing

EIG DNP V3.0 Protocol Assignments

g GE POWER MANAGEMENT

User manual. Inclinometer with Analog-RS232-Interface IK360

Energy Management Modular Power Analyzers Type WM2-96

Ocean Controls KT-5221 Modbus IO Module

EE 314 Spring 2003 Microprocessor Systems

Series PM130 PLUS Powermeters PM130P/PM130E/PM130EH

BV4112. Serial Micro stepping Motor Controller. Product specification. Dec V0.a. ByVac Page 1 of 18

Application Note Assigning and Reducing the DNP V3.0 Points List on the ABB PCD Timothy S. Fahey, PE

SERIES 3000 Kilowatt Hour Meter

Servo 8 Torque Board Doc V 1.2

Liquid Level Sensors. M-Series Magnetostrictive Sensors

Integrity Instruments

Parameter Value Unit Notes

WATT TRANSDUCER. Instruction Manual

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

ASX Series. High-Density AC Test Power Single and Three Phase Switchmode AC Power Sources. T h e P o w e r o f E x p e r t i s e.

TNM96-ETL Energy Meter & Electrical Powermeter

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

BPM214: Bidirectional Power Meter for WR-975 Waveguide

CMU232 User Manual Last Revised October 21, 2002

INSTRUMENTS, INC. INSTRUCTION MANUAL Precision 350 MHz Synthesizer. Model 425A. Table of Contents. Section Page Contents

RF Wireless Serial Device Server

Multi-Channel RS-232 Serial RF Transceiver

LC-10 Chipless TagReader v 2.0 August 2006

AMU-214 Auxiliary Monitor Unit Operations Manual

AMX Series. Precision AC Test Power Single and Three Phase Linear AC Power Sources. Parallelable to 30 kva. T h e P o w e r o f E x p e r t i s e

PI-150 Broadband Power Indicator

Power analyzers and Energy Meters Power Analyzer Type WM14-96

ELECTRICAL VARIABLE ANALYZER RELAY EVAR

Energy Management Energy Meter Type EM340

Fanuc Serial (RS232) Communications Information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

Quick-Start Guide. M7 Series DATA RADIO MODEM

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

LBI Installation & Operation

Digital Electric Micrometer. DEG2000 Instruction Manual

Energy Management Modular Power Quality Transducer Type PQT-90

The "FISH" Quad Hand Sensor

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T

PI-10 Broadband Power Indicator

I-7088, I-7088D, M-7088 and M-7088D User Manual

LAUREL ELECTRONICS, INC.

MultiComm & MultiComm RTH

Serial Servo Controller

Protective Relays Digitrip 3000

SUPPLY NETWORK ANALYZER CVM-96 SERIES

MultiComm. DNP3 Protocol Option Manual. June 15, 2010 ML0005 Document Revision C 2010 by Bitronics, LLC

TP4-WT4 Serial Communications Output Addendum

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION FEATURES APPLICATIONS

13. OP-03 RS-232C SERIAL INTERFACE

ALPHA Encoder / Decoder IC s

Energy Management Energy meters Type EM2-DIN

TLE ANALOG WEIGHT TRANSMITTER 4 20 ma, 0 20 ma, 0 10 V, 0 5 V, V, -5 5 V

SERIES PM172 POWERMETERS COMMUNICATIONS. DNP Communications Protocol REFERENCE GUIDE

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

Features Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ

Transcription:

digital ac POWER MONITOR DESCRIPTION The DSP is a three-phase, three-element multifunction digital transducer with outputs for voltage, current, and power via serial communication. Applications include 4-wire and 3-wire circuits with external current transformers where needed. Voltage and current ratings are programmable to obtain primary scaling. Measurements include: 3 line-to-line and line-to-neutral voltages, 3 currents, 3 perphase power, total power and frequency. All measurements are true RMS values. Data is available via a serial RS-422 port using a simple ASCII protocol. A PC data system and LabVIEW driver are available for programming and reading the DSP- 007 and DSP-008. Consult factory for free application software. Inputs Voltage (Line-Line/Line-Neutral) Current (secondary) Power measurement range Frequency Power Factor specifications Model DSP-007 300/175Vac 0-5 Amps 1-1000 W/element 48-62Hz 1.0-0.1 Lag and Lead Model DSP-008 600/345Vac 0-5 Amps 2-2000 W/element 48-62Hz 1.0-0.1 Lag and Lead Serial Communication Hardware... RS-422, 9-Pin D connector Parameters... 9600 Baud, 8 data bits, 1 stop bit, no parity Dielectric Test Input/Instrument Power to Output)...1000Vac Input/Instrument Power/Output to Case... 1500Vac Instrument Power Standard... 115Vac, ±10%, 50/60Hz, 5VA -22 Option... 230Vac, 50/60Hz, ±10% TEMPERATURE & PHYSICAL Temperature Effect...(-10ºC to 60ºC)...±0.005%/ºC Weight... 3.4 lbs. ORDERING INFORMATION Example: Three-Phase, Four-Wire, 480/277V, 5A, 60Hz with 230V Instrument Power. DSP-008-22 5 YEAR WARRANTY ACCURACY Volts, Amps... ±0.1% F.S. Power...(10%-100%)...±0.1% Rdg., ±0.05% F.S. Frequency... ±0.1%; ±0.1Hz Function Resolution Unit of measure Line-to-neutral RMS Volts, 3 phases 4 digits (XXX.X) Volts Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts Per-Phase Current, 3 phases 4 digits (XXXX) ma or Amps * Per-Phase Power 6 digits (XXXX.XX) Watts or kw * Total Power 6 digits (XXXX.XX) Watts or kw * Frequency (measured at L1-N) 4 digits (XXX.X) Hz Power Factor 3 digits (X.XX) PF *CT Rating is programmable by serial communication from 5-5000. If current units are in Amps, then Watt reading is kilowatts. If units are in milliamperes, then Watt reading is Watts ANALOG OUTPUT OPTION The model D/A-4653 is a 24Vdc-powered serial converter providing 8 channels of 4-20mAdc analog output. The converter connects to the serial port of a model DSP and converts the serial data to 4-20mAdc analog signals. Consult factory for details and pricing. Page 1 of 6 DSP Rev E.indd 1/14/09

digital ac POWER MONITOR CASE DIMENSIONS COMMUNICATIONS 7.31 0.25 0.25 1 5 6 9 3.50 1.50 7 8 9 1 2 10 11 1212a CASE HEIGHT 5.50" 3 4 All dimensions in inches 5 6 6a DIA 0.38 (2 PLCS) DIA 0.19 (4 PLCS) SIG +5V COM TX+ TX- RX+ RX- PIN 2 1 4 5 8 9 connection diagrams 1 2 3 4 5 6 6a 7 8 9 10 11 12 12a three-phase, FOUR-WIRE SYSTEM INST POWER LINE L1 L2 L3 N LOAD three-phase, THREE-WIRE SYSTEM (three CURRENT TRANSFORMERS) 1 2 3 4 5 6 6a 7 8 9 10 11 12 12a NOTE 1: Connection of device voltage neutral to system neutral is recommended but not required. In this configuration, all three phase currents are measured and individual phase power is dependent on system voltage balance if neutral is not connected. Total power accuracy is not dependent on voltage balance. L L1 L2 L3 1 L three-phase, THREE-WIRE SYSTEM (TWO CURRENT TRANSFORMERS) 1 2 3 4 5 6 6a 7 8 9 10 11 12 12a NOTE 1: Connection of device voltage neutral to system neutral is recommended but not required. In this configuration, all three phase currents are measured and individual phase power is dependent on system voltage balance if neutral is not connected. Total power accuracy is not dependent on voltage balance. L2 current is derived by this connection as L2 = -(L1+L3) LINE L1 L2 L3 NOTE 1 INST POWER LOAD Page 2 of 6 DSP Rev E.indd 1/14/09

ASCII COMMUNICATIONS Communication with the DSP is a simple ASCII protocol with defined commands and responses. Communication parameters are: 9600 Baud, 8 Bits, No Parity, 1 Stop Bit. MESSAGE FORMAT All commands and responses have the same general format: STX ADDR CMD [DATA] ETX STX An ASCII start-of-text control character, 02 Hex, control B, (^B). ADDR A meter s unique 4-character identification (address), most significant character first. only hexadecimal characters (0-9, A-F) are allowed. CMD A single character command for which there is a defined response. DATA Information associated with the command, where required. ETX An ASCII end-of-text control character, 03 Hex, control C, (^C). CR An ASCII carriage return character, 0D Hex. LF An ASCII line feed character, 0A Hex. A "broadcast address" of 0000 can be used in the ADDR field of certain commands. Refer to the specific command description for exact details on usage. Leading zeroes are not required in the DATA field except for the "W" command (change of unit address). Spaces that appear in the examples are only for the purpose of readability. Actual input strings and output response strings will not contain spaces. COMMANDS AND RESPONSES COMMAND: R Read Data stx ADDR R ETX RESPONSE: returns a string of characters with the values of the requested measured parameter. Response example: STX 0001, 600.3, 598.9, 599.2, 099.5, 100.0, 100.8, 3001.90, ETX Data fields in this example are: Address, VA-B, VB-C, VC-A, IA, IB, IC, KW The data fields returned are dependent on the defined read response setup (see U command & table on page 6). Will not respond if the broadcast address is used. Response example: STX 0001, 600.3, 598.9, 599.2, 099.5, 100.0, 100.8, 3001.90, F, ETX The "F" is added at the end of the string to indicate frozen readings. COMMAND: V Verify Settings stx ADDR V ETX RESPONSE: Returns a string of characters with the active values of all configurable parameters. Response example: STX 0001, 01.01, 0400, 2000, 02, F8, ETX Data fields in this example are: Address, Firmware version, VT rating, CT rating, A averaging, Read Setup byte. Instruments containing firmware version 4.02 or later will respond if the broadcast address is used. COMMAND: F Freeze Readings stx ADDR F ETX RESPONSE: stx F ETX (No response if broadcast address is used.) Upon receiving the next read command, the frozen readings are transmitted out with an "F" added at the end of the string to indicate frozen readings. Subsequent reads are not frozen until a new "Freeze" command is received. Page 3 of 6 DSP Rev E.indd 1/14/09

ASCII COMMUNICATIONS, Cont. COMMANDS AND RESPONSES, Cont. All of the remaining commands, unless otherwise noted, are disabled by a hardware lockout. Program parameters are stored in EEPROM non-volatile memory. To enable programming, connect a short length of wire (jumper) between terminal numbers 2 and 3. After setting needed parameters with the following commands, remove the jumper to lock out any further program changes. COMMAND: W Change Unit Address stx ADDROLD W NEW ADDRNEW ETX RESPONSE: STX W ETX (No response if broadcast address is used). Input example: STX 0001 W 0002 ETX (Changes unit address from 0001 to 0002.) Broadcast address can always be used to change the address setting. Any future communication must use either the new address or the broadcast address. COMMAND: K Change Averaging Cycles STX ADDR K XX ETX RESPONSE: STX K ETX (No response if broadcast address is used.) Input example: STX ADDR K 4 ETX (Defines the number of measurements averaged to be 4.) Broadcast address can be used to change the averaging cycles. COMMAND: 2 Change CT Rating stx ADDR 2 XXXX ETX RESPONSE: STX 2 ETX (No response if broadcast address is used.) Input example: STX ADDR 2 1000 ETX (Current range scale based on new value of 1000.) Broadcast address can be used to change the CT rating. COMMAND: J Change VT Rating stx ADDR J XXXX ETX RESPONSE: STX J ETX (No response if broadcast address is used.) Input example: STX ADDR J 600 ETX (Voltage range scale based on new value of 600.) Broadcast address can be used to change the VT rating. COMMAND: U Change Read Setup (Refer to Table 1, Read Control Setup Values) stx ADDR U XX ETX RESPONSE: STX U ETX (No response if broadcast address is used.) Input example: STX ADDR U F8 ETX The data in the "U" command example (F8) selects new read quantities. The most significant 6 bits (b7 b6 b5 b4 b3 b2) each correspond to a measured parameter. Set bit to a value of 1 to enable or 0 to disable. Bit selections are as shown in the table on page 6. Broadcast address can be used to change the read setup. Page 4 of 6 DSP Rev E.indd 1/14/09

ASCII COMMUNICATIONS, Cont. COMMANDS AND RESPONSES, Cont. The remaining commands are intended for use by factory technicians to implement calibration of the instrument. If recalibrated by the user, then the factory calibration will be changed. Calibration of measurements is accomplished by applying a fixed, stable source of Volts and Amps of required accuracy (such as a Rotek Model 800A, or equivalent). The DSP instrument is sent a command string which causes the applied inputs to be established as reference values for calculation of RMS Volts, Amps and Watts. Voltage measurements are referenced to line-to-neutral inputs. Generally the line-to-neutral input voltage applied for calibration is chosen to be the line-to-line voltage rating multiplied by 0.575. Example: If Vrating = 600 use 345, if 240 use 138, if 120 use 69, etc. Command: C1 Sets calibration to present value of input of phase "A" volts, amps and watts. stx ADDR C1 ETX Command: C2 Sets calibration to present value of input for phase "B" volts, amps and watts. stx ADDR C2 ETX Command: C3 Sets calibration to present value of input of phase "C" volts, amps and watts. stx ADDR C3 ETX Command: CA Sets calibration to present value of input for all three phases of volts, amps, and watts. stx ADDR CA ETX Command: CX Sets calibration to present value of voltage between phases A & B. Only voltage is calibrated. stx ADDR CX ETX Command: CY Sets calibration to present value of voltage between phases B & C. Only voltage is calibrated. stx ADDR CY ETX Command: CZ Sets calibration to present value of voltage between phases C & A. Only voltage is calibrated. stx ADDR CZ ETX Command: Q Read Calibration Constants stx ADDR Q ETX Response: stx ADDR LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR nnnnn LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN L lf CR NNNNN LF CR NNNNN ETX where the data fields represented by NNNNN are numerical values set by the calibration procedure. The broadcast address can't be used to read the calibration constants. Hardware lockout does not apply to this command. Page 5 of 6 DSP Rev E.indd 1/14/09

ASCII COMMUNICATIONS, Cont. U COMMAND Parameters Read Control Setup Values First Character Binary Hex V LL (3) V LN (3) I Ø (3) W Ø (3) Binary Hex W TOT F (Hz) PF 0000 0 0000 0 0001 1 X 0001 1 0010 2 X 0010 2 X 0011 3 X X 0011 3 X 0100 4 X 0100 4 X 0101 5 X X 0101 5 X 0110 6 X X 0110 6 X X 0111 7 X X X 0111 7 X X 1000 8 X 1000 8 X 1001 9 X X 1001 9 X 1010 A X X 1010 A X X 1011 B X X X 1011 B X X 1100 C X X 1100 C X X 1101 D X X X 1101 D X X 1110 E X X X 1110 E X X X 1111 F X X X X 1111 F X X X Table 1 An "X" in the field means that the parameter will be in the data string. Second Character Select the hexadecimal ("hex") digit for each of the two characters that represents the desired data string. Example: To put V LL, I Ø, W Ø, frequency and power factor in the data string, the binary sequence would be 10110110. The hexadecimal digits for the "U" command would therefore be B6. Page 6 of 6 DSP Rev E.indd 1/14/09