OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

Similar documents
Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

Interfacing the 1724-Type Microprocessor-Controlled EDFA via a Serial Communication Port

Stensat Transmitter Module

Instruction Sheet UPS SERIES. Serial Control Protocol. I Rev E

DSTS-5A/2C User's Manual

Precision Voltage Control System

TAS APFC Controller / Load Managers with MOD-BUS Interface

METEOROLOGICAL INSTRUMENTS

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP

METEOROLOGICAL INSTRUMENTS

PowerPlex PowerPlex. DNP3 Interface Option Manual. June 15, 2010 ML0009 Document Revision C 2010 by Bitronics, LLC

METEOROLOGICAL INSTRUMENTS

ROTRONIC HygroClip Digital Input / Output

Ocean Controls KT-5198 Dual Bidirectional DC Motor Speed Controller

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

4111 Usage Minutes 1 Integer RO Y - Minutes 0-59 Y Y YP

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE

Stensat Radio Beacon

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

269 Troubleshooting Guide 11/4/98 1

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

Product Specification for model TT Transducer Tester Rev. B

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

Energy Management Modular Power Analyzers Type WM2-96

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Installation procedure Ground loop reader: LBS type R12 / RS232 type 5C

EE 314 Spring 2003 Microprocessor Systems

Model ipm Intelligent Power Monitor

TECHNICAL NOTES MT-4 Radio Systems TN182 Battery Level Reporting and Remote P25 Test Tone

Integrity Instruments

Microprocessor Control Board Set Up Procedures (OR PLC)

WATT TRANSDUCER. Instruction Manual

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

HD 48V01T... HD 4977T...

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Mastr III P25 Base Station Transmitter Tune-up Procedure

INSTRUMENTS, INC. INSTRUCTION MANUAL Precision 350 MHz Synthesizer. Model 425A. Table of Contents. Section Page Contents

2320 cousteau court

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Kelba (Australia) Pty Ltd. PA8101S Manual ~ TABLE OF CONTENTS

Application Note Assigning and Reducing the DNP V3.0 Points List on the ABB PCD Timothy S. Fahey, PE

Liquid Level Sensors. M-Series Magnetostrictive Sensors

Back to. Communication Products Group. Technical Notes. Local/Remote Control, 9300 Series

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

EIG DNP V3.0 Protocol Assignments

User manual. Inclinometer with Analog-RS232-Interface IK360

Series PM130 PLUS Powermeters PM130P/PM130E/PM130EH

Product Manual. 232-Amp+ 232-Amp+W. RS-232 Stereo Mixer/Amplifier Ver 2.3 July 19, 2016

LAUREL ELECTRONICS, INC.

SERIES 3000 Kilowatt Hour Meter

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

MultiComm. DNP3 Protocol Option Manual. June 15, 2010 ML0005 Document Revision C 2010 by Bitronics, LLC

TNM96-ETL Energy Meter & Electrical Powermeter

Energy Management Energy meters Type EM2-DIN

Model A Milliohm Resistance Tester Operators Manual

METEOROLOGICAL INSTRUMENTS

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

Model 475 DSP Gaussmeter

Digital Electric Micrometer. DEG2000 Instruction Manual

Servo 8 Torque Board Doc V 1.2

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing

Energy Management Modular Power Quality Transducer Type PQT-90

UART2PPM. User s Guide. Version 2.04 dated 02/20/16. Gregor Schlechtriem

Energy Management Three-phase energy meter with output modules Type EM4-DIN

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

ASX Series. High-Density AC Test Power Single and Three Phase Switchmode AC Power Sources. T h e P o w e r o f E x p e r t i s e.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T

METEOROLOGICAL INSTRUMENTS

Parameter Value Unit Notes

I-7088, I-7088D, M-7088 and M-7088D User Manual

MultiComm & MultiComm RTH

SCM9B-D100 SERIES USERS MANUAL

2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions

Protocol and instruction set for remote control via the infrared interface. Table of Contents

The "FISH" Quad Hand Sensor

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

AMX Series. Precision AC Test Power Single and Three Phase Linear AC Power Sources. Parallelable to 30 kva. T h e P o w e r o f E x p e r t i s e

METEOROLOGICAL INSTRUMENTS

SERIES PM172 POWERMETERS COMMUNICATIONS. DNP Communications Protocol REFERENCE GUIDE

For Direct computer control see the Data Out connector description. For Radio control see the Data In connector description.

METEOROLOGICAL INSTRUMENTS

ELECTRICAL VARIABLE ANALYZER RELAY EVAR

BV4112. Serial Micro stepping Motor Controller. Product specification. Dec V0.a. ByVac Page 1 of 18

WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION FEATURES APPLICATIONS

DESIGNED BY THE BLACK TANK USER MANUAL

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

WIEG4PRT-A Four port Wiegand to RS232 Converter.

13. OP-03 RS-232C SERIAL INTERFACE

g GE POWER MANAGEMENT

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

WIE232-A Dual Wiegand to RS232 Converter.

PI-150 Broadband Power Indicator

Application Note. HAL 8xy, HAL 100x. Programmer Board

Transcription:

DIGITAL AC POWER MONITOR DESCRIPTION The DSP is a three-phase, three-element multifunction digital transducer with outputs for voltage, current, and power via serial communication. Applications include 4-wire and 3-wire circuits with external current transformers where needed. Voltage and current ratings are programmable to obtain primary scaling. Measurements include: 3 line-to-line and line-to-neutral voltages, 3 currents, 3 perphase power, total power and frequency. All measurements are true RMS values. Data is available via a serial RS-422 port using a simple ASCII protocol. A PC data system and LabVIEW driver are available for programming and reading the DSP- 007 and DSP-008. Consult factory for free application software. SPECIFICATIONS INPUTS 007 008 Voltage (Line-Line/Line-Neutral) 300/175Vac 600/345Vac Current (secondary) 0-5 Amps 0-5 Amps Power measurement range 1-1000 W/element 2-2000 W/element Frequency 48-62Hz 48-62Hz Power Factor 1.0-0.1 Lag and Lead 1.0-0.1 Lag and Lead SERIAL COMMUNICATION Hardware... RS-422, 9-Pin D connector Parameters... 9600 Baud, 8 data bits, 1 stop bit, no parity DIELECTRIC TEST Input/Instrument Power to Output)...1000Vac Input/Instrument Power/Output to Case... 1500Vac INSTRUMENT POWER Standard... 115Vac, ±10%, 50/60Hz, 5VA -22 Option... 230Vac, 50/60Hz, ±10% TEMPERATURE & PHYSICAL Temperature Effect...(-10ºC to 60ºC)...±0.005%/ºC Weight... 3.4 lbs. ORDERING INFORMATION Example: Three-Phase, Four-Wire, 480/277V, 5A, 60Hz with 230V Instrument Power. DSP-008-22 5 YEAR WARRANTY ACCURACY Volts, Amps... ±0.1% F.S. Power..(10%-100%)...±0.1% Rdg., ±0.05% F.S. Frequency... ±0.1%; ±0.1Hz FUNCTION RESOLUTION UNIT OF MEASURE Line-to-neutral RMS Volts, 3 phases 4 digits (XXX.X) Volts Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts Per-Phase Current, 3 phases 4 digits (XXXX) ma or Amps * Per-Phase Power 6 digits (XXXX.XX) Watts or kw * Total Power 6 digits (XXXX.XX) Watts or kw * Frequency (measured at L1-N) 4 digits (XXX.X) Hz Power Factor 3 digits (X.XX) PF *CT Rating is programmable by serial communication from 5-5000. If current units are in Amps, then Watt reading is kilowatts. If units are in milliamperes, then Watt reading is Watts ANALOG OUTPUT OPTION The model D/A-4653 is a 24Vdc-powered serial converter providing 8 channels of 4-20mAdc analog output. The converter connects to the serial port of a model DSP and converts the serial data to 4-20mAdc analog signals. Consult factory for details and pricing. DSP Rev F.indd Page 1 of 6

DIGITAL AC POWER MONITOR CASE DIMENSIONS COMMUNICATIONS CONNECTION DIAGRAMS THREE-PHASE, FOUR-WIRE SYSTEM THREE-PHASE, THREE-WIRE SYSTEM (THREE CURRENT TRANSFORMERS) NOTE 1: Connection of device voltage neutral to system neutral is recommended but not required. In this configuration, all three phase currents are measured and individual phase power is dependent on system voltage balance if neutral is not connected. Total power accuracy is not dependent on voltage balance. THREE-PHASE, THREE-WIRE SYSTEM (TWO CURRENT TRANSFORMERS) NOTE 1: Connection of device voltage neutral to system neutral is recommended but not required. In this configuration, all three phase currents are measured and individual phase power is dependent on system voltage balance if neutral is not connected. Total power accuracy is not dependent on voltage balance. L2 current is derived by this connection as L2 = -(L1+L3) DSP Rev F.indd Page 2 of 6

ASCII COMMUNICATIONS Communication with the DSP is a simple ASCII protocol with defi ned commands and responses. Communication parameters are: 9600 Baud, 8 Bits, No Parity, 1 Stop Bit. MESSAGE FORMAT All commands and responses have the same general format: STX ADDR CMD [DATA] ETX STX An ASCII start-of-text control character, 02 Hex, control B, (^B). ADDR A meter s unique 4-character identifi cation (address), most signifi cant character fi rst. Only hexadecimal characters (0-9, A-F) are allowed. CMD A single character command for which there is a defi ned response. DATA Information associated with the command, where required. ETX An ASCII end-of-text control character, 03 Hex, control C, (^C). CR An ASCII carriage return character, 0D Hex. LF An ASCII line feed character, 0A Hex. A "broadcast address" of 0000 can be used in the ADDR fi eld of certain commands. Refer to the specifi c command description for exact details on usage. Leading zeroes are not required in the DATA fi eld except for the "W" command (change of unit address). Spaces that appear in the examples are only for the purpose of readability. Actual input strings and output response strings will not contain spaces. COMMANDS AND RESPONSES COMMAND: R Read Data STX ADDR R ETX RESPONSE: Returns a string of characters with the values of the requested measured parameter. Response example: STX 0001, 600.3, 598.9, 599.2, 099.5, 100.0, 100.8, 3001.90, ETX Data fi elds in this example are: Address, VA-B, VB-C, VC-A, IA, IB, IC, KW The data fi elds returned are dependent on the defi ned read response setup (see U command & table on page 6). Will not respond if the broadcast address is used. Response example: STX 0001, 600.3, 598.9, 599.2, 099.5, 100.0, 100.8, 3001.90, F, ETX The "F" is added at the end of the string to indicate frozen readings. COMMAND: V Verify Settings STX ADDR V ETX RESPONSE: Returns a string of characters with the active values of all confi gurable parameters. Response example: STX 0001, 01.01, 0400, 2000, 02, F8, ETX Data fi elds in this example are: Address, Firmware version, VT rating, CT rating, Averaging, Read Setup byte. Instruments containing fi rmware version 4.02 or later will respond if the broadcast address is used. COMMAND: F Freeze Readings STX ADDR F ETX RESPONSE: STX F ETX (No response if broadcast address is used.) Upon receiving the next read command, the frozen readings are transmitted out with an "F" added at the end of the string to indicate frozen readings. Subsequent reads are not frozen until a new "Freeze" command is received. DSP Rev F.indd Page 3 of 6

ASCII COMMUNICATIONS, CONT. COMMANDS AND RESPONSES, CONT. All of the remaining commands, unless otherwise noted, are disabled by a hardware lockout. Program parameters are stored in EEPROM non-volatile memory. To enable programming, connect a short length of wire (jumper) between terminal numbers 2 and 3. After setting needed parameters with the following commands, remove the jumper to lock out any further program changes. COMMAND: W Change Unit Address STX ADDROLD W NEW ADDRNEW ETX RESPONSE: STX W ETX (No response if broadcast address is used). Input example: STX 0001 W 0002 ETX (Changes unit address from 0001 to 0002.) Broadcast address can always be used to change the address setting. Any future communication must use either the new address or the broadcast address. COMMAND: K Change Averaging Cycles STX ADDR K XX ETX RESPONSE: STX K ETX (No response if broadcast address is used.) Input example: STX ADDR K 4 ETX (Defi nes the number of measurements averaged to be 4.) Broadcast address can be used to change the averaging cycles. COMMAND: 2 Change CT Rating STX ADDR 2 XXXX ETX RESPONSE: STX 2 ETX (No response if broadcast address is used.) Input example: STX ADDR 2 1000 ETX (Current range scale based on new value of 1000.) Broadcast address can be used to change the CT rating. COMMAND: J Change VT Rating STX ADDR J XXXX ETX RESPONSE: STX J ETX (No response if broadcast address is used.) Input example: STX ADDR J 600 ETX (Voltage range scale based on new value of 600.) Broadcast address can be used to change the VT rating. COMMAND: U Change Read Setup (Refer to Table 1, Read Control Setup Values) STX ADDR U XX ETX RESPONSE: STX U ETX (No response if broadcast address is used.) Input example: STX ADDR U F8 ETX The data in the "U" command example (F8) selects new read quantities. The most signifi cant 6 bits (b7 b6 b5 b4 b3 b2) each correspond to a measured parameter. Set bit to a value of 1 to enable or 0 to disable. Bit selections are as shown in the table on page 6. Broadcast address can be used to change the read setup. DSP Rev F.indd Page 4 of 6

ASCII COMMUNICATIONS, CONT. COMMANDS AND RESPONSES, CONT. The remaining commands are intended for use by factory technicians to implement calibration of the instrument. If recalibrated by the user, then the factory calibration will be changed. Calibration of measurements is accomplished by applying a fi xed, stable source of Volts and Amps of required accuracy (such as a Rotek Model 800A, or equivalent). The DSP instrument is sent a command string which causes the applied inputs to be established as reference values for calculation of RMS Volts, Amps and Watts. Voltage measurements are referenced to line-to-neutral inputs. Generally the line-to-neutral input voltage applied for calibration is chosen to be the line-to-line voltage rating multiplied by 0.575. Example: If Vrating = 600 use 345, if 240 use 138, if 120 use 69, etc. COMMAND: C1 Sets calibration to present value of input of phase "A" volts, amps and watts. STX ADDR C1 ETX COMMAND: C2 Sets calibration to present value of input for phase "B" volts, amps and watts. STX ADDR C2 ETX COMMAND: C3 Sets calibration to present value of input of phase "C" volts, amps and watts. STX ADDR C3 ETX COMMAND: CA Sets calibration to present value of input for all three phases of volts, amps, and watts. STX ADDR CA ETX COMMAND: CX Sets calibration to present value of voltage between phases A & B. Only voltage is calibrated. STX ADDR CX ETX COMMAND: CY Sets calibration to present value of voltage between phases B & C. Only voltage is calibrated. STX ADDR CY ETX COMMAND: CZ Sets calibration to present value of voltage between phases C & A. Only voltage is calibrated. STX ADDR CZ ETX COMMAND: Q Read Calibration Constants STX ADDR Q ETX RESPONSE: STX ADDR LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN LF CR NNNNN ETX where the data fi elds represented by NNNNN are numerical values set by the calibration procedure. The broadcast address can't be used to read the calibration constants. Hardware lockout does not apply to this command. DSP Rev F.indd Page 5 of 6

ASCII COMMUNICATIONS, Cont. U COMMAND Parameters MODEL dsp- Read Control Setup Values First Character Binary Hex V LL (3) V LN (3) I Ø (3) W Ø (3) Binary Hex W TOT F (Hz) PF 0000 0 0000 0 0001 1 X 0001 1 0010 2 X 0010 2 X 0011 3 X X 0011 3 X 0100 4 X 0100 4 X 0101 5 X X 0101 5 X 0110 6 X X 0110 6 X X 0111 7 X X X 0111 7 X X 1000 8 X 1000 8 X 1001 9 X X 1001 9 X 1010 A X X 1010 A X X 1011 B X X X 1011 B X X 1100 C X X 1100 C X X 1101 D X X X 1101 D X X 1110 E X X X 1110 E X X X 1111 F X X X X 1111 F X X X Table 1 An "X" in the field means that the parameter will be in the data string. Second Character Select the hexadecimal ("hex") digit for each of the two characters that represents the desired data string. Example: To put V LL, I Ø, W Ø, frequency and power factor in the data string, the binary sequence would be 10110110. The hexadecimal digits for the "U" command would therefore be B6. 4242 reynolds drive * hilliard, ohio * 43026-1264 DSP Rev F.indd Page 6 of 6