the 3500/44M Aeroderivitive GT Vibration Monitor for the

Similar documents
3500/64M Dynamic Pressure Monitor

3500/40M Proximitor Monitor

Trendmaster * Dynamic Scanning Module

1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input

High Temperature Velocity and Acceleration Sensor

Low Frequency Velocity Sensor

TK-3 Proximity System Test Kit

Underwater Probes. Bently Nevada* Asset Condition Monitoring. Description

A6500-UM Universal Measurement Card

Shaft Absolute Vibration Monitor Specifications

protim-r Module

protim-c Module Bently Nevada* Asset Condition Monitoring

Speed and Key Monitor Specifications

Electrodynamic Velocity Sensor

Описание на пьезодатчики скорости. Модель

ADRE for Windows / DAIU

protim-r Module

SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL

Описание на модули интерфейса управления. Модель 1701/22

CEC VIBRATION TRANSMITTER

Underwater Probes. Description

MTN/8066/G-MAC VIBRATION MODULE

Vibration amplifier Model 6634C

ADAPT 3701/44 Aeroderivative Monitor Bently Nevada* Asset Condition Monitoring

4-20 ma Vibration Transmitter, Top connector

ADAPT* 3701/46 Hydro Monitor

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

Description. The vb8 offers the following features: Triax-enabled. 12,800 lines FFT resolution. Supports 80 khz Fmax. 1 GB memory

CSI 9330 Vibration Transmitter

Accutech AM20. Wireless acoustic monitor field unit

Fisher 646 Electro Pneumatic Transducer

PV 102. IECEx. Piezoelectric velocity sensor FEATURES. From the Vibro-Meter product line

Instruction Manual. Charge Amplifiers. M68 Series. Manfred Weber

Piezotron Coupler. Electronics & Software. Acoustic Emission Coupler for Safe or Hazardous Locations ATEX/IEC/Ex and CSA. Type 5125C...

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

XM Monitoring Modules Specifications

9330 Vibration Transmitter

1443 Series Accelerometers Specifications

Operating Manual. isolate501

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

vb8 Product Datasheet Bently Nevada* Asset Condition Monitoring

Unstable Reading of Accelerometers in Cryogenic Service. Cryodynamics Division

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Isolators A3/1. Vibration Transducer Supply Unit Series

Fisher 646 Electro-Pneumatic Transducers

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Temperature Input Module for Zone 1 Series 9482/32

ADAPT* 3701/46 Hydro Monitor

Condition Monitoring Custom Products

ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet

IPC 704. Signal conditioner FEATURES. For CA piezoelectric accelerometers and CP dynamic pressure transducers

Product Specifications

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

General Specifications

Submersible pressure sensor For superior applications Model LF-1

X20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622

IP26 Series Current to Pneumatic Converter

Digital Input Output Module for Zone 2 Series 9470/33

DeltaV SIS Logic Solver

Applications Note. Bently Nevada* Asset Condition Monitoring. Periodically Monitored Assets. Connecting SCOUT to Continuous Monitoring Systems

Product Specifications

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model 3102D 0-2 kv H.V. Power Supply

Power Supplies 3. SDN-C Compact DIN Rail Series

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Analog Universal Module HART for Zone 2 Series 9468/33

8588A Reference Multimeter

Two-channel safety barriers Series 9002

3300/20 Dual Thrust Position Monitor

1-830 SERIES DISPLACEMENT TRANSMITTER

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

Proximity Transmitters and Seismic Vibration Transmitters

Part Number Revision NC, May Low Frequency Velocity Sensor Operation and Maintenance Manual

Two-channel safety barriers Series 9002

AMS 9420 Wireless Vibration Transmitter

SKF Multilog On-line System DMx

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation

SDN-C Single and three phase power supplies Product Guide

Signal Conditioning Amplifier

MINI MCR-SL-UI-I-LP-NC

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Signal Conditioning Amplifier

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants

Fisher 4200 Series Electronic Position Transmitters

Racal Instruments 4152A. 6.5 Digit Digital Multimeter. Product Information

CSI 9420 Wireless Vibration Transmitter

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

SKF Multilog On-line System DMx

INTER PLANT STANDARD STEEL INDUSTRY

LST100 Ultrasonic level transmitter for upstream oil and gas

IT6810/IT6811/IT6812 IMPACT TRANSMITTER Installation Manual

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Accutech DP20. Wireless differential pressure field unit

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transcription:

3500/44M Aeroderivitive GT Vibration Monitor Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 3500/44M Aeroderivitive GT Vibration Monitor is a fourchannel instrument designed for aeroderivative gas turbine applications. The Aero GT I/O modules interface to velocity transducers through Bently Nevada* interface modules, part numbers 86517 and 86497. The monitor uses the Prox/Velom I/O to interface to our Velomitor* sensors and accelerometers. Using the 3500 Rack Configuration Software, you can configure the 3500/44M Aeroderivitive GT Vibration Monitor for the following filter options: Signal Integration 1X vibration tracking Band-pass vibration The 3500/44M Aeroderivitive GT Vibration Monitor accepts input from two separate Keyphasor* signals, allowing each channel pair to use a different tracking filter. The 3500/44M Aeroderivitive GT Vibration Monitor meets the recommended requirements of the following aeroderivative gas turbine manufacturers: Rolls Royce: RB211, Avon General Electric: LM1600, LM2500, LM5000, LM6000 United Technologies: Turbo Power GG 3, G44, FT 4, FT 8 The primary purpose of the 3500/44M Aeroderivitive GT Vibration Monitor is to provide the following: Machinery protection by continuously comparing monitored parameters against configured alarm setpoints to drive alarms Essential machine information for both operations and maintenance personnel You can configure multimode channels to have up to eight sets of alarm parameters including alert and danger setpoints and Page 1 of 12

alarm time delays. Each set may be configured for a specific machine mode. As the machine changes modes, the monitor can switch to a specific set using contacts on multimode I/O modules or software commands through a communications gateway. Page 2 of 12

Specifications Inputs Signal Power consumption Aero GT I/O Prox/Velom I/O and Multimode Prox/Velom I/O Sensitivity Aeroderivative Aeroderivative2 and Multimode Aeroderivative Accepts 1 to 4 signals from interface modules (part numbers 86517 and 86497), velomitors and accelerometers 7.7 watts, typical Input Impedance Greater than 95 kω (Proximitor and acceleration inputs) 10 kω for Prox/Accel 3.5 MΩ for Velomitor 3.94 mv/(mm/s) (100mV/(in/s)) or 5.71 mv/(mm/s) (145mV/(in/s)) 3.94 mv/(mm/s) (100mV/(in/s)), 5.71 mv/(mm/s) (145mV/(in/s)), 10.19 mv/(m/s2) (100 mv/g), 2.55 mv/(m/s2) (25 mv/g) or 1.02 mv/(m/s2) (10 mv/g) Outputs OK LED TX/RX LED Bypass LED Buffered Transducer Outputs Output Impedance Transducer Power Supply Recorder Voltage Compliance (current output) Resolution Front Panel LEDs Indicates when the 3500/44M Aeroderivitive GT Vibration Monitor is operating properly. Indicates when the 3500/44M Aeroderivitive GT Vibration Monitor is communicating with other modules in the 3500 Rack. Indicates when the 3500/44M Aeroderivitive GT Vibration Monitor is in Bypass Mode. The front of each monitor has one coaxial connector for each channel. Each connector is short-circuit protected. 550 Ω -23 Vdc nominal at 43 ma max +4 to +20 ma Output is proportional to monitor full-scale. One output is provided for each channel. Monitor operation is unaffected by short circuits on recorder outputs. 0 to +12 Vdc range across load Load resistance is 0 to 600 Ω. 0.3662 µa per bit ±0.25% error at room temperature ±0.7% error over temperature range Update rate 100 ms or less Page 3 of 12

Signal Conditioning Specified at +25 ºC (+77 ºF) unless otherwise noted. Aeroderivative Accuracy Direct signal Low-pass corner Low-pass rolloff High-pass corner High-pass rolloff Tracking filter Constant Q Rolloff Within ±0.33% of full-scale typical ±1% maximum Exclusive of filters Frequency Response 4 Hz to 30 khz, -3 db Direct Signal - Bandpass Filter 200 Hz (-3 db) 10-pole 200 db per decade 60 db per octave 25, 75 or 100 Hz (-3 db) 10-pole 200 db per decade 60 db per octave Direct Signal - Tracking Filter Valid for machine speeds of 60 to 240,000 cpm User-configurable by selecting one of 22 normal operating speeds from 2,400 to 18,000 RPM and by bandwidth of 3 or 5Hz 6-pole 120 db per decade 36 db per octave Aeroderivative2 and Multimode Aeroderivative Accuracy Non-integrated velocity Integrated velocity Non-integrated acceleration Integrated acceleration Bias low-pass filter Low-pass cutoff frequency Low-pass rolloff High-pass cutoff frequency High-pass rolloff Within ±0.33% of full-scale typical ±1% maximum Exclusive of filters Frequency Response Direct Signal - Bandpass Filter 4 Hz to 5500 Hz (-3 db) 18 Hz to 5500 Hz (-3 db) 4 Hz to 30,000 Hz (-3 db) 18 Hz to 14,500 Hz (-3 db) 0.01 Hz (-3 db) Bandpass Filter Configurable between 100 Hz and 5500 Hz (-3 db) 8-pole 160 db per decade 48 db per octave Configurable between 10 Hz and 1000 Hz (-3 db) 8-pole 160 db per decade 48 db per octave Tracking filter Constant Q Rolloff Tracking filter is valid for machine speeds of 60 to 300,000 cpm Tracking Filter User configurable You can select one of 35 normal operating speeds from 2,400 to 30,000 RPM and bandwidth of 3 or 5 Hz. 6-pole 120 db per decade 36 db per octave Page 4 of 12

Alarms Alarm setpoints Alarm accuracy Aeroderivative Aeroderivative2 Multimode Aeroderivative Alarm Time Delays Alert Danger You can set Alert levels for various values measured by the monitor and Danger setpoints for up to two of the values measured by the monitor using configuration software. Alarms are adjustable from 0 to 100% of full-scale for each measured value except when the full-scale range exceeds the range of the transducer. In this case, the range of the transducer will limit the setpoint. Within 0.13% of the desired value Direct 1X Amplitude Bandpass Direct Bandpass 1X Amplitude 1X Phase Lag Direct Direct-B Bandpass Bandpass-B 1X Ampl 1X Ampl-B 1X Phase Lag For Aeroderivative channels, you can set one alert and one danger delay for each channel. For Aeroderivative2 and Multimode Aeroderivative channels, you can set delays for each proportional value having alarm setpoints. From 1 to 60 seconds in 1 second intervals 0.1 seconds or from 1 to 60 seconds in 1 second intervals Proportional Values Proportional values are measurements used to monitor the machine. The 3500/44M Aeroderivitive GT Vibration Monitor provides the following proportional values: Aeroderivative Aeroderivative2 Multimode Aeroderivative Physical Dimensions (Height x Width x Depth) Weight Dimensions (Height x Width x Depth) Weight Direct 1X Amplitude Bandpass Direct Bandpass Bias 1X Amplitude 1X Phase Lag Direct Direct-B Bandpass Bandpass-B 1X Ampl 1X Ampl-B 1X Phase Lag Mode Monitor Module (Main Board) 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) 0.91 kg (2.0 lb) I/O Modules 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) 0.45 kg (1.0 lb) Rack Space Requirements Monitor Module I/O Modules 1 full-height front slot 1 full-height rear slot Page 5 of 12

Hazardous Area Approvals For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide, document 108M1756, at www.gemeasurement.com. CSA/NRTL/C (Approval Option 01) Ex nc [ia] IIC T4 Gc Class I, Division 1, Groups A, B, C and D Environmental Limits Operating Temperature Storage Temperature Humidity -30 C to +65 C (-22 F to +149 F) -40 C to +85 C (-40 F to +185 F) 95% Non-condensing Compliance and Certifications When used with I/O module ordering options and internal barriers When used with I/O module ordering options without internal barriers Class I, Zone 2/0 AEx nc [ia] IIC T4 Gc Class I, Division 1 Groups A, B, C and D T4 @ -20 C Ta +65 C (-4 F to +149 F) per drawing 138547 nc [L] IIC T4 Gc Class I, Division 2, Groups A, B, C and D Class I, Zone 2 AEx nc IIC T4 Gc Class I, Division 2 Groups A, B, C and D T4 @ -20 C Ta +65 C (-4 F to +149 F) per drawing 149243 ATEX/IECEx (Approval Option 02) EMC Electrical Safety Standards: EN 61000-6-2 Immunity for Industrial Environments EN 61000-6-4 Emissions for Industrial Environments European Community Directives: EMC Directive 2014/30/EU Standards: EN 61010-1 European Community Directives: LV Directive 2014/35/EU For ATEX/IECEx agency approval ordering options with internal barriers II 3 (1) G Ex na nc ic [ia Ga] IIC T4 Gc T4 @ -20 C Ta +65 C (-4 F to +149 F) For ATEX/IECEx agency approval ordering options without internal barriers II 3 G Ex na nc ic IIC T4 Gc T4 @ -20 C Ta +65 C (-4 F to +149 F) Page 6 of 12

Ordering Information For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide, document 108M1756, at www.gemeasurement.com. Aeroderivative Monitor 3500/44 - AXX - BXX A: I/O Module Type 01 Aero GT I/O Module with Internal 02 Aero GT I/O Module with External 05 Prox/Velom I/O Module with Internal 06 Prox/Velom I/O Module with External 07 Multimode Prox/Velom I/O Module with Internal 08 Multimode Prox/Velom I/O Module with External B: Agency Approval 00 None 01 CSA / NRTL / C (Class I, Division 2) 02 ATEX / IECEx / CSA (Class I, Zone 2) External Termination Blocks 125808-03 125808-08 125808-11 125808-13 128702-01 128015-03 128015-08 128015-11 128015-13 128710-01 Aeroderivative ET Block Euro Style Connectors Prox/Velom External Termination Block Euro Style connectors Multimode Prox/Velom External Termination Block Euro Style connectors Multimode Recorder Output and Mode Input External Termination Block Euro Style connectors Recorder External Termination Block Euro Style connectors Aeroderivative External Termination Block Terminal Strip Connectors Prox/Velom External Termination Block Terminal Strip Connectors Multimode Prox/Velom External Termination Block Terminal Strip connectors Multimode Recorder Output and Mode Input External Termination Block Terminal Strip connectors Recorder External ET Block Terminal Strip connectors Page 7 of 12

Cables 3500 Transducer (XDCR) to External Termination (ET) Block Cable 129525 - AXXXX - BXX A: I/O Cable length 0005 5 feet (1.5 metres) 0007 7 feet (2.1 metres) 0010 10 feet (3.0 metres) 0025 25 feet (7.6 metres) 0050 50 feet (15.2 metres) 0100 100 feet (30.5 metres) B: Assembly instructions 01 Not assembled 02 Assembled 3500 Recorder Output to External Termination (ET) Block Cable 129529 - AXXXX - BXX A: I/O Cable length 0005 5 feet (1.5 metres) 0007 7 feet (2.1 metres) 0010 10 feet (3.0 metres) 0025 25 feet (7.6 metres) 0050 50 feet (15.2 metres) 0100 100 feet (30.5 metres) B: Assembly instructions 01 Not assembled 02 Assembled Spares 176449-03 143490-01 126599-01 140471-01 140482-01 169459-01 169459-02 00580434 00580432 00561941 3500/44M Aeroderivitive GT Vibration Monitor 3500/44M Aeroderivitive GT Vibration Monitor Manual Aero GT I/O Module Internal Prox/Velom I/O Module with Internal Prox/Velom I/O Module with External Multimode Prox/Velom I/O Module with Internal Multimode Prox/Velom I/O Module with External Euro Style connector header 8 pin Green For use on I/O modules with internal terminations Euro Style connector header 10 pin Green For use on I/O modules with internal terminations Prox/Velom and Multimode Prox/Velom I/O Module ten-pin connector shunt Page 8 of 12

Graphs and Figures This section includes the following graphs and figures: Front and rear views of the 3500/44M Aeroderivitive GT Vibration Monitor See Front and Rear Views of the 3500/44M Aeroderivitive GT Vibration Monitor on page 10. The side view of the Prox/Velom I/O and Multimode Prox/Velom I/O with internal and external terminations See Side View of I/O Modules on page 11. Page 9 of 12

Front and Rear Views of the 3500/44M Aeroderivitive GT Vibration Monitor 1: Status LEDs 2: Buffered Transducer Outputs 3: 3500/44M Aeroderivitive GT Vibration Monitor Main Module 4: Aero GT I/O Module with Internal 5: Aero GT I/O Module with External 6: Prox/Velom I/O, Internal 7: Prox/Velom I/O, External 8: Multimode Prox/Velom I/O, Internal 9: Multimode Prox/Velom I/O, External Page 10 of 12

Side View of I/O Modules Prox/Velom I/O modules and Multimode Prox/Velom I/O modules with internal and external terminations have the same jumpers. Page 11 of 12

1999-2017 Bently Nevada LLC All rights reserved. * Denotes a trademark of Bently Nevada LLC, a wholly owned subsidiary of General Electric Company. All product and company names are trademarks of their respective holders. Use of the trademarks does not imply any affiliation with or endorsement by the respective holders. The information contained in this document is subject to change without prior notice. Printed in USA. Uncontrolled when transmitted electronically. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 1-775.782.3611 www.gemeasurement.com Page 12 of 12