S-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS

Similar documents
ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

Infrared Carbon Dioxide Gas Module ( single beam )

QPM Series Indoor Air Quality Duct Sensors

The MiCS-VZ-87 is an integrated sensor board for Indoor Air Quality monitoring.

ULPSM-RESPIRR

Particle / Dust Sensor Module

The MiCS-VZ-87 is an integrated sensor board for Indoor Air Quality monitoring.

The MiCS-VZ-89TE is an integrated sensor board for Indoor Air Quality monitoring.

Room air quality sensors

Driesen + Kern GmbH. Product Specification. SenseAir S8. Commercial. Miniature infrared CO 2 sensor module. Document Rev Page 1 (10)

Driesen + Kern GmbH. Product Specification. SenseAir S8. Miniature CO 2 sensor. Document PSP 113. Rev 3. Page 1 (12)

Product Specification SenseAir S8

Subminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc.

Infrared Carbon Dioxide Sensor Module CM1108-Dual Beam

Intelligent Infrared CO2 Module (Model: MH-Z19)

Senseair S8 Commercial

CO2 OR HYDROCARBONS INFRARED SENSOR WITH INTEGRATED TRANSMITTER

Infrared Carbon Dioxide Sensor Module CM1106-Single Beam

Product Specification. SenseAir S8 LP. Miniature infrared CO 2 sensor module. Document PSP 126. Rev 4. Page 1 (10)

Gas and Air Sensors. Product Specification. SenseAir. Miniature CO2 sensor

ULPSM-Ethanol

SenseAir S8 Miniature infrared CO 2 sensor module

Intelligent Infrared CO2 Module (Model: MH-Z19B)

Ultra-Low Power Analog Sensor Module for Sulfur Dioxide

Data sheet and manual. SenseAir S8. Alarm 5% Miniature infrared CO 2 sensor module

The MiCS-VZ-89TE is an integrated sensor board for Indoor Air Quality monitoring.

Infrared Carbon Dioxide Sensor Module CM1106-Single Beam

Warning! ESD sensitive device!

ULPSM-NO August 2017

OPUS20 Multiple Functions with Internal Sensors

Product Specification. SenseAir S8 LP. Miniature infrared CO 2 sensor module. Document PSP 126. Rev 8. Page 1 (8)

PolyGard Digital Transmitter DGC DT-02

S8 Residential pin header

Gas and Air Sensors. Product Specification. SenseAir S8. Miniature CO2 sensor. Document PSP 107. Rev 8. Page 1 (10)

Gas and Air Sensors. Product Specification. SenseAir S8. Miniature CO 2 sensor module

R S / R 100ppb 0.1. Fig. 1: R S /R 0 as a function of gas concentration at 50% RH and 25 C.

Driesen + Kern GmbH. SenseAir S8

PM2.5 / PM1.0 Sensor Particulate Matter Sensing Solution

Carbon Dioxide Sensor for the LogIT Microsense system

CO2 Engine - ICB Sensor module for bio applications

Air Quality Sensor KNX AQS

ZG07 CO2 Module. ZG07 series CO2 Module. User Manual

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14)

DG5000 Series Specifications

USERS MANUAL. Infrared Carbon Dioxide Module CM1102(Dual Beam With T&RH) V1.20. Wuhan Cubic Optoelectronics Co.,Ltd

OPUS20 LAN-Datalogger Future Inside

Gases 1.0. Technical Guide. wasp

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

made in finland product catalogue

VENTI-LIGHT VLD. Ventilatie Indicator G e b r u i k e r s h a n d l e i d i n g. Ampèrestraat NL-1446 TR PURMEREND

SPECIFICATION. Product Name: Dust Sensor DS1705A. Product Data Sheet. Review Check Approve. Technology Quality Supplier

RSMFX-2R MULTIFUNCTIONAL

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.

Technical data sheet TDS0037

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

PDSM010 Particle Sensor Module

RH/RHT Series. Relative Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies. Features

INTRODUCTION Laser Particle Sensor Module PM2007

ALPHASENSE USER MANUAL. Toxic Sensor Evaluation Board Issue 4

Symaro portfolio overview

DG4000 Series Waveform Generators

Flexible AC current probes

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

AR1000 DATASHEET v0.1

Technical data sheet TDS0058

Technical Information for the CDM7160 CO2 Module

NITROGEN DIOXIDE NO2 SS SOLID ELECTROCHEMICAL SENSOR

Technical Data Sheet

Dual thermopile sensor with two spectral filters for gas detection

OJ Air Pressure VENTILATION CONTROLLERS AND PRESSURE TRANSMITTERS. full-range pressure and ventilation control HVAC CONTROLS & POWER

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

NDIR TYPE INFRARED GAS ANALYZER

an ISO9001 company TECHNICAL INFORMATION FOR TGS8100 Technical Information for Air Quality Control Sensors

Symaro portfolio overview. Answers for infrastructure and cities.

Wireless CO 2. + TRH Sensor. Installation Guide. Version 1

Data Sheet. Function/Arbitrary Waveform Generator. Application fields: Edit arbitrary waveform. Reasonable price & outstanding.

Laser Particle Sensor Module PM2006M

Characteristics. Frequency (DG1022) Sine, Square, Ramp, Triangle, Pulse, Noise, Arb. ±50 ppm in 90 days ±100 ppm in 1year 18 C ~ 28 C.

CALYS 150. Advanced documenting multifunction calibrator thermometer

DATASHEET SMT172. Features and Highlights. Application. Introduction

Wall Mounted E-BUS CO 2. Sensor Technical Guide

Specifications for DS1000CA Series

General Specifications

Laser Particle Sensor Module PM2105

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

Diode Laser Systems In Gas Measurement

DATASHEET. SMT172 Preliminary. Features and Highlights. Application. Introduction

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Series 10-ZSE30A(F)/10-ISE30A

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Track Circuit Systems Products

APPENDIX APPENDIX A 1

CALYS 50. Field multifunction calibrator for basic use

Two-Wire Programmable Transmitter for:

SGAS707 Datasheet. Industrial Organic Chemical Sensor. Description. Features. Typical Applications. Examples of Target Gases.

WIRELESS BASE STATION WIRELESS CONFIGURATION TOOL WIRELESS REPEATER

Technical data sheet TDS0074

Maintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation

Transcription:

S-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS

2 AERECO Sensor range INDOOR AIR QUALITY, A QUESTION OF BALANCE Most of the new constructions in developed countries have high air tightness which induces a potential risk of bad indoor air quality in case of lack of ventilation. Good air quality is necessary to maintain all human faculties and to prevent the building from damaging. Indoor air quality is also a major parameter for people s comfort, concentration, and productivity. Ventilation, which consists in replacing the stale air by new clean air, remains the most efficient solution to manage indoor air quality. ENABLE SMART BUILDING MANAGEMENT C0 2 With the numerous rooms in tertiary buildings, it is difficult for operation staff to remain fully aware of the indoor air and system conditions. BMS (Building Management System) that includes reliable components can efficiently help improving the comfort and security for the occupants, while increasing energy efficiency. An excessive CO 2 concentration can negatively impact on indoor air quality and on people s comfort. Aereco introduces its new range of sensors to measure the concentrations of CO 2, VOCs and humidity and to control your building s HVAC system (Heating, Ventilation, Air conditionning, etc.). Fully calibrated, the three sensors can be easily integrated to your HVAC system to guarantee a smart and simple building management. Main impacts of CO 2 absolute concentration on human health

AERECO Sensor range 3 VOCs VOCs, invisible particles present in the air that can impact on people s health. Volatile organic compounds (VOCs) are also air quality index. People breath VOCs as well as CO 2 as they are naturally present in the air. VOCs are not only emitted by human metabolism (human breathing and perspiration) but also by indoor environment (building materials, cleaners, paints ). Some of them can directly affect the health and the comfort of the occupants. INDOOR HUMIDITY Preventing from excess of humidity to improve people s comfort and avoid building damages. Humidity in some rooms of a building can be generated by people (perspiration, breathing, sport activity), and humid areas such as lavatories, showers, etc. If not controlled in the rooms where its rate can rise to high levels, moisture and condensation will begin to appear and people s health can be impacted (respiratory problems, cold, etc.). That is why it is necessary to reliably measure the relative humidity of the rooms and then adapt the ventilation system. Main VOC particles present in the indoor air Optimum relative humidity for indoor air to avoid risks of diseases

4 AERECO Sensor range S-C02 AN INNOVATIVE TECHNOLOGY FOR A TOP QUALITY MEASUREMENT Adapdable to various applications, it can be easily integrated to your system to drive ventilation, air conditioning and be part of your building management system (BMS). S-CO2 meets the needs of premises of specialized facilities such as offices, locker rooms, classrooms, etc.

AERECO Sensor range 5 Accurate device to measure CO 2 concentration reliably Long-term stability and dependability Dual detection measurement Non-dispersive infrared (NDIR) 2 outputs for easy connection: analog (0-10V) and digital (PWM) Can be adapted to different markets and applications Compact design, simple to install, ready to use No maintenance The Indoor air quality can generally be accessed through the measurement of carbon dioxide concentration, known as a representative index. The S-CO2 is a performing CO 2 sensor which has been specially designed to accurately assess the indoor CO 2 concentration. Adaptable for different applications, it can be used to drive ventilation, air conditioning, and other HVAC systems.the compact and small design of the sensor allows a discreet installation. S-CO2, a reliable and accurate device that enables systems to optimize indoor air quality. Its technologies allow long term stability and performance. Indeed, the S-CO2 is pre-calibrated to measure at a real-time the indoor CO 2 concentration levels from 0 to 2000 ppm and outputs both 0-10 V analog and digital (PWM) signals. Thanks to its dual detection measurement technology, the S-CO2 can be placed in any room at any time. This smart device allows continuous dependability whatever the use of the room. The S-CO2 is tested, validated, documented and flexible according to the life cycle of the installation. Moreover, the Aereco CO 2 sensor integrates the NDIR technology, a selective auto-calibred technology that allows a good assessment of the indoor air quality. Diffusion Membrane Infrared Filters Reference C0 2 - Gas Dual Detection Infrared Detector CO 2 Microprocessor Infrared Source Waveguide Scheme of the NDIR technology working in the S-CO2 sensor

6 AERECO Sensor range S-VOC A SMART SENSOR FOR HOLISTIC ASSESSMENT OF INDOOR AIR QUALITY Adapdable to various applications, it can be easily integrated to your system to drive ventilation, air conditioning and be part of your building management system. S-VOC meets the needs of premises of specialized facilities such as restaurants, fitness rooms, locker rooms, classrooms, etc.

AERECO Sensor range 7 Accurate measurement of VOC concentration and odours Long-term stability and performance MOS* technology Equivalence of CO 2 concentration 2 outputs for easy connection: analog (0-10V) and digital (PWM) Can be adapted to different markets and applications Compact design, simple to install, ready to use No maintenance Indoor environments contain various gases and microscopic particles that can impact human health. The S-VOC is designed to accurately and reliably assess the level of volatile organic compounds (VOCs) typically associated with cigarette smoke, cooking smells and other pollutants. The S-VOC also evaluates the concentration of carbon dioxide, an essential criterion in indoor air quality measurement (see graph below). In any environment requiring demand-controlled ventilation, such as commercial facilities, offices, classrooms, the S-VOC now makes it possible to assess more than just the CO 2 criterion of IAQ, and to come closer to the perceived air quality. Thanks to its compact design, the S-VOC is simple to fit into your installation and your room. A pertinent and extended measurement of indoor air quality Using the MOS technology, the S-VOC measures the concentration of VOC and odours at a real time and evaluates the CO 2 level of the room. Its output signal reports values from 0 to 2000 on a ppm CO 2 equivalent** IAQ scale. This output signal is available simultaneously in two forms: analog (0-10V) and digital (PWM). ** The correlation between human CO 2 and VOC production provides a standardized output signal in CO 2 equivalents units [ppm] * MOS (Metal Oxide Semiconductor) technology: change of the electrical characteristics of the sensing layer depending on the nature and the concentration of the VOCs which are detected. VOC rate CO 2 rate VOCs CO 2 H 2 O odours window open / closed Electrodes Metale oxide Heated membrane 0 1 2 3 4 Time in hours signal from a basic CO 2 sensor signal from the S-VOC, reflecting the detection of both CO 2 and VOC components Correlation between CO 2 level and VOC level MEMS substrate Scheme of the MOS technology working in the S-VOC sensor

8 AERECO Sensor range S-RH/T A VERSATILE UNIT THAT MEASURES HUMIDITY AND TEMPERATURE Adapdable to various applications, it can be easily integrated to your system to drive ventilation, air conditioning and be part of your building management system. S-RH/T meets the needs of premises of specialized facilities such as school lavatories, fitness center showers, locker rooms, hotels bathrooms, etc.

AERECO Sensor range 9 Digital humidity and temperature sensor Fully calibrated High accuracy The S-RH/T is designed for applications such as demand-controlled ventilation and air conditioning where accurate measurements, excellent long-term stability, and maintenance free-operation are absolute musts. Wherever the unit is installed (schools, cloakrooms, etc.), the temperature and humidity measurements are available simultaneously to optimize their contribution to comfort and health. Excellent long-term performance Capacitive technology for humidity measurement Band gap technology for temperature measurement No maintenance A smart and effective device Using the dependable capacitive technology to measure humidity and the band gap technology for temperatures, each sensor is fully calibrated for best accuracy: +/-2% RH* and +/-0.3 C**. The user can choose between two signals: analog (0-10V) and digital (PWM) (both available simultaneously for both humidity and temperature). *typical accuracy for RH from 20 % to 80 % **typical accuracy for T from 5 C to 60 C Front part Rear part Humidity capacitive sensor (with dust protection polish) Temperature sensor Welding Scheme of the S-RH/T sensor

10 AERECO Sensor range S-SERIE, SIMPLY MODULAR ACCORDING TO YOUR NEEDS INSTALLATION OF ONE SENSOR According to your HVAC system compatibility, you can connect the sensor directly or install an additionnal device (a voltage inverter or variable frequency drive). If the HVAC system includes a variable frequency drive, then you can directly connect the sensor to it. If it isn t included, then you need to install an additionnal variable frequency drive. Examples of installations Direct connection to the air conditionner system Signal 0-10V or PWM One Sensor Air conditionner system 1 2 In this case, the HVAC system is already equiped with a voltage inverter. 1 Sensor 2 Air conditionner system Installation of an additionnal device If your HVAC system isn t compatible with the Aereco Sensors signals, you must install an additionnal voltage inverter that will convert the Aereco sensors signals into a signal or a frequency that the HVAC system is able to use. Signal 0-10V or PWM Signal One Sensor Voltage Inverter Exhaust Fan 1 3 Note: all the devices have to respect the total impedance of maximum 1mΩ to limit the losses when using 0-10V output. 2 1 Sensor 2 Voltage inverter 3 Exhaust Fan

AERECO Sensor range 11 INSTALLATION OF SEVERAL SENSORS According to the volume or the use of the room, you can also install several sensors. Then you must add a microcontroller which has been previously computerized. Microcontroller The microcontroller will take all the sensor s data, and make an average to send a single signal to drive the HVAC system. Signal from Sensor 1 Signal from Sensor 2 Conversion Analog - Digital Average Signal from Sensor 3 Microcontroller Note: all the devices have to respect the total impedance of maximum 1mΩ to limit the losses when using 0-10V output. Exhaust Fan Single one signal to the exhaust fan 1 2 3 1 2 3 Sensors Microcontroller Exhaust fan BMS TROUGHT COMPUTER Computer Sensors Fan You can also use a computer to collect all the sensors data via a software

12 AERECO Sensor range Recommended uses of S-Serie sensors Type of room / building Location S-CO2 S-VOC S-RH/T School Classrooms ++++ ++++ Lavatories ++ +++ +++ Companies administration Offices ++++ ++++ Meeting rooms ++++ ++++ Fitness center Locker rooms ++++ ++++ +++ Showers ++++ Hotel Bedrooms ++++ ++ Bathrooms ++ ++++

AERECO Sensor range 13 DID YOU KNOW? PWM SIGNAL A Pulse-Width Modulation is a technique used into a pulsing signal. It is a type of modulation. Pulse-width modulation uses a rectangular pulse wave whose pulse width is modulated resulting in the variation of the average value of the waveform. 0-10V A 0-10V output is a voltage output with limit values : 0 and 10V. It is a variation of voltage proportional to a measured parameter at a real time. The main advantage of PWM is that power loss in the switching devices is very low. In the example below the information sent is a 40% duty cycle (t / T). 10 V Signal Parameter 2000 5 V 0 V 0 Level of the indoor parameter (ex : CO Time 2, VOCs) Intensity of the 0-10V signal

14 AERECO Sensor range

AERECO Sensor range 15 S-CO2 CO 2 sensor with digital and analogic outputs Standard code Measurement principle S-CO2 CAP1159 Non-Dispersive Infrared Technology (NDIR), Dual-Source Infrared System Working range ppm CO 2 0... 2 000 ppm CO 2 Accuracy at 25 C and 1 013 mbar ppm ± (60 ppm +2 % of measured value in a [0 ppm; 2000 ppm] range) Response time s < 195 s Temperature dependence CO 2 / C typ. 2 ppm CO 2 / C (0...50 C) Long-term stability ppm / year typ. 20 ppm / year Measurement reporting interval s 60 s Supply voltage VDC 12 VDC +/- 10 %. Average power consumption A 120 ma (reading), 10 ma (base). Max. peak current A 1 A (use for fuse sizing) Enclosure protection IP 20 Working and storage conditions -40...60 C 5...95 % RH (without condensating) 85...110 kpa PWM digital output Output data ppm 0 % = 0 ppm ; 100 % = 2 000 ppm Voltage VDC 12 VDC +/- 10 %. Frequency KHz 1 KHz 0-10 V analog output Output data 0 to 10 V. 0 V = 0 ppm ; 10 V = 2 000 ppm Voltage V 0 to 10 V Required impedence Ω >1MΩ Characteristics Weight g 80.5 g Colour white Material ABS Dimensions in mm 95 32 95 82

16 AERECO Sensor range S-VOC VOC sensor with digital and analog outputs S-VOC Standard code CAP1160 Measurement principle Micro-machined metal oxide semiconductor (MOS) technology Working range CO 2 eq 0...2 000 ppm CO 2 eq Measurement reporting interval s 60 s Supply voltage VDC 12 VDC +/- 10 % Average power consumption A 40 ma Max. peak current A 1 A (use for fuse sizing) Enclosure protection IP 20 Storage conditions -25 50 C 5...95 % RH (without condensation) 85...110 kpa Working conditions 0 50 C 5...95 % RH (without condensation) 85...110 kpa PWM digital output Output data 0 to 100 % 0 % = 0 ppm CO 2 eq ; 100 % = 2 000 ppm CO 2 eq Voltage VDC 12 VDC +/- 10 %. Frequency KHz 1 KHz Output 0-10 V (analog) Output data 0 to 10 V 0 V = 0 ppm CO 2 eq ; 10 V = 2 000 ppm CO 2 eq Voltage V 0 to 10 V Required impedence Ω >1MΩ Characteristics Weight g 80.5 g Colour white Material ABS 95 32 Dimensions in mm 95 82

AERECO Sensor range 17 S-RH/T Relative humidity and temperature sensor with digital and analog outputs S-RH/T Standard code CAP1161 Measurement principle Capacitive humidity sensor Band gap temperature sensor Working range C / RH% 0 C +50 C 0 % - 100 % Relative Humidity Precision RH typical +/-2,5 %, max +/-3,5 % RH at 25 C in 20 % -80 % range Accuracy of temperature max +/-0,6 C in [5 C ; 50 C] range, typical 0,5 C Measurement reporting interval s 60 s Supply voltage VDC 12 VDC +/- 10 % Average power consumption A 15 ma Max. peak current A 1 A (use for fuse sizing) Enclosure Protection IP 20 Storage conditions 10 50 C 0...60 % RH PWM digital output Output data 0 to 100 % 0 % = 0 % RH - 100 % = 100 % RH 0 % = 0 C - 100 % = + 50 C Voltage VDC 12 VDC +/- 10 % Frequency KHz 1 KHz 0-10 V analog output Output data 0 to 10 V 0V = 0 % RH - 10 V = 100 % RH 0V = 0 C - 10 V = + 50 C Voltage V 0 to 10 V Required impedence Ω >1MΩ Characteristics Weight g 80.5 g Colour white Material ABS Dimensions in mm 95 32 95 82

18 AERECO Sensor range +2 200 000 products made per year 5million dwellings equipped since Aereco was founded in 1984 +300 employees in the group dwellings equipped per year +30 countries where Aereco is active

AERECO Sensor range 19

Aereco S.A. 62 rue de Lamirault Collégien 77615 MARNE LA VALLEE CEDEX 3 FRANCE tel. +33 1 60 06 44 65 fax +33 1 64 80 47 26 www.aereco.fr CAT623GB_A Aereco, Fotolia, PhotoAlto. Diclaimer: The information in this document are not contractual. Content is provided for informational purposes; The information in this document may contain technical inaccuracies or typographical errors. This information can be periodically modified. Aereco can not be held responsible.