QPM Series Indoor Air Quality Duct Sensors

Similar documents
Room air quality sensors

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Outside Temperature Sensors

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Technical Instructions Document No EA GQD June 23, OpenAir

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Differential pressure sensors

User Manual. PolyGard AT-2000 V3. Infrared Refrigerant Gas Transmitter Serial No. AT March, 2009

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

DP2500 DP0100 DP0250 Differential Pressure Transmitter

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Electromotoric actuators for stroke valves

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Power supply CP-D 24/4.2 Primary switch mode power supply

User Manual. PolyGard ADTD Infrared Carbon Dioxide Transmitter Serial No. SM03_00X. October, 2011

WIRELESS BASE STATION WIRELESS CONFIGURATION TOOL WIRELESS REPEATER

B850 Boiler House Energy Monitor

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Room Temperature Controllers. for heating and cooling systems

PolyGard Digital Transmitter DGC DT-02

Power supply CP-D 24/1.3

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Room Temperature Controllers. for heating and cooling systems

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

B850 Boiler House Energy Monitor

VENTI-LIGHT VLD. Ventilatie Indicator G e b r u i k e r s h a n d l e i d i n g. Ampèrestraat NL-1446 TR PURMEREND

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

When ordering, specify quantity, product number and description.

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

Power supply CP-D 12/2.1

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Spring Return DuraDrive Proportional Actuator

Zelio Control Measurement Relays

S-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS

Electromotoric actuators for valves

Appendix A: Specifications

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Hygro-ThermoTransmitter-compact xxx

Type CP-S, CP-C & CP-A Switch mode

s Climatix extension module 26 I/Os POL985.00/XXX

Custom "Compact" range with display CD20 Custom Part number

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Room Temperature Controllers. for heating and cooling systems

Power supply CP-E 24/0.75

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

02/11/2015

Primary switch mode power supplies Product group picture

CP-E range Benefits and advantages

02/11/2015

HLC-1000 High-limit Humidity Control

Non-Spring Return DuraDrive Modulating Actuator

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

MODEL: M2DYS SEN TRONIC AG

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Power supply CP-E 24/2.5

Non-Spring Return EconoDrive Proportional Actuator

Baro Transmitter PTB x1.073

Dual Technology Wall Mount Occupancy Sensor

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Infrared Carbon Dioxide Gas Module ( single beam )

Room Temperature Sensors

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

High-precision process calibrator Model CED7000

02/11/2015

RWD68U Controller. Installation and Commissioning Guide Document No October 1, Function. Application

02/11/2015

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Power supply CP-E 24/2.5

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

CP-T range Product group picture

Installation Instructions

Universal Controller

Level Lance Model 5100

Power supply CP-E 24/20.0

QAC910. Meteo Sensor. Synco living

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

Power Supplies 3. SDN-C Compact DIN Rail Series

Power supply CP-T 24/20.0 Primary switch mode power supply

08/07/2015

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Installation Instructions Space Temperature Transmitter

Safety switches with slotted hole lever

Transcription:

Document No. CE1N1962 QPM Series Indoor Air Quality Duct Sensors Description The QPM Series Room Carbon Dioxide (CO 2 ) and Air Quality Duct Sensors are designed for applications where precise, stable carbon dioxide or air quality sensing is required. Several models are available with either CO 2 only, or with Volatile Organic Compounds (VOC) (also known as mixed gas), relative humidity and/or temperature sensing. All units deliver a 0 to 10 Vdc signal for all outputs and have a CO 2 measuring range of 0 to 2000 ppm. Features Maintenance-free, Non Dispersive Infrared (NDIR) CO 2 sensing element is ideal for use in spaces that are occupied 24/7. Application Combination units enable a single sensor to take the place of up to three individual sensors. No recalibration required. 24 Vac or 15 to 35 Vdc operating voltage Signal outputs 0 to 10 Vdc or 0 to 5 Vdc (field selectable) For use in air ducts of ventilation and air conditioning applications to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation. The sensor acquires: CO 2 concentrations as an indication of occupancy in rooms where smoking is prohibited. VOC concentrations as an indication of odors in the duct air, such as tobacco smoke, body odor, or material fumes. The relative humidity of the duct air. The duct air temperature. QPM2102 models measure both CO2 and volatile organic compounds (VOC) for optimized indoor air quality. A single 0-10V or 0-5V (selectable) output signal is automatically adjusted to reflect the higher of the two values. This enables the combination CO2 + VOC sensor to be easily substituted for a CO2 sensor in any demand control ventilation control system. The QPM21 Series Sensors can be used as: Control sensors in the supply or exhaust air duct. Transmitters for building automation and control systems and/ or display units.

QPM Series Indoor Air Quality Duct Sensors Application, Continued Typical use: Acquisition of CO 2 and VOC concentrations: In party rooms, lounges, fair pavilions and exhibition halls, restaurants, canteens, shopping malls, sports gymnasiums, sales rooms, and conference rooms. Acquisition of CO 2 concentrations: In ventilation applications of rooms with varying occupancy levels where smoking is prohibited, such as museums, theaters, movie theaters, auditoriums, office spaces and school rooms. NOTES: The QPM Series Sensors are not designed for use as safety devices, such as gas or smoke warning devices. Do not install outdoors. Product Numbers Table 1. Product Number QPM2100 QPM2102 QPM2102D CO 2 Measuring Range VOC Sensitivity Temperature Measuring Range QPM2160 0 to 2000 ppm 32 F to 122 F/-31 F to 95 F QPM2160D (0 to 50 C/-35 to 35 C) Humidity Measuring Range Measured Value Display No Low (R1) Normal (R2) High (R3) No Yes No QPM2162 0 to 100% No QPM2162D Yes Yes Ordering The sensor is supplied complete with mounting flange and cable entry gland M16. Equipment Combinations Mode of Operation CO 2 Concentrations The QPM Series Air Quality Sensors are suited for use with all types of systems and devices capable of acquiring and handling the 0 to 10 Vdc output signal delivered by the sensor. The QPM Series Air Quality Sensors acquire the CO 2 concentration by infrared absorption measurement (NDIR). Due to an additional integrated reference light source, the measurement is always accurate. This reduces service costs as no service or recalibration is needed. The resulting output signal of 0 to 10 Vdc or 0 to 5 Vdc is proportional to the CO 2 content of the ambient air. Figure 1. Function Diagram CO 2 (Output U1). Page 2

QPM Series Indoor Air Quality Duct Sensors Technical Instructions CO 2 /VOC Concentration (QPM2102 and QPM2102D Only) The sensor acquires and evaluates the CO 2 /VOC concentration and converts it to a ventilation demand signal. It represents the result of maximum selection of the CO 2 measuring signal and the filtered VOC measuring signal. With maximum selection, the two demand signals are compared and depending on the result and the selected VOC sensitivity delivered as the common air quality demand. The ventilation demand signal is delivered via output U2 as a 0 to 10 Vdc or 0 to 5 Vdc signal to be fed to the ventilation controller. Figure 2. Ventilation Demand Diagram (Output U2). VOC Sensitivity Response Time VOC Signal Relative Humidity (QPM2162 and QPM2162D Only) Temperature (QPM2160, QPM2160D, QPM2162 and QPM2162D Only) Using the jumper on the setting element for the measuring range, the impact of VOC ventilation demand on maximum selection against CO 2 ventilation demand can be changed. The position in the middle (R2) produces normal sensitivity of the VOC signal (factory setting). The other two positions are used for increasing (R3) or decreasing (R1) VOC sensitivity See Figure 3. Before the processor handles a change of the measured VOC value for maximum selection, there is a delay in response time of three minutes for every Volt the signal value changes. The sensor acquires the relative humidity in the room with a capacitive humidity sensing element whose capacitance changes as a function of the relative humidity. An electronic measuring circuit converts the signal from the sensing element to a continuous 0 to 10 Vdc signal, corresponding to a relative humidity range of 0 to 100%. The sensor acquires the air duct temperature with a sensing element whose electrical resistance changes as a function of the temperature. The change is converted to an active 0 to 10 Vdc output signal ( 32 F to 122 F [0 C to 50 C] or -31 F to 95 F [-35 C to 35 C]). Page 3

QPM Series Indoor Air Quality Duct Sensors Mechanical Design The duct air quality sensor consists of housing, printed circuit board, connection terminals, mounting flange and immersion rod with measuring probe. The two-sectional housing is comprised of base and removable cover (without display: snap-on design, with display: screwed fastening). The measuring circuit and the setting elements are located on the printed circuit board inside the cover, the connection terminals on the base. The humidity and temperature sensing elements are located at the end of the measuring probe and are protected by a filter cap. Immersion rod and housing are made of plastic and are rigidly connected. The sensor is fitted with the mounting flange supplied with the sensor. The flange is placed over the immersion rod and then secured at the required immersion length. Setting Elements NOTE: The setting elements are located inside the cover. Measuring Range QPM2100 QPM2102/QPM2102D Figure 3. Setting Elements. Meaning of the different jumper positions: For CO 2 Only: Jumper in the middle position (R2) = 0 to 2000 ppm (factory setting). R1 and R3 are not used. For CO 2 /VOC, jumpers determine VOC Sensitivity: - Jumper in the left vertical position (R1) = VOC sensitivity "low". - Jumper in the middle position (R2) = VOC sensitivity "normal" (factory setting). - Jumper in the right vertical position (R3) = VOC sensitivity "high". Page 4

QPM Series Indoor Air Quality Duct Sensors Technical Instructions QPM2160/QPM2160D, QPM2162/QPM2162D Active Test Function Temperature Display Changeover Troubleshooting QPM2100/QPM2100D QPM2102/QPM2102D QPM2160/QPM2160D QPM2162/QPM2162D Display of Measured Values Disposal For the CO 2 and temperature, jumpers determine temperature range: - Jumper in the upper position (R1) = -31 F to 95 F (-35 to 35 C). - Jumper in the positions (R2 or R3) = 32 F to 122 F (0 to 50 C) (R2, factory setting). Jumper for the measuring range in the horizontal position: The signal output delivers the values according to table "Test function active". Meaning of the different jumper positions: - Jumper in the right vertical position = C (factory setting). - Jumper plug in the left vertical position = F. In the event of CO 2 failure, 10 Vdc or 5 Vdc will be present at signal output U1 (after 60 seconds). In the event of CO 2 or VOC failure, 10 Vdc or 5 Vdc will be present at signal output U2 (after 60 seconds). If the temperature sensor becomes faulty, 0V will be present at signal output U2. If the temperature sensor becomes faulty, 0V will be present at signal output U3, and the humidity signal at signal output U2 will increase to 10 Vdc or 5 Vdc (after 60 seconds). If the humidity sensor becomes faulty, 10 Vdc or 5 Vdc will be present at signal output U2 (after 60 seconds), and the temperature signal will remain active. With sensors QPM2102D, QPM2160D and QPM2162D, the measured values can be read on an LCD. The following measured values are displayed: CO 2 : In ppm CO2 + VOC: As a bar chart (4 bars U2 = 2V, 20 bars U2 = 10V) More bars = higher VOC Temperature: In degrees C or F Humidity: In % rh The major plastic components bear the material references in compliance with ISO/DIS 11 469 for environment-friendly disposal. Accessories AQF3101 Filter cap (for replacement) Engineering Notes Cable Routing and Selection The sensor must be powered by a transformer for Safety Extra Low-Voltage (SELV) with separate windings, suited for 100% duty. It must be sized and fused in compliance with local safety regulations. When sizing the transformer, the power consumption of the sensor must be taken into consideration. For information about wiring, see the Technical Instructions of the devices with which the sensor is used. Observe maximum permissible cable lengths. When laying the cables, it should be considered that electrical interference increases the longer the cables run parallel and the smaller the distance between them. Use shielded cables on applications with EMC problems. For the secondary power lines and signal lines, use cables with twisted pairs. Page 5

QPM Series Indoor Air Quality Duct Sensors Mounting Notes Mounting Location and Orientation Commissioning Notes To ensure degree of protection, mount the sensor with the cable entry pointing downward. Mount the sensor in a location where it can be easily accessed for service. If used in connection with steam humidifiers, the distance to the humidifier must be a minimum of 9.8 feet (3 m). If permitted by the installation, the distance should be as great as possible, but no more than 32.8 feet (10 m). Handle carefully; the sensing elements in the immersion rod are susceptible to impact and shock. The sensor must not be mounted in a ventilation application on top of a building (impact of solar radiation). To ensure correct operation, the sensor s ambient temperature must be between 23 F to 113 F ( 5 C to 45 C). Check the sensor s functions 30 minutes after applying power. Checking the CO 2 function: In well-ventilated spaces, the sensor shows the CO 2 concentration of the outside air. Typically, this is 360 ppm (depending on the sensor s measuring accuracy). Also, a basic functional check can be made by exhaling on the sensor. Note that the sensor s rate of response has been purposely delayed (time constant t 90 = 5 minutes). Checking the VOC function: Touch the sensor with a cotton ball dowsed in alcohol. Specifications Power supply Ventilation should start when the preset switching level of the connected controller is reached. After applying power to sensors with display, Init will appear for approximately six seconds. Operating voltage (SELV) 24 Vac ±20% Frequency 50/60 Hz at 24 Vac Power consumption 2 VA Functional data, CO 2 Measuring range (MV = measured value) 0 to 2000 parts per million (ppm) * Measuring accuracy @ 73 F (23 C) < + (50 ppm + 2% MV) and 1013 hpa Temperature dependency in 23 F to 113 F + 2 ppm/ C typically (-5 C to 45 C) range Functional data, maximum selection of CO 2 and VOC with QPM2102/QPM2102D Long-time drift < + 5% measuring range/5 years Time constant t 90 <5 minutes Output signal, linear (terminal U1) 0 to 10 or 0 to 5 Vdc 0 to 2000 ppm Recalibration Not required for 8 years * Allow up to 96 hours for unit to reach published accuracy. Measuring range VOC 0 to 2000 ppm VOC sensitivity See Table 1 Output signal, linear (terminal U2) 0 to 10 or 0 to 5 Vdc 0 to 2000 ppm Response time, VOC signal t voc 3 minutes/v Page 6

QPM Series Indoor Air Quality Duct Sensors Technical Instructions Functional data, rh with QPM2162/QPM2162D Functional data, temperature with QPM2160/QPM2160D, QPM2162/QPM2162D Range of use 0 to 95% rh (non-condensing) Measuring range 0 to 100% rh Measuring accuracy @ 73 F (23 C) and 24 Vac 0 to 30/70 to 95% rh + 5% rh 30 to 70% rh + 3 rh (typically) Temperature dependency < 0.1% rh/ C Time constant Approximately 20 seconds Output signal, linear (terminal U2) 0 to 10 or 0 to 5 Vdc 0 to 100% rh Environmental temperature range for 23 F to 113 F (-5 C to 45 C) electronics Measuring range 32 F to 122 F (0 C to 50 C) (R2, R3) -31 F to 95 F (-35 C to 35 C) (R1) Measuring element NTC 10K Ω Measuring accuracy at 24 Vac 59 F to 95 F (15 C to 35 C) + 1.4 F (+ 0.8 C) outside the above range, between: -31 F to 59 F/95 F 122 F + 1.8 F (+1 C) (-35 C to 15 C/35 C to 50 C) Time constant <3.5 min in 2 m/s moving air Output signal, linear (terminal U2 or U3) 0 to 10 or 0 to 5 Vdc 32 F to 122 F (0 C to 50 C)/-31 F to 95 F (-35 C to 35 C) Air velocity Maximum air velocity V max 10 m/second Electrical connections Screw terminals for 1 12 AWG or 2 16 AWG Environmental conditions Transport: Temperature: Humidity: -13 F to 158 F (-25 C to 70 C) < 95% rh Materials and colors Base Polycarbonate, RAL 7001 (silver-gray) Cover Polycarbonate, RAL 7001 (light-gray) Immersion rod Polycarbonate, RAL 7001 (silver-gray) Filter cap Polycarbonate, RAL 7001 (silver-gray) Mounting flange PA66 GF35 (black) Cable entry gland PA, RAL 7035 (light-gray) Sensor (complete assembly) Silicone-free Packaging Corrugated cardboard Standards Electromagnetic compatibility Immunity (QPM2162) EN 61 000-6-1 Immunity (QPM2100, QPM2102, EN 61 000-6-2 QPM2160) Emissions EN 61 000-6-3 conformity EMC directive 89/336/EEC conformity to Australian EM framework Radio Communication Act 1992 Radio Interference Emission Standard AS/NZS 3548 UL Listed UL 873 cul Listed Canadian Standard C22.2 No. 24-93 Weight (including packaging) Approximately 0.6 lb (0.247 kg) Page 7

QPM Series Indoor Air Quality Duct Sensors Wiring Connections Figure 4. QPM2100, QPM2100D. Figure 5. QPM2102, QPM2102D. Figure 6. QPM2160, QPM2160D. Figure 7. QPM2162, QPM2162D. G, G0 System potential 24 Vac (SELV) G0 System neutral and measuring neutral U1 Signal output 0 to 10 Vdc or 0 to 5 Vdc U2 Signal output 0 to 10 Vdc or 0 to 5 Vdc U3 Signal output 0 to 10 Vdc or 0 to 5 Vdc R..(*) Signal output with R...= 0 to 10 Vdc; without R... = 0 to 5 Vdc B, M Passive temperature output (interchangeable) Page 8

QPM Series Indoor Air Quality Duct Sensors Technical Instructions Dimensions In Inches (Millimeters) Figure 8. QPM Series Duct Air Quality Sensors Dimensions in Inches (Millimeters) Page 9

QPM Series Indoor Air Quality Duct Sensors Dimensions, Continued In Inches (Millimeters) Figure 9. QPM Series Duct Air Quality Sensors with Display. Figure 10. Drilling Pattern. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Products or company names mentioned herein may be the trademarks of their respective owners 2016 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA +1-847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com Document No. CE1N1962 Printed in the USA Page 10