Cisco Prisma Optical Passive Components

Similar documents
Prisma DWDM Passives. Features. Optical Passive Components

WaveSmart Wave Division Multiplexing (WDM)

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Cisco Prisma II 1.2 GHz High Density Long Reach Multiwave Transmitter

Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Prisma and Laser Link DWDM Passives for LGX-Compatible Systems

Prisma II Multi-Wavelength High Density Transmitter

Cisco EDR 85 System: Modules for Cisco GainMaker and GS7000

XSD Single Fiber series DWDM passive optical components

Prisma II 1310 nm High Density Transmitter and Host Module

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

WaveReady CWDM Add/Drop for OSP Splice Enclosure

Optical Passives (ISP)

CWDM. DATA SHEET DB4133-E Issue L Page 1 of 8

Headend Optics Platform (CH3000)

Prisma II 1310 nm High Density Transmitter and Host Module

Further more all functions as well available in splice trays or splice enclosures (-40 to 85 C)

Compact Reverse Transmitters with DFB or CWDM Lasers

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes

DWDM Dual Fiber series

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Overview. Highlights. General Specification. Datasheet

Optical Passives and Accessories

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

OPC1600 MUX WDM OADM SPLITTER

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

WaveReady Single-Channel DWDM Add/Drop for OSP Splice Enclosure. MDF-01AD10xx0

Digital Return System

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

WaveReady 8-Channel DWDM OSP Optical Add/Drop Multiplexer for Splice Enclosures. MDF-08MD1N0xB and MDF-08MD1Z0xB

CWDM Cisco CWDM wavelengths (nm)

Prisma II 1 GHz SuperQAM Transmitter

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

End of Life. Headend Optics Platform (HLP) SPL7210S/A. HL2 Series SUPRALink High Density DWDM Transmitter FEATURES PRODUCT OVERVIEW. arris.

On the subsequent pages, you will find the full, parameter-for-parameter comparison. If you have any questions, please contact Fiberdyne Labs.

Prisma II 1 GHz SuperQAM Full Spectrum Transmitter

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

Dense Wavelength Division Multiplexer (DWDM) 200 GHz Spacing, Multi-Channel, 2ch, 4ch, 8ch, 16ch, 20ch in PEACOC Flexible Tray

Cisco 1218 MHz GainMaker High Gain Dual (HGD) System Amplifier

Digital Return System

Cisco 1.2GHz GainMaker Line Extender (GMLE)

CWDM Single Fiber series

Cisco 1218 MHz GainMaker High-Gain Balanced Triple System Amplifier

Passive WDM Networking

Prisma II 1 GHz 1550 nm Transmitters

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

OPCOM100-DMU40 40-Channel DWDM. Mux/Demux. Typical Application. Figure.1 Point to Point Topology. Datasheet. Raisecom Technology Co., Ltd.

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

1752A 1550 nm DOCSIS 3.1 DWDM DFB Laser Module

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

16 Channels C21-C36 Dual Fiber DWDM Mux Demux, w/expansion Port 1U Rack Mount, LC/UPC

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

LEAD Fiber Optics PRODUCT CATALOGUE

MODEL BLN GHz FIBER DEEP NODE STARLINE SERIES

HDO772 C-BAND DWDM FIBRE TRANSMITTER

CHP Max CORWave Full Spectrum Multi-Wavelength Forward Transmitters

LEAD Fiber Optics PRODUCT CATALOGUE

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Opti Max Optical Node Series

Model 6942 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

OMxxDyy-100zz-ab:cd-(M5)-XXYY

GT Channel Ultra Compact CWDM Mux & DeMux

GainMaker High Output 4-Port Node

1751A 1550 nm DWDM DFB Laser Module

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM. Typical Application. Figure.1 Chain Topology. Datasheet. Raisecom Technology Co., Ltd.

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

Datasheet. 40ch DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC. Overview. Highlights

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

WDM -Transmission V-1.

1751A 1550 nm DWDM DFB Laser Module

1751A 1550 nm DWDM DFB Laser Module

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

GainMaker High Output Reverse Segmentable Node with 40/52 MHz Split

Optical Passives (OSP)

nm C-Band DWDM DFB Laser Module

CWDM PLUS/MAX Series OVERVIEW KEY FEATURES AND BENEFITS TECHNOLOGY.

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Technical Specifications

Cisco s CLEC Networkers Power Session

Why Using Fiber for transmission

Good Things Come in Small Cubes. Cube Optics 100G Metro Evolution TREX14 01/06/14

1754C C-Band DWDM DFB Laser Module

Dual & Single Fiber Compact CWDM Mux Demux

DWDM Mux/Demux product range

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

Putting the D back into DWDM Full-band Multi-wavelength Systems Mani Ramachandran CEO / CTO InnoTrans Communications

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

OFS AllWave non-dispersion shifted single-mode optical fiber

Transcription:

Data Sheet Cisco Prisma Optical Passive Components This data sheet includes optical wavelength filters, multiplexers, and demultiplexers that operate in the C-band from 1525 to 1565 nm as well as band filters to combine C- band transmission optics with1310-nm sources. Included here are shelf-based components (LGX style), cassette-based components for use in field fiber enclosures, and passives designed to fit in Cisco nodes. As commonly used in fiber-optic distribution systems, these passive components are used to combine or separate individual or bands of wavelengths into a single fiber to economize and improve the efficiency of optical transmission systems for voice, video, and data networks. Typical applications include overlay of narrowcast and broadcast cable TV signals and bidirectional transmission of data. The products specified here include all those for use with Cisco Prisma headend optical transmitters including the legacy1310-nm line, the SuperQAM1.2 products, and the high-performance LRMW transmitters. Also included are passives designed to work with the GS7000 and GainMaker line of nodes. The shelf-based passives are packaged in industry-standard LGX-style modules of varying widths depending on the number and type of connectors used (Figure 1). Cassette-style passives for field use may be screw-mounted in widely available splice enclosures and consist of metallic housings with connectorized, color-coded, and labeled break-out cables for ease of identification. Passives for use in the GS7000 nodes are fit into a specially designed housing that readily mounts in the lid of the node. The passives are available in a variety of configurations that reflect differing uses and channel plans. Overlay and multiwave-reverse systems use contiguous ITU channels, while iwdm channel plans maximize co -propagating wavelengths when power, modulation type, or increased linearity performance is required. The options are described in the tables that follow. The iwdm plan consists of 16 wavelengths in the C-band in the range of ITU 21 through ITU 62. Although there are predefined offsets for some of the 16 wavelengths, the multiplexer and demultiplexer of optical signals can continue to be supported through standard ITU optical passives because the offsets are within the guard band of the passive - typically 0.12 nm. Cisco Prisma interoperable multiwavelength optics passives multiplexer and demultiplexer components (Figure 1) are essential when iwdm is implemented to increase network efficiency by significantly reducing fiber counts. Most units are available in the industry-recognized, LGX-compatible form factor to allow easy, snap-in mounting in a variety of enclosures and cabinets. Features Channel spacing is 100 GHz, compliant with the ITU standard wavelength grid. Filters passbands are compatible with 100-GHz systems for all channel plans. Analog, QAM, and baseband digital modulation are supported for maximum flexibility in application. LGX modules easily snap into a wide variety of enclosures and cabinets. 2017 Cisco and/or its affiliates. All rights reserv ed. This document is Cisco Public Inf ormation. Page 1 of 6

Cassette modules for outside plant environments use 900-um breakout cables for easy fiber handling. Wavelength multiplexer and demultiplexer groupings include Matched pairs of LGX and cassette modules for ease of system configuration Compatibility of all wavelength combinations for flexibility in deployments Connector types include LC/APC connectors in LGX modules for improved density in headend racks SC/APC connectors on cassettes for easy handling in outside plant environments Specifications Table 1 lists the common specifications for all filters in this data sheet. Table 2 lists the physical dimensions of the various form factors available (LGX, cassette, and GS7000 optical hub). Table 3 lists the m ultiple-channel and band-pass filters available in the LGX module form factor, and Table 4 lists single-channel DWDM filters available in the LGX module. Table 5 lists cassette versions of the filters for field use, and Table 6 lists the filters available in the GS7000 Optical Hub form factor. Table 7 lists miscellaneous filters. Table 1. Common Specifications (Unless otherwise noted, these specifications may be used for all modules.) Specification Units Cisco Prisma LGX Cisco GS7000 Optical Hub Cisco Cassette Insertion loss (maximum) multiplexer and demultiplexer db 8 channel: 2.3 16 channel: 3.0 8 channel: 2.3 16 channel: 3.0 8 channel: 2.5 16 channel: 3.3 Isolation (maximum) db >28 (adjacent channels) >40 (nonadjacent channels) Channel bandwidth at 0.5 db nm λ c ± 0.12 Channel spacing GHz 100 Polarization dependent loss db 0.20 Polarization mode dispersion ps 0.15 Express Port Insertion Loss 4 channel iwdm 8 channel iwdm db 1.3 2.8 1.6 3.0 12, 16, 20, 40 channel ITU 3.0 1.0 2017 Cisco and/or its affiliates. All rights reserv ed. This document is Cisco Public Inf ormation. Page 2 of 6

Specification Units Cisco Prisma LGX Cisco GS7000 Optical Hub Cisco Cassette Express Port Passband 4 and 8 channel iwdm (excludes active channels) nm 1520 1570 1520 1570 8 to 40 ITU channel (excludes active channels) 1260 1635 1260 1635 Upgrade Port Insertion Loss 12, 16, 20, 40 channel ITU db 3.0 3.0 Upgrade Port Passband 8 to 40 ITU channel (excludes active channels) ITU 16 63 ITU 16 63 Directivity db 50 Optical return loss db 45 Optical connector type - LC/APC SC/APC SC/APC (900 um cable) Environmental Specifications Operating temperature range ºC/ºF 5 to 65/23 to 149 40 to 85/ 40 to 185 40 to 85/ 40 to 185 Storage temperature range ºC/ºF 40 to 85/ 40 to 185 Note: Upgrade port in iwdm is designated as EXP (f or Expansion) Table 2. Dimensions Specification Units Height Width Depth LGX Module Single wide in. 5.1 1.15 6.5 cm 13 2.92 16.5 Dual wide in. 5.1 2.3 6.5 cm 13 5.8 16.5 Cassette Modules 8 channel in. 0.31 1.8 2.8 mm 8 45 70 12 channel in. 0.31 3.5 4.3 mm 8 90 110 16 or 20 channel in. 0.31 3.3 4.7 mm 8 85 120 40 channel in. 0.71 3.7 5.5 mm 18 95 140 GS7000 Optical Hub Modules 2017 Cisco and/or its affiliates. All rights reserv ed. This document is Cisco Public Inf ormation. Page 3 of 6

Product-Specific Specifications Table 3. Cisco Prisma LGX Modules Multi-channel and band-pass multiplexer and demultiplexer filter description Width Cisco Part Numbers Note: iwdm channels are ITU 21, 22, 24, 26, 28, 33, 36, 39, 44, 48, 52, 54, 57, 60, 61, 62 4 CH-iWDM-21, 22, 24, 26 -EXP-DTP-LC/APC 1 OPLGX-MD04-2126-LA 4 CH-iWDM-28, 33, 36, 39 -EXP-DTP-LC/APC 1 OPLGX-MD04-2839-LA 4 CH-iWDM-44, 48, 52, 54 -EXP-DTP-LC/APC 1 OPLGX-MD04-4454-LA 4 CH-iWDM-57, 60, 61, 62 -EXP-DTP-LC/APC 1 OPLGX-MD04-5762-LA 8 CH-iWDM-21 39 -DTP-EXP-LC/APC 1 OPLGX-MD08-2139-LA 8 CH-iWDM-44 62 -DTP-EXP-LC/APC 1 OPLGX-MD08-4462-LA 8 CH-ITU 20 27 DTP-UG-EXP-LC/APC 1 1030034 8 CH-ITU 28 35 DTP-UG-EXP-LC/APC 1 1030035 8 CH-ITU 36 43 DTP-UG-EXP-LC/APC 1 1030036 8 CH-ITU 44 51 DTP-UG-EXP-LC/APC 1 1030037 8 CH-ITU 52 59 DTP-UG-EXP-LC/APC 1 1030038 12 CH-ITU 50 61 DTP-UG-EXP-LC/APC 1 1030065 16 CH-ITU 25 40 DTP-UG-EXP-LC/APC 2 1030017 16 CH-IWDM 21 62 DTP-LC/APC 2 OPLGX-MD16-2162-LA 16 CH-IWDM 21 62 DTP-LC/APC with quad bulkhead adaptors 1 OPLGX-MD16-2162-LQ 20 CH-ITU 20 39 DTP-UG-EXP-LC/APC 2 1030016 20 CH-ITU 40 59 DTP-UG-EXP-LC/APC 2 1030031 20 CH-ITU 20 39 DTP-UG-EXP-LC/APC with quad bulkhead adaptors 1 OPLGX-MD20-2039-LQ 20 CH-ITU 40 59 DTP-UG-EXP-LC/APC with quad bulkhead adaptors 1 OPLGX-MD20-4059-LQ 40 CH-ITU 20 59 DTP-UG-EXP-LC/APC with quad bulkhead adaptors 2 OPLGX-MD40-2059-LQ Miscellaneous LGX modules 2 band filter red/blue bands RED: ITU18-39 and BLUE: 44-62 SC/APC 1 OPLGX-BPF2-1862-SA Note: this filter is in a cassette that is removable from the LGX module for field use 4 band filter iwdm pass-bands 21 26, 28 39, 44 54, 57 62 -DTP-LC/APC 1 OPLGX-BPF4-2162-LA 1310/CWDM filter with SC/APC connectors 1310 port pass band 1280 1340 nm CWDM port pass band 1420 1620 nm 1310 port insertion loss 1.2 db CWDM port insertion loss 0.8 db 1310 port isolation 20 db CWDM port isolation 12 db (see also Cisco PID 4004875 below f or unpackaged f ilter v ersion of this part) 1310/1550 Quad-filters with LC/UPC connectors 1310 port pass band 1260 1360 nm 1550 port pass band 1460 1620 nm Quad f our f ilters are mounted into a single LGX sty le module 1310 port insertion loss 1.0 db 1550 port insertion loss 1.0 db 1310 port isolation 40 db 1550 port isolation 30 db 1 4004874 1 4034491 Table 4. OADM (Single-Channel DWDM Filter in LGX Module) on ITU Grid Description (100 GHz) Part Number Description Part Number OADM,LGX-DWDM-ITU-16-SA 4003543 OADM,LGX-DWDM-ITU-38-SA 4003565 OADM,LGX-DWDM-ITU-17-SA 4003544 OADM,LGX-DWDM-ITU-39-SA 4003566 OADM,LGX-DWDM-ITU-18-SA 4003545 OADM,LGX-DWDM-ITU-40-SA 4003567 OADM,LGX-DWDM-ITU-19-SA 4003546 OADM,LGX-DWDM-ITU-41-SA 4003568 OADM,LGX-DWDM-ITU-20-SA 4003547 OADM,LGX-DWDM-ITU-42-SA 4003569 2017 Cisco and/or its affiliates. All rights reserv ed. This document is Cisco Public Inf ormation. Page 4 of 6

Description (100 GHz) Part Number Description Part Number OADM,LGX-DWDM-ITU-21-SA 4003548 OADM,LGX-DWDM-ITU-43-SA 4003570 OADM,LGX-DWDM-ITU-22-SA 4003549 OADM,LGX-DWDM-ITU-44-SA 4003571 OADM,LGX-DWDM-ITU-23-SA 4003550 OADM,LGX-DWDM-ITU-45-SA 4003572 OADM,LGX-DWDM-ITU-24-SA 4003551 OADM,LGX-DWDM-ITU-46-SA 4003573 OADM,LGX-DWDM-ITU-25-SA 4003552 OADM,LGX-DWDM-ITU-47-SA 4003574 OADM,LGX-DWDM-ITU-26-SA 4003553 OADM,LGX-DWDM-ITU-48-SA 4003575 OADM,LGX-DWDM-ITU-27-SA 4003554 OADM,LGX-DWDM-ITU-49-SA 4003576 OADM,LGX-DWDM-ITU-28-SA 4003555 OADM,LGX-DWDM-ITU-50-SA 4003577 OADM,LGX-DWDM-ITU-29-SA 4003556 OADM,LGX-DWDM-ITU-51-SA 4003578 OADM,LGX-DWDM-ITU-30-SA 4003557 OADM,LGX-DWDM-ITU-52-SA 4003579 OADM,LGX-DWDM-ITU-31-SA 4003558 OADM,LGX-DWDM-ITU-53-SA 4003580 OADM,LGX-DWDM-ITU-32-SA 4003559 OADM,LGX-DWDM-ITU-54-SA 4003581 OADM,LGX-DWDM-ITU-33-SA 4003560 OADM,LGX-DWDM-ITU-55-SA 4003582 OADM,LGX-DWDM-ITU-34-SA 4003561 OADM,LGX-DWDM-ITU-56-SA 4003583 OADM,LGX-DWDM-ITU-35-SA 4003562 OADM,LGX-DWDM-ITU-57-SA 4003584 OADM,LGX-DWDM-ITU-36-SA 4003563 OADM,LGX-DWDM-ITU-58-SA 4003585 OADM,LGX-DWDM-ITU-37-SA 4003564 OADM,LGX-DWDM-ITU-59-SA 4003586 Table 5. Cisco Cassette Modules Multi-channel and band-pass cassette filter description Cassette Cisco Part Numbers Note: iwdm channels are ITU 21, 22, 24, 26, 28, 33, 36, 39, 44, 48, 52, 54, 57, 60, 61, 62 4 CH-iWDM 21, 22, 24, 26 EXP-DTP-SC/APC 1030011 4 CH-iWDM 28, 33, 36, 39 EXP-DTP-SC/APC 1030012 4 CH-iWDM 44, 48, 52, 54 EXP-DTP-SC/APC 1030013 4 CH-iWDM 57, 60, 61, 62 EXP-DTP-SC/APC 1030014 8 CH-iWDM 21, 22, 24, 26, 28, 33, 36, 39 EXP-DTP-SC/APC 4043602 8 CH-iWDM 44, 48, 52, 54, 57, 60, 61 62 EXP-DTP-SC/APC 4043603 8 CH-ITU 20 27 DTP-UG-EXP- SC/APC OPCAS-MD08-2027-SA 8 CH-ITU 28 35 DTP-UG-EXP- SC/APC OPCAS-MD08-2835-SA 8 CH-ITU 36 43 DTP-UG-EXP- SC/APC OPCAS-MD08-3643-SA 8 CH-ITU 44 51 DTP-UG-EXP- SC/APC OPCAS-MD08-4451-SA 8 CH-ITU 52 59 DTP-UG-EXP- SC/APC OPCAS-MD08-5259-SA 12 CH-ITU 50 61-DTP-UG-EXP- SC/APC OPCAS-MD12-5061-SA 16 CH-iWDM 21, 22, 24, 26, 28, 33, 36, 39, 44, 48, 52, 54, 57, 60, 61, 62 DTP-SC/APC 4043601 16 CH-ITU 25 40-DTP-UG-EXP- SC/APC OPCAS-MD16-2540-SA 20 CH-ITU 20 39-DTP-UG-EXP- SC/APC OPCAS-MD20-2039-SA 20 CH-ITU 40 59-DTP-UG-EXP- SC/APC OPCAS-MD20-4059-SA 40 CH-ITU 20 59-DTP-UG-EXP- SC/APC OPCAS-MD40-2059-SC Miscellaneous cassette modules 1310/CWDM filter with SC/APC connectors 1310 port pass band 1280 1340 nm CWDM port pass band 1420 1620 nm 1310 port insertion loss 1.2 db CWDM port insertion loss 0.8 db 1310 port isolation 20 db CWDM port isolation 12 db (see also Cisco PID 4004874 abov e f or LGX v ersion of this part) 4004875 2017 Cisco and/or its affiliates. All rights reserv ed. This document is Cisco Public Inf ormation. Page 5 of 6

Table 6. Cisco GS7000 Optical Hub Filters Description GS 7000 Part Numbers Multiplexer and Demultiplexer GS7000-OP-iWDM ITU 21, 22, 24, 26, 28, 33, 36, 39 EXP-DTP-MPO-SC/APC 2 wide 4043955 GS7000-OP-iWDM ITU 44, 48, 52, 54, 57, 60, 61, 62 EXP-DTP-MPO-SC/APC 2 wide 4043956 GS7000-OP-iWDM ITU 21, 22, 24, 26, 28, 33, 36, 39, 44, 48, 52, 54, 57, 60, 61, 62 DTP-MPO- SC/APC 3 wide 4043953 Table 7. Cisco Miscellaneous Filter Modules Multi-channel filter description Form Factor Cisco Part Numbers 40 channel filter ITU 20 59 inclusive - DTP-UG-EXP-LC/APC 1 RU 1030030 Cisco Capital Financing to Help You Achieve Your Objectives Cisco Capital can help you acquire the technology you need to achieve your objectives and stay competitive. We can help you reduce CapEx. Accelerate your growth. Optimize your investment dollars and ROI. Cisco Capital financing gives you flexibility in acquiring hardware, software, services, and complementary third -party equipment. And there s just one predictable payment. Cisco Capital is available in more than 100 countries. Learn more. For More Information Cisco Prisma iwdm Passives products offer one of the most complete ranges of high -performance components in the industry. For additional information, please visit: http://www.cisco.com/en/us/products/ps8981/index.html. Printed in USA C78-737622-00 01/17 2017 Cisco and/or its affiliates. All rights reserv ed. This document is Cisco Public Inf ormation. Page 6 of 6