TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

MB120S 120W Single Output Medical Series

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

C B. Models. Models 2MOPP

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

TE40 40W Single Output External Power Test & Measurement/Industrial Series

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE90 90W Single Output External Power Test & Measurement/Industrial Series

TB65 65W Single Output Test and Measurement/Industrial Series

DA45C USB-PD. Product Descriptions. 45 Watts

TE60 60W Single Output External Power Test & Measurement/Industrial Series

LB115S 115W Single Output

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

LFWLP W 12V 15.00A 25.00A 92%

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

TE W Single Output External Power Test & Measurement/Industrial Series

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

50W Constant Current (700mA) Dimming LED Driver

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Typical Efficiency (2) Max. Output Power. 24 Vdc 90 ~ 305 Vac 0~1080mA 26 W 84% EUV-026S024PS(3)

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

IEC/EN/UL60950 & CE certified, EN55032 Class B

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

HEC-100RTA-48QSCA Rev A1.0

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

HEC-45LTN-45PFAS Rev A

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Max. Output Power. Typical Efficiency (1) 12 Vdc 90 ~ 305 Vac 0~8.33 A 100 W 91% EUV-100S012ST

VOF XX - XXX - X

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

Max. Output Power. Typical Efficiency (2) 12 Vdc 90 ~ 305 Vac 0~12.5 A 150 W 92% EUV-150S012ST

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

MTC Series 15 W AC/DC Switching Power Supply Module Medical

HEC-40LTN-XXPSCA Rev A

Max. Output Power. Typical Efficiency (2) 12 Vdc 90 ~ 305 Vac 0~22.9 A 275 W 91.5% EUV-300S012ST

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Typical Efficiency (1) 24 Vdc 90 ~ 305 Vac 0~4.00 A 96 W 87% EUV-096S024SV. 36 Vdc 90 ~ 305 Vac 0~2.66 A 96 W 88%

General. Environmental. EMC & Safety

HEC-30/35LTA-33TDAA Rev A

HEC-35LTA-XXTSAA Rev A

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

For more information, please visit the product page. output. output current max (A)

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Output Voltage Range ma ma 700 ma 176~305 Vac 160~357 Vdc 250W 93% 0.98 EBD-255S105DV

Load (2) Single or Dual

PDAM500 Series 500W Power Supply

Max. Output Power. Efficiency (1) 110Vac 220Vac

75W Constant Current (700mA) LED Driver

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

NFF Series. CoolX600 NFF Series Cool. Patent Pending Resonant Technology. NFF Series; No Fan Featured

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

HEC-70LCN-350TDAF Rev B

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Output Current Range. Max. Output Power. 12 Vdc 90 ~ 305 Vac 10.8~13.2V 0~2900mA 35 W 82% EUV-035S012ST(3)

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Load (2) Single or Dual

Product Specification sheet

VMS-300A - XX - XXX - X

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

Features. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Environmental. Electrical Specifications at 25 O C E Output Constant Current

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Output Voltage* (nom.)(adjustable)

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

Electrical Specifications

Transcription:

VPS-030AAC Series / VPS-030AAC 030AAC Highlights & Features VPS-030AAC05, 12, 15, 24 Meet DOE Level VI & ErP 2017 Low touch current. Suitable for type BF applications Detachable AC plug with multiple country options Class B EMI and 4th Edition Immunity Compliant Safety rated for medical and IT applications IP22 ingress protection rating 2 MOPP isolation 500K hours MTBF 3 years warranty Safety Standards CB Certified for worldwide use General Description Model Number: VPS-030AAC Unit Weight: 150 grams Dimensions (W L H): 53.5 88.0 27.5 mm 2.11 3.46 1.08 inch The VPS series of external power supply comes with universal AC input at 85Vac to 264Vac. Other features include low touch current, risk management report available and the electric shock protection comply with 2 MOPP. The VPS series is certified for EMC standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN 55022 for Information Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used. The VPS series come with both medical and ITE safety approvals including UL/cUL and IEC-60950-1 CB certification as a Limited Power Source (LPS), and CCC approval. Designs are fully compliant with RoHS Directive 2011/65/EU for environmental protection. Model Information Model Number Input Voltage Range Efficiency Level Rated Output Voltage Rated Output Current VPS-030AAC05 85-264Vac Level VI 5Vdc 3A VPS-030AAC07 Level V 7Vdc 3A VPS-030AAC12 Level VI 12Vdc 2A VPS-030AAC15 Level VI 15Vdc 2A VPS-030AAC24 Level VI 24Vdc 1.25A Model Numbering 1 VPS 030 AAC AA Family Code Output Voltage (Single Output) 1), 2) Revision Code Power Supply Max wattage in the product series (may be lower at some voltage) - 05 for 5V - 07 for 7V - 12 for 12V All parameters are specified at 25 C ambient unless otherwise indicated. - 15 for 15V - 24 for 24V 1) 1st digit: DC plug type and output cable length. A for 2.1 5.5 10 mm DC plug, and 1200 mm cable length. 2) 2nd digit: Country duck-head type (A_ China, B_ United States, C_ European, D_ United Kingdom, E_ Australia, G_ Korea, H_ India, J_ Argentina, K_ Brazil, M_ South Africa)

VPS-030AAC Series / VPS-030AAC Specifications Input Ratings / Characteristics Model Number VPS-030AAC05 VPS-030AA07 VPS- 030AAC12 VPS-030AAC15 VPS-030AAC24 Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current (max) 115Vac 0.5A 0.6A 0.8A 0.8A 0.8A 230Vac 0.3A 0.4A 0.6A 0.6A 0.6A Average Efficiency (min) 115Vac 230Vac 81.4% 81.4% 86.21% 87.0% 87.0% Standby Power (max) 115Vac 230Vac 0.1W 0.1W 0.1W 0.1W 0.1W Inrush Current (typ.) 60A @ 115Vac and 230Vac Touch Current (max) 0.1mA @ 264Vac NC 1), 0.3mA @ 264Vac SFC 2) Output-PE (protective earth) 0.1mA @ 264Vac NC 1), 0.5mA @ 264Vac SFC 2) leakage current for Type BF application (max) 1) NC: Normal condition 2) SFC: Single fault condition Model Number VPS-030AAC05 VPS-030AA07 VPS- 030AAC12 VPS-030AAC15 VPS-030AAC24 Output Ratings / Characteristics Nominal Output Voltage 5Vdc 7Vdc 12Vdc 15Vdc 24Vdc Output Voltage Tolerance Output Current 3A 3A 2A 2A 1.25A Output Power 15W 21W 24W 30W 30W Line Regulation ±1% Load Regulation ±5% Ripple & Noise (max) 100mVpk-pk @ Rated load 100mVpk-pk @ Rated load 150mVpk-pk @ Rated load 200mVpk-pk @ Rated load 200mVpk-pk @ Rated load Start-up Time (max) 3000ms @ 115Vac Hold-up Time (min) 10ms @ 115Vac Dynamic Response (Overshoot & ±10% @ 50-100% load Undershoot O/P Voltage) Capacitive load (max) 4700uF *Periodic and Random Deviation. Ripple & Noise measurement circuit with 20MHz BW PSU 5cm 0.47uF Ceramic 10uF Electrolytic Load Scope 2 Test Fixture All parameters are specified at 25 C ambient unless otherwise indicated.

Specifications Mechanical Model Number VPS-030AAC05 VPS-030AA07 VPS- 030AAC12 VPS-030AAC15 VPS-030AAC24 Case Chassis Case Cover Dimensions (W L H) Unit Weight Indicator Cooling System Terminal PC PC 53.5 88.0 27.5 mm (2.11 3.46 1.08 in) 150 grams (5.3 ounces) NA NA Input Detachable type AC plug Output Barrel type. Dimensions 2.1 5.5 10 mm (see page 5) Environment Surrounding Air Temperature Operating Humidity Operating Altitude Shock Test (Non-Operating) Vibration (Operating) Operating 0 C to +40 C Storage -40 C to +85 C 5-95% RH (Non-Condensing) 5,000 meters (16400 feet) 50G, 11ms, 3 shocks for each direction 5-500Hz, 2.09Grms, 20 minute for each three axis Protections Overvoltage (max) 150%, Latch Mode Overload / Overcurrent (max) Over Temperature Short Circuit Degree of Protection Protection Against Shock 250% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) IP22 Class II Reliability Data MTBF (min) 500K Hours based on Telecordia SR-332 (at 100Vac, Max. load and 25 C Ambient) 3 All parameters are speciÿed at 25 C ambient unless otherwise indicated.

Specifications Model Number VPS-030AAC05 VPS-030AA07 VPS- 030AAC12 VPS-030AAC15 VPS-030AAC24 Safety Standards / Directives Medical Safety ITE Safety CE Material and Parts Galvanic Isolation Input to Output IEC 60601-1 Edition 3.1 (2012), EN60601-1 (2006) + A11 + A1 + A12, CAN/CSA-C22.2 NO. 60601-1:14, ANSI/AAMI ES60601-1:2005/(R)2012 IEC60950-1 (Ed.2,2005), GB4943.1-2011, GB9254-2008, GB17625.1-2003 MDD Directive 93/42/EEC RoHS Directive 2011/65/EU Compliant 4000 Vac EMC EMC / Emissions Harmonic Current Emissions IEC61000-3-2 EN55011/EN55022,FCC Title 47:Class B Meet Class A limit Immunity to EN 55024, EN 61000-6-1, EN 55014-2 Voltage Flicker IEC61000-3-3 Radiated Field IEC61000-4-2 Level 4 Criteria A Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC60601-1-2 Level 3 Criteria A 1) 80MHz-1000GHz, 10V/m AM modulation Electrical Fast Transient / Burst IEC61000-4-4 Criteria A 80MHz-2700MHz, 10V/m AM modulation 385MHz-5785MHz, 28V/m Pulse mode and other modulation Level 3 Criteria A 1) : 2kV Surge IEC61000-4-5 Level 3 Criteria A Differential Mode 3) : 1kV Conducted IEC61000-4-6 Level 2 Criteria A 150kHz-80MHz, 3Vrms, 6Vrms at ISM bands and Amateur radio bands Power Frequency Magnetic Fields IEC61000-4-8 Criteria A Magnetic field strength 30A/m Voltage Dips IEC61000-4-11 30% 10ms Criteria A 1) 60% 100ms Criteria B 2) 100% 5000ms Criteria B 2) Voltage Dips IEC60601-1-2 2), 4) Criteria B 30% 500ms Criteria A 1) 100% 10ms at step: 45 degree Criteria B 2) 100% 20ms Criteria B 2) 100% 5000ms 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. 3) Symmetrical: Differential mode (Line to line) 4) Compliant with IEC-60601-1-2 4th edition requirements. 4 All parameters are speciÿed at 25 C ambient unless otherwise indicated.

Block Diagram Dimensions W H H: 53.5 88.0 27.5 mm Note: The plug s polarity is 5

Duck Head Type: AU type BZ type EU type UK type CN type US/JP type KR type 6

Functions Start-up Time The time required for the output voltage (Vo) to reach 90% of its set value, after the input AC voltage is applied. Rise Time The time required for the output voltage (Vo) to change from 10% to 90% of its steady state value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Inrush current is the input current that occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Dynamic Response The power supply output voltage will remain within ±3% of its steady state value, when subjected to a dynamic load change from 50 to 100% of its rated current. t 25 C ambient unless otherwise indicated. 7

Overload & Over current Protections The power supply s Overload (OLP) and Over current (OCP) Protections will be activated when output current is between 110% and 130% of I O (Max load). Upon such an occurrence, V O will start to drop. Once the power supply has reached its maximum power limit, the protection will be activated and the power supply will go into Hiccup mode (Auto-Recovery). The power supply will recover once the fault condition causing the OLP and OCP is removed and I O is back within the specified limit. Overvoltage Protection The power supply s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under Protections. Power supply will hiccup mode, and require removal/re-application of input AC voltage in order to restart. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into hiccup mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. Additionally, if the I O is <130% but >110% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into hiccup mode until the fault is removed; and, the input voltage is removed, then reapplied. Short Circuit Protection (Auto-Recovery) The power supply s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in Hiccup mode, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. t 25 C ambient unless otherwise indicated. 8