wprime TM Series 280W-CI ULTRASONIC WATER METER

Similar documents
Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Release A Member of the

Technical Specifications

SN+ MID MASTER + APPLICATION WATER METERS

Advanced instrumentation solutions crafted with highest precision

EnduroFlow TM Series EF12

A Member of the. Integrated Metering Technologies

MID MP-01, MP WATER MEASUREMENT

A T u n e d M e a s u r e

User s Manual tprime Series 280T Ultrasonic Heat Meter

flowiq 3100 Data sheet

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

OPTIFLUX 1000 Technical Datasheet

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

WATERFLUX 3070 Technical Datasheet

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Model Sono-Trak Transit Time

WATERFLUX 3000 Quick Start

Heat meter Q heat 5 US

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

WESAN WP E ELECTRONIC METER WOLTMAN

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

WATERFLUX 3000 Quick Start

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Innovation through precision, quality and performance. ARAD AMR Solutions. AMR Ready. No Moving Parts

Flow Monitoring Product Guide

SonoMeter 31 Energy Meters

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

flowiq 3101 DATA SHEET

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

INSERTION paddle wheel flowmeter for continuous flow measurement

HANWELL UTILITY DATA SHEET

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

Nubis propeller water meter with horizontal impeller axle

SONOMETER TM 1100 Ultrasonic compact energy meter

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

Advanced instrumentation solutions crafted with highest precision

SONOMETER TM 1100 Ultrasonic compact energy meter

OPTIFLUX 5000 Technical Datasheet

Ambient Conditions. Operating Conditions. Pressure

WELCOME SMART WATER NETWORKS SENSORS & COMMUNICATIONS FOR. Andy Newland Regional Sales Director Asia Pacific

OPTIMASS 1000 Technical Datasheet

INLINE flowmeter for continuous flow measurement

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

INLINE flowmeter for continuous flow measurement

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS


Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Digital flow transmitter for continuous flow measurement

Proven Measurement for A World of Applications

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

Ultraclean Flow Measurement!

Advancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

SMART METERS ADVANCES IN WATER METER TECHNOLOGY BILL KASPER NORTH PENN WATER AUTHORITY

2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals

EN-2018 MAGNETIC FLOW METERS

ULTRAFLOW TS Application OIML R75 DS/EN 1434

flowiq 3100 Data sheet

Electromagnetic Flow Transmitter

FLOMID FX Electromagnetic Flowmeter

EverBlu. Wireless fixed data collection system

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

OPTIFLUX 2000 Technical Datasheet

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

flowiq 2100 Data Sheet

INLINE flowmeter for continuous flow measurement

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Infocal 9 Energy calculator

Digital flow ELEMENT transmitter for continuous flow measurement

NUBIS. R t o WATER MEASUREMENT

OPTIFLUX 5000 Technical Datasheet

Technical Description. flowiq Water Meter

Applications Features

Flow Measurement SITRANS F US Inline

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ULTRASONIC FLOW METER FT101

Brunata Optuna H. Properties. Counter

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

HTTF Transit Time Ultrasonic Flow Meter

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

Digital flow ELEMENT transmitter for continuous flow measurement

Digital conductivity transmitter

March Sales Update TRAVIS SMITH

Flow Measurement SITRANS F US Inline

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

MULTICAL 21 & flowiq 2101

Bulk water meter. All that c ou n t s. EnergyMetering

RISONIC Ultrasonic Transit Time Flow Measurement For Filled/Partially Filled Pipes For Open Channels. Supply Disposal Hydraulic Power Station

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Transcription:

MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water meter will provide sustained flow accuracy for the life of the meter while providing connection to smart AMR/AMI solutions. Applications Any Application that requires high accuracy across all flow rates for Revenue Billing Municipal, Commercial, and Distribution applications including reclaim and irrigation water requirements Commercial buildings: Malls; Campus; Hospitals, Industrial parks; Airports, Facilities Industrial water: Steel, Heavy Manufacturing plants; Power Plants; Food & Beverage Features & Benefits 280W-CI ultrasonic water meters provide a wide performance range featuring robust, and durable commercial and industrial design for water measurement Electronics, transducers and cables are all encapsulated in a heavy-duty enclosure with IP68 rating No moving parts. Dependable ultrasonic performance without maintenance Not affected by water impurity. Solves the challenges in harsh environments, such as the Middle East and Africa Excellent performance at all flow rates Accuracy does not degrade over the life of the meter. Exceed ISO4064 Class D and AWWA C750 Fire service (Commercial) Leak and Tamper detection, DMA (District Metered Area) leakage detection system AMR/AMI projects which require flow accuracy with low life cycle costs Multi-path technology improves accuracy and reduces straight-pipe run requirement 10 Year battery life Bi-directional flow. No strainer required Does not measure entrained air in pipe Unaffected by magnetic interference Low pressure drop DN50 (2 ) to DN250 (10 ) sizes Cold water or hot water up to 60 C (140 F) Tamper-proof design AMR/AMI ready with pulse, M-Bus, Modbus, BACnet, or Wireless interface Optional SpireCapture AMR/AMI and Billing solution DS-280W-CI-1309_Rev.1 Spire Metering Technology LLC, 15 Craig Road, Acton, MA 01720, USA Tel +1 978 263-7100 / 888 738-0188 (toll-free) Fax +1 978 418-9170 sales@spiremt.com www.spiremt.com

A member of the wprime TM Series, the 280W-CI Ultrasonic Water Meter is specially designed for commercial and industrial water metering applications where the environment is challenging and traditional mechanical water meters fail. 280W-CI is carefully engineered to offer robust performance in harsh environments. The flow sensor utilizes a crystal to generate an ultrasonic signal. There are no moving parts to wear out, over time, as in traditional mechanical meters. The electronics, transducers and cables are all encapsulated in a heavy-duty metal enclosure which is IP 68 rated. It is suitable for both outdoor and indoor applications and anywhere the meter may be submersible. The 280W-CI offers the most advanced water flow measurement by using state-of-the-art multi-path ultrasonic technology. It employs at least 4 pairs of ultrasonic transducers to interrogate the flow from different position, so that flow profile distortion has minimal impact on the measurement results. This is a significant improvement compared to singlepath ultrasonic flow meters, because it is very common in real applications that there is not enough straight-pipe run after an elbow, a valve or a pump, or the sensor installation is not perfectly aligned with existing pipe line. In those scenarios, turbulence (swirl) or other type of secondary flow could cause errors with singlepath flow meters. The technical specification of the 280W-CI water meter meets the ISO 4064 (or OIML R49) water meter standards for Class D accuracy, and exceeds the AWWA C750-10 water meter standard. The operational temperature ranges from 0.1 C (32.18 F) to 60 C (140 F) including safety temperature up to 95 C. The large display can be set to display the flow total, flow rate, working time, leakage alarm, reverse flow, and more. The meter also has a remote readout which could be configured as pulse, M-Bus, RS485/Modbus, 4-20mA, BACnet, or, wireless. Spire Metering s 280W-CI Ultrasonic Water Meter stands out among the competition due to its rugged design, multi-path technology, wide dynamic range and extensive AMR functions. The 280W-CI performs reliably when there the water has high particulate or the environment is harsh. Both commercial and industrial installations can profit from the advantages of the wearfree water flow measurement, precision, and operation security and long service life. 2 MEASURE TODAY. ENSURE TOMORROW

Operating Principle The wprime series ultrasonic water meter consists of a flow-cell, a pair of ultrasonic flow transducers and an integrator. The transducers are firmly mounted on the flowcell at the optimal position. As illustrated on the right, the transducers face each other with one on the upstream, and the other on the downstream. Only ultrasonic pulses are used to interrogate the flow which enables the meter to have no moving parts. Since the principle is based on the transit-time difference instead of transittime, all the interfering factors, such as the temperature, pressure, solids concentration and water quality, are cancelled out. The end result is an ultrasonic metering system which is inherently robust! Unique Multi-path Technology The integrator (or calculator) controls the two ultrasonic transducers to transmit and receive ultrasound in an orderly fashion to conduct precise flow measurement. Specifically, it operates the two transducers which transmits a pulse of ultrasonic energy into the water flow toward the opposite transducer. The integrator then detects the pulse signal which has traveled within the flow tube, and then received by the opposite transducer. With advanced digital signal processing technology, the integrator measures the arrival time (or transit-time) of each pulse signal precisely. In real application, it is not easy to install the flow sensor perfectly in line with the pipe line. A small misalignment could cause flow profile distortion inside the flow sensor, thus, cause significant measurement errors. Spire Metering developed a unique multi-path technology to solve this problem. Two or four pairs of ultrasonic transducers are mounted on the flow sensor body to interrogate the flow from two/four different paths (refer to the above figure.) A flow calculation algorithm based on fluid dynamics theory is then used to derive an average flow reading with improved accuracy. Since the transit-time difference between the two pulses is directly proportional to flow velocity, it is used to calculate the flow velocity and flow rate. This is accompanied by combining it with the geometry of the flowcell and fluid dynamics theory. MEASURE TODAY. ENSURE TOMORROW 3

Automatic Meter Reading The wprime series water meter offers a variety of interface options, such as M-Bus, RS485/ Modbus, BACnet, Pulse, as well as wireless (GSM, GPRS and Radio). It is very flexible to be integrated into an AMR/AMI system. Spire Metering also offers a complete range of AMR/AMI solutions as well as an integrated billing system. The SpireCapture system is a cutting edge fixed automatic meter reading system which integrates both wired and wireless AMR/AMI technologies. The system provides a unified platform for meter reading and data management through M-Bus networks, RF wireless networks, GSM networks, GPRS networks as well as TCP/IP networks. In addition, it works seamlessly with Spire Metering s billing software to make data exchange easy, fast and reliable. comprehensive usage information as well as timely, high-resolution meter reading. This data enables gas, water, heat and electric utilities to eliminate on-site visits and estimated reads, reduce theft and loss, implement time-of-use billing, and profit from all of the financial and operational benefits of fixed-network AMI/AMR. For information on AMR/AMI parts, such as concentrators, repeaters, protocol convertors, data collection devices and more, please contact : solutions@spiremt.com SpireCapture is an advanced, highly robust meter reading solution that delivers Reservoir Source Water treatment plant Pump station A typical DMA (District Metered Area) Leakage Detection System Water tower Pump Consumer meters 4 MEASURE TODAY. ENSURE TOMORROW

Technical Specifications Nominal Size DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 Dimension L (mm) 200 200 225 250 250 300 350 450 500 W (mm) 175 185 200 220 250 285 340 405 460 H1 (mm) 178 186 203 209 227 245 274 300 348 H (mm) 263 276 292 315 348 383 438 480 578 Q4 (m 3 /h) 31.25 50 78.75 125 200 312.5 500 787.5 1250 Q3 (m 3 /h) 25 40 63 100 160 250 400 630 1000 Q2 (m 3 /h) 0.16 0.256 0.4032 0.64 1.024 1.6 2.56 4.032 6.4 Q1 (m 3 /h) 0.1 0.16 0.252 0.4 0.64 1 1.6 2.25 4 Sound Path Pipe Joint Body Material Dualpath Quad-path Flange (Default: DIN) Nut4-M16 Nut4-M16 Nut8-M16 Nut8-M16 Nut8-M16 Nut8-M20 Nut12-M20 Nut12-M24 Nut12-M24 Ductile Iron (default) or 304 SS Ductile Iron Carbon Steel L H1 H L W MEASURE TODAY. ENSURE TOMORROW 5

Electrical Data Power Supply: Battery, 3.6V, Lithium Replacement Interval: 10 years at tbat<30 C (86 F) Network Power Supply: Automatically switch to M-Bus or RS485 power if available to save battery Power Consumption: <0.1W Backup Power Supply: Internal SuperCap Communication Interface: M-Bus, RS485/MODBUS, Pulse, BACnet, Radio or external GSM/ GPRS CE approval: EN61326-1:2006 Accuracy / MPE (Maximum Permissible Error) MPE according to OIML R49 / ISO4064 ±2 in the range Q2 Q < Q4; ±5 in the range Q1 Q Q2 Metrology Data Accuracy Class: 2 (according to ISO4064 / OIML R49) Metrological Class: D (according to ISO4064 / OIML R49) Range Q3/Q1: 250 Mechanical Data Environmental Class: B. Optional A Electromagnetic Class: E1 Environmental Temp: 0~55 C(32~131 F) Permissible Flow Temp: 0.1~60 C (32.2~144 F) for long term and up to 95 C (203 F) for short term Enclosure Protection: IP68 Integrator Detachable: No Lid Cover Protection: Yes Pressure: PN16 Pressure Loss The pressure loss of a flow sensor is proportional to the square on the flow : Δp = k x Q 2 Here Δp is pressure loss, Q is volume flow rate and k is the coefficient. All meters have Δp less than 0.63bar at Q3, meet ISO4064 / OIML R49 standard and AWWA standard. 6 MEASURE TODAY. ENSURE TOMORROW

Order Specifications 280W CI Meter Size Metric DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 English IN2 IN2.5 IN3 IN4 IN5 IN6 IN8 IN10 IN12 Output Interface Pulse 0 M-Bus 1 RS485/Modbus 2 BACnet 3 RF wireless 4 GPRS wireless 5 GSM wireless 6 Other, please specify 7 Flange DIN Flange ANSI Flange Other, please specify A B C Sensor Body Material Ductile Iron (default for DN50-DN125) 1 304 SS (optional for DN50-DN100) 2 Carbon Steel (for size >= DN250) 3 Unit System Metric System English System A B MEASURE TODAY. ENSURE TOMORROW 7

Memo About Spire Metering Technology Formerly Shenitech, Spire Metering is a global leader in flow and energy management solutions. Through continuous innovation, we transform complex ultrasonic technology into affordable, reliable solutions for accurate flow and energy measurement. Spire Metering offers water, heat, electricity and gas meters as well as AMR/AMI solutions. To find out how we can help today, please tell us about your application. 8 MEASURE TODAY. ENSURE TOMORROW