Manatronics 110V / 100 Amp Load

Similar documents
Manatronics 48V / 300 Amp Load

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Signal Conditioning Amplifier

COM-POWER OPERATION MANUAL ACS W

AUM FAMILY Programmable DC Power Supplies

Model 7000 Low Noise Differential Preamplifier

Signal Conditioning Amplifier

Solid State General Communication Power Amplifier

LM2935 Low Dropout Dual Regulator

Looking For A High Power, Low Profile Power Supply? KEPCO. Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY

1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)

SIL20C SERIES. Single Output. SIL20C Series 20 A DC-DC Converter C Class Non-Isolated

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

Power Supply Unit (550W)

Model 3102D 0-2 kv H.V. Power Supply

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Signal Conditioning Amplifier

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Agilent E3633A and E3634A DC Power Supplies

SMT20C SERIES. Single Output TÜV. SMT20C Series 20 A DC-DC Converter C Class Non-Isolated

DSSIU-6-1U-V. Features VOM:

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

Model Quality in Test and Measurement Since 1949 OUTSTANDING PERFORMANCE DESCRIPTION APPLICATIONS ADDITIONAL FEATURES

SM2000 TECHNICAL DESCRIPTION

LM2925 Low Dropout Regulator with Delayed Reset

Npaq Series Drive Racks

UNISONIC TECHNOLOGIES CO., LTD LR2126

CA3140, CA3140A. 4.5MHz, BiMOS Operational Amplifier with MOSFET Input/Bipolar Output. Description. Features. Applications. Ordering Information

NE/SA5234 Matched quad high-performance low-voltage operational amplifier

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

Lock-In-Amplifier Module

Constant Voltage and Constant Current Controller. Features

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Dale Power Solutions Ltd

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db

AIM & THURLBY THANDAR INSTRUMENTS. DC Electronic Load, 80A, 80V, 300W

FEATURES: Affordable, reliable power perfect for DRM Series Passive Loudspeakers, installations, and production audio systems

Zero Drift, Unidirectional Current Shunt Monitor AD8219

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

Ultra Wide Band Low Noise Amplifier GHz. Electrical Specifications, TA = +25⁰C, With Vg= -5V, Vcc = +4V ~ +7V, 50 Ohm System

MODEL 503 DC BRUSHLESS SERVO AMPLIFIER

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

Low Noise 300mA LDO Regulator General Description. Features

CA5260, CA5260A. 3MHz, BiMOS Microprocessor Operational Amplifiers with MOSFET Input/CMOS Output. Features. Description.

Micropower Precision CMOS Operational Amplifier AD8500

AD557 SPECIFICATIONS. T A = 25 C, V CC = 5 V unless otherwise noted) REV. B

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

SGM W Fully Differential Audio Power Amplifier with Selectable Shutdown

HITEK POWER OLS10K SERIES

W DC ELECTRONIC LOAD INSTRUCTION MANUAL

Current Transducer CTSR 1-P = 1A

HMC914LP4E. limiting amplifiers - smt Gbps LIMITING AMPLIFIER w/ LOSS OF SIGNAL FEATURE. Typical Applications. General Description

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Single-Supply, Rail-to-Rail, Low Power, FET Input Op Amp AD820

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

id id mA, Low Dropout, Low Noise Ultra-Fast With Soft Start CMOS LDO Regulator Features General Description Applications

Model 2450 Interactive SourceMeter Instrument

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

+2.7V to +5.5V, Low-Power, Triple, Parallel 8-Bit DAC with Rail-to-Rail Voltage Outputs

Agilent E3631A Triple Output DC Power Supply

Model Operating Manual

DCM20 Series. Three-Function DC Power Meters. DCM20 DISPLAY PRODUCT OVERVIEW FEATURES

High Precision 10 V IC Reference AD581

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

1140LA Broadband Power Amplifier

Power Supplies 3. SDN-C Compact DIN Rail Series

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

TSC1021. High-side current sense amplifier. Related products. Applications. Features. Description

AB (2 PLACES) 30 NC 31 P 33 V 34 W

1.2 V Precision Low Noise Shunt Voltage Reference ADR512

A 500 Broadband Power Amplifier

DUAL OPAMP AND VOLTAGE REFERENCE General Description. Features. Applications

High Common-Mode Voltage, Programmable Gain Difference Amplifier AD628

AD8218 REVISION HISTORY

High Resolution, Zero-Drift Current Shunt Monitor AD8217

ABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications.

Precision Micropower Single Supply Operational Amplifier OP777

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

Precision, Micropower, Low-Dropout, SC70 Series Voltage Reference

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Telonics Pro Audio. Telonics PA-4200/PA-200 Stereo Power Amplifier. Users Manual Telonics, Inc. All Rights Reserved PB Rev F

2014 Short Form Test and Measurement Catalog

DC Electronic Loads 8500 series

HIGH POWER OP-AMP MSK0021FP

4W Ultra Wide Band Power Amplifier 0.1GHz~22GHz

Brushless DC Motor Controller Specification Assemblies 025F0248

AX6220Z/AX6240Z. Energy-Efficient, DSP-Powered and Ethernet/USB-Controlled 1000/900-Watt 70/100 V High-Impedance Power Amplifier.

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

LM117HV/LM317HV 3-Terminal Adjustable Regulator

AIM & THURLBY THANDAR INSTRUMENTS

HITEK POWER OLS10KD SERIES

Self-Contained Audio Preamplifier SSM2019

Thank you very much for choosing Shuguang Audio Classic Series vacuum tube amplifier

2W Ultra Wide Band Power Amplifier 0.2GHz~35GHz. Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Units. Frequency Range

DACPORT Low Cost, Complete P-Compatible 8-Bit DAC AD557*

Features. Applications

Transcription:

Manatronics 110V / 100 Amp Load For Battery Discharge testing and Power Supply testing 22 nd Jan. 2016 Model No. BD12-110P Product Datasheet 110V / 100 Amp Electronic Load Features: Quality Product Rugged and Reliable Design Full Remote control Option (suitable for Ethernet/LAN control) Very Cost effective Microprocessor controlled 100 Amps at 117V (continuous rating) 11.7kW Rated 100 Amps down to 92V and 90 Amps down to 83V Portable very light weight Load Small case size with carrying handles on the front panel Continuously variable current Constant Current operation is standard Options for CP, CR, CV modes. Completely powered from batteries. Two LCD digital panel meters for Voltage and current Thermally safe Fan fail detector on all fans / Air flow blockage detectors Overvolt protection Intelligent Load feature: has built-in LVD to remove load at "End Voltage" Selectable "End Voltage" prevents deep discharge and possible damage Shunt output is available Remote enable / disable (suitable for UPS control) Anderson SB Series connector for DC power connection

Introduction This particular Load has been designed to operate with 110V battery systems and is extremely cost effective. The load is continuously rated at 100 Amps at up to 117V DC, i.e. 11.7kW. The standard model has constant current operation. There is an option available for Constant Power, Constant Resistance and Constant Voltage. The mode selection will be via the front panel. The load current is continuously variable over the entire current range. The current is controlled via two knobs on the front panel, one coarse and one fine control. As standard there is an in-built LVD, (Low Voltage Disconnect). It is possible to select the "End Voltage" per cell from 1.55V PC up to 1.90V PC. When enabled the load monitors the overall battery Voltage and when it drops to the "End Voltage" it will automatically disconnect the load and the current will drop to zero. Thus, the Load now becomes an intelligent Load, in that if it left unattended it will prevent deep discharge of the batteries and hence prevent any possible damage to them. When this load is used in conjunction with the Manatronics Data Logger DLM-09, (which is recommended), the "End Voltage" will be programmed from the Logger and this will automatically disconnect the load when the Logger senses that the "End Voltage" has been reached. This feature will override the LVD in the load. The Load is completely powered from the Batteries under test, i.e. no mains supply is required. Therefore tests are not terminated part way through by a temporary mains power outage. The unit uses forced air cooling. The Load is housed in a compact, rugged case with carrying handles and is ultra-lightweight for the power rating and is also completely portable. The Load may be left on site, unattended, for an extended period of time, if required. The case has various rear panel connectors and the front panel has two LCD panel meters, one for the DC input Voltage and one for the load current. There are also eight LED s to indicate the status of the Load. The load has been designed to be very reliable, easy to use and suitable for field use. It is thermally safe and has fan fail detectors on all fans together with air blockage detectors. The DC input has overvoltage protection included and there is an option for a Fuse to be included. The DC power connection is via an Anderson SB Series 350 Amp connector on the rear panel. Monitor points are included on the front panel for access to the internal shunt. This is also provided via a D type connector on the rear panel. An amplified signal from the internal shunt is provided via a D type connector on the rear panel. Control selection is made from the front panel between Load ON, Load OFF, Data Logger Control, External Input Control, (e.g. suitable for UPS control). The rear panel has a connector to link to the Manatronics Data Logger DLM-09 or for an external load on / off control, (e.g. suitable for UPS control).

Applications Battery discharge testing. Power Supply testing. Applications for Mains powered version - see EL12-110 M Telecom Rectifier testing. All purpose Power Supply testing Load bank for Burn-in room facility

2016 Manatronics Pty Ltd Model No. BD12-110P Product datasheet 110V 100A Portable Battery Discharge Model Specification Absolute Maximum Ratings DC Input Voltage... -0.5 to +120V DC input current. 101A Max Voltage between the chassis and the DC connector (SB350). 50V ac or 120Vdc CAUTION: Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the unit. This is a stress only rating and operation of the unit at or above these limits is not implied. Electrical Specifications (assumes TA= -10 C to +40 C unless otherwise stated) Parameter Min Typ Max Units Comments DC Input Voltage 0 117 V DC Input Current 0 100 A Common to all Modes (e.g. CC, CP, CR and CV). Min Voltage required to achieve max current 83.7 V (see next line) Minimum series resistance 1.5 Ohm Constant current Mode Current range 0.7 90 A Demand sensitivity 20 A/V i.e. 4.5V demand input gives 90A. Demand sensitivity tolerance +/-0.1 % Constant power mode Power range.078 11.7 kw At 117V input Demand sensitivity W/ V 1V demand input sets W load. Constant resistance mode Resistance range 0.92 167 Ohm Demand sensitivity Constant voltage mode Voltage range 83.7 117 V Demand sensitivity See constant resistance mode text. See constant Voltage mode text. Shunt Output Accuracy (worst case) 0.2 % 50mV 500A LVD Accuracy 2 % N.B. Modes are CC CP CR or CP.

2016 Manatronics Pty Ltd Model No. BD12-110P Product datasheet 110V 100A Portable Battery Discharge Model Specification Absolute Maximum Ratings Logic input signals on rear D9 connector Enable Input Voltage... -2.0 to +14V wrt to Load DC ve. Mode select (LSB) Input Voltage -2.0 to +14V wrt to Load DC ve. Mode select (MSB) Input Voltage -2.0 to +14V wrt to Load DC ve. Fault output Voltage. -2.0 to +16V wrt to Load DC ve. Demand inputs (+/-).... -10 to +10V wrt to Load DC ve. 0V reference on D9 connector 50mA CAUTION: Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the unit. This is a stress only rating and operation of the unit at or above these limits is not implied. Electrical Specifications (assumes TA= -10 C to 40 C unless otherwise stated) Demand input Min Typ Max Units Comments CMRR of differential demand input stage 50 db For DC Common mode range of differential -10 +10 V wrt load -ve DC input demand input stage Demand current; temperature drift. 0.5 % Over the temperature range Demand current offset 15 ma Demand current linearity 0.2 % Demand Voltage, 3dB cutoff frequency, for CC, CP and CR Modes. Demand Voltage, step response, for CC, CP and CR Modes. Demand Voltage, 3dB cutoff frequency, for CV Mode only. 800 Hz can be increased at factory up to 20kHz. 1 ms 10% to 90% rise or fall 1.59 Hz Logic inputs Range Input Voltage (High Level) 7 V Internal pull up resistor 3k3 to +12V Range Input Voltage (Low Level) 4 V Enable Input Voltage (High Level) 10 V Internal pull up resistor 2k2 to +12V Enable Input Voltage (Low Level) 7 V Mode select (LSB or MSB) Input Voltage (High Level) 7 V Internal pull up resistor 22k to +12V Mode select (LSB or MSB) Input Voltage (Low Level) 3.5 V

2016 Manatronics Pty Ltd Model No. BD12-110P Product datasheet 110V 100A Portable Battery Discharge Model Specification Min Typ Max Units Comment Logic outputs Fault output high (Iout = 10uA) 11 V Fault output low (active) (sink 30mA) 1.2 V Static Characteristics Noise and ripple, psophometric 0.7 ma RMS Noise and ripple, psophometric 0.1 mv RMS see note 1. Noise and ripple, wideband 3 ma RMS Noise and ripple, wideband 0.2 mv RMS see note 1. Settling time, 0 100A step 300 us DC Input Resistance of load 1 Meg Ohm When off without fans running. Note 1. Measured at the DC input terminals with a 110V battery connected in CC mode. PHYSICAL AND OTHER SPECIFICATIONS Dimensions 482 wide x 267 (6U) high mm x 415 deep Weight 21.5 kg Dimensions inches Weight 47.5 lb. Specifications herein, are subject to change without notice. This publication supersedes and replaces all information previously supplied.

Options: Remote control box, (in place of front panel controls, for ease of use, when the load unit is under a bench or some distance away. Module for Constant Power, Constant Resistance and Constant Voltage. 19 (inch) Rack Mount case Ordering Information Model number: BD12-110P Protection Fan fail detectors Over Temperature detector Air flow blockage detectors Overvoltage detector that switches the load current to zero. DC Power input connectors Anderson SB Series Connector External enable Both active high and low inputs provided. 110V / 100A Model BD12-110P Operating Area 120 Max Voltage Limit 115 110 DC Input Voltage 105 100 95 90 Availble Load Area Current Limit 85 80 Unavailable Area 75 0 20 40 60 80 100 120 Load Current (Amperes)