The Hemispherical Receptor Incident Light Exposure Meter

Similar documents
Norwood s dome: a revolution in incident-light photographic exposure metering

Determining MTF with a Slant Edge Target ABSTRACT AND INTRODUCTION

Exposure Control in the Canon Wireless Flash System

Gray Point (A Plea to Forget About White Point)

mastering manual week one

The Bellows Extension Exposure Factor: Including Useful Reference Charts for use in the Field

Robert B.Hallock Draft revised April 11, 2006 finalpaper2.doc

Some Notes Concerning FILM SENSITOMETRY AND EXPOSURE (Version /09/27) b-wtechnik.pp7.uk. Contents. Introduction. G2 and Overall Dynamic Range

This histogram represents the +½ stop exposure from the bracket illustrated on the first page.

ISO INTERNATIONAL STANDARD. Photography Electronic still-picture cameras Methods for measuring optoelectronic conversion functions (OECFs)

ISO INTERNATIONAL STANDARD. Photography Electronic still-picture cameras Methods for measuring opto-electronic conversion functions (OECFs)

FIM FUNDAMENTALS OF FILMMAKING CINEMATOGRAPHY

Appendix III Graphs in the Introductory Physics Laboratory

To do this, the lens itself had to be set to viewing mode so light passed through just as it does when making the

PLANT + SHOOT GARDENER S PHOTOGRAPHY SERIES (GPS) GET GREAT GARDEN PHOTOS ON A CLOUDY DAY

Wave or particle? Light has. Wavelength Frequency Velocity

So how will this help us with camera exposures? Keep this law in mind as we move forward.

Histograms& Light Meters HOW THEY WORK TOGETHER

PRIMARY LIGHTING PATTERNS OF CLASSIC PORTRAITURE

THE PHOTOGRAPHER S GUIDE TO DEPTH OF FIELD

Rec. ITU-R F RECOMMENDATION ITU-R F *

High Dynamic Range Photography

CAMERA BASICS. Stops of light

Zone. ystem. Handbook. Part 2 The Zone System in Practice. by Jeff Curto

Color Temperature Color temperature is distinctly different from color and also it is different from the warm/cold contrast described earlier.

!"#$%&'!( The exposure is achieved by the proper combination of light intensity (aperture) and duration of light (shutter speed) entering the camera.!

A Beginner s Guide To Exposure

Rules for Perfect Lighting: Understanding the Inverse-Square Law By John Nolan of photography.tutsplus.com

ISO INTERNATIONAL STANDARD

QUANTUM CALCU-FLASH OPERATING INSTRUCTIONS

METERING FOR A BETTER PHOTOGRAPH

Understanding Your Camera 2: UUU200

High Speed Sync: A Flash Technique To Add a Pro Touch to Your Photographs

Panoramic imaging. Ixyzϕθλt. 45 degrees FOV (normal view)

How This Works: Aperture size is counted in f- stops. i.e. those little numbers engraved on the lens barrel like:

Histograms and Tone Curves

Lecture 18: Light field cameras. (plenoptic cameras) Visual Computing Systems CMU , Fall 2013

Speed and Image Brightness uniformity of telecentric lenses

EASTMAN EXR 200T Film / 5293, 7293

Portrait Lighting set-ups

ABB i-bus EIB Light controller LR/S and light sensor LF/U 1.1

Photography PreTest Boyer Valley Mallory

KFM-1100 AUTO DIGI METER KFM-2100 FLASH METER KCM-3100 COLOR METER

ISO INTERNATIONAL STANDARD

Resolution test with line patterns

Digital camera modes explained: choose the best shooting mode for your subject

Love Your Camera (Introduction to D-SLR)

TENT APPLICATION GUIDE

EASTMAN EXR 200T Film 5287, 7287

ISO INTERNATIONAL STANDARD

PHIL MORGAN PHOTOGRAPHY

PHOTOGRAPHER S GUIDE TO THE PANASONIC LUMIX LX7

Advanced Photography. Topic 3 - Exposure: Flash Photography Tricks

BROADCAST ENGINEERING 5/05 WHITE PAPER TUTORIAL. HEADLINE: HDTV Lens Design: Management of Light Transmission

EASTMAN EXR 500T Film 5298

level 6 (24 SCQF credit points)

Chapter 18 Optical Elements

Study guide for Photography / Understanding the SLR Camera

High dynamic range imaging and tonemapping

PHOTOGRAPHING THE ELEMENTS

Topic 2 - A Closer Look At Exposure: ISO

On spatial resolution

A Study of Slanted-Edge MTF Stability and Repeatability

EBU - Tech 3335 : Methods of measuring the imaging performance of television cameras for the purposes of characterisation and setting

Photomatix Light 1.0 User Manual


EASTMAN EKTACHROME High Speed Film (Tungsten) 7250

Taking your own Head Shot. by Megan Dill

Nuclear Associates Precision Photometer

NOVEMBER 22, that's going to make the difference between photos you'll want to share and those you'll probably delete.

Photography Help Sheets

CHAPTER 7 - HISTOGRAMS

Defocus Control on the Nikon 105mm f/2d AF DC-

SHAW ACADEMY. Lesson 8 Course Notes. Diploma in Photography

How to Champion the art Of Flash Photography

Illustrated Lecture Series;

1 MPTVI DATA SHEET XXXXXXXXXXX

Image Formation. Dr. Gerhard Roth. COMP 4102A Winter 2015 Version 3

An Inherently Calibrated Exposure Control Method for Digital Cameras

Introduction to 2-D Copy Work

Open Lab Hours: Will be posted on the studio door after the first week of classes. Taylor 008, 022

QUANTUM PHOTO-METER LX OPERATING INSTRUCTIONS. ... Three decimal points only displayed Overrange reading. Adjust Range. ( X 1000will light up)

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY NATIONAL CERTIFICATE MODULE: UNIT SPECIFICATION GENERAL INFORMATION. -Module Number Session

Photography and graphic technology Extended colour encodings for digital image storage, manipulation and interchange. Part 4:

Pixel Response Effects on CCD Camera Gain Calibration

ISO 3664 INTERNATIONAL STANDARD. Graphic technology and photography Viewing conditions

Pinhole Photography. Martin Henson Photography

APPLICATIONS FOR TELECENTRIC LIGHTING

Physics 2306 Fall 1999 Final December 15, 1999

Digital Photography: Fundamentals of Light, Color, & Exposure Part II Michael J. Glagola - December 9, 2006

AF Area Mode. Face Priority

FILM IDENTIFICATION GUIDE

Objective: to give you some understanding of why you might push more than just the big shiny silver button...

Polarizers, how they work, when to use them, how to use them...

Great (Focal) Lengths Assignment #2. Due 5:30PM on Monday, October 19, 2009.

Blown Highlights: "How Much Is Acceptable?"

WCBPA-Washington Classroom-Based Performance Assessment A Component of the Washington State Assessment System The Arts

KODAK VISION Expression 500T Color Negative Film / 5284, 7284

Autofocus Problems The Camera Lens

Reference Free Image Quality Evaluation

Transcription:

The Hemispherical Receptor Incident Light Exposure Meter Douglas A. Kerr Issue 2 August 5, 2014 ABSTRACT Incident light exposure metering is a useful technique for planning photographic exposure in many situations. An important genre of incident light exposure meter uses a hemispherical receptor. While there are various facile explanations of what this formulation does and why that is beneficial, the underlying technical concepts are elusive. In this article I give a concise overview of the basic operation and premises of this type of meter. Some basic background in the concept of incident-light exposure metering is provided. 1. Preface The material in this article is for the most part drawn from the companion article by the same author, "The Secret Life of Photographic Exposure Metering", probably available from the same place you got this. It places this topic in a broader context of exposure metering and gives much further technical detail. Readers interested in such are commended to that article. 2. Exposure planning 2.1 Our objective Before we can look into ways to plan photographic exposure, we must be able to articulate what we want in the result. One widely-cited objective (on which we will focus here for a while) can be described thus (in a digital image context): Objective B: In the final image, the implied relative luminance of each scene element should correspond to the reflectance of that element. 1 2 1 The significance of the "B" is to fit in with other writings in which I describe another objective as Objective "A". 2 This is closely related to the underlying premise of the famous "zone system" of planning photographic exposure. Copyright 2014 Douglas A. Kerr. May be reproduced and/or distributed but only intact, including this notice. Brief excerpts may be reproduced with credit.

The Hemispherical Receptor Incident Light Exposure Meter Page 2 A popular way to describe one of the implications of this objective is that, if the objective is attained: For a shot of a white cat on a snowdrift, the image will look like a white cat on a snowdrift. For a shot of a gray cat on an ash heap, the image will look like a gray cat on an ash heap. For a shot of a black cat on a coal pile, the image will look like a black cat on a coal pile. 2.2 A fly in the ointment A complication is that we cannot possibly attain that objective if the illumination is not essentially uniform from all directions. Often is it not (and in fact in just a little while we will look into a reason we may intentionally make it substantially non-uniform). But for now we will press on as if that objective can be attained. 2.3 Exposure planning to attain that objective If in fact the illumination on our subject is uniform from all directions (meaning, to be technically precise, that the illumination would give the same illuminance on a subject surface of any orientation), then (regardless of the fact that various elements of the subject surface face in different directions) that objective can be attained. We can actually do that by using a photographic exposure (that is, a combination of shutter speed and aperture) that is based in a fixed way on that consistent illuminance (and of course the sensitivity of the film or digital sensor). We can handily determine that illuminance with a "basic" incident light exposure meter, one that actually measures the illuminance on the plane of its receptor. 3 And, since at this point we assume a directionally-uniform illumination, we can orient the meter any way we like. 3. Key-fill lighting 3.1 Description An important lighting technique, often used in cinematography and also in portrait and "fashion" still photography, uses two light sources. One, the "key light", is the primary source. It is placed to illuminate the subject from some direction chosen by the photographer to get the 3 Such a meter can be described as having a cosine response. Its response to a light beam of a certain potency, arriving at a certain angle, is proportional to the cosine of that angle.

The Hemispherical Receptor Incident Light Exposure Meter Page 3 desired "sculpting" of the subject (by way of shadowing by the subject's features). It is commonly directed toward the subject from an angle of 30-60 from the camera axis (on one side or the other). The second source, the "fill light", is usually of less "potency" (to use an intentionally unscientific term), and is typically directed at the subject from the camera position. Its job is basically to "dilute" the sculpting so the desired artistic effect is attained. We often describe the particular arrangement use in terms of the ratio between the "potency" of the two light sources (sometimes described as the "contrast ratio", a term that is not particularly apt). This is actually in terms of the ratio of luminous flux density of the two beams as they arrive at the battle zone. But is it more often described (imprecisely) as the ratio of the illuminance of the two beams, actually meaning the illuminance they would cause on a surface directly facing the respective source. Commonly-used ratios (key:fill) range from 1:1 to 8:1. This is of course a non-uniform illumination situation. 3.2 Exposure planning in this situation Here we have intentionally provided a substantially non-uniform illumination, and so of course we cannot hope to attain Objective B. So we must adopt some other criterion for the result we hope to attain by our choice of photographic exposure. In the absence of any objective criterion for the result, we cannot hope to address the question, "what kind of incident light exposure metering technique will recommend the 'proper' photographic exposure in a key-fill lighting situation". Many empirical techniques have been suggested, such as to perhaps use an "illuminance-responsive" incident light meter to take two readings, one with the meter receptor facing the key light source and one with it facing the camera (and thus perhaps the fill light source) and somehow make an exposure determination from those. This was not considered handsome by professional cinematographers and photographers, both because it was clumsy and because it did not necessarily give the "most appropriate" photographic exposure recommendation (meaning that this did not consistently lead to a "desirable" overall exposure result, whatever that would mean).

The Hemispherical Receptor Incident Light Exposure Meter Page 4 4. The hemispherical receptor meter 4.1 Introduction In the late 1930's, noted cinematographer Donald W. (Don) Norwood, well aware of the problem of conveniently determining the optimum photographic exposure in a key-fill lighting situation, introduced a new type of incident light exposure meter. In its first form, this had a photoreceptor that had the shape of a hemisphere. In the intended use of such a meter, the hemispherical "dome" is always "pointed at" the camera, regardless of the lighting arrangement, and a single reading taken. Later, in order to reduce the cost of manufacture, Norwood developed an alternative implementation, using a translucent hemispherical shell at the base of which was a classical flat photoreceptor. Soon, this type of meter became de rigeur for professional cinematographers and photographers, and that product trail continues to this day, as seen most prominently in many exposure meters made by Sekonic, eventual successor to the rights to the Norwood patent. In figure 1, we see a Norwood Director, Model B exposure meter (made by American Bolex, ca. 1948), in this particular livery probably the most beautiful exposure meter of all time. Figure 1. Norwood Director exposure meter, Model B 4.2 How do it know? Image James Ollinger We can readily predict the angular response of a hemispherical receptor meter. With that in hand, it is tempting to try and develop a mathematical model that will show why the reading of such a meter

The Hemispherical Receptor Incident Light Exposure Meter Page 5 would be a good determinant of the "optimum" photographic exposure over a range of subject configurations and lighting situations. But such a quest is doomed, at best, in part by the fact that there is no clear criterion as to what exposure result is "best". (Recall that we cannot just say "attain Objective B", because that cannot possibly be attained in the general case of non-uniform illumination.) Several facile explanations of how this meter do that voodoo that it do so well begin with the notion that "[the meter is] substantially uniformly responsive to light incident upon the photographic subject from practically all directions which would result in the reflection of light to the camera or other photographic register." 4 But although that sounds nice, and is correct, it doesn't really explain why the resulting meter reading is a good determinant of the most appropriate photographic exposure in non-uniform illumination situations. A later explanation by Don Norwood tells us that the hemispherical receptor is a proxy for the visible-to-the camera portion of a human head (a subject that is certainly a preoccupation of fussy lighting planning). Some analysis leads us to realize that the reading of a hemispherical receptor meter approximates for us the average illuminance over the camera-visible surface of such a subject. That at first sounds like a telling parameter from which to determine the proper photographic exposure. But as we try to build that into some model as to why that parameter should be the determinant of the most appropriate photographic exposure, it doesn't come together. For one thing, if we use a hypothetical uniform-reflectance subject to help us follow the "photometric trail", we find that the average illuminance on the subject is not a good predictor of the average luminance seen by the camera. And of course, as before, another stumbling block is that we cannot describe, for a case of non-uniform illumination, a good criterion of the "appropriateness" of exposure result. 4.3 Aha! In 1950 (well, it was about time!), Norwood published a paper ("Light Measurement for Exposure Control", J SMPTE 1950, 54:585-602) that presented a credible, albeit empirical, rationale for the working of the hemispherical receptor meter. 4 Cited in fact from Norwood's original patent on the hemispherical receptor meter.

The Hemispherical Receptor Incident Light Exposure Meter Page 6 In it, he described the results of tests in which human observers compared a shot of a certain subject taken with a "head-on" key light with a shot of the same subject taken with a key light (of consistent potency) at a certain angle to the side, for various angles. All shots included the use of fill light (at a ratio of 8:1, key to fill). The exposure used for the "head-on" shot was based on incident light measurement of the actual key+fill illuminance on the camera-facing plane, using the generally-accepted incident light metering equation. For each key light angle, a number of shots were taken with various increments of photographic exposure greater than that used for the head-on shot. For each series of shots, the observers were asked which side-lit shot "matched in appearance" the head-on shot. Whatever that meant. Clearly they would not "look the same" since the "sculpting" would be quite different. We must assume that what Norwood meant was that the shots "matched in the impression of overall exposure result", or some such notion. Statistical analysis of the test data led Norwood to the conclusion that, over the range of subjects used, the photographic exposure required for the side-key shot to get visual parity with the head-on key shot was, on the average, greater than the photographic exposure for the head-on key shot by the amount shown in column 2 of this table: 1. Key light angle (degrees) 2. Needed additional exposure (stops) 3. Implied relative effective illumination 4. Relative reading of hemispherical receptor meter 5. Relative reading of cosine pattern meter 0 0 1.00 1.000 1.333 45 0.42 * 0.75 0.870 0.986 90 1.00 0.50 0.566 0.148 135 2.00 0.25 0.146 0.148 * Shown in the paper as "0.50 "; the value in this table is back-formed from the exact value of implied relative effective illumination given in the paper. Column 3 shows the implication of the needed additional photographic exposure "the other way up", as a declining "relative effective value" of the illumination offered by the combination of the two light sources, the response of 1.00 at 0 being by definition. 5 5 The cynical reader may marvel that, in the face of such a highly subjective observation, the statistical result led to such tidy values of the relative effective illuminance at these angles, forming a perfectly linear progression with angle.

The Hemispherical Receptor Incident Light Exposure Meter Page 7 Therefore, if we wished to have a meter that would automatically call for, in its exposure recommendation, the additional exposure needed for side key lighting, then its relative reading, from both key and fill light, should ideally equal the value in the column 3. 6 The theoretical relative reading of a hemispherical receptor meter (responding to both key and fill light) is shown in column 4. We see that this is in modest agreement with the "requirement" in column 3. Thus we can expect a hemispherical receptor meter to give us a generally-good exposure recommendation for key-fill technique over a range of key light location angles. To give a small snipe, I note that in Norwood's paper he says: The sensitivity pattern of the meter should ideally match column 3. (In fact, it is the meter "reading" its response to the combination of fill and key light that should match column 3.) The theoretical sensitivity pattern of a hemispherical receptor meter would exactly follow the values in column 3. (In fact, as we will see shortly, the theoretical sensitivity pattern is not the "linear decline with angle" implied by that statement.) These discrepancies are small, numerically, and do not disrupt the point being made, which in fact does not depend on any precise theoretical concept. In column 4, to "close the circle", we show the expected relative reading of a cosine-pattern (true illuminance) meter, with its receptor facing the camera and fill light. Here, I have assumed that, as is industry practice (and implied by the ISO standard), the 0 sensitivity of the cosine meter is 4/3 the 0 sensitivity of the hemisphericalreceptor meter. 4.4 Other lighting situations Norwood's 1950 paper presented a persuasive and easily-followed rationale for the well-known good performance of the hemispherical receptor meter in the very important key-fill lighting situation. But what about other non-uniform lighting situations? Will such a meter provide consistently "good" photographic exposure indications there? And in fact what criterion would we use to judge "success" there? And can we formulate some model that will show why that success is attained? I leave the judgment of the practical success of such meters in the general case to photographers that regularly use them. 6 Note that this is not the desirable value of the sensitivity of the meter at those angles; both key and fill light are involved here each at their own angle.

The Hemispherical Receptor Incident Light Exposure Meter Page 8 As to a theoretical model that shows how that comes about, given the lack of any accepted objective criterion of "success", and many other impediments, the quest for such a model would be a fool's errand. 5. The sensitivity pattern of a hemispherical receptor meter 5.1 Introduction I had earlier noted that for an exposure meter to respond to the illuminance of the incident illumination (as defined upon a plane of some particular orientation), we would need a meter with a "cosine" sensitivity pattern. In figure 2, we see a plot of such a pattern, in both polar coordinate and rectangular coordinate forms. Figure 2. Cosine sensitivity pattern If we derive the theoretical sensitivity pattern of a hemispherical receptor meter, we find that in polar coordinate presentation it exactly follows a curve known as a cardioid. 7 (A proof of this is given in the companion article.) In figure 3 we see a polar plot and a rectangular plot of a cardioid sensitivity pattern. Figure 3. Cardioid sensitivity pattern 7 The name, from the Latin, means "having the form of a heart". The allusion here is to the kind of "heart" we see on greeting cards.

The Hemispherical Receptor Incident Light Exposure Meter Page 9 6. CONCLUSION The hemispherical receptor concept of incident light metering, introduced by Norwood, has been shown to be a valuable tool in cinematographic and photographic exposure determination. We should not look to any objective theoretical models to explain that success. 7. ACKNOWLEDGMENT Special thanks to Carla Kerr for her careful and insightful copy editing of this manuscript at various points in its evolution. Any errors in its present form are solely my responsibility. #