E6500 Power Quality Analyzer

Similar documents
E6000 E6000. Handheld Power Quality Analyzer. Features. Functions

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Network Analyzer for Low-, Medium- and High-Voltage Networks

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

DM-5 Power Quality Analyzer

Power Quality Analyzer Topas 2000

Choosing your power quality analyzer

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Network Analyzer for Low-, Medium- and High-Voltage Networks

3196 POWER QUALITY ANALYZER. Solve All Your Power Quality Problems ISO14001 JQA-E Power Measuring Instruments

Record and Analyze Power Supply Problems Simultaneously with a Single Unit The New World Standard for Power Quality Analysis

A Power Quality Interface for Low and Medium Voltage Smart Grids

Network Analyzer for Low-, Medium- and High-Voltage Networks

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Fluke 1750 Three-Phase Power Recorder

Side view View from below Rear view

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

PQube 3 Specifications

Power Quality Analysers

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

National Standard of The People s Republic of China

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

6135A/PMUCAL Phasor Measurement Unit Calibration System

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Power Quality Analyzer / High Frequency Recorder

SAMSUNG ELECTRO-MECHANICS CO., LTD

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

RS Pro ENGLISH. Datasheet

Power quality report. A Manufacturing Plant

PQ Monitoring Standards

Introduction DIN rail mounted electricity meters

An Introduction to Power Quality

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Overcurrent Protection / 7SJ45

METRAClip87 and 88 Clamp Multimeters

PQA823 PQA824 Rel /09/18

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

MID energy meter B21 Single-phase energy meter, 65 A

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

Investigate All Your Power Quality Problems

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

MPQ1000. Handheld Power Quality Analyzer. Automatic CT recognition. Automatic connection verification. On-board data analysis

SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks

SAMSUNG ELECTRO-MECHANICS CO., LTD

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

OLU131P701N1A PSOV131701A(N) PSOV131701B(N) PSOV131701D(N) (for SAMSUNG) PSOV131701E(N) (for SAMSUNG) SOLUM CO., LTD

MEASURING INSTRUMENTS AND TESTERS

Power Analysis Summary

UMG 103-CBM. Universal measurement device for DIN rails

Investigate All Your Power Quality Problems

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

3 Phase Power Quality Analy er

RS Pro ENGLISH. Datasheet

With any other power quality analyzer you re just wasting energy.

PQube 3 Firmware 3.5.0

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Power Quality Analyser TOPAS 1000

Fluke 3540 FC Three-Phase Power Monitor

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Three Phase Power Calibrator and Tester of Power Engineering Devices

Technical Specifications for Portable 3-Ø Power Analyzer

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

DM-III Multitest & DM-III Multitest F Power Quality Recorders

Interruptions: Voltage event where the effective value is below 10 % (or 1 % according to criteria used) of the declared nominal voltage.

Low Frequency Measuring System

Flickerless / Dim Power supply

Flickerless / Dim Power supply

Power Quality Report. A Manufacturing Plant

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Fluke 3540 FC Three-Phase Power Monitor

Complimentary Reference Material

SDM3045X Digital Multimeter. DataSheet

PQM3000R Class A network analyzer according to EN for power quality monitoring

PQA823 PQA824 Rel /01/2007

SDM3045X Digital Multimeter. DataSheet

MULTICHANNEL ACQUISITION SYSTEM

AMIK 200 / 201 Technical Data Sheet

Handy and Easy to Use Power Management Support

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Data Sheet. RISH Master Record %THD

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Doc. EA Model Number:

PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 MODEL 61509/61508/61507/61609/61608/61607

High precision measurement system for current and voltage IHC-A/B-RM01/03

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Transcription:

E6500 Power Quality Analyzer E6500 power quality analyzer can record and analyze all power quality parameters such as harmonics, voltage, current, frequency, fluctuation, flicker, power and three-phase unbalance on site, as well as possess transient electrical energy monitoring, waveform recording analysis, energy-efficiency loss assessment, inverter measurement and other advanced measurement functions. The analysis software running on PC performs the secondary analysis of the measurement result, which provides accurate data basis for power quality management. Core technology specifications Flicker accuracy: ± 5% Voltage accuracy: 0.1% Frequency: 50Hz/60Hz cycle: 10/12 cycles Frequency bandwidth: 42.5-69Hz Voltage unbalance: ± 0.2% Current unbalance: ± 0.5% Maximum sampling frequency: 200kHz Current accuracy: 0.1% + CT accuracy Power factor accuracy: 0.5% + CT accuracy Voltage test range: 0-1000V. 6000V transient voltage Data storage: 8G Working hours: 5h IP grade: IP53 Supports manual/automatic waveform recording Waveform recording time: 10s-10min Waveform recording cycle: 10/12 cycles Minimum recording interval: 0.2s USB transmission speed: 17M/S Harmonics measurement:1-50th/50hz- 2500Hz Waveform recording sampling point: 128/256/512 points/cycle Security level: 600 V CAT IV/1000 V CAT III Interface language setting (Chinese and English) Supports multi-brand transformer Inverter measurement: single-phase/ three-phase Energy loss analysis: monetary statistics Professional PC analysis freeware Transient monitoring: captures 50µs shortest waveform pulse Complies with IEC61000-4-7 harmonics measurement standard Complies with IEEE 1459, DIN 40110 algorithm Complies with IEC61000-4-15 flicker measurement standard Interharmonics measurement: 50th/25Hz-2475Hz Higher frequency harmonics: 35th/2100Hz-8900Hz ZHIYUAN Electronics Making a world of difference

Product Selection Product Type E6500 E6100 E6000 PQ3000 Waveform recording analysis Appearance Event record Harmonics analysis Transient monitoring Energy-efficiency loss items Inverter measurement Flicker Other functions Channel Power/Energy Voltage/Current Unbalance Frequency PC software analysis Instant printing Remote control Networking management Voltage/Current 4/4 4/4 4/4 16/16 range Voltage 1-1000V 6000V transient voltage 1-1000V 6000V transient voltage 1-1000V 6000V transient voltage 1-1000V 6000V transient voltage Current DC, AC AC AC AC Frequency Frequency/ Cycle 50Hz 60Hz/10 12 cycles 50Hz/10 cycles 50Hz/10 cycles 50Hz/10 cycles Battery Battery capacity/ Battery life 5000mAh/ 5h 4500mAh/ 4h 4500mAh/ 4h 90Wh/2h Storage Type/ Capacity TF(built-in)/8G SD external /8G TF(built-in)/8G Solid State Disk (SSD) /32G Interface Number/Type One USB One USB One Ethernet interface One serial port One USB Two USB Screen Size/Resolution 5.6 inch/640*480 8 inch/800*600 5.6 inch /640*480 9 inch/800*480 Machine Dimension / Weight 263x168x65mm/ about 2kg 338x222x73mm/ about 2.5kg 263x168x65mm/ about 2kg 448x197x230mm/ about 6kg Advanced Function Waveform recording analysis Parameter statistics Supports 1-10min waveform recording function. Users can record the original waveforms with customized sampling points. The professional software running on PC performs the secondary waveform analysis so as to analyze the causes of power grid faults more effectively. Re c o r d s a n d a n a l y z e s p o w e r q u a l i t y p a r a m e t e r s comprehensively. The minimum recording inter val is 0.2s. The analysis software running on PC performs the secondary analysis of the recorded data and generates customized or national standard report.

Transient monitoring Captures instantaneous 50µs shortest waveform pulse at 200kHz high-speed fixed frequency sampling rate as well as fast-changing waveform data. Meanwhile, the original waveform recording function of transient event is supported. Energy-efficiency loss assessment Supports power decomposition, detailed statistics of energy loss caused by various parameters, and pollution assessment, displaying the economic losses caused by energy loss in monetary terms visually. Inverter measurement Supports energy parameters analysis for single-phase/ three-phase inverter, analyzes and records the parameters such as DC input, AC output and conversation efficiency of inverter. Oscilloscope Displays 4-channel voltage/current waveforms, supports horizontal/vertical zooming and displays waveform distortion visually to present how higher frequency harmonics affect signals. ZHIYUAN Electronics Making a world of difference

Features Multi-regional standard High accuracy, broad band, wide range E6500 supports a power frequency of 50Hz/60Hz and provides Chinese and English language setting. Users can set the colors of phase sequence for different countries and set the computation methods to satisfy different users requirements. The measurement accuracy complies with the IEC 61000-430 Class A standard, IEC6100-4-7 harmonics measurement method and IEC61000-4-15 flicker measurement principle. The maximum measurable transient voltage is 6000V, and the maximum frequency of higher frequency harmonics can reach 9kHz. Transient overvoltage Line voltage 1P2W 1P3W,3P3W) Phase voltage 1P2W 1P3W,3P3W) Voltage frequency bandwidth 50Hz 400V 800V 6000Vpe Higher frequency harmonics measurement Harmonics measurement 2.5kHz 10kHz Setup Wizard Wiring verification It helps users set parameters to implement basic measurement settings, and solves the problems of setting parameters faced by new users with a simple and convenient visual guide. The innovative function of wiring verification helps users complete wiring connection correctly to prevent invalid record caused by wiring errors. Compatibility design IP53 protection grade I t i s c o m pa t i b l e w i t h m u l t i - b r a n d c u r re n t transformer. It has 1.5m impact-proof protection capability, and the protection grade is IP53.

PQViewer Power Quality Data Analysis Software PQViewer is the data analysis software equipped with the power quality analyzer. It is able to read the power quality data files collected and recorded by analyzer, provide data statistics and analysis function, export measurement data as well as reports in accordance with international standards, and help users identify the power quality problems quickly and correctly. Data analysis function Statistic data analysis. The statistical results of voltage, current, power, frequency, harmonics and other data are displayed in the trend graph. The state variation of all energy data can be observed at a glance. Harmonics analysis. The statistical results of harmonic data are displayed in the histogram and trend graph. The information from detailed data to macroscopical results of harmonics can be understood. Event data analysis (transient event and steady alarm event). The time, type and details of events are reported, and the power quality state at the moment of event occurrence can be analyzed by singlechannel analysis and multi-channel contrast. The reports in accordance with international standards are generated through simple operations. Data export and report Exports the content of reports. The Excel format reports, trends, harmonic frequency spectrum histograms and ITIC curves can be output quickly. They are widely used in the secondary analysis of measurement data for higher efficiency. In addition, the reports in Word format are provided to realize the viewing of tabular data and images simultaneously with rich content and less time. Exports raw data. The raw data of records are exported in the csv files to facilitate the secondary data analysis and obtain accurate results. Simple operation. The export is completed through two-step operation. Report in Excel Format Report in Word Format ZHIYUAN Electronics Making a world of difference

Inspection Report E6500 power quality analyzer developed by ZHIYUAN Electronics has passed the tests of national authority, won a number of authoritative certificates, including the Ketop type test certificate, the State Grid EPRI registration record certificate and the Guangdong EPRI test reports. The product has been recognized by many national standard institutions and market since its launch, which effectively promotes the technology development and marketing of our company. Accessories Information Name Quantity Picture E6500 host machine 1 set Power adapter 1 set Standard Accessories Voltage measuring line, alligator clip, voltage conversion terminal USB data cable 5 sets 1 piece Product user manual 1 set Product handbag 1 piece Product Type ZY-CTS5 ZY-CTS200 ZY-CTS500 ZY-CTS3000F ZY-CTS6000 Appearance Current Transformer (optional) Amplitude Accuracy (10~100%fs) ±0.3%rdg ±0.3% rdg ±0.3%rdg ±1%rdg ±1%rdg Nominal Input Current (AC) 5A 200A 20A 500A 3000A 6000A 600A 60A Output Voltage (AC) 10mV/A 10mv/A 1mv/A 1mV/A 85mV/kA 0.5mV/A 5mV/A 50mV/A

Product Specifications General Parameters Parameters Parameter Type Description Machine Environmen Storage Power Supply Battery Display Safety Dimension (mm) 263 168 65 Weight Working Environment Storage Environment About 2kg 0 ~ +45, less than 90rh% humidity -20 ~ +50, less than 95rh% humidity (noncondensing) Type TF card (built-in) SD card (external) Capacity 8GB 8G (maximum 128G supported) Adapter Input 110V-240V,50Hz Adapter Output 15V,3A Type Chargeable Li-Polymer battery, 5000mAh Battery Working Hour 5h Battery Charging Time Minimum 5h (at 25 ambient temperature) Power Saving Adjustable LCD backlight brightness and standby time Dimension Color 112.8 84.6mm 260k colors Resolution 640 480 Brightness Maximum 350 cd/m²(typ.) brightness, adjustable brightness Contrast Viewing Angle Compliant Standard Banana Input Terminal Between Voltage Input Terminals Interference Between Voltage and Current Input Terminals Common Mode CMRR Rejection Method Standard Environmental Reliability EMC 500:1(Typ) 70/70/50/70(Typ.) (CR 10) (left/right/up/down) GB 4793.1-2007/IEC 61010-1: 2001, Safety Requirements for Electrical Equipment for, Control and Laboratory Use - Part 1: General Requirements. Security Level: CAT III 1000V/ CAT IV 600V. CATIII 1000V/CATIV 600V -60dB at nominal frequency -95dB at nominal frequency >60dB IEC 61000-4-30 Performance IEC 61000-4-30 Class A Flicker IEC 61000-4-15 Harmonics IEC 61000-4-7 Power Decomposition IEEE 1459 Standard Standard GB/T 2423.1-2008: Cold GB/T 2423.2-2008: Dry heat GB/T 2423.4-2008: Damp heat, cyclic (12h+12h cycle) GB/T 2423.5-1995: Shock GB/T 2423.10-2008: Vibration GB/T 2423.22-2002: Change of temperature Class 4: GB/T 17626.2-2006: Electrostatic discharge immunity test Parameters Parameter Type Description EMC Standard Class 3: GB/T 17626.3-2006 Radiated Radio- Frequency Electromagnetic Field Immunity Class 3: GB/T 17626.4-2008 Electrical Fast Transient/ Burst Immunity Class 3: GB/T 17626.5-2008 Surge(Impact) Immunity Class 3: GB/T 17626.8-2006 Nominal Frequency Magnetic Field Immunity Class 3: GB/T 17626.9-1998 Pulse Magnetic Field Immunity Class 3: GB/T 17626.12-1998 Oscillatory Waves Immunity Parameters Function Logger Inverter Transient Monitor Parameter Type Oscilloscope Voltage, current, frequency Power and energy Voltage harmonics Current harmonics Harmonic power Description Real-time waveforms of A, B, C, N phase voltage and current Frequency, voltage RMS, half-cycle voltage RMS, voltage positive peak value, voltage negative peak value, voltage form factor, current RMS, half-cycle current RMS, current positive peak value, current negative peak value, current form factor Active power, reactive power, apparent power, power factor, displacement power factor, active energy, reactive energy, apparent energy THD, DC, 1-50th harmonics, 0-49th interharmonics, 1-35th higher frequency harmonics THD, DC, KF, 1-50th harmonics, 0-49th interharmonics, 1-35th higher frequency harmonics THD, DC, 1-50th harmonic power Flicker PST (short term flicker), PLT(long term flicker) Positive-sequence voltage, positive-sequence current, negative-sequence voltage, negativesequence current, zero-sequence voltage, zero- Unbalance sequence current, unbalance Active, reactive and apparent power decomposition, Energy loss line loss power, line loss cost, pollution evaluation Demand Demand Voltage swell, voltage dip, voltage interruption, inrush current, PST limit, PLT limit, voltage upper deviation, voltage lower deviation, over frequency, Event record under frequency, steady-state voltage fluctuation, voltage unbalance limit, voltage THD limit, 1~50th harmonic voltage limit, 2~50th harmonic current limit DC voltage, DC current, DC power, ripple voltage, DC ripple voltage percent Frequency, voltage RMS, current RMS, total apparent AC power, total active power, total power factor, fundamental power, fundamental power factor Efficiency Conversion efficiency Voltage RMS, half-cycle voltage RMS, voltage Voltage positive peak value, voltage negative peak value Current RMS, half-cycle current RMS, current positive Current peak value, current negative peak value Frequency Frequency Event record Voltage swell, voltage dip, voltage interruption Voltage RMS, 1~50th harmonic voltage, PLT, voltage Monitor dip, voltage swell, voltage interruption, steady-state voltage fluctuation, voltage unbalance Official Wechat Account ZHIYUAN Electricity Guangzhou ZHIYUAN Electronics Co.,Ltd. Address: Floor 2, Building No.7, Huangzhou Industrial Estate, Chebei Road, Tianhe District, Guangzhou, China TMALL Store: ZLG official Online Store URL: http://zlgwj.tmall.com VOL.001