MICRO 2 Weather Station. User Manual

Similar documents
Copyright 2006, Dynamax Inc. All Rights Reserved

Copyright 2011, Dynamax Inc. All Rights Reserved

Gared Pro-S Portable Backstop

SRS-200 Solar Radiation Sensor Installation and Setup Instructions. SRS-200 with optional Leveling Plate and Mounting Bracket. Revision 2.0.

Football Goal Posts MODEL SERIES: FGP400 and FGP600 series

S OLAR RADIATION S HIELD MANUAL

Rain Gauge Smart Sensor (Part # S-RGA-M002, S-RGB-M002)

BUMP GATE FITTING INSTRUCTIONS.

MPA-9000 Universal Ceiling Projector Mount Kit

Installation Instructions Hustler 6-BTV Trap Vertical

00108/00110 INSTRUCTION MANUAL

SawStop. T-GlideTM. Fence System- Professional Series II OWNER S MANUAL

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

Ambient Weather EZ Stable Mounting Kit with Mast for AcuRite Weather Stations User Manual

Spiral Slide

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

ALUMINUM POLE VAULT STANDARDS SPECIFICATIONS

MAKO TM CASH DISPENSER

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER #

Nancy s Knit Knacks LLC 4 Yard Option Upgrade Kit Assembly Instructions and User Manual

M2 Antenna Systems, Inc. Model No: 2M4

ABM International, Inc. Navigator Assembly Manual

BISON GOOSENECK FOOTBALL 1 PAIR OF GOAL POSTS

Warnings. Description. Prior to Installation Tools Needed

Assembly Instructions for Model: MF110

Hollywood Swing Away 2 and 4 Bike Racks Assembly and Installation Guide

Installation Instructions Hustler 6-BTV Trap Vertical

UPM 6X Custom. UPM 6X CUSTOM Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

ABM International, Inc.

Codonics SLS 500i Shelf Installation

Ambient Weather EZ Weather Station Tripod and Mast Assembly for AcuRite Weather Stations User Manual

Installation Instruction

Mounting a BalanceBox 400 to a brick wall

INSTALLATION INSTRUCTIONS

Video Wall Installation Instructions 2W X 3H, 3W X 3H

WS-PRO2 Golf Course Weather Station. Installation, Operation, Maintenance, and Troubleshooting Manual

Type 100 and Type 120 SMC Antenna System 1.0 Meter and 1.2 Meter Reflector with Az/El Cap Mount

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

Kwik-Lock. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS

Z-Truck Up-and-Down Motion. Y-Truck Side-to-Side Motion. Head. Squaring Plate. Sliding Plate FIGURE 1: THE CARVEWRIGHT MACHINE

Paradigm. Connect100 Installation Guide

Tilting Flat Panel Wall Mount Installation Guide

User Instructions Multiline Otter Scoreboard Caddy Assembly

Elimination of Elevator Bounce

SwingSafe Swing-Away Mailbox Support Diagram

00108/00110 INSTRUCTION MANUAL

Gared Pro Portable Backstop

INSTALLATION INSTRUCTIONS FOR SMLS/SMSS Surface Mount Lock Shear & Surface Mount Strike Shear

TABLE OF CONTENTS REQUIRED TOOLS

The following instructions will guide you through the installation of your new vinyl railing stair kit.

Desk/Wall-Mount Rack

INSTRUCTION MANUAL V-42R. Dual Band Collinear Gain Vertical for MHz and GENERAL DESCRIPTION

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

BBULTRA Basketball Tower Installation

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

INDEX PAGE RELEASE SECTION NUMBER DATE

Install Instructions. NewAge Steel Welded Tall Locker

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

Large Wood Windmill Assembly Instructions

Instruction Manual for 98cm Elliptical Ka Antenna

MS2 Straight Key Kit Assembly Manual

The Heritage Pergola

SawStop. Contractor Fence Assembly OWNER S MANUAL. Model CNS-SFA

UPM 6X. UPM 6X Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL ORDER NO. V3R MODEL V3R. Collinear Gain Vertical for MHz

M2 Antenna Systems, Inc. Model No: 2M7

Sales & Service. JFK - Just For Kids. sasportonline.com. 135 Forestview Road 7879 Will Rogers Blvd.

7141 & NATIONAL POLE VAULT STANDARDS SPECIFICATIONS

**MOUNTING YOUR MONITOR

High End Residential In-Ground Basketball System Owners Manual

PACKING LIST MACO V-5000

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Tilting, Swiveling & Rotating Flat Panel Wall Mount

SINCE 1922 P UBLICATION N O

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

INSTALLATION INSTRUCTIONS

Stainless Steel Bench Stand

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

Model BiConiLog Antenna. User Manual

SQ2 User Instructions SQ2 Overview:

MERRY GO ROUND ITEM NO: 8030

Continuous Handrail Kit Installation Instructions

M-1330A, 40A, 50A Tower Packages

7902 Dado Jig. Owners Manual Please Read Carefully! Hardware List: 7902 Parts List:

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

Kossel Rev B Build Guide V1.0

ShorePort PWC Lift Instructions " x 138" Sandstone ShorePort " x 138" White ShorePort " x 138" Tan ShorePort

Pole Conversion System For safe and efficient conversion of non-lowering light poles.

Signature Choral Riser Side Rail

Transcription:

MICRO 2 Weather Station User Manual

Copyright 2011, Dynamax Inc All Rights Reserved Specifications are subject to change. Dynagage is a new product for experimental purposes under development. DYNAMAX Inc assumes no liability for customer assistance, infringements of patents or copyrights arising from the use of this product. US Patents covering the construction of various stem flow gauges are No 5,337,604 and 5,269,183. DYNAMAX does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, or other intellectual property right of DYNAMAX relating to this product, or process. There are no implied warranties of merchantability or of fitness for a particular purpose given with the sale of any goods. DYNAMAX Inc shall not be liable for consequential, incidental or special charges., Dynagage, Dynamet, Flow32, Flow32W and Dynamax are trademarks of Dynamax Inc IBM is a registered trademark of International Business Machines Windows, Windows 95, Window 98, Windows NT, Windows2000, Windows Millennium, Windows XP, Windows Vista, Windows 7, Windows 8, Microsoft Office, Microsoft Excel are trademarks of Microsoft Corporation. Updated: 5/24/2017 1

Programs and algorithms verified by Michael van Bavel, BSEE John Yunpeng Ji, BSEE Program and algorithms, Copyright, Dynamax, Inc., 2011 Portions of the manual are courtesy of Campbell Scientific, Inc and are subject to Copyright 1998, Campbell Scientific, Inc. Trademarks used are property of their respective owners. 2

3

Single Pole Installation: The sensor default height is 6 ft or 2m above the ground surface. If you wish to add height to 3m or more, an optional tripod or mast mounting system is required for stability in the field. The following parts are supplied as part of the field installation kit. 1 steel pipe, 4 long ¾ aluminum pipe, 3 long cross arm Nu-rails (qty 2) Lightning Rod with Clamp Grounding Rod with Clamp 10, 12AWG wire ground wire Cable ties In addition the user must supply the following materials: 2 metal pipe, 6 long, threaded on one end for 2 in pipe thread Concrete (quick set) mix to secure the vertical pipe, and fill a 4 ft hole (1-2 bags). 2-4 gals water as recommended by concrete mix Wooden stakes, and tape to position and hold pipe while setting concrete Tools listed in the previous sections Pipe for rain bucket mount (see separate instructions for more details) Select site for installing weather station. The site should be away from obstructions and sprinklers. A flat ground is recommended for installation, even though the unit can be installed in many different terrains with some professional help Prepare an area of 10 diameter for installing mounting pole with little disturbance to the ground surface or vegetation Dig a posthole of 6-8 in diameter and 4 ft deep with a shovel or with a posthole digger. Mix two bags of quick set concrete mix and pour into the hole. Insert the 2 pipe in the pit and fix the pole position vertically with wooden stakes and tape The 2 pipe should extend only two feet above the ground surface You may also tap the pole into the bottom of the hole with a hammer as long as the threads are protected. Then pile rocks or bricks around the pole to hold the position vertical. Check the vertical pole with a level to make sure it is vertical before leaving for the day. Wait for about 24 hours while the concrete sets. Apply pipe dope or Teflon tape to threads on the threaded pipes. To prevent cross threading, hand thread the bell reducer and then tighten with a pipe wrench. Then hand thread the 4 ft X1 pipe mast into the threaded reducer and then tighten with a pipe wrench Install Nu-rail (3/4 X 1 ) on the end of 4 X1 diameter pipe, both supplied with the weather station. Adjust the Nu Rail to 1 ft 5 in below the top of the mast, so the cross arm will point roughly east and west. Tighten the setscrews Insert cross arm in the horizontal bore of Nu-rail (3/4 ). Center the cross arm, and tighten using set screws See diagram on following page. 4

5

Install the second Nu-rail (3/4 X ¾) with the short ¾ vertical mounting pipe on one end of the cross arm Now install wind speed & direction set on vertical mounting pip you just installed Install Pyranometer leveling base (CM225) on the other end of the cross arm as shown in the picture using U-bolts and nuts supplied POST ALTERNATIVE: 4 FT 4 FT 2 Wooden post or metal pole in 4 ft deep concrete filled hole. Alternative mounting without a 2 diameter -mounting pole is possible for a permanent position. Dig a posthole and mount a base pole or post that is made from an 8 ft long pipe with at least 2 in inside diameter or a wooden post with 4 or greater size O.D. Then drill three holes in the lower ½ of the 1 pipe (supplied as the mast) along the same line in the center. With mounting bolts, you then attach the mast to the post or pipe, and align the assembly vertically. Then pour the concrete and fix the position until the concrete has set. If the post is wooden, a grounding wire should be run from the metal pipe to the copper grounding rod. 6

Install pyranometer sensor on the leveling plate and secure with bottom screw. Install pyranometer leveling plate on top of the mounting bracket, leave the inner screws loose for now. Install leveling assembly and bracket onto the cross arm. The u-bolts can be tightened after you level the plate roughly. Now adjust the Allen (hex) set screws to level the bubble in the leveling plate, then tighten the inner fixing screws with a screwdriver. Install lightning rod (if applicable) on the pole mast. Rotate the threads and make sure the reducer coupling is holding both 2 and 1 pipes firmly. Lightning Rod: Position the lightning rod 4 down from the top of the mast, attach lightning rod to the mast and make sure the lightning rod set screw is tight. 4 Grounding Rod: Slide the clamp down the ground rod before driving it in the ground. Drive Ground rod close to the mounting pole using a fence post driver or sledgehammer. In hard soils use water to prime the soil and hole to make driving the rod easier. Loosen bolt that attached clamp to the ground rod. Draw Ground wire (Green) from the Microclimate enclosure and insert it between the rod and the clamp. Tighten the clamp bolt. 7

Solar Panel Installation A 15 cable is attached to the solar panel and the other end of the cable must be connected to the pigtail hanging from the cable gland labeled Solar Panel. Mount solar panel to the mast, facing south (in northern hemisphere) Position solar panel mounting at the top of the 1 ¼ diameter section of the mast. Install U-bolt muffler clamp and nuts. Solar panel should be oriented to receive maximum insolation over the course of the year. Below table lists tilt angles at various latitudes. Once the tilt angle is determined, loosed two bolts that attach mounting bracket to the panel. Adjust the angle and finally tighten the bolts as shown below. (For MSX10, MSX20 Setup) (For MSX5 Setup) 8

Install Enclosure weather station enclosure contains data logger, and other storage or communication peripherals if any. Digimesh Network Node Module is assembled inside the enclosure with surge protector outside. Sensor cables, Power cables, Communication cables connected to the data logger or any peripherals routed out of the enclosure through one cable gland marked outside on the cable itself. So it is not necessary for an end-user to make any wiring inside the enclosure. All the connectors are accessible out of the box. Position enclosure on the north side of the mast or tower (northern hemisphere). Secure enclosure as shown in the figure using mounting brackets. Route the 12AWG wire from the Ground Lug on the enclosure to the tripod-grounding clamp. Tighten the screws. Grounding is critical not only for the accuracy of data/ reduce signal noise but also to protect equipment from any lightening surges. 9

Wind Sentry (03002) 03002 RM Young wind sentry can be mounted directly to the mast, or to the cross arm. Wind sensors must be located away from obstructions. A distance of at least ten times the height of the near by buildings/ obstructions is recommended. Mounted to the Mast: Slide the cross arm-mounting bracket on to the mast. Orient the cross arm so the vane end points north, and tighten the band clamp. Attach the cup assembly to the anemometer shaft using the allen wrench provided. Attach the wind vane to the shaft and secure using the allen wrench. Orient wind vane such that counter weight points south using the procedure mentioned below, tighten the setscrews. Mounted to the cross arm Position the top of the mounting post 5 above the ¾ NU-RAIL and tighten the setscrews. Slide cross arm-mounting bracket onto the mounting post. Orient the cross arm so that the vane end points north, and tighten the band clamp. Attach the cup assembly to the anemometer shaft using the allen wrench. Attach the wind vane to the shaft and secure using the allen wrench. Orient wind vane such that counter weight points south using the procedure mentioned below, tighten the setscrews. Connect sensor leads from the weather station to the anemometer and wind direction sensor. Apply a small amount of lithium grease to the threads of the connector to prevent problems due to corrosion. 10

Wind Direction sensor Orientation Using a magnetic compass determine the magnetic north, apply magnetic correction for the declination to determine the direction of True North at the installation site. Magnetic declination is the number of degrees between true north and Magnetic North. Magnetic declination for a specific location can be obtained from USFA map, Local airport or through the USFS website. A general map of the magnetic declination for the United States is shown below. Declination angles east of TRUE north are negative, and are subtracted from 0 (360 0 ). Declination angles west of true north are positive and are added to 0 (360 0 ) to get True north. For example, Declination for Logan, Utah is 16 o East. (From the map) True North = 360 16 = 344 o (as read on the compass) To orient the wind direction sensors one-person must hold, aim and adjust the sensor and the other person to observe the wind direction displayed by the data logger. Establish a reference point on the horizon for True North. Aim the nose cone/ counter weight at the True North. Read the output of wind direction sensor displayed in the agrisensors website. Loosen the band clamps set screws that secure the base of the sensor to the mast or cross arm. While holding the vane in position slowly rotate the sensor base until the data logger indicates 0 degrees. Tighten the band clamps or set screws and secure the sensor base in position and vane free to rotate. 11

Agrisensors START LOGGING default settings Temperature and RH Sensor (HPM60) Position the radiation shield on the side of the mast that face the prevailing wind, with the top of the black plastic mounting base against the bottom of the bell reducer. Secure the radiation shield. Mount the radiation shield to the mast using U-bolts and secure the bracket to the mast. Loosen the split plastic nut on the base of the shield. Insert the probe and tighten the nut. 12

Solar Radiation (SP110) SP110 solar radiation sensor is supplied with Leveling plate LEV and mounting fixture(cm225). The base includes a bubble lever, sensor holding screw and three adjustment screws for level setting. The LEV leveling plate is set on top of the mounting fixture (CM225) and the mounting fixture is attached to cross arm as shown below using u-bolt and nuts. Position the base of the sensor in the leveling plate and tighten the mounting screw from the bottom. Mount the leveling plate on the mounting plate stand, and loosely attach using the three inner screws through the top holes with about 4 turns each. Now, adjust the three Allen (hex socket) leveling screws such that the bubble is in the center showing the sensor and leveling plate are horizontal. Tighten the three inner set screws to fix the position. Remove the red protective cap when ready to use. The PYR-P sensor comes pre-wired to the data logger. Simply route the cable from data logger to the sensor and secure with tie straps. 13

Soil Moisture Sensor (SM150T) SM150T soil moisture sensor measures volumetric soil moisture content by the principle of dielectric constant of the medium changes with water content. The change in dielectric constant is measured in mv DC voltage. Weather station reads the DC voltage and converts to volumetric soil content in %. Soil moisture sensor SM150T can be wired to the weather station. Select the location for installing the SM150T sensor, usually close to the sprinkler fall area or under the drip nozzle. Push the sensor in to the soil until the rods are fully covered. Route wire to the station and secure it from any damage. Based on the type of soil in which measurements are made, identify the constants slope and offset parameters. Enter these values in CR200 program to calculate soil moisture for either organic or mineral soil using polynomial equation. Linear constants a0 a1 Mineral Soil 1.6 8.4 Organic Soil 1.3 7.7 Rain Gauge Select a location about 10 from the mast installation, install the rain gage on the provided shelf attached to a customer supplied pole. (as seen in image below) Mount the rain gauge to a customer supplied vertical pipe Alternatively the rain bucket can be set on a level ground away from the mast 14