SPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS

Similar documents
ROOF FLASHING FEATURES & BENEFITS PRODUCT DESCRIPTION

900 SERIES WALL PANELS

DW HORIZONTAL INSTALLATION

SECTION SHEET METAL FLASHING AND TRIM

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

OHearneAssociates.com

KS42 MF SERIES - HORIZONTAL INSTALLATION

Eagle clad double-hung window installation instructions

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

eco-shake INSTALLATION INSTRUCTION

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

SECTION SHEET METAL FLASHING AND TRIM

Heckmann Building Products Inc. DOVETAIL SLOT AND ANCHORS SPECIFICATION SECTION MASONRY ANCHORS AND ACCESSORIES PART 1 GENERAL

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

ATOMIC. ASM Panel Brochure ARCHITECTURAL SHEET METAL,

SHEET METAL FLASHING AND TRIM Christ on the Mountain

AIA Specification. Section Slate Shingles PART 1 GENERAL

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

TABLE OF CONTENTS A-1

Installation Guide: NC 25 System

Slate Shingle Specifications

Integrity Polygon and Round Top Installation and Finishing Instructions

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

Tools required by installer: Materials required by installer:

400 SERIES VERTICAL INSTALLATION

Shapes Siding. Perfection Shingles. Chalk Line

KS SERIES - VERTICAL INSTALLATION

Section 914. JOINT AND WATERPROOFING MATERIALS

installation guide Villa

UL Construction No. 254

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

Brava Old World Slate Installation Guide

Ekoroof LiteTile Dimensions

Installation Guide - Evolution Series Wood Siding

Door Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone:

DW VERTICAL INSTALLATION

4. Metal roof jacks at penetrations and attachments

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Standard Practice for Installation of Rigid Poly(Vinyl Chloride) (PVC) Siding and Soffit 1

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

INSTALLATION INSTRUCTIONS

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS

CFDTT-01. Control Joint Study (General)

GUIDELINE SPECIFICATIONS

Flashing Materials. Rough Opening Preparation

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

Basic Fitting Details No. 1

CROSSBAR RAFTER ISOMETRIC

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

How To Install Windows: Nail-Fin Application


RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

DBP Technical Data Series Rev. 0 Jan. 1, Pre Assembled Door Canopies

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

PRIMED STRAND REVERSIBLE SHAKE

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

Perimeter Edge Metal Brochure (COMGN296) Updated: 7/18

Technical Note No. 026

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

GLOSSARY OF TERMS SECTION 8

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

3M Air and Vapour Barrier 3015 Technical guide

INSTALLATION GUIDE LEARN MORE AT DECRA.COM

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SENTINEL SERIES 110 SINGLE HUNG WINDOWS

DIVISION 6 WOOD AND PLASTICS

KO LO SH E LT E R. High Capacity and Flexibility

Dura-Lock Roof System

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information

TIOGA Table of Contents

PRODUCT INFORMATION 0.145/0.130" 100 5,

UNA-CLAD Metal Roof Systems

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Installation Manual SOLID CORE SIDING

Transcription:

FLASHING SYSTEM ENGINEERED PRODUCT SYSTEMS PRODUCT BROCHURE

2 ND EDITION

FLASHING SYSTEM FUNCTIONALLY UNIQUE. ENGINEERED PRODUCT SYSTEMS / FLASHING Fry Reglet comprehensive selection of moisture prevention products offer the ultimate in protection from the elements. Available nationwide in a variety of materials and finishes, Fry Reglet offers five pre-engineered flashing systems tailored for specific substrates - all designed, tested and proven to keep wind and moisture from getting under the roof. Plus, Fry Reglet provides a complete solution with drawings, installation instructions and the best technical support in the industry. FEATURES AND BENEFITS Tested in accordance with ASTM D3161 - Wind Resistance to withstand 110 MPH sustained wind velocity for two hours without evidence of uplift (Class F) The Springlok flashing system is designed to hold the flashing tightly against the parapet wall. Reglets and flashing are roll formed to ensure precise fit and finish every time. Embossed end details precisely align each profile and provide an overlap for added protection against water penetration. Five reglet profiles are available for any type of commercial construction. PRODUCT DESCRIPTION: MATERIAL THICKNESS FINISH COLOR Galvanized Steel 24 gage Standard Zinc Finish N/A Galvanized Steel 26 gage Standard Zinc Finish N/A Copper 16oz Standard Uncoated Finish N/A Aluminum 0.025 / 0.040 Polyester Coating Gray Stainless Steel, Type 304 0.020 Standard Uncoated Finish N/A Sealant SM Reglet Flashing (SHOWN WITH SM REGLET) www.fryreglet.com 3

STX STUCCO REGLET Our NEW AND IMPROVED STX Stucco reglet now features a 3 1/2 vertical flange that provides for an easier installation and helps prevent moisture penetration. The STX Stucco reglet is specifically engineered for stucco over block conditions, and designed to accept Springlok flashing and other flexible flashing. FEATURES AND BENEFITS Redesigned with 3 1/2 vertical leg for ease of installation. A V projection allows stucco to be applied directly over reglet. Designed to eliminate a nailer or backing strip. 1 end lap allows for proper alignment and eliminates leaky butt joints. Roll-formed to ensure precise fit every time. PRODUCT DESCRIPTION: MATERIAL THICKNESS FINISH COLOR Galvanized Steel 24 gage Standard Zinc Finish N/A Galvanized Steel 24 gage Kynar 500/Hylar 500 Specify color Galvanized Steel 24 gage Factory applied powder paint Specify color Copper 16oz Standard Uncoated Finish N/A Aluminum 0.025 / 0.040 Polyester Coating Gray Stainless Steel, Type 304 0.020 Standard Uncoated Finish N/A STX Reglet 4 1/2 3 1/2 Flashing 7/8 4 www.fryreglet.com

ENGINEERED PRODUCT SYSTEMS / FLASHING SM SURFACE MOUNTED REGLET SM reglet is designed for installation on any type of parapet wall, including tilt-up panels, precast panels, masonry and other smooth surfaces. Reglets are surface mounted with drive pins which are sealed with special washers (7/8 diameter stainless steel with neoprene facing). FEATURES AND BENEFITS Factory punched slots at 16 o.c. allow for expansion and contraction. Washers and drive pins are included. Design provides two grooves for application of polyurethane, polysulfide or silicone sealant. 1 end lap allows for proper alignment and eliminates leaky butt joints. Roll-formed to ensure precise fit every time. PRODUCT DESCRIPTION: MATERIAL THICKNESS FINISH COLOR Galvanized Steel 24 gage Standard Zinc Finish N/A Galvanized Steel 24 gage Kynar 500/Hylar 500 Specify color Galvanized Steel 24 gage Factory applied powder paint Specify color Copper 16oz Standard Uncoated Finish N/A Aluminum 0.025 / 0.040 Polyester Coating Gray Stainless Steel, Type 304 0.020 Standard Uncoated Finish N/A Sealant SM Reglet Flashing 2 1/2 1/2 www.fryreglet.com 5

MA MASONRY REGLET Specially manufactured for masonry applications, this reglet is laid into masonry joints and held in place with mortar. FEATURES AND BENEFITS Encasing in mortar joint prevents against water penetration Type MA Reglet is designed with a 1 1/2 top flange for brick construction Type MA-4 Reglet is designed with a 4 flange for concrete block construction 1 end lap allows for proper alignment and eliminates leaky butt joints Roll formed to ensure precise fit every time PRODUCT DESCRIPTION: MATERIAL THICKNESS FINISH COLOR Galvanized Steel 24 gage Standard Zinc Finish N/A Galvanized Steel 24 gage Kynar 500 / Hylar 500 Specify color Galvanized Steel 24 gage Factor Applied Powder Paint Specify color Copper 16oz Standard Uncoated Finish N/A Aluminum 0.025 / 0.040 Polyester Coating Gray Stainless Steel, Type 304 0.020 Standard Uncoated Finish N/A MA Reglet 1 1/8 for Brick 4 for Concrete Block Flashing 1 1/8 1/2 6 www.fryreglet.com

ENGINEERED PRODUCT SYSTEMS / FLASHING ST STUCCO REGLET Made especially for stucco applications, the ST Stucco reglet is put in place over 3/4 baseboard prior to lathing. Springlok flashing is locked into place after the roofing paper is applied. Stucco is then applied over top. FEATURES AND BENEFITS Specifically designed for stucco applications where 3/4 baseboard is specified. 1 end lap allows for proper alignment and eliminates leaky butt joints Roll-formed to ensure precise fit every time PRODUCT DESCRIPTION: MATERIAL THICKNESS FINISH COLOR Galvanized Steel 24 gage Standard Zinc Finish N/A Galvanized Steel 24 gage Kynar 500/Hylar 500 Specify color Galvanized Steel 24 gage Factory applied powder paint Specify color Copper 16oz Standard Uncoated Finish N/A Aluminum 0.025 Polyester Coating Gray Stainless Steel, Type 304 0.020 Standard Uncoated Finish N/A ST Reglet Flashing 1 3/4 3/4 7/8 1/2 www.fryreglet.com 7

CO CONCRETE REGLET Used in poured-in-place concrete construction, this reglet is provided with a protective foam backer rod to prevent grout and concrete from entering the reglet opening. FEATURES AND BENEFITS Connector clips are included to provide positive alignment at joints Special staples are provided to simplify installation 1 end lap allows for proper alignment and eliminates leaky butt joints Roll-formed to ensure precise fit every time PRODUCT DESCRIPTION: MATERIAL THICKNESS FINISH COLOR Galvanized Steel 26 gage Standard Zinc Finish N/A Copper 16oz Standard Uncoated Finish N/A Aluminum 0.025 Polyester Coating Gray Stainless Steel, Type 304 0.020 Standard Uncoated Finish N/A CO Reglet Flashing 1 1/8 3/4 1/2 8 www.fryreglet.com

ENGINEERED PRODUCT SYSTEMS / FLASHING ACCESSORIES FACTORY FABRICATED REGLET CORNERS Factory fabricated reglet and flashing corners are mitered and sealed to help reduce installation time. Reglet corners are available in all material except aluminum. Flashing corners are available in all materials. STUCCO REGLET OUTSIDE CORNER SURFACE MOUNTED REGLET INSIDE CORNER MASONRY REGLET OUTSIDE CORNER CONCRETE REGLET OUTSIDE CORNER FLASHING OUTSIDE CORNER COLOR REGLETS & FLASHING Reglets and flashing are available with factory applied powder paint finishes in all standard colors. Special order pre-coated flashing and reglets in factory applied Kynar 500/Hylar 500 finishes. Contact Fry Reglet for colors, lead times and minimum order requirements. FLASHING INSIDE CORNER CONCRETE REGLET ACCESSORIES Connector clips provide positive alignment at joints and prevent concrete leakage during pouring. Installation staples secure reglet to forms prior to pouring. WINDLOK CLIP Optional pre-drilled 1 1/4 x 2 1/2 stainless steel metal straps designed to improve flashing performance in high wind locations by locking lower edge of flashing. Suitable for use with all reglets. VINYLOK FLASHING RETAINER Polyvinyl chloride Vinylok flashing retainer designed for tight spaces between parapet and cant strip where standard flashing will not fit. For use with ST stucco, STX stucco, MA masonry and SM surface mount reglets. Not for use with CO concrete reglet. Flexible flashing is installed to contact reglet. Vinylok retainer is pressed into area with tail flat against flashing. SURFACE MOUNTED REGLET SEALANT REGLET (TYPE SM) COUNTER FLASHING ("SPRINGLOCK") Factory provided foam insert for backer (dashed line indicates position when installed) Vinylok 1 1/8 DRIVE PIN & WASHER SEALANT VINYLOK SEALANT (Over entire end of system) FLEXIBLE FLASHING Note: Type "SM" Reglet illustrated FLASHING END CAP www.fryreglet.com 9

800-237-9773 www.fryreglet.com