Installation and Maintenance Manual HQ Release: February HQ Proportional Control Unit (PCU-A)

Similar documents
Subsea Valve Actuators

GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR

BFS / BFSM SERIES Installation & Maintenance Manual


ELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

MODEL: MRP6. Final Control Elements

Potentiometer Technical Manual Type

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

OPERATION MANUAL. Spring Return Actuator. Electrical Actuator. September, st

WE Series FEATURES OPTION CONFIGURATION STANDARD CONFIGURATION

Technical Manual Type: AI-V3/J

TMC3 SERVO CARD For WEM/XEM Series Actuators Installation & Maintenance Manual

AWWA. Electric Actuators WE Series Weatherproof CSA Approved TYPE 4 & 4X ,900 in-lbs. torque C CONTROLS

Installation, Operation & Maintenance Manual

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

OPERATION MANUAL. Linear Valve Actuator. Electrical Valve Actuator. September, nd

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

Value Valves USA. Electric Actuator DOUBLE ACTING SPRING RETURN.

Spring Return DuraDrive Proportional Actuator

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Ordering Information. Ratchet Relay G4Q. Model Number Legend

SETUP and OPERATING MANUAL ADVANCED MULTI-CHANNEL VEHICLE INTERCOM SYSTEM (AMCVIS)

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

ELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

PLE 2CS Plena Two-zone Call Station

VALVCON V Series Actuator. 115VAC and 230VAC

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Rotary actuators for ball valves

Technical Instructions Document No EA GQD June 23, OpenAir

This section is specifically about safety matters

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

LM Series Direct Coupled Actuator

M7061 ROTARY VALVE ACTUATORS

Installation & Operating Instructions

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual

OM Series Quarter Turn Electric Actuator

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES

Technical Instructions Document No P25 May 5, Reversing Actuators. Description

WD series DIN Rail or Screw Mounted Protective Relays

This section is specifically about safety matters

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Non-Spring Return EconoDrive Proportional Actuator

AE-504. Solid Start Paralleling Relay General Instructions OPERATIONS. Parallel. Control. Manual DEVICE INPUT OUTPUT

Overview of types. Technical data

Non-Spring Return DuraDrive Modulating Actuator

Solid-State Digital Counter H7AN

Rosemount 5408 and 5408:SIS Level Transmitters

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

PART # mA Positioner

O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS

Data Sheet for Precision Potentiometer

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data. Safety notes

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

n FRONT PANEL CONFIGURATIONS

VALVCON V-SERIES ACTUATOR 115VAC AND 230VAC

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

Compact Motorized Actuator

Emission-Pak Assemblies

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

AE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models

Daily Maintenance. 2. Insert bobbin cases in to rotary hooks. Make sure bobbin thread is not over 2 inches long. Close bobbin case covers.

Technical Document. for the. CB 016N6 Driver Card

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Parameterisable damper actuator in the

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

Functional data Factory settings Variable Settings

Dawson DDM190. Digital Multimeter User s Manual

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Electric Motor Actuator with a built in Microcomputer

Specifications of ASDA A2-E_220V Series

Rotary actuators for ball valves

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

COMPLY WITH HI-VOLTAGE PHASE CURRENT MEASUREMENT M-140HC INSTRUCTION MANUAL

Transcription:

Installation and Maintenance Manual HQ-401-0217 Release: February 2017 HQ Proportional Control Unit (PCU-A)

Service Instructions HQ-401-0217 Table of Contents February 2017 Table of Contents Section 1: Check Point Using Actuator... 1 Section 2: General Performance... 1 Section 3: Standard Specification... 2 Section 4: Function of PCU and How to Set and Use it... 3 4.1 Select input signal... 3 4.2 Set DIP switch for fail position... 3 4.3 Delay time... 4 4.4 Resolution... 4 4.5 Manual operation... 5 4.6 Special setting for full open and close... 5 4.7 Auto setting... 6 4.8 Split range (CH1)... 6 4.9 Reversal acting switch (CH2)... 7 4.10 Selection of output signal... 8 Section 5: Special Tools... 9 Section 6: Setting Potentiometer (Replacing and Setting)... 9 Section 7: Limit Switch Setting... 10 Section 8: Check Operation of PCU... 11 Section 9: Layout of PCU Card... 11 Section 10: Document Revision... 13 Table of Contents I

Table of Contents February 2017 Service Instructions HQ-401-0217 Table of Contents (continued) Appendix A: List of Tables... 14 Appendix B: List of Figures... 14 Appendix C: List of Drawings C.1 Dwg. No. HQ-15000-A, 1 Ph Wiring Diagram PCU... 15 C.2 Dwg. No. HQ-1500-A, 1 Ph Wiring Diagram Std... 16 *Thanks for purchasing our HQ series electric actuator. Before installing or operating actuator, please read this manual to thoroughly know how to install and operate this device. The contents of this manual are subject to change without notice due to continuously ongoing improvements. II Table of Contents

Service Instructions Section 2: Checking Points HQ-401-0217 February 2017 Section 1: Check point before using actuator 1. Check if specification (Model No., Main Power, Control Power, Options) of delivered actuator meets your requirements or not. 2. Check the application such as valve, damper & etc. 3. Check if mounting of actuator on application is correct and tight enough. 4. Check if settings of actuator such as limit switch, stopper bolts, indicator is correct or not. 5. Check if electric wiring is correct or not. 6. In case of 3-phase motor, check rotating direction. Check rotating direction of actuator Open actuator about 50% by manual, supply power to actuator for 2-3 seconds. Push close button and check if actuator closing direction is correct or not. If actuator is moving in the wrong direction, turn off power supply to the actuator and reverse the open and close lines from the PCU card. 7. Generally, all PCU functions are set in the factory before delivery and there is no need to set the functions again. Only in special cases where the customer wants to adjust the limit switches, is PCU function setting required. Setting is simple and only requires the pushing of the AUTO SETTING button after putting actuator in 50% open (or close) position. PCU automatically sets all the functions by itself. 8. Disassembly or modification without the factory's consent may affect the performance of the actuator. Section 2: General Performance The PCU is the local actuator controller, using 12-bit A/D converter and an 8-bit Microprocessor, which operates the open and close functions according to the input signal from main controller. After operating the actuator, the PCU detects the current position and transmits position feedback signals to the main controller. Checking Points 1

Section 3: Standard Specification February 2017 Service Instructions HQ-401-0217 Section 3: Standard Specification 1. Model: PCU REV A4 2. Power: 85V-260VAC +10% 50/60Hz 4VA Max (New Wide range of voltage) 3. Input signal: 4-20mA DC, 2-10V DC, 0-5V DC, 0-10V DC, 1-5V DC Input resistance: 250 Ohms, Feedback signal: 100-10K Ohm 4. Output signal: 4-20mA DC, 2-10V DC, 0-5V DC, 0-10V DC, 1-5V DC 5. Load resistance: 500 Ohms Max. 6. Control output: TRIAC contact 250VAC 16A Max (Inductive load) 7. Number of output contact: 2 each (Open and close contact) 8. Delay time adjustment: 0.05-7.5 sec (0Step 50msec 0-15 Step) 1-4 Step (Step Number X200msec) 5-15 Step (Step Number X 500msec) 9. Dead Band adjustment: 0.12mA DC MAX 10. Resolution Adjustment: 0 Step: 0.068mA 0-15 Step (Step Number +0.068mA) 11. Position conversion accuracy: +0.5 - +1.5% (Depends on installation) 12. Ambient temperature: 25 C - +80 C 13. Ambient humidity: 90% RH Max (Non-condensate) 14. Dielectric strength: 1500V AC 1 Min (Input to output, Power to Ground) 15. Insulation resistance: Min. 500V DC 30Mohm 16. Vibration & Shock (X, Y, Z); 10g (6g based on RMF, Frequency: 0.2-34Hz, 30 Min) 17. LED Signal Figure 1 LED Blue On Blue Flicker Green Flicker Green On Red Flicker Red On Yellow On Yellow Flicker PCB LED Panel SIGNAL Power On (AUTO) AUTO SETTING Closing Full Close Opening Full Open Manual Mode Fault in either No input signal, Wrong input wiring, Wrong PIU setting VIEW A 2 Standard Specification

Service Instructions Section 4: Function of a PCU HQ-401-0217 February 2017 Section 4: Function of a PCU and how to set and use it 4.1 Selecting of the input signal User can select suitable input signal by adjusting DIP switches as follows. Figure 2 1 2 3 Input DIP switch 4-20mA DC 1 2 3 2-10V DC Select input signal switch 0-10V DC 1-5V DC 1 2 3 1 2 3 0-5V DC 60 Hz 50 Hz 1 2 3 4 4 Select input Hertz switch VIEW B NOTE: If there is no instruction for the input signal, the default is 4-20mA. 4.2 Setting of fail position In order to prevent issues when the signal fails, the user can set the fail position of actuator by setting of DIP switches as follows. Figure 3 Fail position DIP setting Setting of fail position Switch (1,2) F CLOSE F OPEN A FULL CH1 CH2 1 2 3 4 5 1 2 3 4 5 FAIL CLOSE FAIL OPEN FAIL STOP VIEW C 1 2 3 4 5 1 2 3 4 5 Function of a PCU 3

Section 4: Function of a PCU February 2017 Service Instructions HQ-401-0217 4.3 Delay Time This prevents continuous operation of PCU card caused by abnormal signal input such as noise, microphone and other foreign frequency. Once the signal is detected, PCU follows that signal but if there is a preset time, PCU doesn't move within the time. PCU can move when input signal lasts a certain time which is preset. Turning the switch clockwise, increases delay Range 0.05-7.5 sec (0Step 50msec 0-15Step) 1-4 Step (Step Number X 200msec) 5-15Step (Step Number X 500msec) Figure 4 Delay rotary switch VIEW D D/B Delay time TIME 4.4 Resolution adjustment This is set allowance between input signal and position of actuator and if turned clockwise, sets it wider and vice versa. Please observe caution when turning this counter-clockwise because if it is too narrow, it could cause "HUNTING". HUNTING is an issue where the actuator doesn't stop at a position and repeats the move of open and close Dead Band adjustment: 0.12mA DC MAX Resolution Adjustment: 0 Step: 0.068mA 0-15Step (Step Number+0.068mA) Figure 5 Resolution adjustment switch OPEN DEAD BAND TARGET Resolution Adjustment VIEW D CLOSE NOTE: HUNTING is one of the causes of motor burning and damage of potentiometer and PCU card. 4 Function of a PCU

Service Instructions Section 4: Function of a PCU HQ-401-0217 February 2017 4.5 Manual operation by PCU card In order to operate actuator by card, press ZERO and SPAN buttons together for 2 seconds. The yellow LED will turn on to confirm manual operation mode. If ZERO button is pushed, actuator will move to close and if the SPAN button is pushed, the actuator will move to open. Left alone for 15 seconds without operation, PCU will come out from manual operation mode. NOTE: (During manual operation mode, input signal is ignored) Figure 6 Manual operation button zero close span open Manual Operation Button VIEW E 4.6 Special signal setting for full open and full closed Figure 7 Special setting switch Special setting switch F CLOSE F OPEN A FULL CH1 CH2 VIEW C 1 2 3 4 5 "3 " Up : Signal : 4.3mA Full Closed Signal : 19.7mA Full Open "3 " Down : Signal : 4mA Full Closed Signal : 20mA Full Open Function of a PCU 5

Section 4: Function of a PCU February 2017 Service Instructions HQ-401-0217 4.7 AUTO SETTING If mounting between actuator and application is correct, and input signal, input power and wiring are correct, push AUTO SETTING button just once regardless of the position of actuator. Then Blue LED flickers with indicating LED as following: 1) Opening with Red LED in 5 sec-> 2) Full Close with Green LED-> 2) Full Open with Red LED. NOTE: Please make sure that Limit Cam touches (Open/Close) Limit Switch while Autosetting. Figure 8 AUTO SETTING button zero close span open AUTO SETTING AUTO SETTING BUTTON OPEN AUTO CLOSE FAULT LD1 LD2 LD3 LD4 VIEW E 4.8 Split range (CH1) The Split range is a useful function that allows the customer to set the actuator to full close and full open position using a signal if the input signal is not precise. If customer wants to set actuator to full close position at 5mA, supply 5mA DC and actuator moves to the position. Then put CH1 DIP switch on and push ZERO button once. Then actuator acknowledges that position as full close position and transmits 4mA DC. Open set is same but instead, push SPAN Button. Once setting is done, put CH1 DIP switch off. Adjustable range is: Close: 3-8mA DC Open: 16-21 ma DC NOTE: By using this DIP switch, the customer may set various positions at certain signal. 6 Function of a PCU

Service Instructions Section 4: Function of a PCU HQ-401-0217 February 2017 Figure 9 CH1 DIP switch zero close span open AUTO SETTING LD1 LD2 LD3 LD4 OPEN AUTO CLOSE FAULT CH1 F CLOSE F OPEN A FULL CH1 CH2 1 2 3 4 5 4.9 Reversal acting switch (CH2) Generally, clockwise-rotating direction of actuator is to close but if user wants reverse action, please do the following: Switch "5 " Up VIEW C : Signal : 20mA Full Closed Signal : 4mA Full Open Switch "5 " Down : Signal : 4mA Full Closed Signal : 20mA Full Open Put the actuator to 50% open (or close) position, and push the AUTO SETTING button. Supplying 4-20mA, check operation and rotating direction. Figure 10 zero close span open CH2 DIP switch AUTO SETTING LD1 LD2 LD3 LD4 OPEN AUTO CLOSE FAULT CH2 F CLOSE F OPEN A FULL CH1 CH2 1 2 3 4 5 VIEW C Function of a PCU 7

Section 4: Function of a PCU February 2017 Service Instructions HQ-401-0217 4.10 Selection of output signal The user can select suitable output signal by adjusting DIP switches as follows: Figure 11 Output selection DIP switch 1 2 4-20mA DC 1 2 0-10V DC 2-10V DC 1 2 0-5V DC 1-5V DC Select output signal by dip switch VIEW F NOTE: If there is no instruction for the input signal, 4-20mA is the factory default signal setting. Adjust zero or span volume switch to meet the exact value of output signal in accordance with input signal value. 8 Function of a PCU

Service Instructions Section 5: Special Tools HQ-401-0217 February 2017 Section 5: Special tools 1. L -Wrench 1 set (metric) 2. Screw driver(-) 3. Monkey spanner (1 set) 4. DC signal generator (0-24mA DC) 5. Multi-meter 6. ma DC meter (0-25mA DC) Section 6: Setting potentiometer (Replacing and setting) 1. Put actuator into full close position 2. Take P1 and P2 and measuring its resistance, turn potentiometer until it reaches a value between 30-100 Ohm. 3. Engage the potentiometer gear into main gear and tighten the screw. Figure 12 Potentiometer schematic Special Tools 9

Section 7: Limit Switch Setting February 2017 Service Instructions HQ-401-0217 Section 7: Limit switch setting 1. Pull over the lever for manual operation and turn hand wheel to move actuator to full close (or open) position. 2. Loosen the bolts tightening cam by L-wrench, and turn CLS (or OLS) cam to CW (or to CCW), so that cam may hit the lever of close (or open) limit switch. Then tighten the bolt by L-wrench. Figure 13 Potentiometer internal switch layout 10 Limit Switch Setting

Service Instructions Section 8: Check Operation of PCU HQ-401-0217 February 2017 Section 8: Check operation of PCU Table 1. PCU operation legend Actuator Full Close Full Open Input signal 4mA DC (1V DC, 2V DC) 20mA DC (5V DC, 10V DC) Output signal 4mA DC 20mA DC Signal LED Green LED on Red LED on Auto setting Input signal failure Blue LED flicker Yellow LED flicker Section 9: Layout of PCU Card Figure 14 PCU Card component layout and function Check Operation of PCU 11

Section 9: Layout of PCU Card Service Instructions HQ-401-0217 February 2017 Figure 15 PCU Card PCB layout and function highlight views View E View A View F 12 View C View D View B Layout of PCU Card

Service Instructions Section 10: Document Revision HQ-401-0217 February 2017 Section 10: Document Revision Table 2. Revision Overview ECN DATE REV BY * DATE Released COMPILED C. Rico December 2013 Reviewed December 2013 1 CHECKED D. Hoke December 2013 Approved APPROVED D. Hoke December 2013 Document Revision 13

Appendix February 2017 Service Instructions HQ-401-0217 Appendix A: List of Tables Table 1. PCU Operation Legend... 11 Table 2. Revision Overview... 13 Appendix B: List of Figures Figure 1. PCB LED Panel... 2 Figure 2. Input DIP switch... 3 Figure 3. Fail position DIP setting... 3 Figure 4. Delay rotary switch... 4 Figure 5. Resolution adjustment switch... 4 Figure 6. Manual operation button... 5 Figure 7. Special setting switch... 5 Figure 8. AUTO SETTING button... 6 Figure 9. CH1 DIP switch... 6 Figure 10. CH2 DIP Switch... 7 Figure 11. Output selection DIP switch... 8 Figure 12. Potentiometer schematic... 9 Figure 13. Potentiometer internal switch layout... 10 Figure 14. PCU Card component layout and function... 11 Figure 15. PCU Card PCB layout and function highlight views... 12 14 Appendix

Service Instructions Appendix HQ-401-0217 February 2017 Appendix C: List of Drawings C.1 Dwg. No. HQ-15000-A, 1 Ph Wiring Diagram PCU Appendix 15

Appendix February 2017 Service Instructions HQ-401-0217 C.2 Dwg. No. HQ-1500-A, 1 Ph Wiring Diagram Std. 16 Appendix

World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers. Choose the WACC or sales office nearest you: NORTH & SOUTH AMERICA MIDDLE EAST & AFRICA EUROPE ASIA PACIFIC 13840 Pike Road Missouri City, Texas 77489 USA T +1 281 499 1561 F +1 281 499 8445 19200 Northwest Freeway Houston TX 77065 USA T +1 281 477 4100 F +1 281 477 2809 Av. Hollingsworth, 325, Iporanga Sorocaba, SP 18087-105 Brazil T +55 15 3238 3788 F +55 15 3228 3300 P.O. Box 17033 Dubai United Arab Emirates T +971 4 811 8100 F +971 4 886 5465 P.O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650 F +966 3 340 8790 24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908; Greenstone; 1616 Modderfontein, Extension 5 South Africa T +27 11 451 3700 F +27 11 451 3800 Berenyi u. 72-100 Videoton Industry Park Building #230 Székesfehérvár 8000 Hungary T +36 22 53 09 50 F +36 22 54 37 00 No. 9 Gul Road #01-02 Singapore 629361 T +65 6501 4600 F +65 6268 0028 9/F Gateway Building No. 10 Ya Bao Road Chaoyang District Beijing 100020 P.R.China T +86 10 5821 1188 F +86 10 5821 1100 1277 Xin Jin Qiao Road Jin Qiao Export Processing Zone Shanghai 201206 P.R.China T +86 21 2892 9000 F +86 21 2892 9001 For a complete list of sales and manufacturing sites, please visit www.emerson.com/actuationtechnologieslocations Or contact us at info.actuationtechnologies@emerson.com www.emerson.com/eim All Rights Reserved. We reserve the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson product remains solely with the purchaser. 2017 Emerson.