OPTIMIZING SPATIAL RESOLUTION WITH THE MECHANICAL DESIGN OF AN X-RAY COMPU1ED TOMOGRAPHY SCANNER

Similar documents
Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

QC Testing for Computed Tomography (CT) Scanner

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY

v tome x m microfocus CT

COMPUTED TOMOGRAPHY 1

Photomultiplier Tube

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Nuclear Associates , , CT Head and Body Dose Phantom

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Clinical Importance on CT

Explain what is meant by a photon and state one of its main properties [2]

Physics 3340 Spring Fourier Optics

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

Data. microcat +SPECT

A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

Thermionic x-ray. Alternative technologies. Electron Field Emission. CNT Based Field Emission X-Ray Source

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Discover the difference in efficiency

An experimental method for ripple minimization in transmission data for industrial X-ray computed tomography imaging system

I. Introduction.

Detector technology in simultaneous spectral imaging

Image Quality and Dose. Image Quality and Dose. Image Quality and Dose Issues in MSCT. Scanner parameters affecting IQ and Dose

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Principles of CT scan

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Reconstruction Filtering in Industrial gamma-ray CT Application

5th International Symposium on NDT in Aerospace, 13-15th November 2013, Singapore

diagnostic examination

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Single Slit Diffraction

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

An Activity in Computed Tomography

PD233: Design of Biomedical Devices and Systems

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Laser Beam Analysis Using Image Processing

Suppression of metal artifacts using image-based monoenergetic DECT imaging

Four-dimensional Computed Tomography (4D CT) Concepts and Preliminary Development

arxiv:physics/ v1 [physics.optics] 12 May 2006

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

80 Physics Essentials Workbook Stage 2 Physics

An Activity in Computed Tomography

160-slice CT SCANNER / New Standard for the Future

REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

2017 West Coast Educators Conference Orlando. Projection Geometry. 1. Review hierarchy of image qualities (amplified version):

Opto Engineering S.r.l.

(Refer Slide Time: 00:10)

PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, Edited by

Exercise 1-4. The Radar Equation EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION OF FUNDAMENTALS

Comparison of FRD (Focal Ratio Degradation) for Optical Fibres with Different Core Sizes By Neil Barrie

Quality Control for X-Ray Systems A Tool Chain for NDT Applications

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Chapter 36: diffraction

abc MHRA Philips Mx8000 IDT CT scanner technical evaluation September 2004 Best choice best practice nww.medical-devices.nhs.

Coherent Laser Measurement and Control Beam Diagnostics

X-rays in medical diagnostics

CT Basics: Data Acquisition Module 3

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

Experimental demonstration of polarization-assisted transverse and axial optical superresolution

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

Test procedures Page: 1 of 5

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

MICROWAVE THICKNESS MEASUREMENTS OF MAGNETIC COATINGS. D.D. Palmer and V.R. Ditton

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

White Paper: Modifying Laser Beams No Way Around It, So Here s How

Introduction To NDT. BY: Omid HEIDARY

CyberKnife Iris Beam QA using Fluence Divergence

Alignment of the camera

Phase Imaging Using Focused Polycapillary Optics

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Tutorial: designing a converging-beam electron gun and focusing solenoid with Trak and PerMag

Mammography: Physics of Imaging

Observation of X-rays generated by relativistic electrons in waveguide target mounted inside a betatron

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2

X-RAY COMPUTED TOMOGRAPHY

Computed Radiography

Digital Radiography and X-ray Computed Tomography Slice Inspection of an Aluminum Truss Section

1. Patient size AEC. Large Patient High ma. Small Patient Low ma

RaySafe X2. Effortless measurements of X-ray

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Functions of the SEM subsystems

Application Note (A11)

LENSES. a. To study the nature of image formed by spherical lenses. b. To study the defects of spherical lenses.

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

Digital Radiography : Flat Panel

Manufacturing Metrology Team

Ayaz Jhanorwala, Rishikesh Kumar, Satish Tilva. L & T MHPS Boilers Pvt Ltd., Hazira, Surat , India

Transcription:

OPTIMIZING SPATIAL RESOLUTION WITH THE MECHANICAL DESIGN OF AN X-RAY COMPU1ED TOMOGRAPHY SCANNER Lowell D. Harris, RichardT. Bernardi, Simon H. C. Hughes, and Robert E. Slocum Bio-Imaging Research, Inc. 425 Barclay Blvd. Lincolnshire, IL 60069 INTRODUCTION With an understanding of the x-ray physics of a computed tomography (CT) [1-4] scanner with discrete detectors, and with knowledge of the scanner's geometry (the spatial relationship among the x-ray source, the detectors, and the object being scanned), it is possible to predict the achievable spatial resolution in images of objects of a certain size and density. However, if the size of the x-ray focal spot must be changed or if an object larger or smaller than the one for which the scanner is optimized is to be scanned, the spatial resolution may change. To maximize spatial resolution for a range of objects and x-ray sources, a scanner can be designed with a variable geometry, so that the spatial relationship of the scanner components can be changed to best fit each application. This paper first describes how the scanning geometry is related to spatial resolution, then illustrates how the geometry must differ for optimal scanning of different objects. We then describe the Advanced Computed Tomography Inspection System (ACTIS), a secondgeneration CT scanner with multiple x-ray sources and a variable geometry, emphasizing the features that allow optimal and convenient scanning of a wide range of objects. DE1ERMINING MAXIMUM SPATIAL RESOLUTION Contrary to a popular misconception, the spatial resolution of a CT scanner is not limited by sampling, provided the scanner is well designed. Since the sample spacing should be set fine enough to avoid aliasing, all available fine detail will be reproduced and the spatial resolution will be limited by other factors [5-7]. The most elemental of these are two factors related to properties of the x-ray beam itself: the profile of the beam between the x-ray focal spot and the detector, and the position of the object being scanned in relation to the focal spot and detector. The first factor, the beam profile, varies with focal spot size, detector aperture, and position between the source and detector. Figure 1 shows an x-ray focal spot at the top and a detector at the bottom. (The dimensions of the focal spot and detector aperture are exaggerated with respect to the distance between them to illustrate the concept.) Each point of the focal spot emits a fan of radiation; in the figure we see fan beams from both edges of the focal spot. While the beam most likely covers an area wider than the detector, all that is significant is the part that strikes the detector. If we consider the sensitivity of this beam to an object placed within it, we find that the profile of the sensitivity varies with position. For instance, if a lead sheet is passed across the beam immediately in front of the detector (point A in the figure) or the focal spot (point B), the amount of the beam that is blocked will be directly proportional to the amount of the surface area that is covered: the profile will be a Review of Progress in Quantitative Nondestructive Evaluation, Vol. 9 Edited by D.O. Thompson and D.E. Chimenti Plenum Press, New York, 1990 423

rectangle. However, if the lead sheet is passed across the beam at the midpoint, point C in the figure, it will block only a small percentage of the x-rays as it passes through the edge of the beam. As it moves across the beam, it blocks increasingly more x-rays until it reaches the center. The proftle at this point, therefore, is a triangle. At other points within the beam, such as point D, the profile will be unifonnly sensitive near the center of the beam but will fall off at the edges, forming a trapezoid. To illustrate how this variance in profile relates to spatial resolution, we must consider the beam width along the length of the beam. At point D in Figure I, the thick line is the beam width measured using the full width at half maximum (FWHM). If the endpoints of the FWHM lines along the entire length of the beam are plotted, the result is the beam shape shown in Figure 2a. The beam width is as wide as the focal spot and the detector aperture at the respective ends of the beam, but it narrows to a thin waist at some point in between. The point at which the beam width is smallest is known as the half power crossover. Figure 2b gives formulas for the beam width at different positions between the focal spot and the detector. Note that the only variables in the formula for the beam width at the half power crossover are the focal spot width and the detector aperture; therefore, the minimum beam width is independent of its position between the focal spot and detector. X-Ray Focal Spot Beam Width Measured Using FWHM Beam Sensitivity Profile - Changes With Position Detector Figure I. The drawing illustrates the beam sensitivity profile for different positions along the beam path. Detector Minimum Beam Width (Half Power Crossover} T Source Detector Distance (SOD) \E--_;_.;, -T'" -r. b J -,%-wh' ~ ~ ~ SOD - y x S SOD _ L ~ Detector (D mm) Figure 2. Drawing a shows the beam width obtained by plotting the FWHM lines; drawing b gives formulas for the beam width in different regions of the beam path. 424

Of course, changing the dimensions of the focal spot or detector will change the width of the beam. Figure 3 is a graph plotting the beam width for two focal spots, 2 mm and 1 mm, with a detector aperture ofl mm. The beam width is smaller with the 1 mm source and, since the focal spot width and detector width are the same, the half power crossover is halfway between the source and detector. The graph not only illustrates that a smaller beam width is achieved with a smaller focal spot (or a smaller detector), but shows that making such a change also changes the location of the half power crossover. This becomes important when a scanner uses more than one x-ray source, or an x-ray source with more than one spot size, in order to provide the best density resolution for objects with different attenuation. The position of the half power crossover is an important consideration in scanner design because spatial resolution is limited by the beam width as the beam passes through the object being examined. The resolution, in fact, is essentially equal to the width of the beam in the part of the object that is closest to the detector. This leads to the second factor in determining spatial resolution, the position of the object in relation to the focal spot and detector. Since the spatial resolution is greatest when the beam passing through the object is narrowest, the object should be positioned at the half power crossover for optimal resolution. Theoretically, one could also increase the resolution by decreasing the focal spot size or detector aperture. It is important to note, however, that the laws of physics preclude decreasing the focal spot size and detector aperture arbitrarily. The energy of the x-ray emission must be spread out over a certain area to avoid melting the anode, and the detector must have a large enough area to receive a significant number of x-ray photons. OPTIMIZING A Cf SYSTEM FOR AN APPLICATION With the knowledge from the above section, we can design a scanner that will have the mounting device for the object positioned so that a certain object will be at the half power crossover. For instance, if we have a scanner with a focal spot size of 1 mm, a detector aperture of 1 mm, and a source-to-detector distance of 1.5 m, and we want to optimize it for turbine blades (maximum dian1eter of 5 em), we can place the turbine blade halfway between the source and detector as shown in Figure 4 and scan it with a spatial resolution of 0.5 mm. This equals a cutoff frequency of 2 line pairsmm, as defined by equation 1. 2 source = 2 mm detector= 1 mm Beam Width (mm)..., source Position detector Figure 3. The graph shows beam width as a function of position between the source and detector for two focal spot sizes. 425

1 Cutoff (lpmm) = Beam Width(mm) (1) But what if we want to scan a larger object-for example, a rocket exit cone 0.5 meter in diameter-with this scanner? H the cone is placed on the mounting device in the center of the scanner, its wall will be intersected by the beam as shown in Figure 4. The width of the beam as it passes through the wall will be 0.667 mm, giving a cutoff frequency of 1.5 lpmm. Thus, the same scanner will scan two different objects with different resolutions. To optimize the scanner for the exit cone, it will have to be constructed with the mounting device placed so that the wall of the exit cone closer to the detector is at the half power crossover, as shown in Figure 5. Though there are now two beam widths passing through the cone (0.833 mm and 0.5 mm), experience has shown that the minimum beam width dominates on a 360. scan. Note also that when the turbine blade is mounted on this scanner, it is intersected by a beam with a width of 0.667 mm (1.5 lpmm). 2 Beam Width (mm) turbine blade source Position detector Figure 4. The graph shows the beam width as the beam passes through a turbine blade and an exit cone when the geometry is optimized for the turbine blade. 2 Beam Width (mm) 1 turbine blade exit cone source Position detector Figure 5. The graph shows the beam width as the beam passes through a turbine blade and an exit cone when the geometry is optimized for the exit cone. 426

2 Beam Width (mm) turbine blade exit cone source Position detector Figure 6. The graph shows the beam width as the beam passes through a turbine blade and an exit cone when an x-ray source with a 2 mm focal spot is used. As a further complication, suppose that more x-ray penetration is needed and an x-ray source with a 2 mm focal spot size is installed. Figure 6 is a modification of Figure 4 with the focal spot size increased to 2 mm. This geometry will now no longer be optimized for the turbine blade, as the blade will be intersected by a beam I mm wide, giving a cutoff frequency of 1.0 lpmm. Rather, the exit cone will be scanned with better resolution, as the beam width is 0.667 (1.5 lpmm) as it passes through the cone wall closest to the detector. Clearly, scanner geometry is application-specific. If one has a need for a large range of x-ray power (which will require multiple sources with different focal spot sizes) and a range of object sizes, significant compromises in spatial resolution will have to be accepted for some objects, or else a method of changing the geometry will have to be implemented. THE VARIABLE GEOMETRY DESIGN OF ACfiS ACfiS was conceived as a scanner that would scan both large (up to 1828 mm in diameter) and small (a few centimeters) objects with the best possible density and spatial resolution for each object. As described in the previous sections, there are two general requirements for imaging such a wide range of objects: multiple x-ray sources to penetrate objects of all sizes and densities with optimum density resolution, and a variable geometry to allow source and detector positioning for optimum spatial resolution. ACTIS operates in several scan modes, each of which is designed to optimally image a certain type of object. These modes are programmed before delivery and are based on the customer's expected applications. The system software allows the user to program additional modes. Data collection parameters (number of views, samples per view, integration time, etc.) for each mode are set so that the ultimate spatial resolution is limited by beam width considerations. The mechanical positioning precision and accuracy are in excess of the limit required to support the highest spatial resolution. Figure 7 is a concept drawing of the ACTIS gantry which illustrates the variable geometry and multiple sources. Up to three sources can be mounted on the source tower to the left. The detector box, containing a linear array of discrete solid-state detectors, is shifted along the x axis in the drawing to align the detectors with the source being used. The standard source is a 320 kv x-ray tube with small (0.8 mm) and large (1.8 mm) focal spots. With the two spot sizes, this tube's output allows scanning over the range of resolution and 427

aperture designed into ACTIS. Optional sources include 150 kv or 420 kv conventional x ray tubes, a 150 kv microfocus x-ray tube, a cobalt 60 isotope source, or a linear accelerator with energy ranges up to 16 MeV. The smaller sources will produce better images on certain objects, such as nozzles with thinner walls. The larger sources provide more x-ray penetration for large or dense objects. Since the linear accelerators are pulsed rather than continuous output sources, their pulses are synchronized with the integrator circuit trigger in the detector system. The source tower, on the left in Figure 7, and the detector tower, on the right, both move along the y axis to provide the variable geometry capability. The object is mounted in the center of the turntable, which rotates and moves along the x axis. Each of the preprogrammed modes has a system geometry that automatically positions the source and detectors at the correct distance from the object in addition to adjusting the data collection and reconstruction parameters. These positions can be manually changed (through software) as well to optimize the geometry for each particular object. The visible spatial resolution of the system ranges from 5.1 to 19.2line pairsem as defined by a Rayleigh criterion (17% dip between maxima) for standard line pair gauges made up of alternating strips of dense and very light materials using a 10 mm slice width. The following tables present an example of how ACTIS can be equipped and programmed, using the standard 320 kv dual focal spot source, a 420 kv dual focal spot x-ray tube, and a 2 MeV Linatron linear accelerator. This range of sources provides a maximum density resolution of 0.5% for a 1 cm2 region when a 360" scan is performed. Table 1 gives the physical dimensions of each of three typical preprogrammed geometries. (ACTIS can be programmed for up to seven geometries.) The fan angle is the angle of the x-ray beam that is subtended by the detector array. Table 2 presents the spatial resolution and scan time performance for 15 different scanning configurations. The spatial resolutions listed in Table 2 are cutoff values. Actual visible resolution by the Rayleigh z X y X y Figure 7. The drawing shows the mechanical configuration of ACTIS. The source tower on the left, which holds up to three x-ray sources, and the detector tower on the right both move along they axis to vary the scanner geometry. 428

Table 1. ACfiS System Geometry Fan Angle Source-detector Source-object Scan field Geometry (deqrees) distance (mm) distance (mm) diameter (mm) 1 36.0 1330 760 380 2 25.7 1881 992 635 3 20.0 2464 1385 1270 Table 2. Performance for ACTIS Scan Modes Spot Spatial res. Scan time Scan Mode Source size Geometry (lpcm) (minutes) 1 320kV small 0.8mm 1 24.1 8.4 2 320kV small 0.8mm 2 24.2 10.2 3 320 kv small 0.8mm 3 19.8 34.8 4 320kV large 1.8 mm 1 14.9 8.9 5 320kV large 1.8 mm 2 14.2 15.2 6 320kV large 1.8 mm 3 13.9 25.7 78 420kV small2 MeV 2mm 1 14.0 3.5 910 420 kv small2 MeV 2mm 2 12.9 6.5 1112 420 kv small2 MeV 2mm 3 13.1 11.1 13 420kV large 4mm 1 7.0 2.0 14 420 kv large 4mm 2 6.4 3.1 15 420 kv large 4mm 3 8.4 7.5 criterion is approximately 80% of the cutoff value. Each spatial resolution figure quoted is the average over the entire scan field for that mode; the figure is less than the maximum resolution attainable at the half power crossover. All scan times are representative of average sample integration periods. The noise characteristics ofresulting images can be controlled by varying the sample time, which ultimately determines the scan time. As mentioned previously, these or other scan modes can be preprogrammed to achieve optimal performance for an expected mix of applications. The user can select any preprogrammed mode by pressing two console buttons. It is also possible to define new scan modes as the need arises. The selection of source-detector and source-object distances is limited only by the physical constraints of gantry dimensions. CONCLUSION We have described the most important factor limiting spatial resolution in a welldesigned CT scanner-the x-ray beam width as it passes through the object being examined. Since this factor is dependent on a number of properties, including object size and density, distance from the radiation source to the object, and distance from the source to the detectors, a scanner that is to effectively image a number of different objects must have some way of varying the spatial relationship among the source, object, and detectors (known as the system geometry). We have described ACTIS, a second-generation CT scanner that has a variable geometry to allow a wide variety of objects to be scanm;d at peak spatial resolution, even with different radiation sources. The design of this system gives the user great flexibility in many x-ray imaging applications. 429

REFERENCES 1. R. Gordon and G.T. Herman, "Three-dimensionill reconstruction from projections: A review of algorithms", Int. Rev. Cytol., 38, 111-151, 1974. 2. R.D. Brooks and G. DiChiro, "Principles of computer assisted tomography (CAl) in radiographic and radioisotopic imaging", Phys. Med. Biol., 21, 689-732, 1976. 3. R.A. Robb, "X-ray computed tomography: An engineering synthesis ofmultiscientific principles", CRC Crit. Rev. Biomed. Eng. 7(4), 263-334, 1982. 4. M.M. Ter-Pogossian, "Basic principles of computed axial tomography", Semin. Nucl. Med., 7, 109-127, 1977. 5. E. C. McCullough, "Specifying and evaluating the performance of computed tomography (Cl) scanners", Med. Phys., 7, 291-298, 1980. 6. D.J. Goodenough, K.G. Weaver, and D.O. Davis, "Development of a phantom for evaluation and assurance of image quality in CT scanning", Opt. Eng. 16, 52, 1977. 7. E.A. Sivers, D.O. Tonner, I.H. Stanley, and J.F. Moore, "Performance of Imaging Systems", Standanl Guide for Computed Tomography Imaging (ed. D.O. Tonner), ASTM (in press). 430