DS3880R1114. Fibrolan broad portfolio of optical transceivers include SFP+ and XFP series

DS3880R1115. Fibrolan broad portfolio of optical transceivers include SFP+ and XFP series

CWDM Cisco CWDM wavelengths (nm)

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DWDM Dual Fiber series

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

Overview. Highlights. General Specification. Datasheet

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

OPCOM100-DMU40 40-Channel DWDM. Mux/Demux. Typical Application. Figure.1 Point to Point Topology. Datasheet. Raisecom Technology Co., Ltd.

Class 1 LED of 850 nm for (short-range) applications. Class 1 laser of 1300 nm for (medium-range) applications.

Dual & Single Fiber Compact CWDM Mux Demux

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

XSD Single Fiber series DWDM passive optical components

WaveSmart Wave Division Multiplexing (WDM)

GT Channel Ultra Compact CWDM Mux & DeMux

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

Datasheet. 40ch DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC. Overview. Highlights

Wave Division Multiplexing. Passive Mux/Demux Modules & Cables. Datasheet. Features. Overview. Typical 2-Channel Passive Mux/Demux Application

Optical Transceivers. May

WaveReady CWDM Add/Drop for OSP Splice Enclosure

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

Wavelength Converter Specification: WX-1000

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM. Typical Application. Figure.1 Chain Topology. Datasheet. Raisecom Technology Co., Ltd.

Pluggable Transceiver Modules

Passive WDM Networking

16 Channels C21-C36 Dual Fiber DWDM Mux Demux, w/expansion Port 1U Rack Mount, LC/UPC

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Pluggable Transceivers

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Small form-factor pluggable (SFP) components

CWDM Single Fiber series

WaveReady Single-Channel DWDM Add/Drop for OSP Splice Enclosure. MDF-01AD10xx0

Optical Passives (ISP)

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

Transceiver, Chassis Connectors, and Cable and Adapter Specifications

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO

WaveReady 8-Channel DWDM OSP Optical Add/Drop Multiplexer for Splice Enclosures. MDF-08MD1N0xB and MDF-08MD1Z0xB

GYM Bilgi Teknolojileri

OPC1600 MUX WDM OADM SPLITTER

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

Why Using Fiber for transmission

Good Things Come in Small Cubes. Cube Optics 100G Metro Evolution TREX14 01/06/14

LEAD Fiber Optics PRODUCT CATALOGUE

Updated in 2017 Free Product Guide for Your Network. Transceiver. Catalog

Digital Return System

Odd. Even. Insertion Loss (db)

Optical Transport Technologies and Trends

OMxxDyy-100zz-ab:cd-(M5)-XXYY

Fiber Optic Principles. Oct-09 1

Digital Return System

Technical Specifications

Prisma DWDM Passives. Features. Optical Passive Components

SERIES DL221 10/100 ETHERNET TRANSCEIVER USER MANUAL

Transceiver Ordering Guide

CWDM PLUS/MAX Series OVERVIEW KEY FEATURES AND BENEFITS TECHNOLOGY.

Qualifying Fiber for 10G Deployment

100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100)

DWDM Mux/Demux product range

Cisco Prisma Optical Passive Components

Further more all functions as well available in splice trays or splice enclosures (-40 to 85 C)

Wavelength Multiplexing. The Target

User Manual. Installation Transmit Receive Module SFP/XFP

RXT-1200 Modular Test Platform

Prisma and Laser Link DWDM Passives for LGX-Compatible Systems

VePAL UX400 Universal Test Platform

LEAD Fiber Optics PRODUCT CATALOGUE

WDM. Coarse WDM. Nortel's WDM System

4 Gigabit CWDM SFP CWDM SFP Transceiver RoHS Compliant Specification: F416S174XX-D

Technical Specifications

Table of Contents INTERCONNECTS / CABLE ASSEMBLIES / PATCH PANELS

OC-48 SR-1 / STM I16.1 Long wavelength SFP Transceiver RoHS, SFF-8472 Compliant Specification: F414S17413-D

DATASHEET 4.1. XFP, 10GBase-ZR, Multirate Gbps, DWDM 50GHz, SM, DDM, 24dB, 80km

CM /100/1000BASE-T

X2-10GB-Cxx-ER CWDM X2-10GBASE, 40km Reach

SFP-GE-LX Gigabit Ethernet-Singlemode Transceiver SFP, Duplex LC Connector, 1310nm DFB 40km for Single Mode Fiber, RoHS Compliant

Cable and Port Specifications

Presentation Overview

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

GBS-9280-CXX0 5V / CWDM / Gb/s Single-Mode Gigabit Interface Converter (GBIC)

DS10-F007. Datasheet. Initial Date R&D Dept. GH Zheng. OE OFD6xx418 Written Team. PN OFD6xx418 Description XFP, DWDM 80KM

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Cisco s CLEC Networkers Power Session

Dense Wavelength Division Multiplexer (DWDM) 200 GHz Spacing, Multi-Channel, 2ch, 4ch, 8ch, 16ch, 20ch in PEACOC Flexible Tray

Figure 1. Smartoptics MUX

Company Profile. (MEMS) technology, along with our

Multi-Rate up to 2.7G 18 CH CWDM SFP Transceiver RoHS, SFF-8472 Compliant Specification: F419S174XX-D

10Gbps XFP Optical Transceiver RTXM226-6XX

Opti Max Optical Node Series

Optical Passives and Accessories

Transcription:

WDM -Transmission The recent progress in telecommunication applications for voice, video and data has placed additional demands for fiber optic networks. Adding more fiber to existing networks can be cost- prohibitive to service providers. A better and less costly solution is provided by WDM technology. Fibrolan s WDM series include MetroStar Modules, small form Stand-alone devices, and comprehensive DWDM over CWDM solutions. The WDM equipment includes Multiplexers, OADMs, Transponders and SFP interfaces. Fibrolan s WDM series comprises a set of WDM building blocks, with channels each supporting 10Gb bandwidth, in addition to the full facilities of the MetroStar System. Monitor ports allow live monitoring and troubleshooting of the WDM signals. Fibrolan s WDM equipment allows users and service providers to increase the capacity of the existing fiber with CWDM wavelengths and DWDM channels. Fibrolan WDM provides attractive solutions for large enterprise and carriers: stronger than traditional CWDM, more economical than DWDM. This section includes a condensed list of all SFP transceivers used in Fibrolan products. (see end of section) V-1

Dual channels MUX/DEMUX Wavelength: 1310nm/1550nm Duplex LC connectors Dual slot module/device type Half 19 /1RU enclosure Insertion Loss: Pass Channel (1550nm) = Max.=0.7, Typical =0.5.dB Reflect Channel (1310nm)= Max.=0,5, Typical =0,3.dB Optical Input Return Loss: 45dB Operating Temperature: 0-65ºC ITU Standard Environmental Stability MDX21/MDX21/SA Dual channels CWDM MUX/DEMUX Typical Applications: Telecommunications LAN/Access /Metro Networks CWDM & DWDM Networks FTTx Transparency to data frame size, accomodating multiple protocols V-2

Remote MetroStar management via CWDM modules V-3

MDX81-E and MDDX81-E modules and related Stand-alone devices MUX/DEMU V-4 MDX81-E Specs more than 20 channels capacity 200 Gbps aggregate throughput Wavelength: (1471/1491/1511/ 1531/1551/1571/1591/1611nm) Duplex LC connectors Three slot module/stand-alone One Monitor Port Expansion channel: 1310±40nm Channel spacing= 20nm Channel Passband: (@0.5dB bandwidth) Wavelength Operation:ITU±6.5nm Max. Insertion Loss: : 3.0dB (MUX+DEMUX Pair only) 1530/1550nm: 2.3dB 1570nm: 3.0dB 1470-1610nm : 5.1dB Adjacent Channel Isolation (DEMUX): 30dB Optical Input Return Loss: 45dB Operating Temperature: 0~70 ºC ITU Standard Environmental Stability Passive optical products Typical Applications: Telecommunications LAN/Access/ /Metro Networks WDM medium/large networks FTTx Cellular Applications Transparency to data frame size, accomodating multiple protocols The modules may work in pair with another MDX81 module or stand-alone device MDX81/SA MDDX81-E Specs 8 CH DWDM MUX/DEMUX with Monitor and 1510nm Express channels Channel No: 8 - ITU channels (CH27-CH41) Channel Spacing: 0.8nm (100Ghz) Center Wavelength: CH27, CH29, CH31, CH33, CH35, CH37, CH39, CH41nm Passband@0.5dB: ITU+/-0.1nm Max.Insertion Loss/Max. Link Loss: 4.0/ 5.7dB Express In to Express- Out Loss: 2.0dB RX to Mon TX = 25 db (Mux) COM-D to Mon-RX 22 db (Demux) Adjacent Channel Isolation: 30 db (DEMUX) Non- Adjacent Channel Isolation: 35 db(demux) Optical Input Return Loss: 45 db Polarization Dependent Loss (PDL) 0.15dB Polarization Mode Dispersion: 0.1ps Max Optical Power: 300 mw Operating Temperature: 0 ~70 ºC Duplex LC/UPC connectors ITU Grid Standard Environmental Stability Passive optical products

Universal Topology V-5

4 CWDM channels MUX/DEMUX MDX41-3/MDX41-3/SA and MDX41-E/MDX41-E/SA MDX41-3 Specs 4 Channels Mux/Demux Wavelength:1270/1290/1310/1330nm Duplex LC connectors Dual slot module/stand-alone device Channel spacing= 20nm Max. Insertion Loss: : 1.6dB Max. Link Loss:2.5dB Adjacent Channel Isolation (DEMUX): 30dB Optical Input Return Loss: 45dB Operating Temperature: 0~70 ºC ITU Standard Environmental Stability Typical Applications: Telecommunications LAN/Access /Metro CWDM & DWDM medium/large networks FTTx Transparency to data frame size, accomodating multiple protocols The modules may work in pair with another MDX41 module or stand-alone device MDX41/SA V-6 MDX41-E Specs 5 Ch CWDM 1470,1510, 1550, 1590 MUX/DEMUX with 1310 Express and Monitor ports Passband@0.5dB: ITU+/-6.5nm Wavelength :1470/1510/1550/1590 and 1310nm Channel spacing= 20nm Max.Insertion Loss: 2.2dB Max. Link Loss: 3.5dB RX to Mon TX: 23,8 db ( MUX) Line RX to Mon RX 21,8 db ( DEMUX) Express In to Express Out: 2.0dB Adjacent Channel Isolation: Demux 30dB max Optical Input Return Loss: 45dB Operating Temperature: 0~70 ºC ITU Standard Environmental Stability

MDX41-E Basic connectivity V-7

MDX41-SFx modules and MDX41-SFx/SA Stand-Alone 4 Channels Single Fiber CWDM MUX/DEMUX 4 channels Single Fiber working CWDM Mux/Demux Wavelength: MDX41-SFA (1471/1491/1511/1531nm) MDX41-SFB (1551/1571/1591/1611nm) Simplex/Duplex LC connectors Dual slot module/stand-alone One Monitor Port Passband @0.5dB = ITU +/-6.5nm Channel spacing = 20nm Insertion Loss: 2.0dB 3.0dB Link Loss: 4.0dB Adjacent channel isolation: 35dB Optical Input Return Loss: 45dB Operating Temperature: 0 ~70 ºC ITU Standard Environmental Stability Typical Applications: Four systems transmission over one single fiber Telecommunications LAN/Access /Metro Networks CWDM & DWDM medium/large networks FTTx Transparency to data frame sizes, accomodating multiple protocols The module MDX41-SFA may work in pair with another MDX41-SFB module or standalone device MDX41-SFB/SA (similar for MDX41-SFB module) V-8

Four systems connectivity over one single fiber link V-9

FADMx/XX and FADMx/XX/SA Single wavelength single/dual channel CWDM Optical Add-Drop MUX/DEMUX (OADM) Single wavelength single/dual channel CWDM OADM FADM1/XX=Single WL=XX/Single chan. FADM2= Single WL/Dual channel Operating Wavelength: 1260-1620nm Duplex LC connectors with Backbone ports (West/East) Dual slot module/stand-alone device Passband @0.5dB = ITU +/-6.5nm Channel spacing= 20nm Insertion Loss (FADM1): 1.2dB Insertion Loss (FADM2): 1.6dB Adjacent channel isolation: 30dB Optical Input Return Loss: 45dB Operating Temperature: 0 ~70 ºC ITU Standard Environmental Stability Typical Applications: Telecommunications LAN/Access /Metro CWDM & DWDM medium/ large networks FTTx Transparent to data frame sizes, accomodating multiple protocols V-10

GE CWDM OADM PROTECTED NETWORK V-11

MDDX51-x and MDDX51-x/SA 5 ITU grid channels DWDM MUX/DEMUX 5 CH 100GHz DWDM MUX/DEMUX MDDX51-5/MDDX51-5/SA C-Band Channels:29/31/33/35/37 MDDX51-3/MDDX51-3SA C Band Channels:51/53/55/57/59 Duplex LC connectors Dual slot module/stand-alone device Passband @0.5dB = ITU +/-0.1nm Channel Spacing: 0.8nm Max. Insertion Loss: 2.4dB Max. Link Loss: 3.5dB Adjacent Channel Isolation (DEMUX): 30dB Optical Input Return Loss: 45dB Operating Temperature: 0 ~70 ºc ITU Standard Environmental Stability Typical Applications: Telecommunications LAN/Access /Metro CWDM & DWDM medium/ large networks FTTx Transparency to data frame sizes, accomodating multiple protocols The module may work in pair with another similar module or stand-alone device MDDX51-x/SA V-12

DWDM Topology 4x 10GE (MM,SM) 4x 10GE (MM,SM) MDDX51-5/SA V-13

MDDX41-SFx modules and MDDX41-SFx/SA Stand-Alone 4 DWDM Channel Single Fiber Multiplexer+Monitor V-14 Parameter Center Wavelength Unit nm Single Fiber Bidirectional Multiplexer ITU Channel (MUX:21,23,25,27) (DEMUX: 43,45,47,49) Channel Spacing nm 0.8 Channel Spacing GHz 100 Passband @0.5dB nm ITU+/-0.1nm Insertion loss: Add to COM COM to Drop COM to Mon Rx db 2.1 3.3 21.6 Adjacent Channel Isolation db 25 Non adjacent Channel Isolation db 35 Link Loss (Add to Drop) db 4.7 Optical Input Return Loss db 45 Polarization Dependent Loss db 0.15 Max. Optical Power mw 300 Operating Temperature ºC 0-70 Connector Type LC/UPC Highlights Four systems transmission over one single fiber Telecommunications LAN/Access/Metro Networks / FTTX CWDM/DWDM medium/large networks Transparency to data frames and multiple protocols The module MDDX41-SFA may work in pair with another MDDX41-SFB module or stand-alone device MDDX41-SFB/SA (similar working with MDDX41-SFB module)

Four systems transmission over one single fiber V-15

MDDX61-SFx modules and MDDX61-SFx/SA Stand-Alone 6 DWDM Channel Single Fiber Multiplexer+Monitor Parameter Unit Single Fiber Bidirectional Multiplexer Center Wavelength nm ITU Channel (MUX:21,23,25,27,29,31) (DEMUX: 45,47,49,51,53,55) Channel Spacing nm 0.8 Channel Spacing GHz 100 Passband @0.5dB nm ITU+/-0.1nm. Insertion loss Add to COM 2.7 COM to Drop COM to Mon RX db 4.5 21.6 Adjacent Channel Isolation db 25 Non adjacent Channel Isolation db 35 Link Loss (Add to Drop) db 6.0 Optical Input Return Loss db 45 Polarization Dependent Loss db 0.15 Max. Optical Power mw 300 Operating Temperature ºC 0-70 Connector Type LC/UPC V-16 Highlights Six systems transmission over one single fiber Telecommunications LAN/Access /Metro Networks/FTTX CWDM & DWDM medium/large networks Transparency to data frame sizes, accommodating multiple protocols The module MDDX61-SFA may work in pair with another MDDX61-SFB module or stand-alone device MDX61-SFB/SA (similar working with MDX61-SFB module)

Six systems transmission over one single fiber Management SWITCH Central Office Single Fiber MetroStar System MDDX61-SFA MCM1000X-RL Single Fiber Remote site A Falcon NTU Remote site B Falcon NTU Falcon NTU V-17

MDDX161-5/SA, MDDX321/SA, and MDDX401/SA Stand-Alone 16/32/40 DWDM Channel Multiplexer+Monitor port Parameter Specifications Unit Comments MIN TYP MAX Channel Spacing 100 GHz C - Band ITU band (PB) -12,5 +12.5 GHz Centered at each ITU channel frequency,fc Insertion Loss (ITU) 2.0. 3.5 db Maximum within ITU Band and PDL Insertion Loss (Passband) 3.0 4.5 db Maximum within ITU Band, and PDL Ripple 1.0 1,5 db Loss Variation within ITU Band Polarization Dependent Loss (PDL) 0.35 0.5 db Maximum within ITU Band Adjacent Channel Isolation (AX) 24 26 db Worst-case within ITU Band and Non adjacent Channel Isolation (NX) 30 40 db Worst-case within ITU Band and Return Loss (RL) 45 55 db Over All Channels and PDL Chromatic Dispersion (CD) -20 +20 ps/ nm Over ITU Band, guaranteed by design Polarization Mode Dispersion (PMD) 0.3 0.5 ps Over ITU Band, guaranteed by design Input Optical Power 250 m/w Operating Temperature -5 65 ºC Operating Relative Humidity 90 % Non-condensing Connector Type LC/UPC Specifications are for 32 and 40 DWDM Channels MDDX401/SA Stand-Alone unit Highlights 16/32/40 DWDM channels MUX/DEMUX Stand-alone devices Based on AVG Technology C Band ITU Grid channels (CH21-CH60) 10Gbs channel bandwidth The MDDX161-5/SA device includes 16 C Band ITU Grid channels (CH27-42) The devices MDDX321/401/SA have 32/40 C Band (21 to 60 ) Provide a cost effective solution in transferring 16/32./40 various signals (FE/GE/Fiber ChanneL/SONET/SDH/10GE) over DWDM channels Monitoring port for troubleshooting purposes 19 /1RU chassis enclosure P2P and Ring topologies applications V-18

Typical Solution: 16 and 40 ITU channels DWDM P2P configurations V-19

V-20 MCM1000X MCM1000X-RL MSM2500U MSM4000U MSM10G-U MetroStar modules using SFP/SFP+ transceivers Flexible Gigabit Ethernet conversion module for MetroStar with 2 SFP modular ports, each may accept any FibroLAN copper or fiber SFP transceiver, MA management Any to Any link protection Gigabit Ethernet conversion module for MetroStar with 4 SFP modular ports, each may accept any FibroLAN copper or fiber SFP transceiver, MA Universal Extender module, 100Mbps to 2.5Gbps, includes 2 SFP slots, use SFP transceiver (SFxG series) - (Only FibroLAN SFP transceivers can be used). Universal Extender module, 100Mbps to 4.0Gbps, includes 2 SFP slots, use SFP transceiver (SFxG series) - (Only FibroLAN SFP transceivers can be used). Multi-rate, Universal (protocol transparent) extender/transponder MetroStar module, 1000Mbps to 10Gbps, 2 SFP/ SFP+ slots CWDM Modules and Stand-Alone devices for Fast Ethernet MCM100-01LF3-C47-61 MCM100-01LF4-C41-61 MCM110-01SML-C41-61 MCM100-4E1/T1SMC4XX MCM100-4E1/T1SMC8XX H.CON/MA/SM/L C47-61 LTA41-4E1/T1/SMC4XX LTA41-4E1/T1/SMC8XX CWDM Single channel 100Base-TX to 100Base-FX, 1471/1611nm range Access/Conversion Module, 40km. 2*Duplex SC, MA CWDM Single channel 100Base-TX to 100Base-FX, 1471/1611nm range Access/Conversion Module, 80Km. 2*Duplex SC, MA CWDM Single channel 10/100Base-TX to 100Base-FX, 1471/1611nm range Access/Conversion Module, 40Km. 2*Duplex SC, MA Single Channel 100Base-TX to FX converter and four tunneled E1/T1, RJ48, SM CWDM, Wavelength=1xx1nm, 40km SC,MA Single Channel 100Base-TX to FX converter and four tunneled E1T1, RJ48, SM CWDM, Wavelength=1xx1nm, 80km SC, MA CWDM MA managed 10/100TX FX CONVETER/Access device, SC connectors,sm,40km, Wavelength=1xx1nm MA managed Multiple 10/100Base-TX to single 100Base-FX Local Traffic Aggregator with 4x RJ-45 10/100TX and four RJ-48 E1/T1 ports and simplex SC connector, CWDM - 40km,Wavelength= 1xx1 nm, MA MA managed Multiple 10/100Base-TX to single 100Base-FX Local Traffic Aggregator with 4x RJ-45 10/100TX and four RJ-48 E1/T1 ports and simplex SC connector, CWDM - 80km,Wavelength= 1xx1 nm, MA

CDWM/DWDM 1, 2.5, and 4.0 Gbps SFP Transceivers SF1G-LX5-5C-XX CWDM SFP 1.25Gbps F/O transceiver, dual LC connector, SM Wavelength=1xx1nm-DFB/APD, 100 km, Power Budget=32dB SF1G-LX6-5C-XX SF1G-LX7-5C-XX SF1G-LX4-5D-XX, SF1G-LX5-5D-XX, SF1G-LX6-5D-XX, SF2G-LX3-5C-XX CWDM SFP 1.25Gbps F/O transceiver, dual LC connector, SM Wavelength=1xx1nm-DFB/APD, 120 km, Pb=37dB CWDM SFP 1.25Gbps F/O transceiver, dual LC connector, SM Wavelength=1xx1nm-DFB/APD, 120Km, Pb=41dB DWDM SFP 1Gbps F/O transceiver, dual LC connector, ITU channel xx (29/31/33/35/37/51/53/55/57/59), DFB/APD, 80km, Pb=28dB DWDM SFP 1Gbps F/O transceiver, dual LC connector, ITU channel xx (29/31/33/35/37/51/53/55/57/59), DFB/APD, 100km, 31dB power budget DWDM SFP 1Gbps F/O transceiver, dual LC connector, ITU channel xx (29/31/33/35/37/51/53/55/57/59), DFB/APD, 120km, 36dB power budget CWDM SFP (Small Form Pluggable) 2.5Gbps F/O transceiver, dual LC connector, SM 1XX0nm/DFB, 40 km SF2G-LX4-5C-XX SF4G-LX3-5C-XX SF4G-LX4-5C-XX SF4G-LX4-5D-XX CWDM SFP 2.5Gbps F/O transceiver, dual LC connector, SM 1XX0nm-DFB/APD, 80 km CWDM SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, Wavelength=1xx1nm (47/49/51/53/55/57/59/61), DFB, 40 km CWDM SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, Wavelength=1xx1nm (47/49/51/53/55/57/59/61), DFB, 80 km DWDM SFP 1Gbps F/O transceiver, dual LC connector, ITU channel xx (29/31/33/35/37/51/53/55/57/59), DFB/APD, 120km, 36dB power budget V-21

V-22 SF1G-T SF1G-TX SF100-SMRF15 SF1G-S1 SF1G-LX1 SF1G-GMLX1 SF1G-LX2 SF1G-LX3 SF1G-LX4 SF1G-LX5 SF1G-SF13 SF1G-SF15 SF1G-SF13C SF1G-SF14C SF1G-LF13 SF1G-LF15 SF1G-ZF49 SF1G-ZF57 SF155-SMRF15 SF155-SMRF13 SF2G-S1 SF2G-S2 SF2G-LX2-3 SF2G-LX2-5 SF2G-LX3-3 SF2G-LX3-5 SF2G-LX4-5 SF2G-SF13 SF2G-SF15 SFP Transceivers 1Gbps and 2.5Gbps SFP (Small Form Pluggable) GBE STP transceiver, SERDES to 1000Base-T, shielded RJ-45, 100m over Cat.6 cable SFP GBE STP transceiver,10/100/1000baset, shielded RJ-45, 100m over Cat.6 cable (suitable for the Falcon series or any other product with SGMII based SFP ports) SFP 100Base-FX Single Fiber Strand F/O transceiver, SC connector, SM 1550nmTx/1310nmRx, 15 km SFP GBE F/O transceiver, dual LC connector, MM, 850nm, 220/550m SFP GBE F/O transceiver, dual LC connector, SM, 1310nm, 10km SFP 100BaseFX transceiver, (suitable for the Falcon series or any other product with SGMII based SFP ports) dual LC connector, SM, 1310nm, 10km SFP GBE F/O transceiver, dual LC connector, SM, 1310nm, 20km SFP GBE F/O transceiver, dual LC connector, SM, 1550nm/DFB, 40km SFP GBE F/O transceiver, dual LC connector, SM, 1550nm/DFB, 80km SFP GBE F/O transceiver, dual LC connector, SM, 1550nm-DFB/ APD, 120km SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM, 1310nmTx - 1550nmRx, 20km SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM, 1550nm-DFB Tx - 1310nmRx, 20km SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM 1310nmTx - 1490nmRx, 20km, color code - Blue SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM 1490nm-DFB Tx - 1310nmRx, 20km, color Code - Violet SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM, 1310nm DFB Tx - 1550nmRx, 40km SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM, 1550nm-DFB Tx - 1310nmRx, 40km SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM, 1490nm DFB Tx / 1570nmRx, 80km SFP Single Fiber Strand GBE F/O transceiver, LC connector, SM, 1570nm DFB Tx / 1490nmRx, 80km SFP OC3, Single Fiber Strand F/O transceiver, LC connector, SM, 1550nmTx/1310nmRx, 15 km SFP OC3 Single Fiber Strand F/O transceiver, LC connector, SM 1310nmTx/1550nmRx, 15km SFP (Small Form Pluggable) 2.125Gbps, F/O transceiver, dual LC connector, MM 850nm, 300/400m SFP 2.5Gbps, F/O transceiver, dual LC connector, SM 1310nm, 2 km SFP 2.5Gbps, F/O transceiver, dual LC connector, SM 1310nm DFB, 15 km SFP 2.5Gbps, F/O transceiver, dual LC connector, SM 1550nm DFB, 15 km SFP 2.5Gbps, F/O transceiver, dual LC connector, SM 1310nm DFB/APD, 40 km SFP 2.5Gbps,, F/O transceiver, dual LC connector, SM 1550nm DFB, 40 km SFP 2.5Gbps, F/O transceiver, dual LC connector, SM 1550nm DFB/APD, 80 km SFP Single Fiber Strand, 2.5G F/O transceiver, LC connector, SM, 1310nmTx - 1550nmRx, 20km SFP Single Fiber Strand, 2.5G F/O transceiver, LC connector, SM, 1550nm-DFB Tx - 1310nmRx, 20km

SFP Transceivers 4.0Gb SF4G-S1 SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, MM 850nm, 70/150m SF4G-LX1-3 SF4G-LX2-3 SF4G-LX3-3 SF4G-LX4-3 SF4G-LX4-5 SF4G-SF13 SF4G-SF15 SF4G-LF55 SF4G-LF49 SF4G-ZF55 SF4G-ZF49 SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, SM 1310nm, 5km SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, SM 1310nm, 10km SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, SM 1310nm, 30km SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, SM 1310nm, 40km SFP (Small Form Pluggable) 4Gbps F/O transceiver, dual LC connector, SM 1550nm,DFB 80km SFP (Small Form Pluggable) Single Fiber Strand 4 Gbps F/O transceiver, LC connector, SM 1310nmTx - 1550nmRx,DFB, 20km SFP (Small Form Pluggable) Single Fiber Strand 4 Gbps F/O transceiver, LC connector, SM 1550nmTx - 1310nmRx,DFB, 20km SFP (Small Form Pluggable) Single Fiber Strand 4 Gbps F/O transceiver, LC connector, SM 1550nmTx - 1490nmRx,DFB,40km SFP (Small Form Pluggable) Single Fiber Strand 4 Gbps F/O transceiver, LC connector, SM 1490nmTx - 1550nmRx,DFB,40km SFP (Small Form Pluggable) Single Fiber Strand 4 Gbps F/O transceiver, LC connector, SM 1550nmTx - 1490nmRx,DFB,APD 80km SFP (Small Form Pluggable) Single Fiber Strand 4 Gbps F/O transceiver, LC connector, SM 1490nmTx - 1550nmRx,DFB,APD, 80km V-23

V-24 FXFP-85 FXFP13-10 FXFP15-40 FXFP15-80 FXFP-40D-xx FXFP-80D-xx FXFP-40C-XX SFPP-85 SFPP-13-10 SFPP-15-40 SFPP-15-80 SFPP-S12-15 SFPP-S13-15 SFPP-S12-40 SFPP-S13-40 SFPP-C8-XX SFPP-C10-XX SFPP-C30-XX SFPP-C60-XX SFPP-D-40-xx SFPP-D-80-xx XFP Transceivers XFP transceiver for GA10,10GBASE-CX4, 15m over CX4 grade copper cable XFP transceiver for GA10, SM, Duplex LC, 1310nmDFB, 10km XFP transceiver for GA10, SM, Duplex LC, 1550nmEML, 40km XFP transceiver for GA10, SM, 1550nmEML/APD, 80km DWDM (xx=channel) XFP transceiver for GA10, 40km DWDM (Channel =xx) XFP transceiver for GA10, 80km CWDM (XX=47/49/51/53/55/57/59/61) XFP transceiver for GA10, EML, 40km SFP+ Transceivers SFP+ transceiver, multi-rate (1-10Gbps), MM, Duplex LC, 850nm, 300m SFP+ transceiver, multi-rate (1-10Gbps), SM, Duplex LC, 1310nm/DFB, 10km, 8dB power budget SFP+ transceiver, multi-rate (1-10Gbps), SM, Duplex LC, 1550nm/EML, 40km, 16dB power bu SFP+ transceiver, multi-rate (1-10Gbps), SM, Duplex LC, 1550nm/EML/APD, 80km, 23dB power budget SFP+ transceiver, multi-rate (1-10Gbps), SM, single fiber, Simplex LC, Tx:1270nm/Rx:1330nm/DFB, 15km, 9dB power budget SFP+ transceiver, multi-rate (1-10Gbps), SM, single fiber, Simplex LC, Tx:1330nm/Rx:1270nm/DFB, 15km, 9dB power budget SFP+ transceiver, multi-rate (1-10Gbps), SM, single fiber, Simplex LC, Tx:1270nm/Rx:1330nm/DFB, 40km, 16dB power budget SFP+ transceiver, multi-rate (1-10Gbps), SM, single fiber, Simplex LC, Tx:1330nm/Rx:1270nm/DFB, 40km, 16dB power budget SFP+ transceiver, multi-rate (1-10Gbps), CWDM, Duplex LC, 1xx0nm (1270-1330nm)/EML, 8km, 10dB power budget SFP+ transceiver, multi-rate (1-10Gbps), CWDM, Duplex LC, 1xx0nm (1470-1610nm)/EML, 10km, 10dB power budget SFP+ transceiver, multi-rate (1-10Gbps), CWDM, Duplex LC, 1xx0nm (1470-1610nm)/EML, 30km, 14dB power budget SFP+ transceiver, multi-rate (1-10Gbps), CWDM, Duplex LC, 1xx0nm (1470-1610nm)/EML/APD, 60km, 23dB power budget SFP+ transceiver, multi-rate (1-10Gbps), DWDM, Duplex LC, C-band/ITU channel xx/100ghz/eml, 40km, 14dB power budget SFP+ transceiver, multi-rate (1-10Gbps), DWDM, Duplex LC, C-band/ITU channel xx/100ghz/eml, 80km, 23dB power budget