ASHIDA Numerical OC/EF Protection Relay

Similar documents
ASHIDA Numerical 3OC + 1EF Protection Relay

Type: ADR233A (ADITYA V2 Series) (Preliminary) ASHIDA Numerical 3 Phase Tx. Differential Protection Relay

ASHIDA Numerical Directional 3OC + 1EF Protection Relay

Overcurrent Protection / 7SJ45

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

SIPROTEC 7SJ600 Numerical Overcurrent, Motor and Overload Protection Relay

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

1 INTRODUCTION ORDER CODE / INFORMATION

Application and Commissioning Manual for Numerical Over & Under Voltage Protection Relays Type MVT181 CONTENTS PAGE APPLICATION 2-7 INSTALLATION 8-16

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Digital Multifunction Instrument - Rish Master 3440

RS Pro ENGLISH. Datasheet

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Protective Relays Digitrip 3000

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

presentation contents application advantages

SIPROTEC 7SS60 Centralized Numerical Busbar Protection

Technical Data Sheet. x1000. kwh R Y B

RS Pro ENGLISH. Datasheet

AMIK 200 / 201 Technical Data Sheet

Data Sheet. RISH Master Record %THD

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

MULTI FUNCTION OVER CURRENT AND EARTH FAULT RELAY[50/51X3,50/51N]

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

ES-777-MV-P2_A1 03/01/10

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Protection and control VIP300. Technical manual

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

Theta 20A / 20V. Technical Data Sheet. Special Features

Technical Data Sheet AMIK 300 / 301

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

Time relay RXKA 1. (xx jpg) RXKA 1

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

Multimeter 500CVD21 RTU500 series

Advanced Test Equipment Rentals ATEC (2832)

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

Digital Motor Bus Transfer System M 4272

Kyongbo Electronics Co., Ltd.

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

AMIK Three Phase Digital Panel Meters

N. TEST TEST DESCRIPTION

SVERKER 900 Relay and Substation Test System

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Technical Data Sheet

05/09/2012

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Jewell DPM EINE BEST IN CLASS

Electronic timers CT-S range Selection and ordering details

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL

N. TEST TEST DESCRIPTION

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

SPECIFICATION. Online UPS 3000VA

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Power Meter Series PM3200 Functions and characteristics

REF 610 Feeder Protection Relay. Technical Reference Manual

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Utility Communications Teleprotection Equipment TPT-200

REB500 TESTING PROCEDURES

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

DOBLE F6150e TECHNICAL SPECIFICATIONS

Stabilized Differential Relay SPAD 346. Product Guide

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

XDC 6000 Watt and Watt Series Digital Programmable DC Power Supply. Operating Manual

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

ARC FLASH HAZARD ANALYSIS AND MITIGATION

SIPROTEC 7SD60 Numerical Pilot-Wire Current Differential Protection Relay

PROXIMITY SENSOR TERMINOLOGY

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

PQube 3 Specifications

Transcription:

ASHIDA Numerical OC/EF Protection Relay Features: 4 Element (3 Phase + EF) over current IDMT with instant trip. Back - lit LCD display for settings. Display of fault current. / Load current. Selection of Curve: Six selectable curves (Normal Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6). Separate curve selection for phase and EF. Design using DSP technology. Latching of fault current up-to up last 5 fault Password protection for setting. Site selectable CT secondary Relay can be made either IDMT or Define time Programmable operating time in instantaneous element Breaker Fail & Trip Circuit Supervision Function Programmable Annunciation Contact RS 232 (at front) and RS 485 (at rrear side) Communication Port for remote SCADA (only for i.e. communicable Relay) Relay). Communication protocol: Proprietary ASCADA in model AM101xx and IEC standard open protocol IEC60870-5-103 in model AM102xx (only for ). General: The ADR141A is member of Ashida Numerical Relay family ((Aditya Series)) design to meet demand of low and medium switchgear control. The ADR141A is a 3 OC and 1 EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring. The ADR141A continuously monitors all 3 phases and earth current, through CT connections. The high high-speed micro-controller samples this current through a 12-bit A/D converter.. The micro micro-controller performs powerful Digital Algorithms to find out Amplitude of current signal, and then this value is use for protection and metering function. All measurement is tuned to fundamental frequency. Each input current is also also displayed on 16 x 2 LCD display for metering. The Relay is having main three functions 1) Protection 2) Self Self-Supervision Supervision 3) Measurement The Relay can be supplied with different model. It can be either Definite Time or IDMT.

1. Protection Functions: The ADR141A give maximum benefit/cost ratio. The ADR141A give all the advantage of numerical relay at affordable cost. Following is summery of different protection functions provided by relay. ANSI IEC Protection Functions 50 I >> Instantaneous Over current Protection (OC-Inst.) 50N I E >> Instantaneous Earth Fault Protection (EF-Inst.) 50,51 I>t, Ip Time Over current Protection (Phase) (OC-IDMT.) 50N,51N I E >t, I EP Time Over current Protection (Earth) (EF-IDMT.) 1.1. Over current / EF protection: The ADR141A has 4 sensing element 3 OC and 1 EF. The tripping current can be set from 10% to 250% for phase and 10% to 250% for Earth fault in steps of 1% by Keys switch provided on front panel. The unit has got selection of IDMT characteristic of international IEC standard Very inverse / Extremely Inverse / Long Inverse and Standard inverse (both 3.0 sec and 1.3sec at 10 times). The unit also has Time Multiplier Setting (TMS) from x0.01 to x1.0 for IDMT delay multiplication. The instantaneous tripping function is having range of 50% - 3000% for phase and 50% - 3000% for EF and can be set in steps of 50%. The high speeds CPU continuously monitor the all four current inputs and compare with IDMT as well as instantaneous setting. If anyone current is above instantaneous setting the relay provides immediate trip command bypassing IDMT delay. If is input current is less than instantaneous setting but more than IDMT setting, CPU calculate IDMT delay as per selected IDMT characteristic multiply it with TMS setting and provide trip command if fault is persist even after this time delay. All the settings are password protected to prevent unauthorised change. 1.2. Extra Alarm Contact: Any Protection panel required extra contacts for provide visual ALARM and ANNUNCIATION indication for operator. Also some status contacts for SCADA or remote indications. Usually separate electromechanical relay used for contact multiplication of protection relay contacts. This added extra wiring and extra hardware. The ADR141A provide separate programmable ALARM contact for such application. Maximum 4 nos. of extra contacts can be provided. These contacts can be programmed as follows

ANN. TYPE 1 ANN. TYPE 2 ANN. TYPE 3 ANN. TYPE 4 RELAY 1 OC1 OC HF HF COM. ALARM RELAY 2 OC2 OC IDMT IDMT PROTH. RELAY 3 OC3 EF HF PHASE PHASE RELAY 4 EF EF IDMT EF EF 2. Supervision Function: 2.1 Self-supervision: The continuously keeping track on its internal hardware and the movement it detect any failure of any component, it give message on LCD display, This feature is very useful to give pre information to avoid any mall - operation. In such situation it use some default setting and remain in protection mode. 3. Measurement Function: In normal condition this display shows all settings. Via keyboard the display can be program to show the actual current flowing through the relay. If current excesses set value the relay gives trip command. The type of fault is displayed on LCD display. During the fault condition the relay measure the fault current and store in non-volatile memory. The fault current can be read via keyboard on LCD display Last 5 fault values along with tripping counter can be view via key-board. All settings are save in electrically erasable read only memory and remain. 4. Breaker Fail Function (BF or LBB) Normally after tripping current should be come Zero within 100 200ms time depend upon type of fault and breaker mechanism. After Fault Relay start one internal timer (settable from 0.05s to 0.8 s) If fault is not cleared during this time then relay declare as Breaker fail (LBB function) 5. Status : Status input S1 and S2 are general purpose for SCADA application and S3 and S4 are dedicated for CB NC and NO used for trip circuit supervision.

Ordering Information: The relay is available with nos. of different option. The option is specified by model no. It is user responsibility to specify correct model no. while ordering. While Ordering Specify the following Information for ADR141A Relay D e f i n i t i o n o f M o d e l N o o f A d i t y a S e r i e s o f R e l a y s A M X X X X X X X X X X Reserved for Future Use PT Secondary 0 CT Secondary 1 = 1 Amp. 2 = 5 Amp. 3 = 1 Amp. / 5 Amp. Selectable Auxiliary Supply 01 = 18 52 V dc 02 = 77 250 V dc 03 = 110 VAC 04 = 230 VAC 05 = 60 V dc 06 = 18-250 V dc AM XXX X X 101 ( with ASCADA Protocol for communication) 102 ( with IEC60870-5-103 Protocol for communication) Ordering information: 3OC + 1EF Relays 01 Relay with site selectable CTs, Trip circuit supervision CSA 150 3 and breaker fail function. 4 extra Ann. Contacts and 4 optically isolated status inputs ( 2nos for TSS ) 02 Relay with site selectable CTs in Draw out cabinet. CSA 150D 3 01 Relay with site selectable CTs, Trip circuit supervision CSA 150 3 and breaker fail function. 4 extra Ann. Contacts and 4 optically isolated status inputs ( 2nos for TSS ) 02 Relay with site selectable CTs in Draw out cabinet. CSA 150D 3 Note: communication protocols are only applicable for relay models. A D R 1 4 1 A - A M - X X X - X X - X - X - X X - X Example ADR141A AM-101-01-3-0-2-0 Back Terminal Layout: With 4 Programmable extra contacts, Selectable CT TSS Logic. Cabinet Type: CSA-150 non Drawout Auxiliary Supply: 77-250Vdc CT sec: 1/5 Amp.

Technical Specifications: Sr. No. Specification I. For Model AM101xx [ 3OC + 1EF relay ] Particulars Inputs : Suitable for CT secondary 1.0 Amp or 5.0 Amp. (Selectable) Protection Relay Setting Range Output contacts : Setting For phase 10% - 250 % For EF 10% - 250% : Operating Time Normal Inverse 1 (C1) Normal Inverse 2 (C2) Very Inverse (C3) Extremely Inverse (C4) Long Time Inverse (C5) Definite Tme (C6) 00(Inst) 99.9Sec : Inst. Setting For phase 50% - 3000%. or bypass In steps of 50% For EF 50% - 3000% or bypass In steps of 50% : Inst Operating Time Inst = < 30ms and additional adjustable software delay of 00 2.0Sec in steps of 10ms. : Model AM10101xxxxx & AM10201xxxxx 1) 2 NO Trip duty contact for Alarm and Trip 2) 4 NO ANN. Duty contacts ( Programmable) : Model NO Trip duty contact for Alarm and Trip AM10102xxxxx & AM10202xxxxx II. Pickup Current : Within 1.1 times of set current value. III. Resetting Current : 90% of set value. IV. Time Accuracy : Within class 5 As per IS: 3231. V. Burden on CTs : Less than 0.2VA. VI. Aux. Supply : 18 52VDC or 77 250VDC. To be specified while ordering. VII. Burden on Aux. Supply : Less than 10VA on any supply. VIII. Contact Rating Trip Duty : Make and carry for 3sec. 7500VA with max. 30A & 660VAC/DC IX. ON / Error : Make and carry for continuous 1250VA with max. 5A & 660VAC/DC : Break AC 1250 VA DC 100 W resistive 50W inductive. Operational Indicators (Flags) : Green LED indicates Relay OK : Red LED indicates Problem in relay Hardware.

PKP / HF : Green LED indicates relay Pickup. : Red LED indicates relay operated at HF. OC Fault / EF Fault TRIP / BF : Green LED indicates the relay tripped by OC, Hand Reset (HR) Type : Red LED indicates the relay tripped by EF, Hand Reset (HR) Type : Green LED Indicates that Trip pulse is being executed. SR type when TRIP contact selected as SR and HR type when TRIP contact selected as HR. When BYPASS P.B. is pressed, actual trip is not executed. : Red LED indicates BF operated. SR type when BF contact selected as SR and HR type when BF contact selected as HR. X. Thermal Withstand Capacity : x40 times the normal current for 3sec. : x2 Continuous XI. High Voltage Test : IEC 60255-5 XII. Impulse Voltage Test (all circuit class III) : Except DC Voltage 2.0 kv (RMS), 50Hz : Only DC voltage - 2.8 kv DC : Between Open contact of TRIP / CLOSE 1.5kV (RSM) 50Hz : Between Open contact of ALARM 1kV (RSM) 50Hz : IEC60255-5 : 5kV (peak) 1.2 / 50us, 0.5 J, 3 positive and 3 negative impulse at interval of 5 sec XIII. High Frequency test : IEC 60255-22-1, Class III : 2.5 kv (peak) 1MHz, τ = 15µs 400 surges / s duration 2 s XIV. Electro static Discharge : IEC 60255-22-2 Class III and IEC 61000-4-2 class III XV. XVI. Irradiation with radio frequency field, pulsemodulated, Fast transient interference/bursts : 4kV/6kV contact discharge, 8kV air discharge, both polarities 150pF, Ri 330 Ω : IEC 60255-22-3 and IEC 61000-4-2 class III : 10V/m; 80 to 1000MHz; 80%; 1kHz AM : IEC 60255-22-3 and IEC 61000-4-3, class III : 4kV; 5/50ns; 5kHz burst duration = 15ms; : Repetition rate 300ms; Both polarities; Ri = 50Ω; duration 1 min. XVII. Shock Test : IEC 60255-21-2 class 1 : Semi-Sinusoidal : 5g acceleration, duration 11ms, : Each 3 shocks in both direction of the 3 axes XVIII. Vibration Test : IEC 60255-21-1 class 1 / IEC 60068-2-6 : Sinusoidal 10 to 60Hz ±0.035 mm : Amplitude, 60 to 150Hz, 0.5g acceleration : Sweep rate 1 octave/min; 20 cycle in 3 orthogonal XIX. Seismic Test : IEC 60255-21-3

: In single axis sine sweep in X-axis sweep (@a sweep rate of 1 octave/minute) vibration in the frequency range (5-40 Hz) at amplitude of 3.5mm or 1.0gn (whichever is less) : In single axis sine sweep in Y-axis - weep (@a sweep rate of 1 octave/minute) vibration in the frequency range (5-40 Hz) at amplitude of 1.5mm or 0.5gn (whichever is less) XX. Bump Test : IEC 60255-21-2 Class-1 : 1000 bumps of 10gn peak acceleration and 16ms pulse duration in each of the two opposite direction per axis as per IEC60255-21-2 class 1 No. of axes. 3. XXI. Shock Withstand : IEC 60255-21-2 Clas-1 : 3 shocks of 15gn peak acceleration and 11ms pulse in each of two opposite direction. No. of axis : 3 XXII. Shock Response Test : IEC 60255-21-2 Clas-1 XXIII. XXIV. Vibration Endurance Test Environmental withstand (cold, Dry heat & steady state Damp Heat) : 3 shocks of 1gn peak acceleration and 11ms pulse in each of two opposite direction. No. of axis : 3 : IEC60255-21-1 20-sweeps (@ a sweep rate of 1octave / minutes) vibration in the frequency range (10-150Hz) at 1 gn (9,8m/s2) acceleration in each of the 3 mutually perpendicular axes : IEC60068-2 Cold 2 hours operational condition at (40 +/- 3) deg C as per IEC60068-2-1 Dry 2 Hours dry heat operational condition at(55+/2 2 deg. C as per IEC60068-2-2 Steady state damp heat - 2 hours steady sate damp heat operational condition at temperature at (55 +/- 2) deg. C & humidity 95% RH as per IEC60068-2-78 XXV. Drawing References : For Cabinet Type CSA -150 - MAC00101 : For Operating Characteristics : For Electrical Connection C1 C2 C3 C4 C5 3OC + 1EF AM10101 - APR02201 - APR01801 - APR05101 - APR05201 - APR05301 - APR06804_2 Datasheet Change Log for ADR141A

Issue No. (Revis ion) Date Description /Changes 01 28.08.09 Original Revision 02 01.11.09 Communicable Model added 03 01.12.09 Photograph of the relay Modified 04 09.12.09 Settings Changed