The LOGOMO Hall. Janne Riionheimo, Henrik Möller and Anssi Ruusuvuori Akukon Ltd, Hiomotie 19, Helsinki, Finland,

Similar documents
Room- and electro-acoustic design for a club size performance space

New ON/OFF Absorption Technology That Includes Low Frequencies

STUDIO ACUSTICUM A CONCERT HALL WITH VARIABLE VOLUME

ACOUSTICS IN THE MULTIPURPOSE HALLS OF THE NEW MAIN LIBRARY AND THE NEW MUNCH MUSEUM IN OSLO

On a new, variable broadband absorption product and acceptable tolerances of T30 in halls for amplified music

Volume (cu. Ft.) Total Abosrption 3340 Room Volume Reverbation Time 1.53

Room Acoustics. March 27th 2015

ACOUSTICAL COMPUTER SIMULATIONS OF THE ANCIENT ROMAN THEATRES

Design Project. Kresge Auditorium Lighting Studies and Acoustics. By Christopher Fematt Yuliya Bentcheva

Acoustics II: Kurt Heutschi recording technique. stereo recording. microphone positioning. surround sound recordings.

THE ACOUSTICS OF A MULTIPURPOSE CULTURAL HALL

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 TRANSPARENT CONCERT HALL ACOUSTICS

LOW FREQUENCY SOUND IN ROOMS

Acoustic solid angle criteria in practice: transforming the Chapelle Corneille in Rouen into a concert hall

THE ERATO PROJECT AND ITS CONTRIBUTION TO OUR UNDERSTANDING OF THE ACOUSTICS OF ANCIENT THEATRES

Proceedings of Meetings on Acoustics

The Effect of Television Decors on the Change of Reverberation Time of the Studio

installation in performance halls

Microphone a transducer that converts one type of energy (sound waves) into another corresponding form of energy (electric signal).

SIMULATION OF CERTAIN ACOUSTIC PROPERTIES OF THE "KNEŽEV DVOR" IN DUBROVNIK

Integrated Passive and Active Room Acoustics System design solution for a large worship space

Initial introduction of Scott Bauer and Scott Steiner ( the SoundScots)

REVERBERATION CHAMBER FOR EMI TESTING

Monitor Setup Guide The right monitors. The correct setup. Proper sound.

Measuring procedures for the environmental parameters: Acoustic comfort

RECENT EXPERIENCES WITH ELECTRONIC ACOUSTIC ENHANCEMENT IN CONCERT HALLS AND OPERA HOUSES

An Investigation on Factors That Cause Error in Reverberation Time Measurement (ISO 3382) in UTHM Lecturer Room

Elektroacoustic systems

Active Field Control (AFC) Reverberation Enhancement System Using Acoustical Feedback Control

Demystifying Project Studio Acoustics Version May 2004

15-06 Morlot Avenue, Fair Lawn, NJ USA Tel: (201) Fax: (201)

Sports Sound. Loudspeaker System Design Reference Guide

From time to time it is useful even for an expert to give a thought to the basics of sound reproduction. For instance, what the stereo is all about?

MDHS Science Department SPH 3U - Student Goal Tracking Sheet

Validation of lateral fraction results in room acoustic measurements

This section includes a detailed guide to what sound attenuation is and how to attain the optimum performance.

Advanced Acoustics SS1212 Silent Space Isolation Booth. Data Sheet

PNC France Paneling system High performance insulation and sound absorption for the practice and recording music at home.

INTRODUCTION. There are a myriad of different products on the market, these can essentially be broken down into two major categories of products:

, where I 0 is the. From the definition of intensity level, I I

AQ12. architectual. Compact, full-range system. features. applications. w w w w w

Audience noise in concert halls during musical performances

Case study for voice amplification in a highly absorptive conference room using negative absorption tuning by the YAMAHA Active Field Control system

Intext Exercise 1 Question 1: How does the sound produced by a vibrating object in a medium reach your ear?

Natural Sound Sound Reinforcement for the Royal Albert Hall with Mundorf ProAMT

Universitat Politècnica de València

One of the first things

A COMPARISION OF ACTIVE ACOUSTIC SYSTEMS FOR ARCHITECTURE

Application Guide. AcousticPerformance Series Loudspeakers

Genelec 1034B Control Room Monitoring System. Operating Manual

Modeling Diffraction of an Edge Between Surfaces with Different Materials

Suitable reverberation time for halls for rock and pop music

Absorbers & Diffusers

A Shell construction

Reflection and absorption of sound (Item No.: P )

R&D Center - Research and Development

Instrument Reflexion Filter

ROOM ACOUSTICS MEASUREMENT AND ASSESSMENT METHODS. 1. Signal to Noise OBJECTIVE METHODS ASSESSMENT OF ROOM ACOUSTICS CAN BE DIVIDED INTO:

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

What you Need: Exel Acoustic Set with XL2 Analyzer M4260 Measurement Microphone Minirator MR-PRO

Audiofrog UMI-1 Tuning CD Liner Notes

Experimental Investigation on the Effect of Origami Geometry on the Acoustic Characteristics

Technical Notes Volume 1, Number 25. Using HLA 4895 modules in arrays: system controller guidelines

Technical Note Vol. 1, No. 10 Use Of The 46120K, 4671 OK, And 4660 Systems in Fixed instaiiation Sound Reinforcement

Convention Paper Presented at the 122nd Convention 2007 May 5 8 Vienna, Austria

Three-dimensional sound field simulation using the immersive auditory display system Sound Cask for stage acoustics

SPORTS. Sound Solutions for Sports Venues. The Ultimate Fan Experience

W8C. touring and theatre. Compact three-way mid-high system

TIMBERIX WOODEN GROOVED PANEL

STUDIES OF EPIDAURUS WITH A HYBRID ROOM ACOUSTICS MODELLING METHOD

In situ assessment of the normal incidence sound absorption coefficient of asphalt mixtures with a new impedance tube

INTERNATIONAL CONGRESS CENTRE AND SPODEK ARENA. unique venues for unique events

not overpower the audience just below and in front of the array.

Determination of directional echograms and application in room acoustics

1037C and 1038B. Operating Manual Genelec 1037C and 1038B Tri-amplified Monitoring Systems

The Lindeman Hall of Oslo Evidence of lowfrequency radiation from the stage floor.

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

The Naim Balanced Mode Radiator The Naim Ovator Bass Driver

SIA Software Company, Inc.

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

ONLINE TUTORIALS. Log on using your username & password. (same as your ) Choose a category from menu. (ie: audio)

Advanced techniques for the determination of sound spatialization in Italian Opera Theatres

PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR. & Assembly. Installation Instructions

How to operate (folding)

Operation Manual. Dynavector SuperStereo Adapter DV SS Adp-3

SOUND. Second, the energy is transferred from the source in the form of a longitudinal sound wave.

Potting Store Assembly Instructions

ArrayCalc simulation software V8 ArrayProcessing feature, technical white paper

Playaway Swiss Cottage Assembly Instructions

EAW KF740 Technology Brief

Jurnal Teknologi THE ACOUSTIC EFFECTS OF THE AUDIENCE IN THE MODERN USE THE OF ANCIENT THEATRES. Full Paper. Gino Iannace *, Amelia Trematerra

VX 8.2. Product Description. Features. Applications

Sound Of Silence.

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 ACOUSTICAL MEASUREMENTS IN THE ANCIENT THEATRE OF SEGESTA

Proceedings of Meetings on Acoustics

Audio Engineering Society Convention Paper Presented at the 110th Convention 2001 May Amsterdam, The Netherlands

Add mass to the roll up door. This could even be leaning sheets of plywood and mattresses against it.

How To... Commission an Installed Sound Environment

Subject: Pappy s Grill and Sports Bar DJ System Acoustical Isolation Study

Transcription:

The LOGOMO Hall Janne Riionheimo, Henrik Möller and Anssi Ruusuvuori Akukon Ltd, Hiomotie 19, 00380 Helsinki, Finland, janne.riionheimo@akukon.fi The Logomo Hall is a new multi-purpose venue in Turku, Finland. It is built inside an engine shed concurrently with the renovation of the complex. The hall can be modified with a large movable tribune system riding on air casters into three different room configurations, seating up to 3500 people in its largest configuration. The hall is equipped with the Meyer Sound Constellation system, by which the perceived acoustical properties of the hall can be modified electronically. Natural acoustics of the hall are suitable for reinforced music. This paper will present the hall, describe the design process and present acoustic measurements from the hall. 1 Introduction The giant complex of Logomo is situated in Turku, the oldest city in Finland. Logomo is intended to be a new home for various cultural, creative and business events. Logomo is still under construction, but its centrepiece, the main hall, was opened in November 2011. By the end of 2014 there will be a further four performance arenas, studio areas, exhibition spaces, office spaces, a restaurant and workrooms for artists. The future performance spaces include a movie theatre, a black box theatre and two lecture halls. 2 Initial design The lack of a big venue for rock shows and theatre plays, visiting West End and Broadway musicals and shows with high quality sound production systems, was a driving force for the new multipurpose Logomo hall. From the beginning it was clear that the hall was to fulfil the requirements for various types of activities: - reinforced music (rock, pop, jazz, schlager ) - conferences - music theatre, musicals, revues - classical theatre - opera The starting point was that the acoustics of the hall should be appropriate for reinforced music. The aim was not to design a classical acoustic concert hall for which the dimensions of the hall (28x60m) wouldn t be appropriate. In terms of acoustics the desired versatility for the multipurpose hall would need massive variable acoustic structures or an excessive amount of curtains. However, the combination of an acoustic concert hall and a high quality hall for reinforced music would still be a compromise. It was decided that the variability in the sound field will be achieved by an electronic system. Within the timeline for the design Mayer Sound Constellation system was voted in. For the hall to be suitable for differently sized activities physical versatility should be acquired. The final decision was a massive movable seating stand that rides back and forth on compressed air cushions. The stand (called here the

tribune ) can be positioned in three different locations to form three configurations for the hall: small (S), medium (M) and large (L). Figure 1. Logomo hall in S-configuration Figure 2. Logomo hall in M-configuration Figure 3. Logomo hall in L-configuration The constellation system can be used in all three configurations. When the hall space shrinks the lobby area behind the tribune enlarges and forms a practical area for banquettes, exhibitions etc. The cloakroom has been lowered in the back of the tribune. The tribune itself has a sloped audience area for 1100 people in two levels. There are 360 fixed seats on the balcony and 800 fixed seats in the stalls. Seven first rows in the stalls (300 seats) can be folded under when the floor is intended for a standing audience. In addition there are 3 compartments, which can accommodate 150 sitting people.

2.1 Small In its smallest form the concert hall s area is 500m 2 while the lobby area behind the tribune is 2000m 2. Compact 1100- seat space provides an ideal venue for conferences or a chamber orchestra. 2.2 Medium In the medium configuration the hall seats up to 1700 people with removable chairs on the floor. The concert hall area is 900m 2 and lobby 1600m 2. This configuration is the main opera mode. 2.3 Large In its largest configuration the shape of the hall is an elongated rectangle accommodating 3500 standing people in a rock concert. The concert hall area is 1700m 2 (60 m x 28 m) and lobby 1000m 2. With the retractable audience area opened and with removable chairs on the floor the hall still seats 2160 people. 3 Initial acoustic planning After the classical concert hall was left out from the design, our work was more straightforward. Our goals in the acoustic design were: - Relatively short reverberation time between 0,9-1,5 s. During conversations with Mayer Sound designers we agreed that 1 second in M-configuration would be ideal for Constellation system. - Sufficiently strong lateral reflections, which is a prerequisite for a high quality listening environment for any music style. This is related to shaping of sidewalls. - Balanced sound field with high definition everywhere in the audience both during acoustic performances and reinforced concerts. - Enough reflections coming back to the stage with time intervals not too far from each other. These reflections support performers on the stage and mask possible individual slap echo from the tribune especially in L- configuration when the distance between the stage and the tribune is over 50 m. - Low background noise levels (environmental noise and HVCA noise) In rock concert halls an important factor is the clarity in the bass frequencies. In [1] it is noted that rock concert halls with a flat reverberation time profile across frequencies are rated higher that the halls with a longer reverberation in the bass, which is the normal requirement for classical acoustic concert hall. Additionally, the 63 Hz octave band has to be included in the acoustic design. However, a slight rise in the bass frequency reverberation would be beneficial for the Constellation system where the artificial reverberation is generated by amplifying and processing the normal acoustics of the hall. More amplifying power is needed for a hall with a declining bass reverberation. 3.1 Sound isolation A fundamental factor in acoustic design is sufficiently low background noise levels were critical. One problem was that the movable tribune had to be as lightweight as possible in order to be lifted up by the air casters. Also the six wide sliding doors with acoustic treatments attached on them had to be lightweight. The absolute tightness of the movable parts would be impossible to achieve. The solution was that the lobby, aisles and conference rooms around the hall provided a silent zone against environmental noise and against the noise from the other parts of the building. All the surrounding spaces are heavily absorbed. Another problem was that the HVCA machine room was positioned above the stage. Using proper isolators and suspended ceiling structures we could keep the HVCA noise below the limits. The hall s whole roof was to be rebuilt and replaced by lightweight wooden sandwich elements. Our concern was the sound isolation against environmental noise, particularly noise from the nearby railway yard. Because of the wide span (28 m) of the hall an additional suspended ceiling was not an option. The noise from the hall through the ceiling to the neighbouring apartment building was modelled with CADNA software, which gave the limits for the sound pressure

levels inside the halls. Fortunately the HVCA machine room forms a noise barrier between the hall s roof and the apartment building. 3.2 Acoustic treatments In the initial phase of the design the acoustics for the preliminary structures of walls and ceiling were calculated and predicted. A desire to leave the old structural concrete beams and pillars exposed was expressed, so the acoustic treatments were to be placed between and in flush with the pillars. Perforated board structures and diffusive surfaces were proposed for the walls and perforated boards for the ceiling. One of the problems was that the architectural concept changed during the project s timeline and the final structures were not decided until the end of the design phase so the model had to be updated throughout the project. The final concept for the sidewalls was partly perforated metal sheets. Perforated parts formed the architectural stripe concept that can also be seen in the sliding doors, where the stripes are reflective instead of being absorptive as in the sidewalls. The supply air is also circulated through the perforation. The cavity between metal sheets and sound isolation walls is filled with mineral wool for absorption. The same stripe concept is also the basis for the diffuser structures that occupy the three spaces between the pillars. The ceiling as well as the stage walls are clad with perforated MDFboards. A mostly absorptive rolling stand forms the rear wall for the hall. Reflections from the tribune s side and rear walls were still needed, the solution for which was a partly absorptive partly diffusive/reflective aluminium diamond structure. Figure 4. Sidewall "stripe" concept Figure 5. "Stripe" concept in a sliding door Figure 4. Sidewall diffuser structures Figure 5. "Diamond" diffusers in the tribune

4 Acoustic predictions The acoustics were planned and predicted using ODEON modelling software. The model was updated throughout the project and whenever some structural changes were to be made the acoustics were recomputed/recalculated. During the construction phase drywall layers were left out from the tribune due to the load limits and the entire roof was replaced with a more lightweight structure. Also the locations and areas of ventilation grills as well as ventilation cavities in the tribune were redesigned, which affected the percentage of perforation in the sidewalls. This consequently had a notable effect on the acoustics of the hall, so the amount of the required absorptive area kept changing. Figure 6. Hall in S-configuration Figure 7. Hall in L-configuration with removable chairs 5 Measurement results The final measurements were made in M and L configurations three months after the opening of the hall. Some details were still under construction and the final stage structure as well as stage curtains will not be installed until the summer of 2012. First seven rows of the retractable seating were under maintenance and folded away. Due to the talent show going on in the hall the shape of the stage and stage curtains weren t in their final arrangement but the hall itself was practically as in the model. The final measurements in figure 10 show that the reverberation time of the empty hall in M-configuration fulfils the design goal of 1 s in the middle frequencies. The decline of reverberation in the low frequency region was surprising as a flat or slightly rising reverberation time in the bass was anticipated. Presumably the reason for that was the lightened tribune structures and the safe estimation of low frequency absorption of the metal sheets. However, the bass accuracy in the dry hall has been praised so the only downside is the increased need for amplifying power in the Constellation system. Two parameters C80 and D50 in figure 11 and 12 show that the ratio of early to late sound energy is appropriate for reinforced music giving rhythmic punch, clarity and good intelligibility for performances.

Figure 8. Reverberation time in the unoccupied hall in L and M configurations Figure 9. Clarity in the unoccupied hall in L and M configurations. Clarity was measured with an omni source as well as with the PA system in L-configuration Figure 10. Definition D50 in the unoccupied hall in L and M configurations. D50 was measured with an omni source as well as with the PA system in L-configuration

6 Constellation As the natural reverberation time of the hall is between 0,9-1,3 seconds, the Constellation system is able to create an artificial reverberation field, where the acoustic properties can be modified electronically. For users the preprogrammed system is error proof, as the ipad-based interface is rather simple and the only modifiable acoustic parameters for the user are the reverberation time (1,0-2,5 sec), strength and warmth, albeit the scales are quite coarse. Figure 11. Constellation interface on ipad 7 Summary In general the reception of the hall has been very positive. Rock and pop sound engineers have been surprised with the definition of the hall, and the musicians have commended the sound on the stage. Music critics have given good ratings for classical concerts where the Constellation system has been in use. 8 Acknowledgement We would like to thank John Pellowe and his colleagues from Mayer Sound for productive co-operation as well as people from Logomo for fruitful teamwork as well as keeping high standards in acoustics. References [1] Niels Werner Adelman-Larsen, Eric R. Thompson, Anders C. Gade, Suitable reverberation times for halls for rock and pop music J. Acoust. Soc Am. 127 (1) January 2010.