Installation and User Guide. FlexIR TM NIR Fiber Optic Accessory

Similar documents
SPECTRONIC Standards User Guide

Flat Sample Holder Part Number

Development and Applications of a Sample Compartment FTIR Microscope

NIR SPECTROSCOPY Instruments

Installation and Operation Manual Document Number 000-specc

Planishing hammer stand For use with SKU Planishing hammer

SWS SWS62221 Spectral Sensor. General Description. Block Diagram

The Quest Single Reflection ATR Accessory User Manual

Heiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5

MOLECULAR SPECTROSCOPY UNIVERSAL ATR SAMPLING ACCESSORY

The FTNIR Myths... Misinformation or Truth

SMALL GAUGE NIBBLER ASSEMBLY & OPERATING INSTRUCTIONS Mission Oaks Blvd., Camarillo, CA Visit our Web Site at

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Spectrum 400. FT-IR and FT-NIR Spectrometer. There is only one answer.

MANUAL METAL SHRINKER/STRETCHER

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Heiland electronic GmbH TRD 2. B&W-Densitometer. User manual Version 6.4

Cold curing adhesive K-X280

Miniature Spectrometer Technical specifications

Getting Started. Spectra Acquisition Tutorial

ITEM Pipe Thread Kit (10 Piece Set - 7 Dies) Assembly and Operating Instructions

Ox-RAC-08 Ribbon Angled Fiber Cleaver User Manual

JAZ-ALP Adjustable Laser Pointer Operation Manual Document Number 013-RD

ASSEMBLY INSTRUCTIONS

Fiber Optic Tool Kit P/N IF-TK4

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

OxFAC-08 Angled Fiber Cleaver. User Manual. Issue 1.5

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Elcometer Muller Laboratory Grinder

Elo Touch Solutions Wallmounting Kit for the 7001L IDS Touchmonitors

Golden Gate Single Reflection Diamond ATR System User Manual

Fletcher F-3000 / F-3100 Accessory Laser Kit

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Copyright 2010 Springbok Publishing All Rights Reserved- Page 1

Guitar Mobile Storage Rack

Spotlight 150 and 200 FT-IR Microscopy Systems

Agilent 4500 Series FTIR. Operation Manual

Exploring the relationship between ergonomics and measurement quality in handheld FTIR spectrometers

FORTUS 360mc/400mc and FDM 360mc/400mc 3D Production System. Site Preparation Guide Rev E

Shrinker and stretcher

ZELPRINT LT300. USERS MANUAL June 2000

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

SPM-50 RF Spectrum Power Meter PC Software User Manual

PCI-HC10m User Guide

9 QUICK RELEASE WOODWORKING VISE

3M No Polish SC/APC Angle Splice Connector Jacket for 2 x 3 mm FRP and 1.6 to 3.0 mm Cable 8802-T/APC/AS/1.6-3

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

Material analysis by infrared mapping: A case study using a multilayer

INSTRUCTION MANUAL. Force Transducer Output Tube Repair Kit

Seized Drugs Operational Guidelines for the Thermo FTIR Comparative and Analytical Division

INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS

Guard Rail with In-Fill Panel

PLANISHING HAMMER STAND OWNER S MANUAL

Telephone: NICOLET ( ) or

Radiant Pro 2500 Video Light (Cat. No. 6047)

PT401 Paint Process Development and Infrared Reflectance Measurements

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

INSTRUCTION MANUAL INF Fax: (503)

KPS Turbidity Meter User s Manual

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

Instructions for Preparing OPTICAL GROUND WIRE IN AN ISOLATOR

Your Performance Partner

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

ASSEMBLY INSTRUCTIONS

OMEGA. Communications Interface Cabinet. Antenna Installation Manual

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

Owner s Manual & Safety Instructions

DAP Latex Window Glazing

GE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM

Application of 3M Pressure Sensitive Films to 3M Panagraphics Substrates

Quick Start MMRC Nicolet 6700 Revised 10/24/2018

FES PROPELLER MANUAL

Zoom Stereo Microscope NYMCS-360 Instruction Manual

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

SHRINKER/STRETCHER SET Create radius bends and contours in sheet metal

Stainless Steel Bench Stand

SlimScan BT Users Manual

Model BiConiLog Antenna. User Manual

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

IGPG Car Wash Round Robin Test Procedure

Nuclear Associates

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Mortising Attachment

Technical Information

Nuclear Associates

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Ensure Optimal Instrument Performance with Genuine Agilent Long-life Deuterium Lamps

SIMPLEX ELITE MAT CUTTER

SWIFT SERIES M2252DGL MICROSCOPE

Elementary Storage Cabinets

Tablet Arm for Wenger Playright Chairs

MKII Golden Gate Single Reflection ATR System User Manual. 2I Issue 13

2-wire level transmitter

Identify extraneous chemicals that contributed towards the failure of actuating mechanism in inner vial

EMI Shielded Windows & Contrast Enhancement Filters

OPERATING MANUAL. ACOUSTO OPTIC MODULATOR MODEL NUMBER: X-1.06-LTD X= 1, 2, or 3 mm DOCUMENT NUMBER: 51A14950A

Handheld Omnidirectional Laser Scanner

WEAR SAFETY GLASSES WHEN INSTALLING THIS KIT.

SPECIFICATIONS FOR 3M TM PRESTIGE SUN CONTROL WINDOW FILMS

Transcription:

Installation and User Guide FlexIR TM NIR Fiber Optic Accessory

The information in this publication is provided for reference only. All information contained in this publication is believed to be correct and complete. PIKE Technologies, Inc. shall not be liable for errors contained herein nor for incidental or consequential damages in connection with the furnishing, performance, or use of this material. All product specifications, as well as the information contained in this publication, are subject to change without notice. This publication may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of PIKE Technologies, Inc. nor the rights of others. PIKE Technologies, Inc. does not assume any liability arising out of any infringements of patents or other rights of third parties. This document contains confidential or proprietary information of PIKE Technologies, Inc. Neither this document nor the information herein is to be reproduced, distributed, used or disclosed, either in whole or in part, except as specifically authorized by PIKE Technologies, Inc. PIKE Technologies, Inc. makes no warranty of any kind with regard to this material including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Copyright 1991-2014 by PIKE Technologies, Inc., Madison, WI 53719. Printed in the United States of America. All world rights reserved. No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including but not limited to, photocopy, photograph, magnetic or other record, without the prior written permission of PIKE Technologies, Inc. Address Comments to: PIKE Technologies, Inc. 6125 Cottonwood Drive Madison, WI 53719 Phone (608) 274-2721 Fax (608) 274-0103 E-mail info@piketech.com Web Site www.piketech.com Jan. 1, 2014

Contents Introduction 1 Unpacking Your Accessory 2 Packing List 2 Installation 3 Accessory Adjustment 4 Performance Verification 5 Solid Sampling 6 Liquid Sampling 7 Precautions 7 Options 7

Introduction FlexIR Near-Infrared Fiber Optic accessory is a compact sample compartment-mounted accessory for measuring the composition of a wide variety of solid and paste materials. Using near-infrared chemometrics, qualitative product identification or quantitative analysis may be performed on pharmaceutical, nutraceutical, chemical, polymer, textile, food, agricultural or other samples. The FlexIR accessory features a high throughput, low-oh fiber optic probe with a reflectance tip and a high-speed, low-noise Indium-Gallium-Arsenide detector with optics and electronics interface. The FlexIR fits in the sample compartment of the FTIR spectrometer and connects to the detector port of the spectrometer. The window is bonded and sealed to protect the probe tip from corrosive materials and contamination. PN 350-0451000-00 Page 1

Unpacking Your Accessory In order for you to quickly verify receipt of your accessory, we have included a packing list. Please inspect the package carefully. Packing List User Manual PN 350-0451015 Quantity 1 FlexIR Optical and Electronic Interface Module PN 045-10XX Quantity 1 Fiber Optics and Cable Quantity 1 Probe Stand with Gold Reference Quantity 1 PN 350-0451000-00 Page 2

Installation Before installation, make sure the spectrometer is working in the near-infrared region without the FlexIR. Please consult the manufacturer of the FT-IR spectrometer regarding the conversion of the bench to near-infrared. This may involve replacing the beamsplitter and source to optimize for the 10,000 to 4000 cm -1 wavelength region of the IntegratIR. It is advisable to perform an alignment of the interferometer before inserting the IntegratIR into the sample compartment. Each FlexIR unit is manufactured to interface with a specific model FTIR spectrometer. Operation with a different model may require a factory conversion to be performed by PIKE Technologies. Place the Interface Module in the sample compartment of the spectrometer. The baseplate of the accessory assures the alignment of the accessory relative to the beam coming from the spectrometer. Connect the detector cable to the spectrometer. CAUTION: Make sure power to the spectrometer bench is off before plugging in the detector cable. Use the included cable to connect to the external port of the spectrometer and turn the spectrometer back on. Attach the two SMA connectors of the Fiber Optic Probe to the Interface Module. The FlexIR is ready for measurements. SMA Connectors Fiber Optic Probe Optical and Electronic Interface Probe Stand Figure 1. FlexIR NIR assembly PN 350-0451000-00 Page 3

Accessory Adjustment The accessory has been aligned and tested to ensure that it performs to specifications. No additional alignment is necessary. The gain of the FlexIR is set to allow the best signal-to-noise. Please check that the interferogram signal magnitude does not exceed the A/D converter required signal magnitude. This is done by placing the reflectance probe against the diffuse reference set into the bottom of the probe holder reference position (Figure 3). The interferogram signal can be reduced by using the aperture selection on the spectrometer. In the near-infrared high resolution is rarely used, thus the default aperture may be in the fully open position or any of the smaller apertures that do not significantly reduce the light level. Should a gain adjustment be necessary, which may be the case if switching between the diffuse probe tip and the liquid tip, the housing of the accessory can be removed and the gain adjusted using the potentiometer on the electronic board. This is typically a service function and PIKE Technologies should be contacted before attempting to do this adjustment. Fiber Optic Connections Detector Gain Adjust (Service Only) Figure 2. Interior view of FlexIR Electronic Interface Module PN 350-0451000-00 Page 4

Performance Verification With the accessory installed and the appropriate aperture set, insert the diffuse reflectance probe into the reference side of the probe stand to contact the diffuse gold reference (Figure 3). Source intensities, shape of the infrared beam, and the beam splitter characteristics vary from bench to bench. The single beam spectra may appear slightly different than shown in Figure 4. Using a 1 minute data collect time, collect a background followed immediately by a sample spectrum. The peak to peak noise around 6000 cm -1 should be equal to or less than 150 µabs RMS. Diffuse Gold Reference Position Figure 3. Probe stand with diffuse gold reference Figure 4. Single beam energy of the FlexIR (Red), ratio of two consecutive 1 min spectra of gold reference (Blue). Noise level around 6000 cm -1 should be less than 150 µabs RMS. PN 350-0451000-00 Page 5

Solid Sampling Sampling with the FlexIR is as easy as placing the probe on the sample. The probe is designed to be used with powders, plastics and other solid materials that have a flat part to contact the window on the probe. For solid samples, reproducible sample positioning has to be assured. The window at the tip of the probe is sealed using epoxy compound, thus it is relatively chemically inert and can be cleaned preferably with alcohol or with acetone for samples which are more difficult to clean. Samples for near-infrared need to be presented to the spectrometer in an optically uniform and reproducible fashion to obtain the same spectrum every time. Parameters that have significant effect on the samples are particle size and distribution, crystallinity, phase (for example, melted or solidified oils have very different spectra), compression, temperature (especially water-containing samples) and other physical or chemical differences. In all cases, the accessory is measuring the reflected light, thus transparent materials such as films produce very small signal. In certain cases, a reflective mirror can aid in returning the near-infrared light to the collecting part of the fiber. This double transmission (called transflectance) is a convenient way of measuring transparent or semi-transparent samples that have a reproducible thickness or pathlength. Figure 5. Sampling with the FlexIR through a thin plastic bag is possible due to the weak near-infrared signature of polyethylene. PN 350-0451000-00 Page 6

To collect a spectrum background, position the probe in the diffuse gold reference slot on the probe holder shown in Figure 3 prior to collecting the sample spectrum. Samples may be directly measured in a container using the probe. The contact between the sample and the probe should be maintained during the sample spectrum collection. Pressure on the sample should be maintained during the measurement and applied reproducibly to achieve repeatable results. Glass or plastic containers can also be used for samples, but the user must assure that the glass or plastic is uniform, reproducible and as thin as possible to position the sample surface as close to the probe tip as possible. Solids, pastes and powders can be measured. The near-infrared region is not as sensitive to residual water vapor as the mid-infrared. If the resolution is higher, the sharper water rotational-vibrational bands still are exhibited. Purging the sample compartment will also reduce this effect for increased spectral reproducibility in the water vapor regions. Liquid Sampling The Liquid Probe Tip is transflection tip used with the FlexIR Near-Infrared Fiber Optic Probe for liquid measurements. The tip is secured by threading it onto the probe end, after removal of the standard diffuse tip. To install the liquids tip, unscrew the diffuse tip first and transferring the O-ring seal between the probe body and the liquid tip. This O-ring seal is important to assure that chemicals cannot migrate into the inside of the probe. Prior to securing the liquids tip, make sure the O-ring is not damaged and that the tip is threaded on properly. Finger tightening is enough to assure proper seal. Tools are not necessary, nor recommended, to tighten the tip. Standard Tip Liquid Gap O-Ring Seal Use of Liquid Probe For measurements probe can be dipped in liquids. Please do not submerge too close to the handle, because there is no chemically-resistant seal around the handle. For background, it is best to use pure PN 350-0451000-00 Page 7

solvent. Otherwise, the dry cell can reflect the light differently from when the gap is filled with liquid. The small gap can be cleaned between samples with a stream of solvent (alcohol, acetone, etc.) squirted in the gap from the front and dried with a cloth or absorbent paper. Please note that water has higher surface tension and may not fill the gap just by dipping the probe due to the formation of an air bubble. To eliminate an air bubble from the gab, the probe can be held slanted with the front lip upward and the probe can also be swished in the liquid. Figure 1. Near-infrared transmission spectrum of biodiesel sample using the liquid tip. PN 350-0451000-00 Page 8

Liquid Tip Specifications Nominal Liquid Pathlengths Window Material Materials in Contact with Liquid 1.0 mm (two passes through 0.50 mm gap) 1.5 mm (two passes through 0.75 mm gap) 2.0 mm (two passes through 1.00 mm gap) Borosilicate glass Stainless steel, borosilicate glass, chemically resistant epoxy, Viton O-ring (Call PIKE Technologies to inquire about perfluoroelastomer O-ring) Precautions In order to provide the maximum signal in the infrared, with the minimum spectral interference, the mirrors in this accessory are thin film coated. Since the coatings are soft, care must be taken to avoid damage. Normally, these mirrors will not need cleaning since they are contained within the housing of the accessory. If they do need cleaning, they may be gently swept with a camel hair brush. Under no circumstances must the mirrors be rubbed with paper products such as Kleenex since this may scratch the mirror coating. Options Part Number Description 045-2001 Liquids Sampling Tip, 1.0 mm pathlength 045-2000 Liquids Sampling Tip, 1.5 mm pathlength 045-2002 Liquids Sampling Tip, 2.0 mm pathlength 045-2010 Diffuse Reflection Tip for FlexIR NIR Probe PN 350-0451000-00 Page 9

6125 Cottonwood Drive Madison, WI 53719-5120 (608) 274-2721 (TEL) (608) 274-0103 (FAX) info@piketech.com www.piketech.com