Process display RIA 261

Similar documents
Temperature transmitter with local display RIT 261

Temperature transmitter itemp RTD DIN rail TMT 127

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Level Limit Switch nivotester FTL 325 P

Radar Level Measurement micropilot FMR 130 for stilling wells

ph / ORP Measurement mypro CPM 431

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

itemp HART DIN rail TMT112

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature Transmitter itemp RTD DIN rail TMT 127

Advanced Paperless Recorder eco-graph a

Memosens New technology for contactless, inductive, digital transmission of ph signals

Temperature head transmitter itemp TC TMT 188

Soliphant T FTM20, FTM21

Model 264IB. ABB 2600T Series Engineered solutions for all applications

Temperature head transmitter itemp PCP TMT 181

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

0 2 1 â Ó. itemp HART TMT182. Technical Information

Field indicator for current loops with HART communication Models DIH50, DIH52

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Technical Information Barrier RB223

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

Loop Powered Indicator

Level Measurement Continuous level measurement Radar transmitters

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

2-Wire Toroidal Conductivity Transmitters Series APT2000 Specifications

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

itemp PA TMT184 Technical information

MEAS CAL ALARM CONF APT2000 TC

Condumax W CLS15 and CLS15D

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

0 2 1 â Ó. itemp HART TMT182. Technical Information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Conductivity measurement SmarTec S CLD 132

Orbipac CPF81/CPF82 and CPF81D/CPF82D

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Rosemount 3101, 3102, and 3105

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Wireless Base Radio. Wireless Transmitters

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Temperature Transmitters TMT 136, TMT 137

Technical Information itemp TMT180

Level Measurement Continuous level measurement Radar transmitters

Two-Wire Programmable Transmitter for:

Dissolved Oxygen Measurement liquisys M COM 223 F / 253 F

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Coriolis Massflowmeter

Fisher 646 Electro-Pneumatic Transducers

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Temperature head transmitter itemp PCP TMT 181

Field indicator for current loops with HART communication Models DIH50, DIH52

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Pressure transmitter AKS 32 and AKS 33

SALES SERVICE +358 (0)

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

PAD - Heavy Duty Differential Pressure Trasmitter

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol

Areas of application Head transmitters Field transmitters Your benefits

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Coriolis Massflowmeter

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Positioner with HART Communication Type 3780

Resistance thermometer Model TR30, compact design

TIY Programmable, Isolated Thermocouple Transmitter combines

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Fisher 646 Electro Pneumatic Transducer

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Field IT 2600T Series Pressure Transmitters

Paperless Recorder PR20

Level Limit Switch nivotester FTL 370, FTL 372

DATASHEET F090 - GENERAL PURPOSE INDICATOR

Areas of application Head transmitters Field transmitters Your benefits

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Technical Information Condumax CLS21D/CLS21

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Installation guide 877 FDI Field Display & Interface

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Temperature Measurement

SITRANS T measuring instruments for temperature

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Transcription:

Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable required 5 digit LC display, 1 inch (26 mm) character height Trend bargraph in 10% increments Rear illumination without additional power supply Measurement range displayed from -19999 to 99999 Flexible measurement range set up using 3 pushbuttons inside enclosure Certification: - FM - CSA - ATEX Two cable entries for wiring the measurement circuit Interior space for installing additional measurement electronics, e.g. temperature transmitters Housing can be lead sealed to protect against unauthorized entry Application Areas Plant and machine construction Field mounted applications Laboratory fittings Process display, monitoring Suitable for intrinsically safe applications The Power of Know How

Operation and system construction Measurement principle Field display application area The display measures an analog measurement signal and indicates this on the display. The display is connected in a 4 to 20 ma current loop and also derives the required power from the loop. The measurement influence of the voltage drop of < 2 V is almost negligible. The dynamic internal resistance (load) assures that the maximum voltage drop is never exceeded independently from the current loop. The analog signal at the input is digitized, analyzed and shown on the rear illuminated display. Measurement system Micro-controlled field mounted display with illuminated LC display. Setting up the measurement range, decimal place, and offset is done easily on an open unit using the three operational push buttons. Setting up during operation is also possible. The display rear illumination is always active and requires no further wiring for its energy requirement. Input Values Input type Measurement range Electrical specification Current 4 to 20 ma (polarity protected) Voltage drop (load), < 2 V Maximum input current (short circuit current), 150 ma Output Output signal Fault signal Transmission 2 The analog input signal (4 to 20 ma) is not converted. The input signal is digitized, analyzed and shown on the LC display. Loss of measured value display, no rear illumination The indicator allows transmission of the HART transmission protocol

Power supply Electrical connection Non hazardous area Terminals 2 and 4 linked internally 1 2 3 4 Y I - - Hazardous area Non hazardous area Y I - Terminals 2 and 4 linked internally 1 2 3 4 - - Intrinsically safe loop power supply Field mounted display terminal layout Terminal Input and Outputs 1 Measurement signal () 4 to 20 ma Signal input 2 Connection terminal for further instrumentation Terminal 3 Measurement signal (-) 4 to 20 ma Signal input 4 Connection terminal for further instrumentation Terminal Power supply Cable entry The power supply is provided using the 4 to 20 ma current loop power. Voltage drop, < 2 V Two 1/2 NPT cable entries, optional two PG 11 (M20) cable entries Accuracy Reference conditions Measurement deviation Influence of ambient temperature T = 77 F (25 C) < 0.1% of scaled analog range Temperature drift = 0.01%/K ambient temperature Application conditions (installation) Installation hints Installation area, wall or pipe mounting (refer to accessories) Installation angle, no limitations Application conditions (environment) Ambient temperature range Storage temperature range Ingress protection 0 to 140 F (-20 to 60 C); for hazardous areas, refer to hazardous certificate -15 to 160 F (-25 to 70 C) NEMA 4X (IP 66) 3

EMC immunity RF protection to EN 55011, Group 1, Class B Interference safety: ESD to IEC 1000-4-2, 6 kv / 8 kv Electromagnetic fields to IEC 1000-4-3, 10 V/m Burst (power supply) to IEC 1000-4-4, 4 kv Surge to IEC 1000-4-5, 1 kv Cable high frequency to IEC 1000-4-6, 10 V Mechanical construction Dimensions 6.89" (175) 2.56" (65) 3.15" (80) 4.21" (107) 1.57" (40) 6.42" (163) 2.05" (52) E - Enter push button (E) Selection push buttons (, -) Dimensions in inches (mm) There is room available behind the hinged electronics for additional electronics, e.g. temperature head transmitter. Take note of manufacturers installation instructions! Internal dimensions: H = 2.4 (60 mm), W = 5.5 (140 mm), D = 1.2 (30 mm) Housing can be lead sealed to prevent unauthorized entry. GORE-TEX filter is used as pressure compensation, fitted on the left of the conduit entries. Weight Materials Wire terminals 4 < 1 lb (approximately 0.80 kg) Housing, die cast aluminum, epoxy coated with glass insert Wall/stand pipe mounting kit and tension strip, 304 SS. Plug on screw terminals, terminal size 16 AWG (1.5 mm 2 ) for solid core and 18 AWG (1.0 mm 2 ) for stranded with ferrule. Earth ground connection (on the housing exterior), 14 AWG (2.5 mm 2 ).

Display and operating elements Display elements Display 5-digit LCD, 1 (26 mm) character height, rear illuminated. Bargraph display in 10% increments, markers for over / under range display. Display range -19999 to 99999 Offset -19999 to 32767 Operation 3 push button operation (- / / E) integrated in the unit, access when unit is opened Signals measurement range over / under value Rear illumination illumination brightness increases with an increase in loop current. Certificates and approvals CE mark Approvals By attaching the CE mark, confirms that the instrument fulfills all the requirements of the relevant EC directives (89/336/EWG). FM approved intrinsically safe Class I, Division 1, Group A, B, C, D CSA approved intrinsically safe Class I, Division 1, Group A, B, C, D ATEX II 1 G EEx ia IIC T6 Details regarding the availability of the intrinsically safe versions (FM, CSA, ATEX, etc.) can be obtained from. Relevant data for application protection can be found in separate documentation, available upon request. 5

Accessories Wall / pipe mounting kit Wall and / or pipe mounting kit, 304 SS with tension strap for pipe mounting. Order Number: SONDST-AA B 2.99" (76) 1.57" (40) A 5.51" (140) 6.77" (172) (B) Wall / pipe mounting kit (dimensions in inches (mm) Supplemental documentation Process display, RIA 261 operating manual BA 111R/09/a3 Ex documentation for FM, CSA, ATEX, etc. XA 007R/09/a3 6

Ordering information RIA 261 process display 1-channel, scale adjustable for connection to 4 to 20 ma current loop circuit, LC display with 5-digits, 1 (26 mm) character height, bargraph with 10% resolution, over/under range, operation using three push buttons, access on opened unit. RIA 261-1 2 3 1 Certification A Version for non-hazardous areas B ATEX II 1 G EEx ia IIC T6 C FM IS, Class 1, Div. 1, Grps. A, B, C, D D CSA Ex ia, Class 1, Div. 1, Grps. A, B, C, D 2 Model 1 Field housing with PG 11 conduit entries 2 Field housing with 1/2 NPT conduit entries 3 Additional features K Without accessories, North American region L Wall / pipe mounting kit, North American region 3 Factory calibration certificate 4 Factory calibration certificate and mounting kit 7

For application and selection assistance, in the U.S. call 888-ENDRESS For total support of your installed base, 24 hours a day, in the U.S. call 800-642-8737 Visit us on our web site, www.us.endress.com United States, Inc. 2350 Endress Place Greenwood, IN 46143 Tel. 317-535-7138 Sales 888-ENDRESS Service 800-642-8737 Fax 317-535-8498 inquiry@us.endress.com www.us.endress.com Canada Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Tel. 905-681-9292 800-668-3199 Fax 905-681-9444 www.ca.endress.com Mexico Paseo del Pedregal No. 610 Col. Jardines del Pedregal 01900, Mexico D.F. MEXICO Tel. 525-568-2405 Fax 525-568-7459 The Power of Know How TI 083R/24/ae/08.04 2004, Inc.