AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S PANEL PROFILE AR-PJ-07-DW2H DW-2000R PANEL PROFILE AR-PJ-08-DW2H DW-2000R 2" HORIZONTAL PANEL JOINT AR-PJ-09-DW2H DW-2000R 2" VERTICAL PANEL JOINT AR-PJ-10-DW2H DW-2000R 3" HORIZONTAL PANEL JOINT AR-PJ-11-DW2H DW-2000R 3" VERTICAL PANEL JOINT AR-PJ-12-DW2H DW-2000R PANEL INTEGRATION AR-PJ-13-DW2H DW-2000H TO DW-2000V TRANSITION AR-PJ-14-DW2H VERTICAL JOINT W/ EXTRUSION AR-PJ-15-DW2H CUSTOM W/ 4" ACCENT EXTRUSION AR-PJ-16-DW2H RADIUS PANEL JOINT AR-PJ-17-DW2H BLOCK SPLINE VERTICAL JOINT AR-PJ-18-DW2H 3" TO 2" PANEL INTEGRATION AR-PJ-19-DW2H 2" TO 3" PANEL INTEGRATION AR-PJ-20-DW2H PANELS OVER STRUCTURAL STEEL AR-PJ-21-DW2H PANELS OVER METAL STUDS AR-PJ-22-DW2H PANELS OVER CONCRETE AR-BS-01-DW2H BASE DETAIL - FLUSH AR-BS-02-DW2H BASE DETAIL - OVERHANG AR-BS-03-DW2H BASE DETAIL AT VERTICAL JOINT (FLUSH) AR-BS-04-DW2H BASE DETAIL AT VERTICAL JNT. (OVERHANG) AR-OC-01-DW2H TRANSVERSE BENT CORNER AR-OC-02-DW2H 45 TRIMLESS END AR-OC-03-DW2H FULL WRAP END AR-OC-04-DW2H OUTSIDE CORNER WITH EXTRUSION AR-OC-05-DW2H OUTSIDE CORNER WITH FLAT TRIM AR-IC-01-DW2H INSIDE CORNER WITH EXTRUSION AR-IC-02-DW2H INSIDE CORNER WITH TRIMLESS ENDS AR-IC-03-DW2H INSIDE CORNER WITH FLUSH TRIM INDEX SHEET 1
AR-FO-01-DW2H AR-FO-02-DW2H AR-FO-03-DW2H AR-FO-04-DW2H AR-FO-05-DW2H AR-FO-06-DW2H AR-FO-07-DW2H AR-FO-08-DW2H AR-FO-09-DW2H AR-FO-10-DW2H AR-FO-11-DW2H AR-SF-01-DW2H AR-SF-02-DW2H AR-PR-01-DW2H AR-PR-02-DW2H AR-PR-03-DW2H AR-TL-01-DW2H AR-TL-02-DW2H AR-TL-03-DW2H AR-TL-04-DW2H AR-TL-05-DW2H AR-TL-06-DW2H AR-TL-07-DW2H AR-TL-08-DW2H AR-TL-09-DW2H AR-TL-10-DW2H AR-TL-11-DW2H AR-TL-12-DW2H INTEGRATED LOUVER HEAD INTEGRATED LOUVER SILL INTEGRATED LOUVER JAMB F.O. TWO PIECE HEAD F.O. HEAD WITH DRIP EDGE F.O. TWO PIECE JAMB F.O. ONE PIECE JAMB F.O. ONE PIECE SILL F.O. HEADER WITH EXTRUSION F.O. JAMB WITH EXTRUSION F.O. SILL WITH EXTRUSION WALL TO SOFFIT LONGITUDINAL BENT SOFFIT INTEGRATED PARAPET COPING PARAPET W/ FLUSH TRIM PARAPET W/ FLUSH EXTRUSION WALL PENETRATION WALL PENETRATION SECTION 2" EXTRUSIONS 3" EXTRUSIONS EXTRUSION LAP STRIPS TRIM END LAP TRIM LAP WITH HEM MENDING PLATE "SHINGLE" LAP TRIM END LAP WITH LAP STRIP TRIM AT FRAMED OPENINGS EXTRUSION AT FRAMED OPENING ACCESSORIES INDEX SHEET 2
DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS EXTRUSION SHAPES / ENGAGEMENT MAY VARY FROM THOSE SHOWN. PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION PURPOSES ONLY. ARCHITECTURAL DISCLAIMER
DIRECTION OF INSTALLATION 24", 30" OR 36" MODULE FACE OF PANEL 1 2 " REVEAL STANDARD INTERLOCK JOINT FINNED GASKET 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP VERTICAL SUPPORTS BY OTHERS 2" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 2" HORIZONTAL PANEL JOINT
6" RECOMMENDED BEARING FRAMING BY OTHERS CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2" 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 1 2 " VERTICAL JOINT GASKET PANEL LENGTH MEASURED FROM HERE PANEL LENGTH MEASURED FROM HERE 2" VERTICAL PANEL JOINT
DIRECTION OF INSTALLATION 24", 30" OR 36" MODULE FACE OF PANEL 1 2 " REVEAL STANDARD INTERLOCK JOINT FINNED GASKET 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP VERTICAL SUPPORTS BY OTHERS 3" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 3" HORIZONTAL PANEL JOINT
6" RECOMMENDED BEARING FRAMING BY OTHERS CONTINUOUS MENDING PLATE FILL VOID WITH COMPRESSIBLE FOAM CLOSURE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 3" 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 1 2 " VERTICAL JOINT GASKET PANEL LENGHT MEASURED FROM HERE PANEL LENGTH MEASURED FROM HERE 3" VERTICAL PANEL JOINT
PANEL MODULE FACE OF PANEL 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 13 16 " VERTICAL SUPPORT BY OTHERS 6" MAX. REVEAL MODIFICATION BUILT INTO LOWER PANEL 2" OR 3" FASTENING CLIP NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED AT TERMINATIONS CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS CUSTOM REVEAL
DW-2000S - HORIZONTAL INSTALLATION STANDARD INTERLOCK JOINT FINNED GASKET FACE OF PANEL 24", 30", OR 36" MODULE STANDARD 1 1 4" STRIATION PITCH REVEAL STRIATED FACE SHEET STRIATION DEPTH.035 INCH DW-2000S PANEL PROFILE
DW-2000R - HORIZONTAL INSTALLATION STANDARD INTERLOCK JOINT FINNED GASKET STANDARD INTERLOCK JOINT FINNED GASKET 12", 16", 20", AND 24" MODULE AVAILABLE 4" RIB SPACING 12", 16", 20", AND 24" MODULE AVAILABLE 4" RIB SPACING 2" NOM. 3" NOM. DW-2000R PANEL PROFILE
DW-2000R - HORIZONTAL INSTALLATION 2" FACE OF PANEL 12", 16", 20", OR 24" MODULE STANDARD INTERLOCK JOINT FINNED GASKET 7 8 " DIRECTION OF INSTALLATION 4" RIB SPACING 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP VERTICAL SUPPORTS BY OTHERS FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS DW-2000R 2" HORIZONTAL PANEL JOINT
DW 2000R - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FRAMING BY OTHERS CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2" 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER VERTICAL JOINT GASKET PANEL LENGTH MEASURED FROM HERE 1 2 " FACTORY END CAP STAMPED TO MATCH RIBBED PROFILE PANEL LENGTH MEASURED FROM HERE DW-2000R 2" VERTICAL PANEL JOINT
DW-2000R - HORIZONTAL INSTALLATION 3" FACE OF PANEL 12", 16", 20", OR 24" MODULE 7 8 " STANDARD INTERLOCK JOINT FINNED GASKET DIRECTION OF INSTALLATION 4" RIB SPACING 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP VERTICAL SUPPORTS BY OTHERS FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS DW-2000R 3" HORIZONTAL PANEL JOINT
DW 2000R - HORIZONTAL INSTALLATION 6" RECOMMENDED BEARING FRAMING BY OTHERS CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 3" 2 - PC FASTENING CLIP WITH 1 4"-14 THROUGH FASTENER WITHOUT WASHER VERTICAL JOINT GASKET 1 2 " FACTORY END CAP STAMPED TO MATCH RIBBED PROFILE PANEL LENGTH MEASURED FROM HERE PANEL LENGTH MEASURED FROM HERE DW-2000R 3" VERTICAL PANEL JOINT
DW-2000R - HORIZONTAL INSTALLATION DESIGNWALL 2000H PANEL VERTICAL SUPPORTS BY OTHERS 12" MODULE SHOWN 4" RIB SPACING DESIGNWALL 2000R WALL PANEL 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER DESIGNWALL 2000H PANEL 2 - PC FASTENING CLIP DW-2000R PANEL INTEGRATION
6" RECOMMENDED BEARING FRAMING BY OTHERS CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER MODIFIED EDGE ON VERTICAL PANEL 2" OR 3" DESIGNWALL 2000H PANEL DESIGNWALL 2000V PANEL VERTICAL JOINT GASKET 1 2 " HORIZONTAL PANEL LENGTH MEASURED HERE VERTICAL PANEL LENGTH MEASURED HERE DW-2000H TO DW-2000V TRANSITION
6" RECOMMENDED BEARING 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 16 GAUGE MENDING PLATE FRAMING BY OTHERS CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2" OR 3" BLACK EPDM GASKET 7 3 4 " 7 8 " 8 " 2 1 2" ALUMINUM JOINT EXTRUSION ALTERNATIVES PLUG ENDS OF HORIZ. JOINTS WITH SILICONE SEALANT* PVC FOAM GASKET ALUMINUM TOP HAT JOINT EXTRUSION ALUMINUM FLUSH INSERT ALUMINUM RECESSED INSERT *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED AT TERMINATIONS VERTICAL JOINT W/ EXTRUSION
PANEL MODULE VERTICAL SUPPORTS BY OTHERS 1 4 " - 14 HEX HEAD FASTENERS WITH WASHER PANEL MODULE 4" 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER SILICONE SEALANT 4" ACCENT EXTRUSION 2" PANEL ONLY *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED AT TERMINATIONS CUSTOM W/ 4" ACCENT EXTRUSION
PLAN VIEW RADIUS PER PROJECT REQUIREMENTS 24" MINIMUM PAN EDGES ON FACINGS W/ SEALANT MOCK INTERLOCK JOINT EXTRUSIONS STRETCH-FORMED TO RADIUS SOLID BACKER WITH NO KERF CUTS PANELS CURVED "HARD WAY" - CURVED JOINT RADIUS PANEL JOINT
8" BEARING REQUIRED FRAMING BY OTHERS REAR SEAL BUTYL 2 1 2" CONTINUOUS MENDING PLATE BLOCK SPLINE ISO CORE PANEL CONTINUOUS HEIGHT (20 FT. MAX.) 2" OR 3" LINE OF HORIZ. REVEAL 1 2 " 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER FIELD APPLIED SILICONE PANEL LENGHT MEASURED FROM HERE PANEL LENGTH MEASURED FROM HERE BLOCK SPLINE VERTICAL JOINT
3" DIRECTION OF INSTALLATION 24", 30" OR 36" MODULE FACE OF PANEL 1 2 " REVEAL STANDARD INTERLOCK JOINT FINNED GASKET 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP MODIFIED EDGE CONDITION AT 3" PANEL VERTICAL SUPPORTS BY OTHERS 2" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 3" TO 2" PANEL INTEGRATION
2" DIRECTION OF INSTALLATION 24", 30" OR 36" MODULE FACE OF PANEL MODIFIED EDGE CONDITION AT 3" PANEL 1 2 " REVEAL STANDARD INTERLOCK JOINT FINNED GASKET 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP VERTICAL SUPPORTS BY OTHERS 3" FASTENING CLIP CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS 2" TO 3" PANEL INTEGRATION
ALWAYS ATTACH HORIZONTAL PANELS TO VERTICALLY ORIENTED SUPPORTS VERTICAL TUBES VERTICAL TUBES HORIZONTAL PANELS PANELS OVER STRUCTURAL STEEL
ALWAYS ATTACH HORIZONTAL PANELS TO VERTICALLY ORIENTED SUPPORTS VERTICAL STUDS HORIZONTAL PANELS SHEATHING OPTIONAL PANELS OVER METAL STUDS
ALWAYS ATTACH HORIZONTAL PANELS TO VERTICALLY ORIENTED SUPPORTS VERTICAL SUBGIRTS HORIZONTAL PANELS PRECAST OR CMU WALL PANELS OVER CONCRETE
2" OR 3" CONTINUOUS BUTYL SEALANT 1 4 "-14 "LOW PROFILE" FASTENERS CONCEALED BASE EXTRUSION FIELD DRILL 3 8" Ø WEEP HOLES BED SEAL TO CONCRETE FABRICATED BASE TRIM BASE DETAIL - FLUSH
2" OR 3" CONCEALED BASE EXTRUSION CONTINUOUS BUTYL SEALANT 1 4 "-14 "LOW PROFILE" FASTENER FIELD DRILL 3 8" Ø WEEP HOLES BASE DETAIL - OVERHANG
6" REC. VERTICAL JOINT GASKET (SHOWN) OR FIELD APPLIED BACKER ROD AND SEALANT CONTINUOUS MENDING PLATE BUTYL SEALANT CONTINUOUS BEADS "SHINGLE" LAP MENDING PLATE OVER FLASHING. SEE AR-TL-08-DW2H FLASHING BEHIND AND UNDER BASE EXTRUSION BASE EXTRUSION W/ BUTYL SEALANT BELOW STOP EXTRUSION SHORT OF PANEL EDGE MARRIAGE BEAD TO JOINT SEALANT SEALANT BASE DETAIL AT VERTICAL JOINT (FLUSH)
5" REC. VERTICAL JOINT GASKET (SHOWN) OR FIELD APPLIED BACKER ROD AND SEALANT CONTINUOUS MENDING PLATE BUTYL SEALANT CONTINUOUS BEADS FLASHING BEHIND BASE EXTRUSION W/ BUTYL SEALANT BELOW STOP EXTRUSION SHORT OF PANEL EDGE MARRIAGE BEAD TO JOINT SEALANT SEALANT BASE DETAIL AT VERTICAL JOINT (OVERHANG)
FRAMING BY OTHERS CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER FACTORY TRANSVERSE BEND SHORT LEG 4'-0 MAXIMUM, TOTAL LENGTH 14'-0 MAX. TRANSVERSE BENT CORNER
FRAMING BY OTHERS CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT PANEL LENGTH 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 3 8 " VERTICAL JOINT GASKET 3 8 " 1 2 " PANEL LENGTH 45 TRIMLESS END
FRAMING BY OTHERS CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 1 2 " VERTICAL JOINT GASKET FULL WRAP END FULL WRAP END
2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2" OR 3" FIELD CUT PANELS TO SUIT PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* 2-PC ARROWHEAD OUTSIDE CORNER EXTRUSION CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 3" 3" OPTIONAL WIPER GASKET (FIELD INSTALLED) *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED OUTSIDE CORNER WITH EXTRUSION
INSIDE CORNER TRIM 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2" OR 3" VERTICAL SUPPORT PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT POP RIVETS OUTSIDE CORNER TRIM F.I.P. INSULATION AS REQUIRED (BY OTHERS) FIELD MITER PANELS *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED OUTSIDE CORNER WITH FLAT TRIM
OPTIONAL WIPER GASKET (FIELD INSTALLED) 1 4 " - 14 "LOW PROFILE" FASTENER FIELD CUT PANELS TO SUIT CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT VERTICAL SUPPORT 2-PC ARROWHEAD OUTSIDE CORNER EXTRUSION 2" OR 3" PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER INSIDE CORNER WITH EXTRUSION
CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FRAMING BY OTHERS CONTINUOUS MENDING PLATE PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* 1 2 " 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER VERTICAL JOINT GASKET *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED INSIDE CORNER W/ TRIMLESS ENDS
F.I.P. INSULATION AS REQUIRED (BY OTHERS) OUTSIDE CORNER TRIM VERTICAL SUPPORT 2 - PC FASTENING CLIP WITH 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 2" OR 3" CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT INSIDE CORNER TRIM POP RIVETS PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* *NOTE: FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED INSIDE CORNER WITH FLUSH TRIM
CONTINUOUS BUTYL SEALANT STARTER CLIPS W/ 1 4"-14 HEX HEAD FASTENER WITH WASHER PANEL GASKET 1 2 " LOUVER FRAME 7 8 " BIRD SCREEN DESIGN LOUVER BY BENCHMARK INTEGRATED LOUVER HEAD
DESIGN LOUVER BY BENCHMARK BIRD SCREEN 1 2 " 1 7 8" LOUVER FRAME CONTINUOUS BUTYL SEALANT INTEGRATED LOUVER SILL
RECESSED 2.5" FLANGE AT LOUVER JAMB CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 2 - PC FASTENING CLIP WITH 1 4"-14 FASTENER WITHOUT WASHER VERTICAL JOINT GASKET DESIGN LOUVER BY BENCHMARK PANEL LENGTH MEASURED FROM HERE 1 2 " LOUVER FRAME INTEGRATED LOUVER JAMB
CONTINUOUS BUTYL SEALANT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER POP RIVETS EXTERIOR CAP TRIM INTERIOR CAP TRIM CONTINUOUS BUTYL SEALANT FRAMED OPENING FIELD DRILL 3 8" Ø WEEP HOLES FIELD CUT FEMALE JOINTS WHERE REQUIRED DOOR/WINDOW FRAME EXPOSED SEALANT NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. TWO PIECE HEAD
CONTINUOUS BUTYL SEALANT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS POP RIVETS EXTERIOR CAP TRIM CONTINUOUS BUTYL SEALANT FRAMED OPENING DRIP FLASHING FIELD CUT FEMALE JOINTS WHERE REQUIRED DOOR/WINDOW FRAME EXPOSED SEALANT NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. HEAD WITH DRIP EDGE
FRAMED OPENING DOOR/WINDOW FRAME CONTINUOUS BUTYL SEALANT 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER INTERIOR CAP TRIM EXPOSED SEALANT POP RIVETS FIELD CUT PANELS WHERE REQUIRED EXTERIOR CAP TRIM PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* FASTENING CLIP CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT POP RIVETS NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS 3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED F.O. TWO PIECE JAMB
FRAMED OPENING DOOR/WINDOW FRAME 1 4 " - 14 "LOW PROFILE" FASTENERS (AS REQUIRED) CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER CONTINUOUS BUTYL SEALANT EXPOSED SEALANT FIELD CUT PANELS WHERE REQUIRED CAP TRIM 2 - PC FASTENING CLIP POP RIVETS PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS 3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED F.O. ONE PIECE JAMB
CONTINUOUS BUTYL SEALANT EXPOSED SEALANT CONTINUOUS BUTYL SEALANT WINDOW FRAME FIELD CUT MALE JOINTS WHERE REQUIRED EXTERIOR CAP TRIM POP RIVETS 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS FIELD BEND (AS REQUIRED) 1 4 " - 14 "LOW PROFILE" FASTENERS (AS REQUIRED) FRAMED OPENING NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. ONE PIECE SILL
2" OR 3" CONTINUOUS BUTYL SEALANT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS TWO PIECE HEAD EXTRUSION CAP 1 4 " - 14 "LOW PROFILE" FASTENERS CONTINUOUS BUTYL SEALANT FRAMED OPENING FIELD DRILL 3 8" Ø WEEP HOLES FIELD CUT FEMALE JOINTS WHERE REQUIRED TWO PIECE HEAD EXTRUSION BASE DOOR/WINDOW FRAME EXPOSED SEALANT OPTIONAL WIPER GASKET (FIELD INSTALLED) NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. HEADER WITH EXTRUSION
DOOR/WINDOW FRAME FRAMED OPENING OPTIONAL WIPER GASKET (FIELD INSTALLED) EXPOSED SEALANT CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT TWO PIECE JAMB EXTRUSION BASE FIELD CUT PANELS WHERE REQUIRED TWO PIECE JAMB EXTRUSION CAP 2" OR 3" 2 - PC FASTENING CLIP WITH 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER PLUG ENDS OF HORIZONTAL JOINTS WITH SILICONE SEALANT* NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS 3) FOR REVEALS GREATER THAN 1/2" METAL CLOSURES MAY BE REQUIRED F.O. JAMB WITH EXTRUSION
OPTIONAL WIPER GASKET (FIELD INSTALLED) CONTINUOUS BUTYL SEALANT EXPOSED SEALANT DOOR/WINDOW FRAME SILL EXTRUSION FIELD CUT MALE JOINTS WHERE REQUIRED 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS CONTINUOUS BUTYL SEALANT 1 4 " - 14 "LOW PROFILE" FASTENERS FRAMED OPENING 2" OR 3" NOTE: 1) SEE DETAIL AR-TL-07-DW2H, AR-TL-08-DW2H, AND AR-TL-10-DW2H FOR TYPICAL TRIM LAP INSTRUCTIONS 2) SEE FLUSHGLAZE 4500 & FLUSHGLAZE 7500 DETAILS FOR INTEGRATED WINDOW DESIGNS F.O. SILL WITH EXTRUSION
2" ONLY PANCAKE FASTENER "LOW PROFILE" CONTINUOUS BUTYL SEALANT 1 4 " - 14 HEX HEAD FASTENERS WITH WASHER STARTER CLIPS CONCEALED SOFFIT EXTRUSION FIELD DRILL 3 8"Ø WEEP HOLES 1 2 " CONTINUOUS BUTYL SEALANT WALL TO SOFFIT
1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 2 - PC FASTENING CLIP VERTICAL SUPPORT FABLOK FASTENER OR TEK SCREW AT GIRTS FACTORY LONGITUDINAL BEND SUM OF BOTH LEGS NOT TO EXCEED STANDARD PANEL WIDTH NOTE: VERIFY WIND LOADS WITH KINGSPAN PRIOR TO USING EXPANSION FASTENERS FOR PANEL ATTACHMENT LONGITUDINAL BENT SOFFIT
INTEGRATED PARAPET COPING EXTRUSION SILICONE TUBE SEALANT TYP. STITCH TEKS TO TIE FLASHING IN PLACE FABRICATED METAL FLASHING EXTENSION STAINLESS STEEL SCREW PAINTED TO MATCH PANEL. 12" O.C. 3 4 " 3" 1 5 8" POP RIVETS 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER CONTINUOUS BUTYL SEALANT 2 - PC FASTENING CLIP SILICONE SEALANT 2" OR 3" INTEGRATED PARAPET COPING
FIELD CUT MALE JOINTS WHERE REQUIRED WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE PARAPET CAP FLASHING 1 4 " - 14 "LOW PROFILE" FASTENER PARAPET BLOCKING CONTINUOUS BUTYL SEALANT FASTENER TO PARAPET BACKER CONTINUOUS CLEAT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER MEMBRANE ROOF & PARAPET BACKER PARAPET W/ FLUSH TRIM
PARAPET EXTRUSION 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS CONTINUOUS BUTYL SEALANT FIELD CUT MALE JOINTS WHERE REQUIRED WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE CONTINUOUS BUTYL SEALANT 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS FASTENER TO PARAPET BACKER PARAPET CAP TRIM 1 4 " - 14 "LOW PROFILE" THROUGH FASTENERS MEMBRANE ROOF & PARAPET BACKER OPTIONAL WIPER GASKET (FIELD INSTALLED) PARAPET W/ FLUSH EXTRUSION
KINGSPAN TO SUPPLY FLATSTOCK TO BE FIELD BENT AND BROKE FOR PANEL CLOSURE ATTACH FLATSTOCK WITH POP RIVETS HORIZONTAL PANEL JOINT SILICONE SEALANT AT PERIMETER OF BEAM F.I.P. INSULATION SET FLATSTOCK IN BUTYL SEALANT FIELD NOTCH PANELS STEEL FRAMING POP RIVET FLATSTOCK TO ANGLE ANGLE ATTACHED TO STEEL FRAMING SILICONE SEALANT AT PERIMETER OF BEAM FIELD CUT FLATSTOCK WALL PENETRATION
'A' TRIM BACKER ROD AND SEALANT PENETRATION 'A' ELEVATION POP RIVET SEALANT BACKER ROD AND SEALANT FASTENER (AS REQUIRED) FLASHING SEALANT PENETRATION SECTION 'A-A' NOTES: 1. DO NOT ALIGN PENETRATIONS AT PANEL JOINT LOCATIONS. 2. FLASHING AT PENETRATIONS TO BE FIELD FABRICATED FROM FLATSTOCK SHEETS AS NECESSARY WALL PENETRATION SECTION
TWO PIECE OPENING EXTRUSION CAP DIE #13943 2" TWO PIECE OPENING EXTRUSION BASE DIE #13939 PARAPET EXTRUSION DIE # 13938 SILL EXTRUSION DIE #13937 2" PANEL 4" REVEAL EXTRUSION DIE #54271 2" PANEL CONCEALED BASE EXTRUSION DIE #14560 2" CORNER EXTRUSION BASE DIE #14102 2" PANEL CONCEALED SOFFIT EXTRUSION DIE #14270 2" PANEL PARAPET COPING DIE #11536 CORNER EXTRUSION CAP DIE #14008 VERTICAL JOINT EXTRUSIONS TOP HAT EXTRUSION DIE #13950-A FLUSH INSERT DIE #13951 RECESSED TOP HAT EXTRUSION DIE #13949-A RECESSED INSERT DIE #14101 2" EXTRUSIONS
TWO PIECE OPENING EXTRUSION CAP DIE #13943 3" TWO PIECE OPENING EXTRUSION BASE DIE #13941 PARAPET EXTRUSION DIE # 13938 SILL EXTRUSION DIE #13937 3" PANEL CONCEALED BASE EXTRUSION DIE # 14559 3" CORNER EXTRUSION BASE DIE #14104 3" PANEL PARAPET COPING DIE #11943 CORNER EXTRUSION CAP DIE #14008 VERTICAL JOINT EXTRUSIONS TOP HAT EXTRUSION DIE #13950-A FLUSH INSERT DIE #13951 RECESSED TOP HAT EXTRUSION DIE #13949-A RECESSED INSERT DIE #14101 3" EXTRUSIONS
LAP STRIP FOR TWO PIECE JAMB EXTRUSION LAP STRIP FOR PARAPET EXTRUSION LAP STRIPS FOR OUTSIDE CORNER EXTRUSION LAP STRIPS FOR INSIDE CORNER EXTRUSION LAP STRIP FOR SILL EXTRUSION LAP STRIP FOR VERTICAL HAT EXTRUSION EXTRUSION LAP STRIPS
(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM LAP WITH HEM
(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MENDING PLATE "SHINGLE" LAP
(2) BEADS BUTYL SEALANT 8" LONG LAP STRIP NOM. 1 4" GAP TRIM END LAP WITH LAP STRIP
FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM AT FRAMED OPENINGS
FIELD CUT/NOTCH JAMB EXTRUSION AT HEAD AND JAMB SEALANT END DAM TWO PIECE HEAD EXTRUSION CAP 3 EXPOSED SEALANT EXPOSED SEALANT TWO PIECE HEAD EXTRUSION 2 TWO PIECE HEAD EXTRUSION BASE W/ FIELD DRILL 3 8" Ø WEEP HOLES TWO PIECE JAMB EXTRUSION BASE 1 6 TWO PIECE JAMB EXTRUSION 4 TWO PIECE JAMB EXTRUSION CAP FIELD CUT/NOTCH JAMB EXTRUSION SILL EXTRUSION 5 TWO PIECE JAMB EXTRUSION CAP EXTRUSION INSTALLATION SEQUENCE: 1 TWO PIECE JAMB EXTRUSION BASE 2 TWO PIECE HEAD EXTRUSION BASE 3 TWO PIECE HEAD EXTRUSION CAP 4 TWO PIECE JAMB EXTRUSION CAP 5 SILL EXTRUSION 6 EXTERIOR SEALANTS AS REQUIRED EXTRUSION AT FRAMED OPENING
2 - PC FASTENING CLIPS FASTENING CLIP 2" (2 - PC) FASTENING CLIP TOP PART # 8100.4102 BOTTOM PART # 8100.4101 FASTENING CLIP 3" (2 - PC) FASTENING CLIP TOP PART # 8100.5102 BOTTOM PART # 8100.4101 HB-1 STARTER CLIP PART # 8100.1000 VJ-1 2" OR 3" FLAT PANEL 3" RIBBED PANEL VJ-2 2" RIBBED PANEL VERTICAL JOINT GASKET GASKET AVAILABLE IN BLACK OR LIGHT GRAY ACCESSORIES