AC axial compact fan

Similar documents
AC diagonal compact fan

AC axial compact fan

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. forward curved, single inlet with housing (flange)

onlinecomponents.com

AC axial compact fan

AC centrifugal fan. backward curved

AC axial compact fan

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC axial fan. sickled blades (S series)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

AC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

EC centrifugal fan - RadiCal

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan - RadiCal

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

DC axial compact fan

Tangential Fans - Basic principles. Expertise, performance, innovation

EC/AC axial fans - HyBlade Ø

Product Data Sheet 3252J/2H3PU

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 6424/2HP-210

Product Data Sheet 3254 J/2H3P

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet RER190-39/14/2TDMO

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet RER225-63/18/2TDO- 406

Product Data Sheet 8452/2 GHHP

Product Data Sheet 6314/2TDHP. The engineer's choice

Soğutmada büyük beden modası

Tangential blowers with multiple housings. Optimized air flow steady distribution.

Product Data Sheet 622/2HHP-021

Product Data Sheet DV4112/2NP-201

Product Data Sheet 8214 J/2H4P

Automotive BL-DC Fans for Commercial Vehicles. Edition

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Cooling Fans G-17. Cooling Fans G-17. AC Input/Low-Power Consumption EMU Series. AC Input/Compact Size MU Series

ACS600, ACS800. Installation Guide

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Lexium integrated drives

SPECIFICATION FOR APPROVAL

Subject to changes 11/2003 Page 1/7

Han High Temp. Description. Design overview. Han High Temp connectors remain robust and reliable for their entire lifespan!

Explosion proof rotary actuator - On/Off or programmable regulating actuator

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Specification For Approval

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Safety switches with slotted hole lever

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

KFS. Flap-type flow meter. Design and range of application

C B. Models. Models 2MOPP

56 mm sq. (2.20 inch sq.)

Online data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS

847H. Description. Features. Specifications

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

PARTNER ALTERNATORS LSA 40-4 Pole

Technical guide. EC300 motor V8

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

Electrical height adjustment. ... easy & reliable. Multilift II telescope Multilift II. Synchron

60 mm sq. (2.36 inch sq.)

Measuring current transformers of the W, W series

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

System protection by Vibration monitoring

EN 50178, IEC

OT FIT 15/ /500 LT2 LP

MINI-PS AC/24DC/1.3

Safety Relay Unit. OFF-delay time

PSR Interactive Guides. Additional Information. Products Low Voltage Products and Systems Control Products Softstarters Softstarters

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Digital flow transmitter for continuous flow measurement

Transcription:

WE-HK8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 59 Nominal data Type Motor WE-HK8- ME68-BF Phase ~ ~ Nominal voltage VAC Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min - 55 8 Power input W 6 8 Current draw A.9.5 Motor capacitor µf.5.5 Capacitor voltage VDB 5 5 Capacitor standard P (CE) P (CE) Max. back pressure Pa 8 95 Min. ambient temperature C -5-5 Max. ambient temperature C 6 65 Starting current A.55.5 ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations Item no. 76-5-998 Revision 87 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE-HK8- Technical features Mass Size Surface of rotor Material of blades Material of wall ring Number of blades 7 Direction of air flow Direction of rotation Type of protection Insulation class Humidity class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 699 (measuring network Fig., TN system) Electrical leads Motor protection Cable exit Protection class Product conforming to standard Approval. kg mm Coated in black Sheet steel, coated in black Die-cast aluminium "V" Counter-clockwise, seen on rotor IP ; Depending on installation and position "B" F + 8 C - C Any None S Ball bearing <.75 ma Via terminal strips, integrated capacitor connected via terminal strips Thermal overload protector (TOP) wired internally Variable I (if protective earth is connected by customer) EN 65-; CE CCC; EAC; UL ; VDE; CSA C. Nr. Item no. 76-5-998 Revision 87 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE-HK8- Product drawing Direction of air flow "V" Connection screen U blue Z brown U black PE green/yellow Item no. 76-5-998 Revision 87 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE-HK8- Charts: Air flow 5 Hz Druck p f s[pa]für Rho=,kg/m^ 5 5 qv[cfm] 5 5 5 5 55,8 9,75 8 7 6 5 9 8 7 6,7,65,6,55,5,5,,5 pfs_e[in HO],,5 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 7 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 5,,5,,5 5 5 5 5 5 5 qv[m^/h] 55 6 65 7 75 8 85 9 95 Measured values U V f Hz 5 5 5 5 n min - 6 585 5 8 P e W 6 6 66 69 I A.... qv m /h 88 795 68 5 p fs Pa 6 8 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no. 76-5-998 Revision 87 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE-HK8- Charts: Air flow 6 Hz Druck p f s[pa]für Rho=,kg/m^ 9 85 8 75 7 65 6 55 5 5 5 5 5 5 95 9 85 8 75 7 65 6 55 5 5 5 5 5 5 5 qv[cfm] 6 7 qv[m^/h] 5 8 9 6.. 7.,76,7,7,7,68,66,6,6,6,58,56,5,5,5,8,6,,,,8,6,,,,8,6,,,,8,6,,,,8,6,,. pfs_e[in HO] Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 7 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V f Hz 6 6 6 6 n min - 95 85 75 P e W 7 7 77 8 I A....6 qv m /h 95 8 57 p fs Pa 6 95 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no. 76-5-998 Revision 87 Release -5-8 Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com