Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P

Similar documents
Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

SELECTION GUIDE. BULLETIN 156 Solid-State Contactors

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays Industrial, 1-Phase ZS, Standard Range Types RA /RA /RA

SOLID STATE RELAY RATINGS

RN Thyristor Controllers

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

Solid State Relays Zero Switching Types Solid State Contactor

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

1-Phase Integrated Heatsink Zero Cross or Instant On Switching

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection

Industrial, 2-Pole ZS Type RA2A

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Solid State Relays Industrial, 1Phase Peak Switching Type RM1C

Solid State Relays 1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relays 3-Phase with Integrated Heatsink Types 2 & 3 Pole

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..

Solid State Relays Zero Switching Types RGC Solid State Contactor 'E' Connection

Semiconductor contactors, Solid-state relays

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'E' Connection. Product Description RGC 1 A 60 A 30 K K E _.

Solid State Relays 1-Phase with Integrated Heatsink Proportional Switching Controllers Types RGC1P..AA.., RGC1P..V..

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

2PSS60A40 Solid State Relays 3-Phase with Integrated Heatsink

PCB MOUNT SOLID STATE RELAY ESR2 SERIES

Subject to changes 11/2003 Page 1/7

2-pole solid state relays

2-pole solid state relays

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

Pole "Common" Jumper 10 postion jumper - Red

Solid State Relays 1-Phase with Integrated Heatsink Zero Cross or Instant On Switching Types RGC Solid State Contactor 'E' Connection

05/09/2012

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

Solid-state Contactor Specifications

Control Input. Status Ouputs. 0 to 24VDC 1A AC/DC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

3 Input (+) & 4 Input (-) 1 & 2 Output

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Type CP-S, CP-C & CP-A Switch mode

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC. 4-20mADC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Semiconductor contactors, Solid-state relays

Motor Controllers 3-Phase Analog Power Controller Types RSC-AAM60/RSO...

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Solid State Relays 3-Phase with Integrated Heatsink Types RGC2, RGC3

Switching Power Supply Type SPP1 60W Enclosed type

Food Preparation Equipment Plastic Molding Lighting Control Dual Solid State Relays SEN Produkte, Support und Service TRONICAG

Motor Controllers Soft Starting/Soft Stopping Types RSC-AAM60/RSO...

AQ-R SOLID STATE RELAY FEATURES

02/11/2015

38 Series - Relay Interface Modules A

Solid State Motor Contactor 3 Phase Motor Reversing Types REC2R

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

46.61 Series, SPDT 16A. Part Number Price Coil Voltage

Electronic timer CT-TGD.22

CI-tronic Soft start motor controller

Power supply CP-D 24/4.2 Primary switch mode power supply

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

08/07/2015

Power supply CP-D 24/1.3

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

02/11/2015

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Millenium II + Standard. Specifications. Dimensions. General characteristics

Solid-state Contactor Specifications

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Cylindrical type proximity sensor

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

Power supply CP-E 24/0.75

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

CP-T range Product group picture

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Power supply CP-D 12/2.1

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

Solid-state Timer H3DS

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Legacy Schneider Electric Solid-State Relays. Catalog

OBSOLETE. Replaced by PVA33N. Series PVA33 Microelectronic Power IC BOSFET Photovoltaic Relay Single-Pole, 130mA, 0-300V AC/DC

LDR3 Outline Dimensions. Dimension Inches Millimeters

Magnecraft Solid State Relays

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

Solid State Relay, 1-phase

Description. Features. As low as 8mA max holding current. UL Recognized TO- 220AB package. 110 C rated junction temperature

38 Series - Relay interface modules A. Features /

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Advantages of the 70S2 Series

celduc r e l a i s Proud to serve you MOSFET BASED DC SOLID STATE RELAY SCM VDC 600VDC 40ADC Page 1/5 GB

celduc r e l a i s Proud to serve you celduc MOSFET BASED DC SOLID STATE RELAY SCM VDC 200VDC 100ADC Page 1/5 GB

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Standard Rectifier Module

Transcription:

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P AC semiconductor contactor Multi-function - 5 selectable modes of operation: Phase Angle, Distributed Full Cycle and Burst Control (1, 3 and 10s) Direct copper bonding (DCB) technology LED-indication for control and load status Operational ratings up to 50 AACrms and 600 VAC 4-20mA or 0-10V control input Built-in varistor Blocking voltage: Up to 1200Vp Opto-isolation > 4000VACrms Cage clamp terminals IP20 protection Option for over-temperature protection with alarm output Product Description The Solitron Midi Analog Switching is a single-phase SSR that provides proportional output power in relation to the control signal level applied. This microprocessor-based device provides for 5 different switching modes integrated into one package. A selector switch on the front of the device is used for the selection of the preferred mode of operation, i.e., either Phase Angle, Distributed Full Cycle or Burst Control. This multi-function selection makes this device ideal for the control of a variety of loads, including heaters and lamps. The control signal can be either 4-20mA or 0-10VDC. 4mA or 0V correspond to zero output power, whilst 20mA or 10VDC correspond to full output power. The product is ready to mount on DIN-rail or chassis and comes with integral heatsink. Ordering Key Solid State Relay Number of poles Switching mode (Proportional) Rated operational voltage Control input type Rated operational current Terminal layout Over-temperature protection Alarm output type RJ 1 P 48 V 50 E P PO Type Selection Switching Rated operational Control Rated operational Terminal Protection Alarm mode voltage input current layout output type P: Proportional 23: 230VACrms V: 0-10VDC 30: 30AACrms E: Contactor P: Over- PO: * 1 Output 48: 480VACrms I: 4-20mA 50: 50AACrms temperature NO: * 2 60: 600VACrms protection *1 PNP, Normally Open *2 NPN, Normally Open Selection Guide Rated operational Blocking Control Supply Alarm Rated operational current voltage voltage input voltage output type 30 A 50 A 230VACrms 650Vp 0-10VDC 24VAC/DC - RJ1P23V30E RJ1P23V50E PO RJ1P23V30EPPO RJ1P23V50EPPO 4-20mA - RJ1P23I30E RJ1P23I50E PO RJ1P23I30EPPO RJ1P23I50EPPO 480VACrms 1200Vp 0-10VDC 24VAC/DC - RJ1P48V30E RJ1P48V50E PO RJ1P48V30EPPO RJ1P48V50EPPO 4-20mA - RJ1P48I30E RJ1P48I50E PO RJ1P48I30EPPO RJ1P48I50EPPO 600VACrms 1200Vp 0-10VDC 24VAC/DC - RJ1P60V30E RJ1P60V50E 4-20mA - RJ1P60I30E RJ1P60I50E Note: Alarm Output: EPNO (NPN, normally open) and 600V types available only on request Specifications are subject to change without notice (05.10.2007) 1

General Specifications RJ1P23... RJ1P48... RJ1P60... Operational voltage range 90 to 265VAC 200 to 550VAC 410 to 660VAC Blocking voltage 650V p 1200V p 1200V p Operational frequency range 45 to 65Hz 45 to 65Hz 45 to 65Hz Output power 0 to 99% 0 to 99% 0 to 99% Power factor 0.9 @ 230VACrms 0.9 @ 480VACrms 0.9 @ 600VACrms Load status indication Red LED Red LED Red LED Output power resolution MODE 1 Phase Angle 1/300 @ 50Hz, 1/300 @ 60Hz MODE 2 Full Cycle 1/64 @ 50Hz, 1/64 @ 60Hz MODE 3 Burst with 1s period 1/50 @ 50Hz, 1/60 @ 60Hz MODE 4 Burst with 3s period 1/150 @ 50Hz, 1/180 @ 60Hz MODE 5 Burst with 10s period 1/500 @ 50Hz, 1/600 @ 60Hz Approvals UL, cul* CE-marking Yes * Approvals pending for RJ1P...P.O models Input Specifications RJ1P..I... Current controlled input Control current range 4-20mA Max. allowable input current 50mA Pick up current 4.2mA Drop out current 3.9mA Control status indication Green LED Reverse polarity protected Yes Voltage drop 10VDC @ 20mA Note: the use of twisted pair cable for the control input is recommended Voltage controlled input Supply voltage range, Vss Supply current Control voltage range, Vcc Control input current Reverse polarity protected Pick up voltage Drop out voltage Control status indication RJ1P..V... 20-28VAC/DC 18mA @ 24VDC 23mA @ 24VAC 0-10VDC 0.1mA @ 10VDC Yes 0.5VDC 0.05VDC Green LED Output Specifications RJ1P...30 RJ1P...50 Rated operational current AC51 @Ta=25ºC 30AACrms 50AACrms Min. operational current 150mAACrms 500mAACrms Rep. overload current t=1 s (Tj init.=25 C) < 55AACrms < 200AACrms Non-rep. surge current t=10 ms (Tj init.=25 C) 325A p 1900A p Off-state leakage current, @ rated voltage and frequency < 3 marms < 3 marms I 2 t for fusing t=10 ms 525A 2 s 18000A 2 s On-state voltage drop @ rated current 1.6Vrms 1.6Vrms Critical dv/dt off-state 1000V/µs 1000V/µs Isolation Thermal Specifications Rated isolation voltage Input to output Output to case 4000 VACrms 4000 VACrms Operating temperature Storage temperature -20 to +70ºC (-4 to +158 F) -40 to +100ºC (-40 to +212 F) 2 Specifications are subject to change without notice (05.10.2007)

Connection Examples - + 4-20mA 0V - + 10VDC 1L1 5A3 3A1 1L1 5A3 3A1 LOAD LOAD 2T1 6A4 4A2 2T1 6A4 4A2 24VDC/AC + - 0V 3A1-5A3: Control input current Example: RJ1P48I..E 3A1-5A3: Control input voltage, Vcc 4A2-6A4: Supply input voltage, Vss Example: RJ1P48V..E 0V - + 4-20 ma 0V - + 10 VDC 1L1 5A3 3A1 1L1 5A3 3A1 LOAD LOAD 2T1 6A4 4A2 2T1 6A4 4A2 24VDC/AC + - Over-temperature Alarm Output 3A1-5A3 : Control Input Current Ic (4-20mA) 6A4 : Supply Voltage Vss (24VDC) 4A2 : Alarm output, NPN Normally Open Example: RJ1P48I..PNO 24VDC/AC + - Over-temperature Alarm Output 3A1-5A3 : Control Input Voltage Vcc (0-10V) 6A4 : Supply Voltage Vss (24VAC/ DC) 4A2 : Alarm output, PNP Normally Open Example: RJ1P48I..EPPO Note: For the RJ1P..V..E, it is possible to have the ground terminals of the supply and control power supplies used commoned. In the case, this common ground is connected either to terminal A2 or terminal A3. This is only applicable when a 24 VDC supply voltage is used. There should be no external direct link from Terminal A2 to Terminal A3. Alarm Specifications Output current 50 madc Output voltage NPN 1V PNP (Voltage version) Vcc - 1-82 io PNP (Current version) Vcc - 3 (0.50 ma) No. of outputs in parallel 50 Specifications are subject to change without notice (05.10.2007) 3

Operation MODE 1: The Phase Angle switching mode works in accordance with the phase angle control principle, i.e. the output switching point in the AC sine wave depends on the signal level applied at the input. The relay switches off everytime the output current crosses zero. MODE 2: The Distributed mode provides a number of full cycles, evenly distributed over a fixed period of 1.28s @ 50Hz (1.07s @ 60Hz), depending on the control input. Terminal Layout MODE 3, 4, 5: The Burst Switching mode generates a number of full cycles, depending on the control input over fixed periods of 1s, 3s or 10s for MODES 3, 4 and 5 respectively. Modes 2, 3, 4 and 5 use the zero switching principle, thus ensuring a reduced level of radiated and wire-conducted noise. The Distributed and Burst Switching modes are not recommended for light control due to light-flickering. LED INDICATION The top RED LED indicates the load status. It goes ON whenever the load is activated, and in the RJ1P P..O models this led is used to indicate an over temperature alarm. The Green LED gives indication of the status of the control input. Upon application of control current (for the RJ1P..I..) to terminals A1 A3, the Green LED will be dimly lit, with its intensity increasing with an increase in control current. For the RJ1P..V.. the Green LED will be ON (flickering) upon application of the supply voltage to terminals A3 A4. In RJ1P..VE only, terminals A3 and A2 are shorted. Once a control voltage is applied to terminals A1 A3, the Green LED will be fully ON, if greater than a threshold voltage (approx 0.5V). Note that the first time the device (voltage control version) is to be activated, the mains voltage has to be present for the Green LED to indicate the control status. Transfer characteristics Mode Selection Output power as a function of control input MODE 1 Phase Angle Switching Control Control Output MODE 2 Distributed Control Current (ma) Voltage (VDC) Power (%) MODE 3 Burst Switching (1 sec. period) 4 0 0 MODE 4 Burst Switching (3 sec. period) 8 2.5 25 MODE 5 Burst Switching (10 sec. period) 12 5 50 16 7.5 75 20 10 99 Dissipation Curve 50 40 50A W 30 20 30A 10 0 0 10 20 30 40 50 60 AACrms 4 Specifications are subject to change without notice (05.10.2007)

Functional Diagram Alarm Output A2 Supply A4 (+) A3 (-) Control input IC A1 (+) MODE 1 Phase Angle MODE 2 Distributed Full Cycle 1 period = 64 cycles MODE 3, 4, 5 Burst 1s, 3s, 10s, 4, 5 1 period = 1s, 3s or 10s Dimensions Housing Specifications Weight Housing material Control terminal cable size Min Max Mounting torque max. Control terminal screw Power terminal cable size Min Max Mounting torque max. Power terminal screw Approx. 430 g PBT Flame retardant 1 x 0.5 mm 2 (1 x AWG20) 1 x 4.0 mm 2 (1 x AWG12) or 2 x 2.5 mm 2 (2 x AWG14) 0.6 Nm Posidriv 0 bit M3 1 x 4 mm 2 (1 x AWG12) 1 x 25 mm 2 (1 x AWG3) or 2 x 10 mm 2 (2 x AWG6) 2.5 Nm Posidriv 2 bit M5 All dimensions in mm. Specifications are subject to change without notice (05.10.2007) 5

Derating vs. Spacing Curves Load Current (AACrms) 22.5mm/ 10.0mm 6.0mm 3.0mm 0.0mm Surrounding temp. ( C) RJ1P...30 Load Current (AACrms) 22.5mm/ 10.0mm 6.0mm 3.0mm 0.0mm Surrounding temp. ( C) RJ1P...50 Note: Based on 100% output power 6 Specifications are subject to change without notice (05.10.2007)

Derating vs. Spacing Curves (cont.) 55 50 45 Load Current (AACrms) 40 35 30 25 20 15 22.5mm 6.0mm 0.0mm 10 20 25 30 35 40 45 50 55 60 65 70 Surrounding temp. ( C) RJ1P...50EP.O 35 30 Load Current (AACrms) 25 20 15 22.5mm 6.0mm 0.0mm 10 20 25 30 35 40 45 50 55 60 65 70 Surrounding temp. ( C) RJ1P...30EP.O Specifications are subject to change without notice (05.10.2007) 7

Functional Diagram RJ1P..V..E.. Mains Supply 24V Supply Control Input Green LED Red LED Output Alarm PNP* Alarm NPN* Over Temperature Sensing * * Applicable to RJ1P...P..O models only RJ1P..I..E.. Mains Supply 24V Supply * Control Input Green LED Red LED Output Alarm PNP* Alarm NPN* Over Temperature Sensing * * Applicable to RJ1P...P..O models only 8 Specifications are subject to change without notice (05.10.2007)