Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

Similar documents
Ground-based optical auroral measurements

Photons and solid state detection

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Lecture 12 OPTICAL DETECTORS

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Components of Optical Instruments

CCDS. Lesson I. Wednesday, August 29, 12

Engineering Medical Optics BME136/251 Winter 2018

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Scintillation Counters

Astro-photography. Daguerreotype: on a copper plate

Chemistry Instrumental Analysis Lecture 7. Chem 4631

How to take color pictures of aurora

6.014 Recitation 1: Wireless Radio and Optical Links

How Does One Obtain Spectral/Imaging Information! "

An Introduction to CCDs. The basic principles of CCD Imaging is explained.

CCD Characteristics Lab

Basic Components of Spectroscopic. Instrumentation

CHAPTER 11 HPD (Hybrid Photo-Detector)

Dynamic Range. Can I look at bright and faint things at the same time?

Introduction. Laser Diodes. Chapter 12 Laser Communications

Components of Optical Instruments 1

Lecture Notes Prepared by Prof. J. Francis Spring Remote Sensing Instruments

Light Collection. Plastic light guides

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Infrared Detectors an overview

Silicon Photomultiplier

IV DETECTORS. Daguerrotype of the Moon, John W. Draper. March 26, 1840 New York

Radiation transducer. ** Modern electronic detectors: Taking the dark current into account, S = kp + bkgnd over the dynamic range.

Monte Carlo PMT Simulation

arxiv:hep-ex/ v1 19 Apr 2002

OFCS OPTICAL DETECTORS 11/9/2014 LECTURES 1

Meshing Challenges in Simulating the Induced Currents in Vacuum Phototriode

Learning Objectives. Understand how light is generated in a scintillator. Understand how light is transmitted to a PMT

Lecture 2. Electromagnetic radiation principles. Units, image resolutions.

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

PoS(PhotoDet 2012)058

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors

Observational Astronomy

Characterisation of SiPM Index :

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

Radiation detectors Photographic detection

1170 LIDAR / Atmospheric Sounding Introduction

CHAPTER 3 BASIC OPERATING METHODS OF PHOTOMULTIPLIER TUBES

Silicon Photo Multiplier SiPM. Lecture 13

CERN LIBRARIES, GENEVA

2013 LMIC Imaging Workshop. Sidney L. Shaw Technical Director. - Light and the Image - Detectors - Signal and Noise

Photoelectric effect

Introduction to CCD camera

Last class. This class. CCDs Fancy CCDs. Camera specs scmos

Low Cost Earth Sensor based on Oxygen Airglow

Experiment 10. The Speed of Light c Introduction Apparatus

The Benefits of Photon Counting... Page -1- Pitfalls... Page -2- APD detectors... Page -2- Hybrid detectors... Page -4- Pitfall table...

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

Multichannel Scanning Auroral Photometer

Detectors for Sensitive Detection: HyD

the need for an intensifier

General Imaging System

Cameras CS / ECE 181B

High collection efficiency MCPs for photon counting detectors

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

event physics experiments

Optical/IR Observational Astronomy Detectors II. David Buckley, SAAO

Properties of a Detector

SCCH 4: 211: 2015 SCCH

Image Formation and Capture. Acknowledgment: some figures by B. Curless, E. Hecht, W.J. Smith, B.K.P. Horn, and A. Theuwissen

SUPPLEMENTARY INFORMATION

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

3/5/17. Detector Basics. Quantum Efficiency (QE) and Spectral Response. Quantum Efficiency (QE) and Spectral Response

Silicon sensors for radiant signals. D.Sc. Mikko A. Juntunen

SECONDARY ELECTRON DETECTION

Absorption: in an OF, the loss of Optical power, resulting from conversion of that power into heat.

Charged Coupled Device (CCD) S.Vidhya

TSBB09 Image Sensors 2018-HT2. Image Formation Part 1

BASICS OF FLUOROSCOPY

SPMMicro. SPMMicro. Low Cost High Gain APD. Low Cost High Gain APD. Page 1

Week 9: Chap.13 Other Semiconductor Material

Pixel hybrid photon detectors

LE/ESSE Payload Design

Development of New Large-Area Photosensors in the USA

The Light Amplifier Concept

The Charge-Coupled Device. Many overheads courtesy of Simon Tulloch

combustion diagnostics

Chapter 4 OPTICAL DETECTORS

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Fundamentals of CMOS Image Sensors

5. Scintillation counters

The new CMOS Tracking Camera used at the Zimmerwald Observatory

Cosmic Ray Detector Hardware

Detectors that cover a dynamic range of more than 1 million in several dimensions

5. Scintillation counters

Gamma Spectrometer Initial Project Proposal

Single Photon Interference Laboratory

Antennas and Propagation. Chapter 5

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

Transcription:

Ground-based optical auroral measurements FYS 3610 Background Ground-based optical measurements provides a unique way to monitor spatial and temporal variation of auroral activity at high resolution up to 10 meters near optical zenith. All-sky camera Photometer CCD All-sky Camera with filterwheel Monochromatic filtering/ Narrow band interference filter Image intensifier The half-width is about 2-3 nm Page 1

CCD light detector Charge-coupled device (CCD) Each detector element (pixel) measures the intensity in incoming light, and sends out a signal which is proportional with the light intensity. The pixels are arranged in an array; typically 512 x 512 and up to 2000 x 2000 pixels. More pixels = higher resolution and more data 512 Detector array Consist of thousands of light sensitive elements arranged in an array. Each element is an oxide semiconductor (MOS) capacitor. The photoelectric effect produce charges on this capacitors. Modern pixel sizes are between 4 and 10 µm in height and width 512 Charge-coupled device (CCD) The charges in each capacitor row is shifted to the output, and each charge is converted to a voltage. The advantage of the CCD is that no high voltage is required (compared to the photomultiplier). The disadvantage is low time resolution (because it is an integrating type of detector) and it is therefore not suitable to look at very weak photon sources ( without use of a light amplifier) Charge-coupled device (CCD) The quantum efficiency (QE) is typically 40 to 80 % for a CCD. But, even if a photon produce one electron in the detector, this electron is not necessary detected at the detector output. Because this photon can get lost during signal transportation or be burried in noise. So QE is not a good measure of how good the detector system is. Colours in the aurora Geometry of auroral observations 630.0 nm red upper boundary Atomic Oxygen: 1 D- 1 S transition 557.7 nm green Atomic Oxygen : 1 D - 3 P transition 427.8 nm magenta lower boundary N + 2 - First neagtive band Figure: Farge som funksjon av høyde Page 2

Be also aware of flipping!! Optics Detector array White light image from ARR unmapped Gegraphical coverage depends on emission altitude PHOTOMETERS 630.0 nm image mapped to 250 km altitude Photometer Measures the light intensity (for a given wavelength). Very sensitive. Good spatial resolution and time resolution. A photometer cannot image the auroral morphology, so it is used as a supplement to all-sky cameras. Photometers Operational mode It can be pointed at a fixed point (a given elevation). But this doesn t give any scientific interesting data, since aurora forms typicaly has an extension of 100 1000 km. Therefore it is used in a scanning mode, where the instrument sweeps out a larger area. There are two possible modes: Meridian scanning Azimuth scanning Meridian scan Azimuth scan Page 3

Photometers A photometer (with mobility around horizontal and vertical axes) can be programmed to follow a rocket trajectory, to compare the measurements of the particle precipitation and the aurora. Photometer Optics Light detector Electronics/signal processing Optics and filters The optical part can be a lense or a lense system, used to focus the light on the detector(s). A filter is used to transmitt only particular wavelengths to the detector. Two common type of filters: Interference filter Absorbtion filter The bandwidth of an absorption filter is much larger than for an interference filter. Optics angular field of view The angular field of view decide how much of the sky the detector sees, and with that the photometers spatial resolution. We want as large resolution as possible (small angular field of view), but at the same time as much light as possible into the detector. This is incompatible. A common compromise is to have an angular field of view of ~ 2 (the angular field of view of the moon seen from the earth is ~ 0.5 ) Optics angular field of view A lense system can be used to define the angular field of view. A singel lense and an aperture opening in front can be used to define the angular field of view. Photon Detector The detector is usually a photomultiplier A Charge-Coupled Device (CCD) can also be used, and CCD based photometers are used in many satellites. In satellites and rockets the photomultiplier tubes and the high voltage source are usually sealed in a silicone die, to prevent corona discharge and to attenuate (damp down) the vibrations. Page 4

Photomultiplier (PM) When a photon of sufficient energy is incident on the photocatode, a single electron may be ejected (refered as a photoelectron). The probability that a single photon produce a photoelectron that is detected in the phototube is called the quantum efficiency (QE). Photomultiplier QE is a function of the wavelength of the incident photon. A typical value for quantum efficiency in a phototube is 20-30% ( at wavelength of 400 nm). The photoelectron is accelerated through a potential difference, and hits a secondary electrode called a dynode. At the this first dynode the photoelectron frees other electrons, and this secondary electrons are accelerated and focused on a second dynode and so on. Photomultiplier The multiplication effect take place at the dynodes, and the process results in an increasing number of available electrons (avalanche effect). The electrons are guided by the electrostatic field between the dynodes. An external magnetic field can distort the focusing, as the electrons travel from dynode to dynode. Therefore the photomultiplier tubes are shielded. Photomultiplier A photomultiplier typically have 10 12 stages (dynodes) and a multiplication of ~ 10 6 This signal is easily detected in an external circuit. The total voltage (the potetial difference between the photocatode and the anode) is typically 1000 2000 volt. Photomultipliers are sensitive detectors of single photons, and as such are designed to operate in the dark. Electronics /signal processing The output signal from the photomultiplier is current pulses, where each pulse correspond to a detected photon. This current pulses are converted to voltage pulses by a current to voltage converter. Some of the voltage pulses generted are caused by noise, and thereby not desired. To eliminate them, a voltage discriminator is inserted. The discriminator is adjusted to remove all pulses with an amplitude smaller than a predefined limit. Noise There are several noise sources, but the dominating noise source fore the photomultiplier tube is thermal electron emission from the photocatode (can be reduced by cooling). This noise result in whats known as dark current or dark counts; dark counts is the number of counts made by the photmultiplier when it is in complete darkness. The dark current must be as low as possible, since it sets the lower limit on how low intenisty the instrument can detect. Page 5

Meridian Scanning Photometer data from Longyearbyen Page 6