A C T Advanced Communication Tester

Similar documents
A C T Advanced Communication Tester

A C T Advanced Communication Tester

20Hz to 2.2MHz Transmissive Measurements

ACT6000 Advanced Communication Tester

ALT2000 Advanced Line Tester

AXS-200/ MHz COPPER TEST SET

MaxTester 610 KEY FEATURES AND BENEFITS THE MAXTESTER 600 SERIES SPEC SHEET SMARTER COPPER TESTING FOR INSTALLATION TECHNICIANS

AXS-200/ MHz COPPER TEST SET. part of the SharpTESTER Access Line. Telecom Test and Measurement

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Dynatel 900 Series Subscriber Loop Test Sets

Opternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)

T-BERD /MTS-4000 Multiple Services Test Platform Copper Services Module

Results You Can Count On

FTB-610 Wideband Copper Test Module

Opternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

Acterna DSL-311 and DSL-322 DSL Copper Testers

Analog Arts SF990 SF880 SF830 Product Specifications

SDM3045X Digital Multimeter. DataSheet

Spectrum Analyzers 2680 Series Features & benefits

Dynatel 965DSP / 3M Far-End-Device Setup

FREEDOM Communications System Analyzer R8000C DATA SHEET

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

FREEDOM Communications System Analyzer R8100 DATA SHEET

TSA 6000 System Features Summary

DSA700 Series Spectrum Analyzer

FM Modulation. Accuracy. Total. Harmonics. Input Range. Frequency. Range. Deviation. Range. Modulation. Accuracy. Audio In Switchable Loads.

Analog Arts SF900 SF650 SF610 Product Specifications

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

FREEDOM Communications System Analyzer R8000C DATA SHEET

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

3M Dynatel Far End Device III

QUICK REFERENCE GUIDE

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

DIGITAL LINK MEASURING INSTRUMENTS MS371A/A1 GPIB PCM CHANNEL ANALYZER. For Simultaneous Measurement of 30 Channels with MS120A

FREEDOM Communications System Analyzer R8100 DATA SHEET

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

SDM3045X Digital Multimeter. DataSheet

Far End Device II Model 1342

FREEDOM Communications System Analyzer R8100 DATA SHEET

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Cable TV Spectrum Analyzer

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE

Keysight Technologies N9320B RF Spectrum Analyzer

Handheld Digital Storage Oscilloscopes 2510 Series

Agilent N9320B RF Spectrum Analyzer

Description, operating instructions and hardware specification of the HL Transverse balance measurement module (TBMM).

FREEDOM Communications System Analyzer R8600 DATA SHEET

2-channel models. 4-channel models

HT1000/2 Series Copper Wire Analyser

APPH6040B / APPH20G-B Specification V2.0

CopperPro Series II. The complete test set for qualifying your local loop for ADSL, VDSL and special services.

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

khz to 2.9 GHz Spectrum Analyzer

U1604A Handheld Oscilloscopes, 40 MHz

Arbitrary/Function Waveform Generators 4075B Series

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

HZ530 Near-Field Probe Set

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

Product Specification File

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

RS Pro HANDY OSCILLOSCOPE RSHS800 SERIES

Chapter 5 Specifications

Requirements and Test Methods for Very-High-Bit-Rate Digital Subscriber Line (VDSL) Terminal Equipment

RS Pro HANDY OSCILLOSCOPE RSHS800 SERIES

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

Vector Network Analyzers ZVB

Divide. MHz models) waveform record

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Hantek2000 Series 3u1 Oscilloscope+DMM+AF generator

Copper Lines and High Speed

VC-4/4A, VC-8/8A, VC-16

APPA 300 Series. The Most User-Friendly High Performance Multimeter

Keysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Acterna DSAM Product Family

Agilent CSA Spectrum Analyzer

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

Specification for Conducted Emission Test

Models 296 and 295 combine sophisticated

MIT480/2 Insulation testers

Agilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set.

Model 7000 Series Phase Noise Test System

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Spectrum Analyzer FSL

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

Fluke 192/196/199. ScopeMeter. Users Manual

Copper Loop Frequency Management Plan

Transcription:

A C T 6 0 0 0 Advanced Communication Tester SINE SIGNAL & NOISE GENERATOR - SELECTIVE LEVEL METER CROSS TALK METER - SPECTRUM & NETWORK ANALYZER LONGITUDINAL BALANCE & RETURN LOSS METER MICROINTERRUPTION & IMPULSIVE NOISE METER VOLTAGE - RESISTANCE - CAPACITANCE METER TDR & RESISTANCE FAULT LOCATOR POTS DEVICE SIMULATOR ALL ON THE PALM OF YOUR HAND! This new instrument combining various kinds of transmission, metallic and special tests, may be considered up to today the most advanced Test Set for qualifying and maintenance of advanced transmission systems and copper pairs used for various telecommunication services: POTS ISDN T1 E1 HDSL 1/2P SHDSL ADSL ADSL2+ VDSL2 ERGONOMIC CHARACTERISTICS One of ACT6000 most interesting features is the colour LCD high resolution graphic display, a real window on the most advanced measurements world. The keypad, the function keys, connections and interfaces on the upper panel grant to the instrument a high operating level. DATA-COMMUNICATION CHANNELS & COPPER PAIRS QUALIFICATION / CERTIFICATION One ACT6000 can perform easy and quick Single-End Line Tests or specific End-to-End Line Tests if coupled with another ACT6000. The wide kind of measurements of the ACT6000 allows the qualification and certification on various communication carriers and copper pairs used for digital streams with a frequency occupancy up to 6 MHz (or 30 MHz optional); moreover, the instrument can automatically extrapolate the ADSL, ADSL2+ and VDSL2 maximum expected data rate of the copper line under test. COPPER PAIRS DIAGNOSTIC & FAULTS FINDING / LOCATION ACT6000 can be configured for high troubleshooting mission, by special functions and internal optional modules. The complete adoption of these modules allows the simple and fast finding and localization of anomalies and/or faults on the copper line and communication systems.

ACT6000 Typical Applications examples AUTOMATIC SINGLE-END LINE QUALIFICATION Adopting the optional ASW-1 software, after the quick cable selection among the many types included on the data base, it is possible to start an Automatic Sequence to perform a complete set of electrics and transmissive tests to qualify the line for a specific service. For the ADSL, ADSL2+ and VDSL2 services, over the mentioned electrical and transmissive tests, the S/N Ratio and maximum Bit-Rate estimation are added. Finished the Sequence (about 100 seconds), a summary table appear on the screen with pass/fail indication (in red) for each result according to the international acceptability criteria and transmissive masks (ETSI or ANSI). The results can be saved on the internal memory and then visualized or exported on the USB pen-drive as.csv file (Windows Excel compatible) or as.bmp photo of the screen. FALUTS LOCATIONS A powerful TDR allows the quick finding of the End-of-Line but also the location of possible faults or anomalies as: interruptions, short circuits, low insulation, bridge-taps, split-pairs, and also the possible micro-interruptions thanks to the Sample & Hold test modality. Other important available function is the Resistive Bridge - Fault Locator that allows to localize various combinations of low insulations points. POWER SPECTRUM DENSITY (HIGH IMPEDANCE) The ACT6000 s Spectrum Analyzer can operate on various frequency bands, readout mode and also with special Front/End configuration as the High Impedance. Using the High Impedance configuration (not intrusive mode), it is possible to perform the PSD to verify the spectrum and energy of any digital stream (i.e. to extrapolate the ADSL, ADSL2+ and VDSL2 profile) connecting the input instrument in parallel to the active and powered line. Other PSD application is to perform a quick signals map staying on the Main Distribution Frame or Street Cabinet.

ACT6000 TECHNICAL CHARACTERISTICS General Case: ABS shielded for EMI / EMC compatibility. Connections: "RTX" connector IN/OUT and TX OUT triple banana-jack; polarized connector for external supply; RJ-45/4 connector for headset; USB & RS232 port for PC connector; USB for Pen-drive connector. Display: LCD color 320 x 240 pixel (1/4 VGA) back-lighted and reverse. Power supply (internal): rechargeable battery pack (green) 2 x 4 NiMh 1.2 V / 2.7A, for 8 hours (mid.) of continue operation with battery state indication. external: from 16,5 to 26,5 Vdc / max 2,5 Ah. Dimensions and Weight: 150 x 210 x 50 mm / 1,5 Kg. (batteries included). Temperature range: operative: -5 +45 C. / stock -20 +70 C. Humidity range: 5 90% no-condensing. Overvoltage Protection: In/Out connectors up to 150 Vdc / 140 Vpp. Reference Frequency accuracy: ±1 ppm within the operating temperature ±2 ppm/year. Reference Level accuracy: ±0.025% within the operating temp. ±0.025% / year. CE mark - EMC: Directive 2004/108/CE, 89/336/EEC, Decree 2007/194 CISPR 11, ISO 14253 and CEI EN: 61326/A1/A2,55011, 61000-4-2, 61000-4-3, 61000-4-4, 61000-4-6, 61000-4-11 Special Features and Setup: Software update and Results Export using USB Pen Drive or USB cable to PC; Results Storage on internal flash memory. Signal Generator Sine output frequency range: base band: from 20 Hz to 20 khz; middle band: from 20 khz to 6 MHz; high band (optional): from 0.02 to 30 MHz. Frequency Resolution: 1 Hz up to 9.999999 MHz; 10 Hz over 10.0 MHz. Frequency setup mode: manual on single frequency and steps mode on programmable band / steps. Output level: -60 +20 dbm @ 150 Ω / 0.1 db steps. Output level accuracy: ±0.2 db from 100 Hz to 20 khz; ±0.2 db up to 2 MHz, ±0.3 db up to 6 MHz; ±0.5 db up to 30 MHz. Balanced output impedances: base band: 150, 200 and 600 Ω; middle band: 100, 110, 120, 135, 150 and 1350 Ω; Unbalanced output impedances: 50 and 75 Ω by Banana/BNC optional adapter. White Noise Generator: 1 khz 6 MHz /-74-144 dbm/hz /0.1 db steps Signal & Level Meter Frequency range: from 100 Hz to 6 MHz (two bands) base version; up to a 30 MHz (with EBM 30 optional module). Manual tuning / resolution: 1 Hz up 9.999999 MHz; 10 Hz over 10.0 MHz. Level measurements mode: absolute (dbm or dbv or Volt) or rel. (dbr). Input range: -120 +12 dbm @ 100 Ω / 0.1 db Resolution. Level meter accuracy: ±0.2 db from 100 Hz to 20 khz; ±0.2 db up to 2 MHz, ±0.3 db up to 6 MHz; ±0.5 db up to 30 MHz. Noise floor (TX OFF): -140 dbm/hz Frequency Meter sensitivity: -40 dbm on wide band or selective mode. Input impedances balanced: base band: 150, 200, 600 and >10 kω; middle band: 100, 110, 120, 135, 150 Ω; Input impedances unbalanced: 50 and 75 Ω by Banana/BNC adapter. Noise filters: base band: psophometric; C-Message; 0.3 3.4 khz 0.02 3.4 khz, 0.3 6.0 khz, 0.02 6.0 khz, 0.3 15.0 khz, 0.02 15.0 khz, 0.3 20.0 khz, 20 20.0 khz, 20.0 khz flat, middle/high band: E, F, G and VDSL.2-12 -17 and 30. Selective filters / notch: base band: (200 Hz 20 khz) pass band and Notch filter for S/N+D (db and %) test; - 10 Hz @ fo <200 Hz; - 5% fo >200Hz / <4 khz; - 200 Hz @ fo >4 khz. Selective for telegr.chann:120, 240, 360, 480 Hz. high band (20 khz 6 or 30 MHz) selective: 25, 100, 200, 400 Hz; 1.74, 3.1, 4.0, 8.0, 16.0 khz. Spectrum and Network Analyzer Frequency range: from 200 Hz to 6 MHz (two band) base version; up to 30 MHz (by optional module EBM 30). Input impedances balanced: base band: 150, 200, 600 and >10 kω balance; middle band: 100, 110, 120, 135, 150 Ω; Input impedances unbalanced: 50 and 75 Ω by Banana/BNC optional adapter. Measure Resolution and Method: - Base band: 200 25000 Hz, by FFT analyzer (Kaiser window). Span: 6250, 12500 and 25000 Hz. Resolution Horizontal: 625 (+ zoom), 1.250, 2.500 Hz / Division, with 250 pixel / 10 div. Resolution Vertical: 1, 2, 3 20 db / div. with 192 pixel / 8 div. Resolution (BW): 50, 100, 200.. Hz (other resolutions are interpolated). - Middle band: 1 khz to 6 (30) MHz, by digital SSB quad. Conversion. Span: 30 ranges: from 10 to 8000 khz, 10 per decade. Resolution Horizontal; 1, 2, 4, 8, 16.. 800 khz / div. with 250 pixel / 10 div: Resolution Vertical: 1, 2, 3 20 db / div. with 192 pixel / 8 div. Resolution (BW): 0.2, 0.5, 1, 2, 5, 8 khz (other resolutions are interpolated) - High band (optional) measure method: Double convers. Receiver Span: 0 12, 0 18 and 0 30 MHz. Resolution Horizontal; 1.2, 1.8 and 3 MHz / div. Level reading mode: absolute: dbm, dbm/hz, dbv and dbr (relative). Measurement mode: normal, peak (max, mean or min. value), 2 Wires +/- (for Return-Loss meas.), 2 Wires +/+ (for Longitudinal Balancement meas.) and 4 Wires. Input range: -100 +12 dbm @ 100 Ω Noise floor: -140 dbm/hz @ 100 Ω (high band) with 16 khz filter. Resolution marker (lev. / freq.): 0.1 db / as selected resolution (BW). Network Analyzer: by tracking generator or single freq. in 2/4 wires mode. Mix measurements Generator/Meter and Network Analyzer Cross-Talk (4 Wires) Test mode: Near-End (Single-End) and Far-End (End-to-End) single frequency or scanner on limited band. Frequency range: 200 Hz 6 MHz (up to 30 MHz - EBM 30 opt. module) Measurement accuracy: - up to 2 MHz: ±1 db / between 0-90 db; - up to 6 MHz: ±2 db / between 0-86 db; - up to 30 MHz: ±3 db / between 0-80 db. Intrinsic crosstalk: - 90 db (with precise resistive load). Return Loss ( 2 wires) Test mode: single frequency or scanner on limited band. Frequency range: 200 Hz 6 MHz (up to 30 MHz - EBM 30 opt. module) Measurement accuracy: - up to 2 MHz: ±1 db / between 0-50 db; - up to 6 MHz: ±2 db / between 0-46 db; - up to 30 MHz: ±3 db / between 0-40 db. Longitudinal Balance Loss ( 2 Wires + Gnd) Test mode: single frequency or scanner on limited band. Frequency range: 200 Hz 6 MHz. Measurement accuracy: - up to 2 MHz: ±1 db / between 0-60 db; - up to 6 MHz: ±2 db / between 0-56 db; Single-End Insertion Loss (included on the Single-End-Line-Testing) * Measuring Mode / readout: by FDR technology on High-Band / Spectral readout.

Operating Band: direct: 100 khz 1000 khz Graphic Extrapolation: 20 khz 6MHz and 30 MHz. Operative Impedance: 120 Ω (default) balanced line. Accuracy: ±1 db up to 2.2 MHz; ±2 db up to 30 MHz. Operative limits: - minimum line length: 50 meters; - maximum line length: 4 km (0.4 mm wire gauge). Event Tests Micro-Interruptions - O.62 (base band) and wide band Threshold level: -3-20 db - 2 khz Test Tone (default) or on programmable frequency up to 6 MHz. Monitoring time: 4 min. 24 ours. Events indicators: 5 Counters (0.3ms >1min); Event/Time; Secs. with Events. Readout: Tabular and Time Domain Histogram representation. Measure facilities: reference tone output from TX connector for loopback tests. Impulsive Noise O.71 (base band) and wide band - Threshold level: 0-60 dbm. - Base band BW filters: 200 12,000 Hz Flat, 600 3,000 Hz, 300 500 Hz. - Monitoring time: 4 min. 24 hours. - Events indicators: 1 Event Counter; Event/Time Ratio; Secs with Events. - Readout: Tabular and Time Domain Histogram representation. Special Measurements Line Immunity by White Noise injection - Output level range: -70-144 dbm/hz @ Zref. 100Ω - 0.1 db Resolution. - Output impedance: 100, 120, 135, 150 and 1350 Ω (balanced). - Bandwidth: 1 khz 6 MHz. TDR Fault locator Distance ranges: 90, 180, 450, 900, 1800, 3600, 7200 m. @ 0.600 PVF. Zoom: vertical: -8 +77 db; horizontal : 1x, 2x, 4x. Distance resolution (by marker): - minimum range: about 0.4 meters (or 1 feet); - maximum range: about 40 meters (or 100 feet). Operative mode: single line (2 wires), Crosstalk (4 Wire), Differential by relative comparison with other line; Monitoring to events localization by Peak mode (Sample & Hold). Pulse output level: short and long: 2.2 Vpp; Boost: 5.5 Vpp. Pulse length: automatic on range selection, from 10 to 5000 ns.; IN/OUT impedance: 100, 110, 120, 135, 150 Ω (balanced). TGC (automatic gain control): 0 6 db/km. Propagation velocity: PVF 0.300 to 0.999 or PV or V/2 (90 to 300 m/µs). Digital Multimeter DC / AC (by DMM optional module) Measuring mode: automatic between a-b; a-c (Gnd); b-c (Gnd) and reverse. DC Voltage, Range / Accuracy: 0 140 Vdc / 2% of reading ±1 digit. AC Voltage, Range / Accuracy: 0 100 Vrms / 2% of reading ±1 digit (from 30 Hz up to 1kHz). RESISTANCE / INSULATION - Test Voltage: 100 Vdc (with current limitation 1mA max). - Range / Accuracy: 5 Ω 1 GΩ /: 2% of reading ± digit. LINE LENGTH BY LOOP RESISTANCE - Line length evaluation: (as function of measured resistance) - Line Gauges setting: from 0.4 to 0.9 mm or from AWG 26 to AWG 19. - Line Resistance correction: from 1.0 to 1.60 x standard copper resist. - Line Temperature setting: set from -20 +60 C. - Range / Resolution: 0 to 99.999 kunits (meters or feet) / 1 units. DC CAPACITANCE (time of DC discharge method) - Test Voltage: 100 Vdc - Range / Accuracy: > 10 nf 10 µf / 5% of reading ± 1 digit. AC CAPACITANCE (by capacitive bridge) Measuring mode: by 1 khz tone 1.1 Vpp between a-b wires. Range / Resolution: 0.1 to 3000 nf / 0.1 nf. Accuracy: ± 1% of reading ± 1 nf @ C <500 nf; ± 5% of reading ± 1 digit @ C >500 nf and < 3000 nf. LINE LENGTH BY CAPACITANCE Line length estimation: (as function of measured capacitance): Line Capacitance setup: 10.0 to 300.0 pf / Length Unit. Range / Resolution / Accuracy: 1 to 99999 Units (m. or ft.) / 1 units / as derived from measured capacitance. RFL (RESISTANCE FAULT LOCATOR) - Loop resistance: 1Ω to 5 kω maximum. - Fault resistance: from 100 Ω to 20 MΩ maximum. - Accuracy of RTF @ 1 M.: ± 0.5% of Loop resistance. - Readout : graphic representation and action help. RBAL (Resistance Balancement): starting from 5 Ω up to 99%. Readout : graphic representation and action help. IMPEDANCE RESPONSE - Impedance Range: 30 3200 Ω in five steps - Frequency Range 50 Hz 5.0 MHz in four steps - Accuracy: ±5 % ±5 Ω POTS Subscriber Simulator (by optional module on DMM module) Dial Encoder: - Pulse, programmable on duration/ratio (default 100 ms / 40/60%); - DTMF std. tones, programmable on Level, Duration, Inter-tone. Ring Detect. Range & Meas: Level: 10 90 Vrms; Frequency: 15 70 Hz. Ring Detector AC Load: R 7310 Ω ± 2% in series + 940nF ±10% capacitor. Ring current self limitation: 15 ma peak ; safety fold-back limited. On Hook / Break & Make specs.: R=120 Ω ±2% @ I = 100 ma; Voffset = 4 Vdc. Automatic Single End Line Test for line pre-qualification * With single ACT6000 on open lines, 2 or [4] Wire mode: Metallics: AC / DC Voltage, DC Insulation, AC Capacitance, Q, / DC Capacitance, End-Of-Line (by TDR trace). Transmissives (Wide band): Noise (local), Return-Loss, Longitudinal Balance-Loss, FDR Insertion-loss & frequency response estimation, Farend Noise (estimation), SNR prediction, ADSL - ADSL2+ and VDSL 1 / 2 ***, Bit-Rate prediction, [NEXT]. Automatic End-to-End Test for line qualification * With two ACT6000 (Master/Slave configuration) for Double-End Tests, 2 or [4] Wire mode: Only Transmissives (base and wide band): Noise (bilateral), Return-Loss (bilateral), Longitudinal Balance-Loss (bilateral LCTL ), Insertion-Loss, SNR (bilateral), ADSL - ADSL2+ and VDSL*** Bit-Rate evaluation (Up & Down stream), [NEXT and FEXT]. Masks for pre-configured SELT or DELT line tests * Wide band: VOICE, ISDN, HDSL 1p, HDSL 2p, E1, T1, SHDSL, ADSL, ADSL2+ and VDSL2-12, 17, 30. Masks for pre-configured DELT telephone tests ** Base band: M1040, M1020, G.712E2, EURO16k, EURO32k, MIL16k, MIL32k DBPO Masks - Automatic generation of the Threshold Mask related to the true primary line parameters included the ESEL measured by ADSL2+ SELT Sequence. Notes: * by adoption of the Advanced Software 1/II ** by adoption of the Advanced Software 2.0 (to be develop) *** by adoption of EBM 30 optional module Supplied Accessories (base kit): ACT6000 Base Instrument, included: - Nylon Carrying Case with pocket for accessories; - User Guide (English or Italian language, as requested); - AC Power Supply and Battery Charger (Line Input: 100-220 Vac; Output: 20 Vdc; 1.4A); - Banana-Banana + Crocodiles shielded cables (2.30m total length); - Ground Cable unipolar Banana-Crocodile cable; Extra cost available Accessories and Optional Modules - ASW-1/II - Advanced Software (see the above description/ ref *). It allows also the use of the specific PC Utility program (windows compatible) to SW Update, Capture Screen, CSV file download, Cable data-base and Threshold Limits Editor etc.. - ACT-11 POTS Module (Subscriber Simulator Module for POTS for signalling tests), it requires the DMM module installed; - ACT-12 DMM Module (Digital Multimeter Module for metallic tests); - ACT-13 EBM30 Module (Extension Band Module for 30 MHz operation); - ACT-14 USB Pen-Drive 4 GB; - ACT-15 Probes to perform Medium & High Band PSD measurement on lines fed; - ACT-17-B 50 db Balanced Attenuator High Z input / 150 Ohm output. - ACT-17-U 50 db Unbalanced Attenuator High Z input / 75 Ohm output. - ALT-05 Headset with 2m cable and RJ-45/4 connector; it requires the POTS module installed. - ALT-09 Resistive Termination Set (100, 120, 135, 150 and 600 ); - ALT-16 Banana to BNC Adapter.