Dynatel 965DSP / 3M Far-End-Device Setup

Similar documents
Far End Device II Model 1342

3M Dynatel Far-End Device (FED II) Applications

3M Dynatel Far End Device III

Dynatel 900 Series Subscriber Loop Test Sets

3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance

T-BERD /MTS-4000 Multiple Services Test Platform Copper Services Module

A C T Advanced Communication Tester

Dynatel Advanced Modular System 965AMS

990DSL. Users Guide. CopperPro Loop Tester. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com

AXS-200/ MHz COPPER TEST SET

Complimentary Reference Material

Acterna DSL-311 and DSL-322 DSL Copper Testers

Dynatel TM APICS III Pair Identification Hookups, Procedures & Techniques. Dynatel

3M Dynatel. Advanced Modular System 965AMS. Future proof. testing platform

AXS-200/ MHz COPPER TEST SET. part of the SharpTESTER Access Line. Telecom Test and Measurement

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Application Series. SunSet xdsl: TDR Testing Techniques for DSL Circuits

3M Dynatel Advanced Modular System 965AMS. Now. You Know. Sold by: Toll Free: (877)

Copper Lines and High Speed

A C T Advanced Communication Tester

Dynatel TM 900/900M Series Test Set

VIAVI ONX 580. Technical Assistance: GO-VIAVI;

ACT6000 Advanced Communication Tester

Resistive Fault Location Methods REFERENCE GUIDE

A C T Advanced Communication Tester

HT1000/2 Series Copper Wire Analyser

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

MaxTester 610 KEY FEATURES AND BENEFITS THE MAXTESTER 600 SERIES SPEC SHEET SMARTER COPPER TESTING FOR INSTALLATION TECHNICIANS

20Hz to 2.2MHz Transmissive Measurements

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

QUICK REFERENCE GUIDE

Specification PTC 281: Telecom Requirements for Customer-connected

Requirements and Test Methods for Very-High-Bit-Rate Digital Subscriber Line (VDSL) Terminal Equipment

SFRA45 QUICK MEASUREMENT GUIDE

Test Equipment Solutions Datasheet

Dynatel 2250E/2273E Advanced Cable and Fault Locator

Opternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)

CopperPro Series II. The complete test set for qualifying your local loop for ADSL, VDSL and special services.

Opternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)

CopperPro Series II. Fluke Networks Copper Pro Series II Specs Provided by

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Installation, Operation and Maintenance Manual

Part V: Requirements and Test Methods for Magnetic Output from Handset Telephones for Hearing Aid Coupling

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

3M Dynatel Triple Play Customer Service Test Set INS970

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Basic Transceiver tests with the 8800S

COMMITTEE T1 TELECOMMUNICATIONS. Plano, Texas; 2 December 1998 CONTRIBUTION

JDSU Presents The Cause and Effects of Bonding and Grounding on xdsl IPTV Services February 12 th, 2009

Application Note. High Impedance Drivers During Power Failure Using XRT83SL3X/L3X LIU

DEC-001 Installation Instructions

APX Mobile and Portable Automated Test and Alignment

OPERATING MANUAL TRANSMISSION TEST SET 806A / 806AR

Demo / Application Guide for DSA815(-TG) / DSA1000 Series

Obsolete Document. Dynatel

AC Clamp Meter + Phase Rotation Tester

Specification CPE MASTER SPLITTER ADSL ASYMMETRIC DIGITAL SUBSCRIBER LINE. Figure 1

Power Supply Rejection Ratio Measurement

Part V: Requirements and Test Methods for Magnetic Output from Handset Telephones for Hearing Aid Coupling and for Receive Volume Control

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

PagePac Plus AmpliCenter V /V /V

User s Guide. 400A AC/DC Clamp Meter. Model MA220

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

Hands On Relay School 2017

Fluke Clamp Meters Solutions for every need

ALX-SSB 5 Band Filter Assembly Manual 19 November 2018

Technical Application Note #3

Studio Broadcast System

Product Specification File

1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C

4 Power Sources External DC. supply Battery Charging Maximising Battery Life 11

Not for Reproduction

360mm (14-3/16 ) x 224mm (8-13/16 ) x 67mm (2-5/8 )

User manual Ascom SE550 Transceiver

Appendix C: IFR 3920 Test Procedures MAINTENANCE GUIDE.

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

12 CHANNEL HI-LEVEL TO RCA SUMMING CONVERTOR BLUELINE FLATLINE II

Class D Topology IR2110S S/N 87dB at 1 ohm All "N" Channel MOSFET TO218 Transistors Unregulated Power Supply 140 Volt Rails +/- for INSANE

Installation and maintenance

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

Silvertel. Ag1110 LOW COST SLIC

Cable Fault Location System User Manual Version 1.0.4

TOSHIBA INTERNATIONAL CORPORATION. Magmeter Quick Start Guide

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

EE 451 FINAL SENIOR PROJECT PROPOSAL. Microcontroller-Based Remote Locator Using Asynchronous Serial Communication

400Amp True RMS AC Clamp Meter + NCV

Property of Ramsey Electronics, Inc. Do not reproduce or distribute.

Fluke 125. Getting Started. Industrial ScopeMeter

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

BFoxCon Manual. Version 0.2 October 30, 2017

FTB-610 Wideband Copper Test Module

Copper Loop Frequency Management Plan

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

DSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.

ETSI TR V1.1.1 ( )

Description, operating instructions and hardware specification of the HL Transverse balance measurement module (TBMM).

Transcription:

Dynatel 965DSP / 3M Far-End-Device Setup For Line Qualification Testing ( Voiceband & Wideband Digital Services ) Welcome Dynatel TM 965DSP Subscriber Loop Analyzer S/N 9751YP w 1998 3M Ver 5..4 USA Setup Help Dynatel TM 965DSP On Off On Off V ABC ma 1 2 3 GHI JKL MNO 4 5 6 DSL DEF PQRS TUV WXYZ 7 8 9 Ins Del Model 1332 Far End Device db Auto Prepared By: Roger C. Valencia U.S. & International Technical Service Engineer 3M Test & Measurement Systems 3M Austin Center Austin, TX, USA - January 21 1

965 DSP Requirement for Wideband Auto Tests! Ver. 5..2 or higher Make sure the 965 DSP test set has the proper software version. If it does not, contact Repair Service to get it upgraded. 2

Pair Testing/Qualification for New Wideband Services Who does the Testing? How is the testing done? What are the Procedures? 3

Generic Procedures for Testing an to Support Wideband Services Type of Test Volts DC Ohms Capacitance Load Coils Conductor Continuity Insertion Loss Slope TDR Looking for Crossed Battery Insulation Resistance (failures) Pair Length - Are Tip & Ring length equal? Presence of Load Coils and Where Loop Resistance Tip/Ring Resistance Balance Resistance Difference between the two Circuit Loss on a single tone only Losses at Prescribed Stepped Tones Bridge Taps Overall Electrical Balance (Resistance and Capacitance) Opens, Bridge Taps and Loads 4

Manual Pair Testing to Support Wideband Services Using the Dynatel 965DSP only. (without or Smart Strap) Type of Test Volts DC Ohms Length (Capacitance) Load Coils Special Resistance Wideband Loss Slope Wideband Loss TDR Looking for Crossed Battery Insulation Resistance (failures) Pair Length - Are Tip & Ring equal? Presence of Load Coils and Where Loop Resistance and Tip/Ring Resistance Balance Circuit Loss on a Single Tone only Losses at Prescribed Stepped Tones Bridge Taps Opens, Bridge Taps and Loads 5

Automatic Pair Testing to Support Wideband Services Using the Dynatel 965DSP and or Smart Strap Type of Test Volts DC Ohms Length (Capacitance) Load Coils Special Resistance Wideband Loss Slope (Sweep) Wideband Loss Looking for Crossed Battery Insulation Failures Pair Length - Are Tip & Ring equal? Presence of Load Coils and Where Loop Resistance Tip/Ring Resistance Balance Resistance Difference between the two Circuit Loss on a Single Tone only Losses at Prescribed Step Tones Bridge Taps Over all Electrical Balance of pair (Capacitance & Resistance) 6

Wideband Auto Test Routines (With FED Only) time 2 min. Voltage Ohms (Insulation) Opens (Capacitance Length) Capacitance Balance Loop Resistance Load Coil and Location Loss Time 4 min. Voltage Ohms (Insulation) Opens (Capacitance Length) Capacitance Balance Loop Resistance Load Coil and Location Loss Slope (Step Tones) Resistance Balance 7

Tone & Loss Requirements Circuit Qualification Typical Loss Type Frequency Specification Inactive POTS 14 Hz >-8.5 dbm Rate ISDN 4K Hz >-34 dbm HDSL 196K Hz >-36 dbm Primary Rate ISDN & T1 772K Hz >-15 dbm ADSL Up stream 138K Hz >-38 dbm Down stream 12K Hz (1.2M Hz) >-32 dbm 8

3M Far End Device What does it do? Model 1332 Far End Device 965DSP 1. It can send an ID tone to identify a pair to be tested. To do this, press the the ON key twice during turn ON, the FED will transmit an ID tone through the pair. 2. It sends the appropriate single or steps tones (Voiceband and Wideband sweep frequencies) for circuit loss measurements as instructed by the 965DSP. 3. It serves as a remote switch to strap (connect to) or un-strap (disconnect from) Shield/Ground, the Tip(A) and Ring(B) conductors as instructed by the 965DSP for Loop Resistance and Resistance Balance measurements. 9

965DSP / Hookup [ VoiceBand & Wideband Line Qualification Test ] Near-end Far-end Ring [A] Tip [B] Model 1332 Far End Device Shield/Ground Dynatel 965DSP 3M FED 1

ON OFF Welcome Dynatel TM 965DSP Subscriber Loop Analyzer Setup On Off To turn unit ON S/N 9751YP w c 1998 3M Ver 5..4 USA Help Auto To go to Auto Menu Autotest Setup with This screen OR This screen AUTO Auto Menu Active Pair POTS FED Setup Inactive Setup 24 AWG FED= ne Start ne FED Setup SmartStrap TM Accept 3 4 5 AUTO RING GND TIP ne FED Setup SmartStrap TM To do FED Setup To highlight/select To accept option Auto Menu Active Pair Wideband Test POTS FED Setup Inactive Setup 22 AWG Start 6 7 8 To highlight/select Inactive Setup Calibrated Cable Custom Cable Test To initiate Inactive Setup Service Gauge 22 AWG 24 AWG Inactive Setup Calibrated Cable Custom Cable Test Select To select type of cable () AUTO RING GND TIP Auto Menu Active Pair Wideband Test POTS Service Gauge 19 AWG 22 AWG Accept 9 1 To move to the Test Choice box 24 AWG Inactive Setup Calibrated Cable Custom Cable Test AUTO db 1 3 5 Select To select Test 11 db db Accept Service Gauge 19 AWG 22 AWG Accept To move to the Gauge box Vdc ft 965DSP Select Accept FED Setup Inactive Setup Start 12 To select wire gauge 13 14 To accept selections Double-check if selected options are correct To start Auto Test Test Results Screen 11

ON OFF Welcome Dynatel TM 965DSP Subscriber Loop Analyzer S/N 9751YP w c 1998 3M Ver 5..4 USA This screen OR AUTO Auto Menu Active Pair POTS FED Setup Inactive Setup 24 AWG FED= ne Start 3 4 ne FED Setup SmartStrap TM Accept FED Setup SmartStrap TM To do FED Setup To highlight/select To accept option 5 ne Accept 965DSP Setup 1 2 On Off To turn unit ON Help Auto To go to Auto Menu This screen Autotest Setup Wideband Pair QualificationTesting AUTO RING GND TIP Auto Menu Active Pair Wideband Test T1 FED Setup Wideband Setup Custom Cable Test Choice Gauge 22 AWG 24 AWG Select Wideband Setup 24 AWG Start Service ISDN HDSL T1 E1 Accept 6 7 8 To highlight/select Wideband Test 12 To initiate Wideband Setup Custom Cable Test Choice Gauge 22 AWG 24 AWG Select To select type of cable Custom Cable Test Choice Gauge 22 AWG 24 AWG Select Wideband Setup Service HDSL T1 E1 ADSL Accept Wideband Setup Service HDSL T1 E1 ADSL Accept 9 1 To move to the Test Choice box Custom Cable Test Choice Gauge 22 AWG 24 AWG AUTO RING GND TIP Select To select test Wideband Setup Auto Menu Active Pair Wideband Test ADSL 13 14 15 16 FED Setup Wideband Setup Service HDSL T1 E1 ADSL 11 Accept To move to the Gauge box 24 AWG Start To select wire gauge To move to the Service box To select type of service To accept selections To start Wideband Auto Test 12

VoiceBand Or Wideband Line Qualification Test Procedure Dynatel 965DSP Near-End Far-End Model 1332 Ring [A] Tip [B] ID Tone Shield/Ground 1. Connect the to the pair under test at the subscriber end, as shown above. If the pair under test has not been previously identified, proceed to the next step. If the pair under test has been previously identified, proceed to step # 4. On 2. Press the ON/Off button twice Off to activate the Pair ID tone. The FED will then send ID tone to the other end of the cable. 3. At the test set end, trace the ID tone on the pair using the 965DSP db Loss function or an ID tone Probe/Amplifier. 4. Once the pair is identified, press the AUTO key Auto to go to the Auto Menu screen. 5. On the Auto Menu screen, select the type of test to be performed which requires the use of a. 13

Wideband Auto Test Results Pass/Fail Numeric Value Transmission te: Press to store Test Results Graphics View of Slope 14

Auto Test Screen Icons Voltage Insulation Ohms Opens Length Load Coil Detect/Distance Loop Resistance Resistance Balance Capacitance Balance Loss/Slope 15

Wideband Printed Auto Test Results ADSL HDSL 16

Test [without FED] Test Pass/Fail Vdc Ohms Opens Load Coil Test [with FED] Test Pass/Fail Vdc Ohms Opens Voiceband Sweep Single Tone Loss Loop Resistance Load Coil 17

Active Pair Test [no FED required] Test Vdc Loop Current Loss ise Power Influence Pass/Fail Wideband Test [FED required] Test Pass/Fail Vdc Ohms Opens Capacitance Balance Sweep Loss Single Tone Loss Loop Resistance Resistance Balance Load Coil 18

Service Type POTS Inactive & Wideband Loss Test Frequencies Single Freq. (khz) 14 (Hz) Sweep Freq. (khz) 44, 84, 14, 124, 144, 164, 184, 24, 284, 34 (Hz) 56 kb 28 2. 28, 32, 4, 48, 82 64 kb 32 2, 28, 32, 4, 48, 82 * te: Tests for these service types are not available on some of the older versions of the 965DSP. Upgrades are available thru 3M Telecom Repair Service, Call 1-8- 426-8688 ISDN HDSL T1* E1* ADSL 4 196 772 124 138 11 2, 28, 32, 4, 48, 6, 7, 82 2, 3, 5, 7, 9, 11, 13, 196, 4* 2, 4, 5, 7, 772, 124 2, 4, 5, 7, 772, 124 2, 3, 5, 69, 9, 11, 138, 276, 4, 6, 8, 1, 11 19

Autotest Editable Threshold Parameters Insulation Loss Slope Loop Resistance Active Pair Loop Current Loss ise Power Influence Balance Wideband Insulation Capacitance Length Capacitance Balance Loss Loop Resistance Resistance Balance 2