WE5-HJ8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HR 59 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 59 Nominal data Type Motor WE5-HJ8- ME68-DF Phase ~ ~ Nominal voltage VC Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min - 6 85 Power input W 5 6 Current draw.5.7 Motor capacitor µf.5.5 Capacitor voltage VDB Capacitor standard P (CE) P (CE) Max. back pressure Pa 5 Min. ambient temperature C -5-5 Max. ambient temperature C 7 55 ml = max. load me = max. efficiency fa = running at free air cs = customer specs cu = customer unit Subject to alterations Data according to ErP directive Installation category Efficiency category Static Variable speed drive No Specific ratio *. * Specific ratio = + p fs / Pa ctual Request Request 5 Overall efficiency η es 5. 8. Efficiency grade N 6.9 6 Power input P e kw. ir flow q v m³/h 6 Pressure increase p fs Pa Speed n min - Data established at point of optimum efficiency Item no. 7-5-998 Revision - Release -- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
WE5-HJ8- Technical features Mass Size Surface of rotor Material of blades Material of wall ring Number of blades 7 Direction of air flow Direction of rotation. kg 5 mm Coated in black Sheet steel, coated in black Die-cast aluminium "V" Type of protection IP Insulation class Humidity class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 699 (measuring network Fig., TN system) Electrical leads Motor protection Cable exit Protection class Product conforming to standard pproval Counter-clockwise, seen on rotor "B" F + 8 C - C ny None S Ball bearing <.75 m Via terminal strips, integrated capacitor connected via terminal strips Thermal overload protector (TOP) wired internally Variable I (if protective earth is connected by customer) EN 65-; CE UL ; CS C. Nr.77 Item no. 7-5-998 Revision - Release -- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
WE5-HJ8- Product drawing Direction of air flow "V" Connection screen U blue Z brown U black PE green/yellow Item no. 7-5-998 Revision - Release -- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
WE5-HJ8- Charts: ir flow 5 Hz Druck p f s[pa]für Rho=,kg/m^ qv[cfm] 6 8..,85,8 9 8 7 6 5,75,7,65,6,55,5,5, pfs_e[in HO] Measurement: LU-9 ir performance measured as per ISO 58 Installation category. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: Lw measured as per ISO 7 / Lp measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 9 8 7 6,5,,5 5,,5, 6 8.. qv[m^/h]..6.8.,5. Measured values U V f Hz 5 5 5 5 n min - 6 55 85 P e W 5 I.5.5.57.6 qv m /h 885 7 9 5 p fs Pa 8 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = ir flow p fs = Pressure increase Item no. 7-5-998 Revision - Release -- Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
WE5-HJ8- Charts: ir flow 6 Hz Druck p f s[pa]für Rho=,kg/m^ 9 85 8 75 7 65 6 55 5 5 5 5 5 5 95 9 85 8 75 7 65 6 55 5 5 5 5 5 5 6 8 6. qv[cfm] 8.. qv[m^/h]..6.8....,76,7,7,7,68,66,6,6,6,58,56,5,5,5,8,6,,,,8,6,,,,8,6,,,,8,6,,,,8,6,,. pfs_e[in HO] Measurement: LU-9 ir performance measured as per ISO 58 Installation category. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: Lw measured as per ISO 7 / Lp measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V f Hz 6 6 6 6 n min - 85 7 585 P e W 6 67 76 8 I.7.7.76.8 qv m /h 85 585 5 p fs Pa 8 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = ir flow p fs = Pressure increase Item no. 7-5-998 Revision - Release -- Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com