Applications EE2-3 S NU -L. Series Coil Voltage Latch Type Lead Type Packaging EC2- = Through-hole mount EE2- = Surface mount

Similar documents
Applications EF2-3 NU -L. Series Coil Voltage Latch Type Lead Type Packaging ED2- = Through-hole mount EF2- = Surface mount

Applications EB2-3 S NU -L. Series Coil Voltage Latch Type Lead Type Packaging EA2- = Through-hole mount EB2- = Surface mount

Applications UD2-3 S NU -L. Series Coil Voltage Latch Type Lead Type Packaging UC2- = Through-hole mount UD2- = Surface mount

Applications SCF Type Dimension Code (See Table 1) Rated Current (A) Minimum Inductance (mh)

DATA SHEET. Ultra-low power, compact and lightweight, High breakdown voltage, Surface mounting type

DATA SHEET COMPACT AND LIGHT WEIGHT SURFACE MOUNTING TYPE

Applications SS 30 V- R

Applications SU 10 VFC- R

Applications SU 16 VD

Applications SC JH

DATA SHEET COMPACT SIZE, SLIM-PACKAGE. NEC TOKIN EC2/EE2 relay is a standard miniature signal relay, compact and slim.

Applications SCR R55 A250 JH

Overview. Applications. Benefits. Ordering Information. Sensors High Alternating Current Sensors, Snap-on Type

EMI Core ESD-SR-H/HL Series Snap-on Cores for Round Cables with High Heat Resistance and Cable Holding Mechanism

EMI Core ESD-FPD-1 Series Split Cores with Plastic Clamp for Flat Cables. Split construction Nylon clamp

MPLCH 0740 L 1R0. Series Size L x W (mm) Inductor Inductance Code µh MPLCH

EMI Core ESD-R-H Series Toroidal Cores for Round Cables with High Heat Resistance and Cable Holding Mechanism

MINIATURE SIGNAL RELAY MR62 SERIES

Applications PHZ9004 E F 7100 M R06L2

Snap-on convenience Split construction Temperature Index of 65 C Meets the requirements of UL94V-0 CTI: Rank 0 Broad range by simply adding turns

AC Line EMI Suppression and RC Networks PMZ2035 Series Metallized Impregnated Paper, Class X1, 440 VAC/1,000 VDC. Applications

Applications. Overview. Benefits. Part Number System. AC Motor Start Aluminum Electrolytic Capacitors MS/MD Series, +60ºC/+70 C

Applications PMR210 M B 5220 M 100 R30

Overview. Benefits. Applications. Tantalum Polymer Hermetic Sealed/Axial Through-Hole Capacitors T550 Polymer Hermetic Seal (PHS) Series

Overview. Applications. Benefits SPICE. Tantalum Polymer Hermetic Sealed/Axial Through-Hole Capacitors T550 Polymer Hermetic Seal (PHS) Series

Applications. Overview. Benefits. Part Number System. Axial Aluminum Electrolytic Capacitors PEG225 Series, +125ºC and +150ºC

AC Line EMI Suppression and RC Networks PME271Y A E Series Metallized Impregnated Paper, Class Y2, 300 VAC. Applications

Applications. digits of the capacitance value. First digit indicates the total number of digits in the capacitance value.

Applications PHE448 R B 4150 J R06

Overview. Benefits. Applications. Tantalum Through-Hole Capacitors Hermetically Sealed T550 Axial Polymer Hermetic Seal (PHS) 105ºC and DLA Series

Applications SS 30 V- R

Applications SS 26 V- R

Applications SS 30 V- R

Applications SS 26 V- R

One WORLD One Brand One Strategy One Focus One Team One KEMET

Polypropylene Pulse/High Frequency Capacitors R79 Series Single Metallized Polypropylene Film, Radial, 5 mm Lead Spacing, Multipurpose Applications

General Purpose Metallized Polyester Film Capacitors R82 Series, Radial, 5 mm Lead Spacing, VDC (Automotive Grade) Applications

High switching capacity 1a/1c 30A power relays

Overview. Applications. Benefits. Legacy Part Number System. New KEMET Part Number System

SPECIFICATIONS Contact Form 2 Form C Maximum switching power 30 W (resistive) 62.5 VA (resistive) Contact Ratings Maximum switching voltage 220

Applications. Overview. Benefits. Ordering Information. Pulse Transformers Device for HD-PLC, PLT Series

Applications SC JS. Series Rated Current AC (A) Inductance (mh) Minimum Terminal Base Type 0x- = x A. x0 = x mh xx = x.x mh 0x = 0.

Applications FR 0H 104 Z F

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Applications. Capacitance Code (pf) First two digits represent significant figures. Third digit specifies number of zeros.

Overview. Benefits. Applications. Turns and Impedance Characteristics. Core Material and Effective Frequency Range

Applications SS 35 V

Applications. Capacitance Code (pf)

MINIATURE SIGNAL RELAYS

Applications SS 26 V- R

Applications SC JH. Series Rated Current AC (A) Inductance (mh) Minimum Terminal Base Type x0- = x0 A xx- = xx A. x0 = x mh xx = x.

Slim compact safety relay

LOW-PROFILE SURFACE-MOUNT RELAY

Polypropylene Pulse/High Frequency Capacitors R79 Series Single Metallized Polypropylene Film, Radial, 5 mm Lead Spacing, Multipurpose Applications

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

C 062 C 105 K 1 R 5 T A Rated Voltage (VDC) 5 = 50 1 = = 200

Applications SSHB 10 HS- R Core Type

Applications SSR 21N VS Core Orientation and Bobbin Type

Applications SS 11 VL- R


Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Applications. Overview. Benefits. Part Number System. AC Line Filters Common Mode SSRH Coils, 24NVS/NHS, Wide Range Impedance Type

Tantalum Surface Mount Capacitors Standard Tantalum T488 Series Small Case Size Substrate Terminal MnO 2

Applications R74 5 F 1100 AA H0 J

Applications SS 30 V- R

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

Applications SSR 10 V Core Orientation and Bobbin Type

Surface Mount Polyester (PET) Film Capacitor JSN, Unencapsulated Stacked Chip with Flat Terminations, VDC, for DC Link (Automotive Grade)

Designed for mission critical applications requiring high power, filtering, hold-up and current pulse generation.

HIGH INSULATION RELAYS (Conforming to the supplementary insulation class of EN Standards (EN41003))

Applications SSR 21N V-M Core Orientation and Bobbin Type

Applications SSHB 21 HS- R Core Type

High breakdown voltage type is available (1.5 kv between open contacts)

SLIM COMPACT SAFETY RELAY

Compact Relay Family with Forcibly Guided Contacts

ULTRA LOW PROFILE 2 AMP. POLARIZED RELAY. mm inch. Initial breakdown voltage

Applications SSRH 7 HS-M Core Orientation and Bobbin Type

Applications SU 9 VD

2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage

Overview. Applications. Benefits. Legacy Part Number System. New KEMET Part Number System

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

MPLCH 0740 L 1R0. Series Size Code Inductor Inductance Code µh MPLCH

High Sensitivity, with 100mW nominal operating power, in a compact and space saving case

Overview. Benefits. Applications. Tantalum Through-Hole Capacitors Radial Dipped T363 & T369 MIL-PRF-49137/2 (CX02 & CX12 Style)

New pin layout (LT type) added. Best seller with broad lineup and AC 2000 V breakdown voltage.

Applications TPI L 180 N. Series Size Code Inductor Inductance Code nh Core Material TPI

Surface-mounting Relay

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

S C A 69 B 104 J W S. Capacitance Code (pf)

Type 167/184 Metallized Polyester Radial Lead Capacitors Radial Box Metallized Polyester Capacitors for Automatic Insertion

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

Overview. Benefits. Part Number System. Pin/Solder Tag/Audio Aluminum Electrolytic Capacitors ALN20S Series, +85 C

Applications HHBC 8S- 0R6 A 0024 V. Wire Diameter (mm) Windings. R = Decimal point. A = Single B = Double

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

Compliant with European standards 1a/1c 6A Slim power relays

FTR-B4 Series ULTRA MINIATURE RELAY SLIM SIGNAL RELAY. RoHS Compliant FEATURES ORDERING INFORMATION

EMI Cores ESD-R-B Toroidal Cores for Round Cables for Low & High Frequency (with snail-shaped case) Applications

MINIATURE RELAY 2 POLES, 2A HIGH INSULATION/WIDE GAP FTR-C1 Series

KEMET Organic Capacitor (KO-CAP ) Miniature T527 Facedown Polymer Electrolytic (3216 Case Size)

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Transcription:

Miniature Signal Relays EC/EE Series Overview The KEMET EC/EE miniature signal relays offer a compact case size in a slim package. Minimal board space is consumed with either a through-hole or surface mount configuration. These relays are recognized by UL and CSA, while also being compliant with Part 68 of the FCC s,5 surge capacity. Applications Electronic switching systems PBX Terminal equipment Telephone systems Benefits Low power consumption (< mw) Compact and lightweight Low magnetic interference Tube or embossed tape and reel packaging UL recognized (E7366) and CSA certified (LR4666) Surface mount and through-hole options High Insulation (ND) type conforms to TU EN695 supplementary insulation class standards High Breakdown oltage (NKX) type can withstand.5 kac at open contacts Part Number System EE- 3 S NU -L Series Coil oltage Latch Type Lead Type Packaging EC- = Through-hole mount EE- = Surface mount 3 = 3 DC 4.5 = 4.5 DC 5 = 5 DC 9 = 9 DC = DC 4 = 4 DC Blank = Non-latch type S = Single coil latch type T = Double coil latch type NU = Standard NJ = Trimmed ND = High insulation NUH = Minimum footprint NUX = High solder joint reliability NKX = High breakdown voltage and high solder joint reliability Blank = Tube -L = Embossed tape on reel One world. One KEMET

Dimensions Millimeters EC Series Non-latch type and single coil latch type Double coil latch type D Maximum B Maximum D Maximum B Maximum H Maximum H Maximum.5 K.5.5 K.5 5.8 P P P 5.8 P P P P EE Series Non-latch type and single coil latch type Double coil latch type D Maximum B Maximum D Maximum B Maximum.5 H Maximum.5 H Maximum.5.5 5.8 P P K P 5.8 P P P K P 3 P P 3 Series D H B P P P 3 K EC (NU, ND) 5. 9.4 7.5.54 5.8 3. EC (NJ) 5. 9.4 7.5.54 5.8.8 EE (NU, ND) 5.. 7.5.54 5.8 9.5. EE (NUH) 5.. 7.5.54 5.8 7.5. EE (NUX, NKX) 5..35 7.5.54 5.8 9..35 General tolerance: ±.

Pin Configurations Bottom view Non-latch type (Non-energized position) 3 4 5 Single coil latch type (Reset position) 3 4 5 Double coil latch type (Reset position) 3 4 5 6 Direction mark + - Direction mark + - S R - + Direction mark + - + - 9 8 9 8 S: Coil polarity for Set R: Coil polarity for Reset 9 8 7 Set coil Reset coil Safety Standards and Ratings Certification Body Mark Specification File Number Rating UL CSA UL Recognized (UL58) CSA Certified (CSA. #4) E7366 LR4666 3 DC, A (resistive) DC,.3 A (resistive) 5 AC,.5 A (resistive) Spacing: UL4, UL478 Certification Body Mark Lead Type Specification File Number Class Rating TU ND (Non-latch and Single coil) NU, NJ, NUH, NUX (Non-latch and Single coil) TU Certified (IEC68 / EN68) TU Certified (EN68) R 97556 R 97553 Supplementary insulation Basic insulation Creepage and clearance of coil to contact is more than mm (According to EN695) Environmental Compliance All KEMET relays are RoHS Compliant. 3

Table Ratings & Part Number Reference Part Number Nominal Coil oltage Lead Type () To complete KEMET part number, leave blank for Non-latch, insert S for Single coil, or T for Double coil. Designates latch type. ND type only available as Non-latch and Single coil. NKX type only available as Non-latch. Non-standard part, please contact KEMET to special order. Packaging EC-3()NU 3 Radial Tube EC-4.5()NU 4.5 Radial Tube EC-5()NU 5 Radial Tube EC-9()NU 9 Radial Tube EC-()NU Radial Tube EC-4()NU 4 Radial Tube EC-3()NJ 3 Trimmed Radial Tube EC-4.5()NJ 4.5 Trimmed Radial Tube EC-5()NJ 5 Trimmed Radial Tube EC-9()NJ 9 Trimmed Radial Tube EC-()NJ Trimmed Radial Tube EC-4()NJ 4 Trimmed Radial Tube EC-3()ND 3 Radial, High insulation Tube EC-4.5()ND 4.5 Radial, High insulation Tube EC-5()ND 5 Radial, High insulation Tube EC-9()ND 9 Radial, High insulation Tube EC-()ND Radial, High insulation Tube EC-4()ND 4 Radial, High insulation Tube EE-3()NU 3 Surface mount Tube EE-4.5()NU 4.5 Surface mount Tube EE-5()NU 5 Surface mount Tube EE-9()NU 9 Surface mount Tube EE-()NU Surface mount Tube EE-4()NU 4 Surface mount Tube EE-3()NU-L 3 Surface mount Tape on Reel EE-4.5()NU-L 4.5 Surface mount Tape on Reel EE-5()NU-L 5 Surface mount Tape on Reel EE-9()NU-L 9 Surface mount Tape on Reel EE-()NU-L Surface mount Tape on Reel EE-4()NU-L 4 Surface mount Tape on Reel EE-3()NUH 3 Surface mount, Minimum footprint Tube EE-4.5()NUH 4.5 Surface mount, Minimum footprint Tube EE-5()NUH 5 Surface mount, Minimum footprint Tube EE-9()NUH 9 Surface mount, Minimum footprint Tube EE-()NUH Surface mount, Minimum footprint Tube EE-4()NUH 4 Surface mount, Minimum footprint Tube EE-3()NUH-L 3 Surface mount, Minimum footprint Tape on Reel EE-4.5()NUH-L 4.5 Surface mount, Minimum footprint Tape on Reel EE-5()NUH-L 5 Surface mount, Minimum footprint Tape on Reel EE-9()NUH-L 9 Surface mount, Minimum footprint Tape on Reel EE-()NUH-L Surface mount, Minimum footprint Tape on Reel EE-4()NUH-L 4 Surface mount, Minimum footprint Tape on Reel EE-3()NUX 3 Surface mount, High solder joint reliability Tube EE-4.5()NUX 4.5 Surface mount, High solder joint reliability Tube EE-5()NUX 5 Surface mount, High solder joint reliability Tube EE-9()NUX 9 Surface mount, High solder joint reliability Tube EE-()NUX Surface mount, High solder joint reliability Tube EE-4()NUX 4 Surface mount, High solder joint reliability Tube EE-3()NUX-L 3 Surface mount, High solder joint reliability Tape on Reel EE-4.5()NUX-L 4.5 Surface mount, High solder joint reliability Tape on Reel EE-5()NUX-L 5 Surface mount, High solder joint reliability Tape on Reel EE-9()NUX-L 9 Surface mount, High solder joint reliability Tape on Reel EE-()NUX-L Surface mount, High solder joint reliability Tape on Reel EE-4()NUX-L 4 Surface mount, High solder joint reliability Tape on Reel EE-3()ND 3 Surface mount, High insulation Tube EE-4.5()ND 4.5 Surface mount, High insulation Tube EE-5()ND 5 Surface mount, High insulation Tube EE-9()ND 9 Surface mount, High insulation Tube EE-()ND Surface mount, High insulation Tube EE-4()ND 4 Surface mount, High insulation Tube 4

Table Ratings & Part Number Reference cont d Part Number Nominal Coil oltage Lead Type () To complete KEMET part number, leave blank for Non-latch, insert S for Single coil, or T for Double coil. Designates latch type. ND type only available as Non-latch and Single coil. NKX type only available as Non-latch. Non-standard part, please contact KEMET to special order. Packaging EE-3()ND-L 3 Surface mount, High insulation Tape on Reel EE-4.5()ND-L 4.5 Surface mount, High insulation Tape on Reel EE-5()ND-L 5 Surface mount, High insulation Tape on Reel EE-9()ND-L 9 Surface mount, High insulation Tape on Reel EE-()ND-L Surface mount, High insulation Tape on Reel EE-4()ND-L 4 Surface mount, High insulation Tape on Reel EE-3NKX 3 Surface mount, High breakdown voltage, High solder joint reliability Tube EE-4.5NKX 4.5 Surface mount, High breakdown voltage, High solder joint reliability Tube EE-NKX Surface mount, High breakdown voltage, High solder joint reliability Tube EE-3NKX-L 3 Surface mount, High breakdown voltage, High solder joint reliability Tape on Reel EE-4.5NKX-L 4.5 Surface mount, High breakdown voltage, High solder joint reliability Tape on Reel EE-NKX-L Surface mount, High breakdown voltage, High solder joint reliability Tape on Reel Land Pattern Millimeters EC Series (bottom view) Non-latch type and single coil latch type.5 5.8.54.54 8 - ø.8.5.55.8.54 5.8.54.54.548 - ø.8 8 - ø.8 Double coil latch type.5 5.8.54.54.54.5 5.8.54.54.54 8 - ø.8 8 - ø.8..... EE Series (top view) Non-latch type and single coil latch type Double coil latch type.5.5 5.8.54 5.8.54.54.54.5 5.8.54.54.5.5 5.8.54.54.54 5.8.54.54.54 X X X... X X.. Series X EC 5.8 EE (NU, ND) 7.9 3. EE (NUH) 6.9. EE (NUX, NKX) 7..73 5

Soldering Process EC Through-hole Mounting Automatic Soldering Preheating: C / seconds (maximum) Solder temperature: 6 C maximum Solder time: 5 seconds maximum Note: KEMET recommends cooling down a printed circuit board to less than C within 4 seconds after soldering. Manual Soldering Solder temperature: 35 C maximum Solder time: 3 seconds maximum EE Surface Mounting IRS Method Temperature ( C) 8 Maximum 4 C 45 (Maximum 7) Time (seconds) 7 (Maximum ) 9 (Maximum 3) Note: Temperature profile shows printed circuit board surface temperature on the relay terminal portion. Please consult KEMET if you wish to use a temperature profile other than above. 6

Contact Specifications Contact Form Contact Material Contact Ratings Item Maximum Switching Power Maximum Switching oltage Maximum Switching Current Maximum Carrying Current Form C Silver alloy with gold alloy overlay 6 W, 5 A DC, 5 AC Minimum Contact Ratings mdc, µa * Initial Contact Resistance Operating Time (excluding bounce) Release Time (excluding bounce) Insulation Resistance Withstand oltage Shock Resistance ibration Resistance Ambient Temperature Coil Temperature Rise Running Specifications Weight Between Open Contacts EC/EE * This value is a reference value in the resistance load. Minimum capacity changes depending on the switching frequency, environment temperature, and load. * Rise time: µs; decay time to half crest: 6 µs. *3 Rise time: µs; decay time to half crest: µs. *4 This shows the number of operations with fatal defects. Stable characteristics are maintained for x 7 operations. A A 75 mω maximum (initial) Approximately milliseconds Approximately millisecond, MΩ @ 5 DC NU, NJ, ND, NUH, NUX:, AC (for one minute),,5 surge ( x 6 µs) * NKX: Make contact:,5 AC (for one minute),,5 surge ( x µs) *3 Break contact:, AC (for one minute),,5 surge ( x 6 µs) * Between Adjacent Contacts, AC (for one minute),,5 surge ( x 6 µs) * Between Coil and Contacts Non-load Load Non-latch and single coil latch type:,5 AC (for one minute),,5 surge ( x µs) *3 Double coil latch type:, AC (for one minute),,5 surge ( x 6 µs) * 735 m/s (75 G) misoperation 98 m/s ( G) destructive failure to 55 Hz, double amplitude 3 mm ( G) misoperation to 55 Hz, double amplitude 5 mm (3 G) destructive failure -4 to +85 C 8 C at nominal coil voltage (4 mw) x 8 operations (Non-latch type) *4 x 7 operations (Latch type) 5 DC. A (resistive), x 6 operations @ 85 C, 5 Hz DC ma (resistive), x 6 operations @ 85 C, Hz Approximately.9 g 7

Coil Specifications Nominal Coil oltage Test by pulse voltage. Coil Resistance (Ω) ±% Non-latch Type (@ C) Operating oltage Release oltage Nominal Operating Power (mw) 3 64.3.5.3 4 4.5 45 3.38.45 4 5 78 3.75.5 4 9 579 6.75.9 4 8 9.. 4 4 88 8..4 Nominal Coil oltage Test by pulse voltage. Coil Resistance (Ω) ±% Single Coil Latch Type (@ C) Set oltage Reset oltage Nominal Operating Power (mw) 3 9.5.5 4.5.5 3.38 3.38 5 5 3.75 3.75 9 8 6.75 6.75 44 9. 9. 4 384 8. 8. 5 Latch type relays should be initialized to a known position before using. Only the specified polarity should be used to energize the coil. Double Coil Latch Type (@ C),3 Nominal Coil oltage 3 4.5 5 9 4 Coil Resistance (Ω) ±% Set oltage 4 Release oltage 4 S 64.3.5 R 64.3.5 S 45 3.38 R 45 3.38 S 78 3.75 R 78 3.75 S 579 6.75 R 579 6.75 S 8 9. R 8 9. S 88 8. R 88 8. Nominal Operating Power (mw) 4 4 4 4 4 Latch type relays should be initialized to a known position before using. Only the specified polarity should be used to energize the coil. 3 Can not be driven by reverse polarity for reverse operation. 4 S = Set coil [pin # (+), pin # (-)], R = Reset coil [pin #6 (+), pin #7 (-)]. 8

Coil Specifications cont d Nominal Coil oltage Test by pulse voltage. Coil Resistance (Ω) ±% Non-latch, High Insulation (ND) Type (@ C) Operating oltage Release oltage Nominal Operating Power (mw) 3 45.5.3 4.5 3.38.45 5 5 3.75.5 9 45 6.75.9 7 9.. 4 54 8..4 3 Nominal Coil oltage Test by pulse voltage. Single Coil Latch, High Insulation (ND) Type (@ C) Coil Resistance (Ω) ±% Set oltage Reset oltage Nominal Operating Power (mw) 3 9.5.5 4.5 3 3.38 3.38 5 5 3.75 3.75 9 8 6.75 6.75 96 9. 9. 5 4 3388 8. 8. 7 Latch type relays should be initialized to a known position before using. Only the specified polarity should be used to energize the coil. Nominal Coil oltage Test by pulse voltage. Non-latch, High Breakdown oltage (NKX) Type (@ C) Coil Resistance (Ω) ±% Operating oltage Release oltage Nominal Operating Power (mw) 3 39..5.3 3 4.5 88. 3.38.45 3 66. 9.. 3 9

Recommended Relay Drive Conditions Coil Type Rating Ambient Temperature Non-latch Single Coil Double Coil oltage: ±5% of nominal voltage Square pulse (rise and fall time is rapid) Pulse height: ±5% of nominal voltage Pulse Width: > ms -4 to +85 C Marking Top view All except ND type: ND (High Insulation) type: Direction mark (pin No. and ) Part number E C -5N U UL, CSA marking Part number Direction mark (pin No. and ) E C -5N D TU, UL, CSA marki Manufacturer J A P A N 5 F Manufacturer J A P A N 5 F Country of origin Date code Country of origin Date code

Performance Data Coil Temperature Rise Temperature is measured by coil resistance Coil temperature rise ( ) 6 Coil temperature rise ( ) 3 Applied power.w 4 Applied power.4w Applied power.w 3 5 5 Applied power (mw) Applied time (minute) Switching Capacity Maximum alues Maximum Coil oltage Maximum value of permissible alteration. Contact current (A)..5. DC(Resistive) AC(Resistive). 5 Contact voltage () 5AC DC Ratio of nominal coil voltage (%) 5 5-4 - 4 6 8 Ambient temperature ( ) Applied oltage vs. Timing (Sample: EE-5NU) 4 4 (Without coil diode) 3 3 Operate time (ms) Release time (ms) 5 5 3 4 Applied power (mw) Applied power (mw)

Performance Data cont d Operate and Release oltage vs. Ambient Temperature This shows a typical change of operate (release) voltage. The value of must operate is estimated, so coil voltage must be applied higher than this value for safe operation. For hot start operation, please inquire with KEMET. 8 Must operate voltage Operate voltage (typical) Ratio of nominal coil voltage (%) 6 4 Release voltage (typical) -4-4 6 8 Ambient temperature ( C) Running Test (Non-load) (Load: none; Drive: 5 DC, 5 Hz, 5% duty; Ambient Temperature: room temperature; Sample: EE-5NU, pieces) 5 Contact resistance (mω) Operate 4 voltage 3 () Release voltage () 5 5 Operate voltage Release voltage 5 5 Operations ( 4 ) Operations ( 4 ) RUNNING TEST(Load) Running Test (Load) (Load: 5 DC,. A resistive; Drive: 5 DC, 5 Hz, 5% duty; Ambient Temperature: 85 C; Sample: EE-5NU, pieces) 5 4 Operate voltage Contact resistance (mω) Operate voltage () Release 3 Release voltage 5 5 Operations ( 4 ) 5 5 Operations ( 4 )

Performance Data cont d Breakdown oltage (Sample: EE-5NU, pieces) (a) Between open contacts (b) Between adjacent contacts Distribution 5 Distribution (%) 5.5..5. Breakdown voltage (K )..5..5 Breakdown voltage (K ) (C) Between coil and contact Distribution (%) 5.5.5..5 Breakdown voltage (K ) Alteration of oltage in Dense Mounting (magnetic interference) Ratio of alternation (%) +4 +3 + + - - -3-4 Alternation of operate voltage a b c d e f Ratio of alternation (%) +4 +3 + + - - -3-4 Alternation of operate voltage a b c d e f Mounting layout Mounting layout Device under test ON ON OFF OFF ON OFF.54 mm.54mm ON OFF a b c d.54 mm ON OFF ON OFF ON e OFF f 3

Tube Packing Millimeters 5.5 35 pieces / Tube (anti-static).9 Rubber stopper (Red) 543 Direction of relay direction mark Rubber stopper (Green) Tape & Reel Packaging Information (EE only) Millimeters Appearance Reel 5 pieces / Reel Reel diameter: 38mm Emboss Carrying tape Top cover tape Tape Dimensions max. A 8...75.4 Φ.5 6 4 Φ..5 4.7 5.5 4. Series A B NU-L, ND-L, NUX-L, NKX-L Maximum.9. NUH-L Maximum. 8.. B Relay Direction Mark and Tape Carrying Direction Sprocket hole Direction mark Direction of unreeling 4

Notes on Using Relays. Contact Load Make sure that the contact load is within the specified range; otherwise, the lifetime of the contacts will be shortened considerably. Note that the running performance shown is an example, and that it varies depending on parameters such as the type of load, switching frequency, driver circuit, and ambient temperature under the actual operating conditions.. Driving Relays If the internal connection diagram of a relay shows + and - symbols on the coil, apply the rated voltage to the relay in the specified direction. If a rippled DC current source is used, abnormalities such as heat at the coil may occur. The maximum voltage that can be applied to the coil of the relay varies depending on the ambient temperature. Generally, the higher the voltage applied to the coil, the shorter the operating time. Note, however, that high voltage also increases the bounce of the contacts and the contact opening and closing frequency, which may shorten the lifetime of the contacts. For consistent operation, the driving voltage should have rise and fall times of less than ms. Nominal coil voltage <msec. For a latching relay, apply a voltage to the coil according to the polarity specified in the internal connection diagram of the relay. If a current is applied to the coil over a long period of time, the coil temperature rises, promoting generation of organic gas inside the relay, which may result in faulty contacts. In this case, use of a latching relay is recommended. The operating time and release time indicate the time required for each contact to close after the voltage has been applied to or removed from the coil. However, because the relay has a mechanical structure, a bounce state exists at the end of the operating and release times. Furthermore, because additional time is required until the contact stabilizes after being in a high-resistance state, care must be taken when using the relay at high speeds. 3. Operating Environment <msec. Make sure that the relay mounted in the application set is used within the specified temperature range. Use of a relay at a temperature outside this range may adversely affect insulation or contact performance. If the relay is used for a long period of time in highly humid (RH 85% or higher) environment, moisture may be absorbed into the relay. This moisture may react with the NOx and SOx generated by glow discharges that occur when the contacts are opened or closed, producing nitric or sulfuric acid. If this happens, the acid produced may corrode the metallic parts of the relay, causing operational malfunction. If any material containing silicon (silicon rubber, silicon oil, and silicon based coating material) is used in the neighborhood of relay, there is some possibility that these materials will emit silicon gas that will penetrate the relay. In this case, the switching contact may generate silicon compounds on the surface of contacts. This silicon compound may result in contact failure. Avoid use of relay in such an environment. 5

Notes on Using Relays cont d Because the operating temperature range varies depending on the humidity, use the relay in the temperature range illustrated in the figure below. Prevent the relay from being frozen and avoid the generation of condensation. 85 8 Humidity (%RH) 6 4 The relay maintains constant sealability under normal atmospheric pressure (8 to, hpa). Its sealability may be degraded or the relay may be deformed and malfunction if it is used under barometric conditions exceeding the specified range. The same applies when the relay is stored or transported. Keep the upper-limit value of the temperature to which the relay is exposed after it is removed from the carton box to within 5 C. Permanent magnets are used in polarized relays. For this reason, when magnets, transformers, or speakers are located nearby the relay characteristics may change and faulty operations may result. If excessive vibration or shock is applied to the relay, it may malfunction and the contacts remain closed. ibration or shock applied to the relay during operation may cause considerable damage to or wearing of the contacts. Note that operation of a snap switch mounted close to the relay or shock due to the operation of magnetic solenoid may also cause malfunctioning. 4. Mounting When mounting a relay onto a PC board using an automatic chip mounter, if excessive force is applied to the cover of the relay when the relay is chucked or inserted, the cover may be damaged or the characteristics of the relay degraded. Keep the force applied to the relay to within kg. Avoid bending the pins to temporarily secure the relay to the PC board. Bending the pins may degrade sealability or adversely affect the internal mechanism. entilation immediately after soldering is recommended. Avoid immersing the relay in cleaning solvent immediately after soldering due to the danger of thermal shock being applied to the relay. Use an alcohol-based or water-based cleaning solvent. Never use thinner and benzene because they may damage the relay housing. Do not use ultrasonic cleaning because the vibration energy generated by the ultrasonic waves may cause the contacts to remain closed. 5. Handling and Storage 5-6 -4-4 6 8 Temperature ( C ) Relays are packaged in magazine cases for shipment. If a space is created in the case after some relays have been removed, be sure to insert a stopper to secure the remaining relays in the case. If relays are not well secured, vibration during transportation may cause malfunctioning of the contacts. Exercise care in handling the relay so as to avoid dropping it or allowing it to fall. Do not use a relay that has been dropped. If a relay drops from a workbench to the floor, a shock of 9,8 m/s (, G) or more is applied to the relay, possibly damaging its functions. Even if a light shock has been applied to the relay, thoroughly evaluate its operation before using it. 6

Notes on Using Relays cont d Latching relays are factory-set to reset state for shipment. A latching relay may be set, however, by vibration or shock applied while being transported. Be sure to forcibly reset the relay before using it in the application set. Also note that the relay may be set by unexpected vibration or shock when it is used in a portable set. The sealability of a surface mount (SMT) relay may be lost if the relay absorbs and is then heated during soldering. When storing relays, therefore, observe the following points:. For standard packing, please use relays within months after delivery (storage conditions: 3 C / 6% RH). If the relays have moisture absorption, dehumidify as follows: Tape Packaging: 5 ±5 C, 3 hours. Simple Relay: 85 ±5 C, 48 hours.. For MBB packing, please use relays within years after delivery (storage conditions: 3 C / 6% RH). After opening MBB packing, please use within 3 months (storage conditions: 3 C / 6% RH). 7

KEMET Corporation World Headquarters 835 KEMET Way Simpsonville, SC 968 Mailing Address: P.O. Box 598 Greenville, SC 966 www.kemet.com Tel: 864-963-63 Fax: 864-963-65 Corporate Offices Fort Lauderdale, FL Tel: 954-766-8 North America Southeast Lake Mary, FL Tel: 47-855-8886 Northeast Wilmington, MA Tel: 978-658-663 Central Novi, MI Tel: 48-994-3 West Milpitas, CA Tel: 48-433-995 Mexico Guadalajara, Jalisco Tel: 5-33-33-4 Europe Southern Europe Paris, France Tel: 33--4646-6 Sasso Marconi, Italy Tel: 39-5-939 Central Europe Landsberg, Germany Tel: 49-89-3358 Kamen, Germany Tel: 49-37-438 Northern Europe Bishop s Stortford, United Kingdom Tel: 44-79-46 Espoo, Finland Tel: 358-9-546-5 Asia Northeast Asia Hong Kong Tel: 85-35-68 Shenzhen, China Tel: 86-755-58-36 Beijing, China Tel: 86--589-7 Shanghai, China Tel: 86--6447-77 Taipei, Taiwan Tel: 886--758585 Southeast Asia Singapore Tel: 65-6586-9 Penang, Malaysia Tel: 6-4-643 Bangalore, India Tel: 9-86-53-7687 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. 8

Disclaimer This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin. All product specifications, statements, information and data (collectively, the Information ) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation s ( KEMET ) knowledge of typical operating conditions for such applications, but are not intended to constitute and KEMET specifically disclaims any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. 9