Electro-hydraulic Servo Valve Systems

Similar documents
INTERNATIONAL STANDARD

UNIVERSITY OF JORDAN Mechatronics Engineering Department Measurements & Control Lab Experiment no.1 DC Servo Motor

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Closed-Loop Speed Control, Proportional-Plus-Integral-Plus-Derivative Mode

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

Exercise 6. Open-Loop Speed Control EXERCISE OBJECTIVE

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

Automatic Control Systems 2017 Spring Semester

Omar E ROOD 1, Han-Sheng CHEN 2, Rodney L LARSON 3 And Richard F NOWAK 4 SUMMARY

4/3-way fast response valve Type 4WRGE

Servo Tuning. Dr. Rohan Munasinghe Department. of Electronic and Telecommunication Engineering University of Moratuwa. Thanks to Dr.

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

ON THE PERFORMANCE OF LINEAR AND ROTARY SERVO MOTORS IN SUB MICROMETRIC ACCURACY POSITIONING SYSTEMS

CONTROL SYSTEM COMPONENTS. M.D. Desai Professor of Instrumentation and Control Engineering Institute of Technology Nirma University Ahmedabad

Tuning of Controller for Electro-Hydraulic System Using Particle Swarm Optimization (PSO)

System Inputs, Physical Modeling, and Time & Frequency Domains

VARIABLE INDUCTANCE TRANSDUCER

Ch 5 Hardware Components for Automation

Motor Modeling and Position Control Lab 3 MAE 334

Application of AD698 Measuring Circuit in Valvistor Hydraulic Cartridge Valve

DC motor control using arduino

BSNL TTA Question Paper Control Systems Specialization 2007

Phys Lecture 5. Motors

Optimizing Performance Using Slotless Motors. Mark Holcomb, Celera Motion

Box chopper amplifier BOE

Advanced Servo Tuning

The Air Bearing Throughput Edge By Kevin McCarthy, Chief Technology Officer

Synchronous Machines Study Material

PART 2 - ACTUATORS. 6.0 Stepper Motors. 6.1 Principle of Operation

1. Explain in detail the constructional details and working of DC motor.


ACTUATORS AND SENSORS. Joint actuating system. Servomotors. Sensors

Closed-Loop Position Control, Proportional Mode

Single Ended Linear DC Servo Amplifier

Lecture 5 Introduction to control

GLOSSARY OF TERMS FOR PROCESS CONTROL

Uses an off-the shelf motor drive and menu-driven software. Magnet array on moving armature/ piston. Coil array on fixed stator/ cylinder.

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Shaft Torque Excitation Control for Drivetrain Bench

Ultrasonic. Advantages

LESSON 2: ELECTRONIC CONTROL

Penn State Erie, The Behrend College School of Engineering

Paul Schafbuch. Senior Research Engineer Fisher Controls International, Inc.

MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION WHEEL

Introduction to Measurement Systems

1. To study the influence of the gain on the transient response of a position servo. 2. To study the effect of velocity feedback.

SERVO VALVES. Maximum Flow. Maximum Operating Pressure MPa (PSI) U.S.GPM Page. Graphic Symbols.

APPLICATION NOTES G GENERAL PURPOSE P I D SERVOAMPLIFIER

LSV(H)G Series High-speed Linear Servo Valves

DSB810A Digital DC Servo Driver Manual V1.0

Active Vibration Isolation of an Unbalanced Machine Tool Spindle

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Non-linear Control of a Piezoelectric Two Stage Servovalve

RT-5005/5006/5007/5008

MCE441/541 Midterm Project Position Control of Rotary Servomechanism

Step vs. Servo Selecting the Best

G320X MANUAL DC BRUSH SERVO MOTOR DRIVE

Sensors and Sensing Motors, Encoders and Motor Control

Mechatronics Engineering and Automation Faculty of Engineering, Ain Shams University MCT-151, Spring 2015 Lab-4: Electric Actuators

PYKC 7 March 2019 EA2.3 Electronics 2 Lecture 18-1

Control Theory. This course will examine the control functions found in HVAC systems and explain the different applications where they are applied.

Direct Operated Proportional DC Valve Series D1FP

The Discussion of this exercise covers the following points: Angular position control block diagram and fundamentals. Power amplifier 0.

DEVELOPMENT OF OPTO-PNEUMATIC ON-OFF VALVE AND ITS APPLICATION TO POSITIONING

ECET 211 Electric Machines & Controls Lecture 4-2 Motor Control Devices: Lecture 4 Motor Control Devices

JUNE 2014 Solved Question Paper

Speed Feedback and Current Control in PWM DC Motor Drives

Robotic Swing Drive as Exploit of Stiffness Control Implementation

Proportional Directional Control Valves Series D*FH and D*FM General Description Operation Features Series D*FH Series D*FM

Sensors and Sensing Motors, Encoders and Motor Control

Different Controller Terms

DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY EEE 402 : CONTROL SYSTEMS SESSIONAL

Modeling and Control of Mold Oscillation

An Introduction to Proportional- Integral-Derivative (PID) Controllers

Control Design for Servomechanisms July 2005, Glasgow Detailed Training Course Agenda

REDUCING THE STEADY-STATE ERROR BY TWO-STEP CURRENT INPUT FOR A FULL-DIGITAL PNEUMATIC MOTOR SPEED CONTROL

A DESIGN TO DIGITALIZE HYDRAULIC CYLINDER CONTROL OF A MACHINE TOOL

Continental Hydraulics Installation Manual CEM-PA-A

A Searching Analyses for Best PID Tuning Method for CNC Servo Drive

CHAPTER 5 CONCEPTS OF ALTERNATING CURRENT

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Performance Optimization Using Slotless Motors and PWM Drives

Hydraulic Valve Interface Products

ValveExpert. Check / Adjust / Repair Servo- and Proportional Valves

SYNCHRONOUS MACHINES

Proportional directional valves

signals and their parameterisation

ELECTRONIC FUNDAMENTALS

Introduction to the ME2110 Kit. Controller Box Electro Mechanical Actuators & Sensors Pneumatics

5. Transducers Definition and General Concept of Transducer Classification of Transducers

Feedback Devices. By John Mazurkiewicz. Baldor Electric

Motion Control Glossary

E l e c t r i c A c t u a t o r s

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

INSTRUCTION MANUAL SERIES TRANSMITTER

Valve amplifier for proportional valves with electrical position feedback

Catalog Hydraulics meets Electronics.

CHAPTER 1 SYNCHROS LEARNING OBJECTIVES. 5. Explain the differences between torque and control synchros.

[ á{tå TÄàt. Chapter Four. Time Domain Analysis of control system

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

Transcription:

Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org Electro-hydraulic Servo Valve Systems [ You may download the article at: https://fluidsys.org/downloads/ ] Hydraulic systems driven by servo valves provide highly accurate control over enormous forces. A servo valve system consists of a transducer, a servo amplifier, a servo valve, and an actuator with a connected load. It is a closed-loop system used for the precise control of the output (load) parameter, such as position, velocity, or force, in response to a command signal. The output is converted into an equivalent electrical signal by the transducer. This feedback signal is compared to a command signal (representing the required output) to generate an error signal. The error signal is amplified by the amplifier. The amplified signal controls the valve. The servo valve regulates the fluid flow in proportion to the current from the amplifier. The actuator then drives the load to move in a precise manner in such a way as to reduce the error signal. According to the type of feedback signals, closed-loop servo systems can be classified into three basic types: (1) Position servo system (2) Velocity servo system and (3) Pressure/Force servo system. Servo Amplifier It mainly contains a summing junction, an amplifier with a PID circuit, a ramp generator, and a dither oscillator. The servo amplifier generates an error signal, due to the difference between the measured output signal and the command input signal, at the summing junction. The servo valve responds to the amplifier signal by controlling fluid delivery into/out of the associated actuator. A PID circuit in the amplifier controls the way the system approaches the desired output. The ramp generator is used to control the rate of change of the amplifier s output and consequently controls the rate at which the valve opens or closes. The dither oscillator can be used in the amplifier to reduce the effects of friction due to the sliding of the spool against the valve body, and inertia. 1

Servo Valves A servo valve is a precisely machined spool-type directional control valve with a current-driven mechanism using a torque motor to control the spool position. A torque motor can be considered as an electromechanical transducer that produces a small deflection proportional to the input current. It can impart the necessary motion to the spool either directly or indirectly. The spool can be infinitely positioned to control the direction of flow and the amount of pressure, in response to electrical/ electronic control signals. Servo valves are available in one-stage, two-stage, or three-stage designs. A single-stage servo valve consists of a torque motor directly attached to the sliding spool of the valve. The torque motor must supply enough torque to the valve to shift its spool directly against an opposing pressure. The single-stage valve has limited power capability. A two-stage servo valve consists of a torque motor, a pilot spool, and the main spool. First, the torque motor shifts the pilot spool, which in turn, directs fluid flow to move the main spool. In a three-stage servo valve, the pilot stage is divided into two, namely 1 st stage pilot, and 2 nd stage pilot. The first-stage pilot spool shifts the second-stage pilot spool, which, in turn, shifts the main spool. The three-stage servo valves are used for application with high-flow, high-pressure requirements. Torque Motor A torque motor consists of upper and lower pole pieces, armature, two coils, flapper and flexure tube. The two pole pieces one polarized North and the other polarized South - provide paths for the magnetic flux. The armature is mounted on a pivot and is suspended in the air gaps of the magnetic field. Its ends are positioned in the middle of the air gap between the upper and lower pole pieces. When electric current flows through these coils, the armature gets polarized. One end of the armature is attracted to one pole piece, and the other end is repelled by the same pole piece at the other end. In this way, the torque motor converts the input signal to a proportionate semi-rotary movement of the armature, either clockwise or anticlockwise, depending on the magnetic polarity. The displacement of the armature is limited to a few thousandths of an inch. The small deflection of the armature can be used to control the pilot stage of the servo valve through the connecting mechanism. Two main forms of construction are used for connecting the armature to the pilot stage of the valve. They are: (1) the flapper nozzle arrangement and (2) the jet pipe arrangement. The flapper-nozzle arrangement is explained below. Flapper Nozzle Arrangement It consists of a flapper lever and two nozzles. The armature/flapper assembly is supported on a flexure tube that allows it to rotate until the torque produced equals the restraining torque in the flexure tube. A flapper lever, attached to the armature of the torque motor, is aligned between the two nozzles. This arrangement forms two variable orifices between the nozzle tips and the flapper. 2

The movement of the flapper lever controls the flow through the nozzles. If the torque motor rotates the flapper counter-clockwise, then the orifice on the right-hand side becomes smaller than that on the left-hand side. The resulting pressure on the right-hand side of the spool becomes greater than that at its left-hand side. This pressure difference moves the spool to the left by an amount proportional to the current level in the armature coil. The position of the spool controls the amount, rate, and duration of flow to the actuator. As the spool moves in response to the pressure differential across the spool, a feedback wire exerts an opposite torque on the armature/flapper assembly trying to re-center the flapper. The spool continues to move until the torque produced by the feedback wire equals that produced by the control signal. This arrangement of the armature/flapper assembly imparts a controlled motion to the spool and positions the spool in proportion to the input current. Lap Conditions in Servo Valves Three critical lap conditions exist in servo valves according to the width of the spool land in comparison with the width of the opening of the associated port in the sleeve: (1) Line-to-line (zero-overlap), (2) Open-centre (underlapped), (3) Closed-centre (over-lapped). (a) Line-to-line (b) Open-centre (Under-lapped) (c) Closed-centre (Over-lapped) Zero-overlap: In the zero-overlap (line-to-line) configuration, the spool of the valve is machined and aligned precisely to obtain a line-to-line fit of the flow metering edges with the opening in the valve body. Therefore, the zero-lapped valve is capable of delivering a flow to the connected actuator ports immediately in response to a differentially small amount of spool shift, either way. Under-lapped: In an under-lapped (open-centre) servo valve, the land width of the spool is smaller than the port width of the valve. Therefore, the under-lapped valve delivers a flow even when the valve remains in its centre position. Over-lapped: In an over-lapped (closed-centre) servo valve, the spool land width is greater than the port width. The over-lapped valve has a deadband. It means that the spool has to move a certain distance before a flow can be delivered. Null Drift and Null Adjustment There is a tendency for a servo valve especially the zero-lapped one to drift from its center position due to the presence of contamination, or variations in temperature or supply pressure or load pressure. A shift in the null position of the valve is indicated when the associated actuator experiences significant flow at zero input signal and 3

causes errors in the system. It is often necessary to readjust the null position by turning the null screw to make the flow output to zero or make the pressures at the blocked working ports of the valve equal when no input signal is applied. Servo Valve Characteristics A system response has two essential components: (1) Transient (dynamic) response, and (2) Steady-state response. The transient response represents the momentary variations of the system parameters, such as pressure and flow rate, in response to a sudden change in the input signal applied to the system. If the system is inherently stable, the transient response disappears soon. The steady-state condition is a state in which system parameters, such as flow rate and pressure, do not vary significantly with time after the initial fluctuations of the parameters have disappeared. Steady State Characteristics Two types of gains are usually set for servo valves. Flow gain and pressure gain are the two essential steady-state parameters. Other parameters are the pressure drop across the valve, hysteresis, threshold (resolution), linearity, and symmetry. Flow characteristics Pressure Curve Transient (Dynamic) Characteristics The transient response can be described by its step response and frequency response. Step Response It is measured by recording the spool displacement (x) versus time, for a step input current (I). Usually, there are two possibilities when a step input is applied to the servo valve under no-load conditions. The system may appear as what is known as a first-order system or a second-order system. 4

First-Order System The behavior of a first order system to a step input is given below. The Time constant of a first-order servo valve is the time required for its output to reach about 63% of the steady-state value. The settling time is the time required for its output to reach and stay within a defined tolerance band. Second-Order System In the second order system, the output increases rapidly, overshoot the steady-state condition, and eventually settle at an appropriate value, in response to a step input function. The most important parameters are defined below: Delay Time: The time required for the output to reach 50% of its steady-state value. Rise Time: The time required for the output to rise from 10%-90% of its steady-state value. Maximum Overshoot Time: The time at which the maximum overshoot of the output occurs. Settling Time: The time for the output to reach and stay within its stated tolerance band. 5

Sinusoidal Input (Frequency) Response A step response is not considered as an exceptional measure of the performance of the valve, because of the inherent inaccuracies in measuring it. A much more accepted method of measuring the transient response is by subjecting the valve to a sinusoidal input signal over a range of frequencies, and then comparing the behaviour of the output flow of the valve, for each frequency. When a sinusoidal input signal is applied to the valve, its output follows the input signal with some error. At low frequencies, the output follows the input signal. At high frequencies, the error tends to increase. The frequency response is usually measured with constant input current amplitude and a zero pressure drop across the load. It is measured with the two parameters: (1) Amplitude ratio and (2) Phase angle (Shift). Amplitude Ratio (AR) It is the ratio of the flow amplitude at any frequency to that at a specified reference frequency (typically 5 Hz). Amplitude ratio is usually expressed in decibels (db). Amplitude ratio = 20 log 10 (AR) db Phase Angle (lag) It is the difference in degrees between the phase of a sinusoidal input current and the corresponding phase of the output flow, measured at a specified frequency. The figure shows the typical dynamic response of a second-order system with Amplitude-Ratio curve and the phase-lag curve over some frequency range. The dynamic response of the valve can easily be determined by referring to the frequencies at which 3 db amplitude ratio (AR) and 90 phase angle do occur. 6

Electro-hydraulic Servo Positioning System The basic objective of position servo system is to move the hydraulic actuator in the system to the desired position and stop. This objective requires a closed-loop control system that has a command signal and a feedback signal. Once the actuator is in the desired position, the two signals produce a zero error signal (position error) in the system. Then, the servo valve must close so as to hold the actuator in place. Effect of Contamination on Servo Valves Servo valve clearances are tiny, and, therefore, they are extremely prone to fluid contamination. Contamination can gum up the valve and results in its reduced response. Application of Servo Valves Electro-hydraulic servo valves are used in high-precision systems employing high-power hydraulics controlled by low power (< 200 mw) electronics. Closed-loop electro-hydraulic servo systems are increasingly becoming the norm in machine automation, where the system requirements are demanding greater precision. Servo valves find applications in a process plant, power generation, and mining. The plastic manufacturing sector uses the power and precision of servo valves for improving the quality of blow-moulded and injection-moulded parts. The steel industry is a unique branch where the power of hydraulics is essential along with the precision of electronic control. Servo valves are also gaining wide acceptance in a variety of application areas, such as material handling, oil and gas, and mobile equipment. Authored by JOJI Parambath, Founder/Director, Fluidsys Training Centre, Bangalore email: info@fluidsys.in website: https://fluidsys.org Reference: JOJI PARAMBATH, Industrial Hydraulic Systems Theory and Practice, Universal Publishers, Boca Raton, USA, 2016. Please visit: http://www.universalpublishers.com/book.php?method=isbn&book=1627340580 Note: A comprehensive account of the topic is given in the textbook on Industrial Hydraulic Systems-Theory and Practice by Joji Parambath. [ For more useful article and downloads, please visit: https://fluidsys.org/downloads/ ] 7