OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Similar documents
Technical Instructions Document No EA GQD June 23, OpenAir

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

DCS-62 Series Spring Return Electronic Actuator Product Bulletin

Spring Return DuraDrive Proportional Actuator

Non-Spring Return DuraDrive Modulating Actuator

Non-Spring Return EconoDrive Proportional Actuator

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

QPM Series Indoor Air Quality Duct Sensors

Power consumption In operation At rest For wire sizing

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

OpenAir Linear actuators GDB/GLB...2 Technical basics. CE1Z4664en Building Technologies

Rotary actuators for ball valves

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

FEATURES OPTIONAL FEATURES

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Technical data sheet. Technical data. Safety notes

Power consumption In operation At rest For wire sizing

ELECTRONIC ROTARY GEAR MOTOR SERIES SED (AR2...SE )

658 Current to Position Converters

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

Powers Controls No. 3 Pneumatic Damper Actuator

Overview of types. Technical data

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical Instructions Document No P25 May 5, Reversing Actuators. Description

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rotary actuators for ball valves

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Electromotoric actuators

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

PART # mA Positioner

Zelio Control Measurement Relays

Sealed Interface Control: EC20300

LA-5000 SERIES LINEAR VALVE ACTUATORS

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

AMC mA Positioner

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Rotary actuators for ball valves

RL 147 Positioning Relay Calibration

Rotary actuators for ball valves

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

MODEL: MRP6. Final Control Elements

MG350V Globe Valve SmartX Actuator

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Technical data. Parameterisable damper actuator in the

Air damper actuators

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

Fisher 4200 Series Electronic Position Transmitters

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in.

RWD44U Controller. Installation and Commissioning Guide Document No October 5, Function. Application

Rotary gear motor series AG8...

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Fuzzy Temperature Controllers E5AF

LM Series Direct Coupled Actuator

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Fireye. NEXUS FX04 and FX04-1 Servo Motor Installation DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

Dual Technology Wall Mount Occupancy Sensor

Room Temperature Controllers. for heating and cooling systems

Electronic Air / Fuel Ratio Control System

AD-8100 & AD-8200 Servo Amplifiers

Power supply CP-D 24/1.3

02/11/2015

Current Loop Interface Module M 2025D

Product Data Sheet 8452/2HHP. The engineer's choice

Differential pressure sensors

INSTRUCTION MANUAL (ATEX / IECEx)

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

PKG-171-MBC25-PS-CBL System Diagram and Specifications

BFS / BFSM SERIES Installation & Maintenance Manual

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

HLC-1000 High-limit Humidity Control

02/11/2015

PowerFlex 400 AC Drive Guide Specification

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

02/11/2015

Single Phase Soft Starters

Power supply CP-D 24/4.2 Primary switch mode power supply

Transcription:

Document No. 155-187P25 EA GDE/GLB-1 OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Description The OpenAir direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. Features Compact, lightweight design Application Self-adapting capability for maximum flexibility in damper positioning Manual override Offset and slope adjustment models available Independently adjustable dual auxiliary switches available cul and UL listed; certified These actuators are used in constant or variable air volume installations for control of HVAC dampers requiring up to 44 lb-in (5 Nm) or 88 lb-in (10 Nm) of torque. Product Numbers Torque Standard Slope/ Offset Adjustable Table 1. Dual Auxiliary Switches and Slope/Offset Adjustable Dual Auxiliary Switches Only Pre-Cabled No Cables GDE161.1P GDE166.1P Plenum GDE163.1P GDE164.1P GDE161.1P/B (24 pk) GDE161.1Q 6 ft length 44 lb-in (5 Nm) GDE161.1N Post Header GDE161.1N/B (24 pk) AMP GDE161.1T Terminal Strip GDE161.1T/B (24 pk) 88 lb-in GLB161.1P GLB163.1P GLB164.1P GLB166.1P Plenum (10 Nm) GLB161.1Q 6 ft length

Document Number: 155-187P25 24 Vac Modulating Control Specifications Power Supply Control signal Operating voltage (G G0) 24 Vac +20%, -15% Frequency 50/60 Hz Power consumption 3.3 VA Input signal (Y-G0) Voltage-input 0 to 10 Vdc Input resistance >100K ohms Feedback signal Position output signal (U G0) (GDE161.1T and GDE161.1N do not have feedback signals) Voltage-output 0 to 10 Vdc Maximum output current DC 1 ma Equipment rating Rating Class 2 according to UL, CSA Class III per EN60730 Auxiliary features Function Mounting Control signal adjustment Offset (start point) Slope (span) Dual auxiliary switch contact rating Voltage DC rating Switch Range Switch A Between 0 to 5 Vdc Between 2 and 30 Vdc 4A resistive, 2A inductive 24 Vac/24 Vdc 12 to 30 Vdc DC 2A 0 to with 5 intervals Recommended range usage 0 to 45 Factory setting 5 Switch B 0 to with 5 intervals Recommended range usage 45 to Factory setting 85 Switching hysteresis: 2 Torque GDE 44 lb-in (5 Nm) GLB 88 lb-in (10 Nm) Runtime for opening or closing GDE sec. at 60 Hz (108 sec. at 50 Hz) GLB 125 sec. at 60 Hz (150 sec. at 50 Hz) Nominal angle of rotation Maximum angular rotation 95 Shaft size: Minimum shaft length 3/4-inch (20 mm) EA1010R1 3/8 to 5/8 inch 8-16 mm 1/4 to 1/2 inch 6-12.7 mm 9/16 inch 15 mm Figure 1. Acceptable Shaft Sizes. Page 2

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Specifications, continued Housing Enclosure NEMA Type 2 IP54 according to EN60529 GDE161.1T and GDE161.1N NEMA 1 Material Durable plastic Gear lubrication Silicone-free Ambient conditions Ambient temperature Operation -25 F to 130 F (-32 C to 55 C) Storage and transport -40 F to 158 F (-40 C to 70 C) Ambient humidity (non-condensing) 95% rh Agency certification UL listed to UL873 cul certified to Canadian Standard C22.2 No. 24-93 These devices were approved for installation in plenum areas by Underwriters Laboratories, Inc., per UL 1995. conformity In accordance with the directive set forth by the European Union for Electromagnetic Compatibility (EMC) 2004/108/EC Emissions standards EN61000-6-3 Immunity standards EN61000-6-2 Miscellaneous Pre-cabled connection 18 AWG Standard cable length 3 ft (0.9 m) Life cycle Designed for over 60,000 full strokes and a minimum of 1.5 million repositions at rated torque and temperature Dimensions inches (mm) 6.2 L 2.8 W 2.4 D (157 L 71 W 61 D) Weight: 1.06 lb (0.48 kg) Country of Origin USA Page 3

Document Number: 155-187P25 Accessories 24 Vac Modulating Control The auxiliary switches cannot be added in the field. Order the product number that includes this option. See Table 1. ASK76.1U: Provides connection between the actuator and conduit. EA0647R1 Figure 2. Conduit Adapter. GDE161.1T Terminal Strip and GDE161.1N Post Header AMP are not compatible with the ASK76.1U. EA0695R1 ASK71.5: Allows a direct-coupled actuator to provide an auxiliary linear drive. Figure 3. Rotary to Linear. ASK71.6: Allows economical mounting of an OpenAir actuator to a variety of surfaces. Ea0696R1 Figure 4. Rotary to Linear with Bracket. Should be used in applications where the actuator can be rigidsurface mounted and a linear stroke output is needed. Figure 5. Tandem Mount Bracket. EA0807R1 Figure 6. Shaft Insert. ASK73.1: Bracket provides extended anti-rotation pin allowing two OpenAir actuators to directly drive a single damper shaft. For use with two- and three-position actuators. ASK78.3U: Shaft inserts for use with 3/8-inch (8 to 10 mm) diameter shafts. (10/pk). Included in box with GDE/GLB Series. Factory-installed 1/2- inch guide must be removed prior to installation. 985-101P25: Shaft guide, 1/2-inch (25/pk). Factory installed with GDE/GLB Series. EA1060R1 Figure 7. 1/2-inch Shaft Guide. Page 4

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Accessories, Continued EA1248R1 985-133: 0 to 10 Vdc input cable 3 ft, 12 pk Figure 8. EA1248R1 985-134: Daisy chain cable 12 ft, 12 pk 985-135: Daisy chain cable 25 ft, 12 pk Figure 9. Actuator Components 1 15 16 Legend 1. Base plate 14 2. Positioning scale for angle of rotation 2 A B 10 20 3. Slope adjustment 45 80 70 60 50 Aux Switch Adjustment 12,13 4. Offset (start point) adjustment 11 5. DIP switches 3 4 Ys Uo U V U 2 10 16 30 24 Uo 0 1 2 3 5 4 10 9 6. Cover for DIP switches 7. Connection cables 8. Connection cables self adapt 0 9. Manual override 10. Coupling bushing self adapt 5 6 7 8 17 11. Factory installed 1/2-inch guide EA0641R3 0 Figure 10. Parts of the Actuator. 12. Auxiliary switch A 13. Auxiliary switch B 14. Position indicator 15. Adjustment lever with locking screw (4 mm hex) 16. Set screw for mechanical range stop (4 mm hex) 17. Mounting bracket Page 5

Document Number: 155-187P25 Actuator Components, Continued Terminal Strip 24 Vac Modulating Control GDE161.1T: The GDE161.1T uses a Terminal Strip for connection purposes rather than cable connections. GDE161.1T EA1093R1 COM 0 to 10 Vdc Input Supply 24 Vac Figure 11. Post Header AMP GDE161.1N GDE161.1N: The GDE161.1N model uses a Post Header for connection purposes rather than cable connections. The Post Header AMP has two identical sets of contacts. EA1239R1 G0 Y G G0 Y G Input (Output) Output (Input) Cables are purchased separately. See Accessories. Figure 12. Page 6

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Operation A continuous 0 to 10 Vdc signal from a controller to wire 8 (Y) operates the damper actuator. The angle of rotation is proportional to the control signal. A 0 to 10 Vdc position feedback output signal is available between wire 9 (U) and wire 2 (G0) to monitor the position of the damper motor. In the event of a power failure, the actuator holds its position. In the event that only the control signal is lost, the actuator returns to the "0" position. Life expectancy Control signal adjustment An improperly tuned loop will cause excessive repositioning that will shorten the life of the actuator. GDE/GLB163.1P and GDE/GLB164.1P: For sequencing and the electronic limitation of the angle of rotation. Use the Uo potentiometer to set the offset (start point) between 0 to 5 Vdc. Use the ΔU potentiometer to set the slope (span) between 2 to 30 Vdc. The Y input is limited to a maximum of 10 Vdc. If the sum of the offset and slope setting is greater than 10V, the angle of rotation is reduced providing the feature of electronic limitation of the angle of rotation. Ys [%] 100 1) 4) Ys Uo U V EA0632R1 0 3) 2) 2 5 10 30 35 Y [V] ΔUw U O ΔU (max. 30 V) SLOPE, U 2 10 16 30 24 Figure 13. Ys Actuator position (100% = angle of rotation *) Y Control input signal Uo Offset (start point) ΔU Slope ΔUw Active voltage range (Ys changes) * When the mechanical limitation of the angle of rotation and self-adapt function are ON, 100% does not equal. OFFSET, Uo 0 1 2 EA0633R2 5 4 3 Setting for 10V slope 0 Vdc offset Figure 14. Examples in Figure 13 Uo Offset Vdc Table 2. ΔU Slope Vdc Active Voltage Range Vdc Ys Actuator Position 1. Minimum slope 0 2 0 to 2 0 to 100% 2. Limitation of rotation 5 30 5 to 10 0 to 16.7% 3. Limitation of rotation 0 30 0 to 10 0 to 33.3% 4. Setting shown in Figure 14 0 10 0 to 10 0 to 100% Page 7

Document Number: 155-187P25 24 Vac Modulating Control Operation, continued Control signal adjustment example: Determine the setting needed to electronically limit the angle of rotation between 0 to 50% (0 to 45 ) using a 2 to 10 Vdc input. Calculating the value of ΔU: 100[%] 100% Δ U = (10[ Vdc] Uo[ Vdc]) = (10Vdc 2Vdc) = 16Vdc working angle 50% of rotation Ys[%] Settings: Uo = 2 Vdc; ΔU = 16 Vdc Y S [%] 100 Electronic limitation angle of rotation Ys = 50% (45 ) Slope ΔU = 16V Active voltage range ΔUw = 2 to 10 Vdc EA0634R1 50 0 2 10 18 ΔUw (8 V) Uo ΔU (16 V) Y [V] Figure 15. Example. Auxiliary Switches GDE/GLB164.1P and GDE/GLB166.1P Figure 16 shows the adjustable switching values for auxiliary switches A and B. Actuator Scale: Clockwise Adjustment range for Switches A and B Setting interval: 5 Switching hysteresis: 2 Actuator Scale: Counterclockwise EA0640R1-2,5 0 10 20 30 70 80 92,5 A B 0 10 20 30 70 80 92,5 80 70 60 20 10 0-2,5 EA0636R2 A B 10 20 80 70 60 50 AUX SWITCH ADJUSTMENT Figure 16. Adjustable Switching Values for the Dual Auxiliary Switches. The auxiliary switch setting shafts rotate with the actuator. The scale is valid only when the actuator is in the "0" position on clockwise motion. Use the long arm of the (AUX SWITCH ADJUSTMENT) to point to the position of switch A. Use the narrower tab on the red ring to point to the position of switch B. Page 8

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Dual in-line Package (DIP) Switches GDE16x.1P GLB16x.1P Raise the protective cover from left to right to locate the DIP switches. See Figure 10 for the location of the cover. EA0637R1 self adapt 0 Figure 17. Self-adapt Switch. The factory setting is 0 (OFF). When mechanical angle of rotation is limited, the self-adapt switch may be turned ON so that the limited range will become the new 0 to 100% for the actuator logic. In this case, 0 to 100% is not equal to CAUTION: When turning the self-adaptive feature on or after the software reset with the feature on, the actuator will enter a five-minute calibration cycle as the actuator adjusts to the rotation limits of the system. A software reset happens after power on or may be caused by electrostatic discharge (ESD) at levels of 2kV and above. The position output signal U is not influenced by the selfadapt function. The 0 to 10V feedback signal U is always proportional to 0 to (or to 0 ). self adapt The factory setting is clockwise. The direction of rotation switch should match the damper rotation movement. EA0638R1 0 Figure 18. Direction of Rotation Switch. self adapt The factory setting is direct acting. As the clockwise angle of rotation increases, the output voltage increases. EA0639R1 0 Figure 19. Output Signal Switch. If the direction of rotation is counterclockwise, the output signal switch should be set at reverse acting to match the direction of the rotation switch. Page 9

Document Number: 155-187P25 24 Vac Modulating Control Sizing Mounting and Installation The type of actuator required depends on several factors. 1. Obtain damper torque ratings (ft-lb/ft 2 or Nm/m 2 ) from the damper manufacturer. 2. Determine the area of the damper. 3. Calculate the total torque required to move the damper: Total Torque = Torque Rating SF 1 Damper Area 1 Safety Factor: When determining the torque of an actuator required, a safety factor should be included for unaccountable variables such as slight misalignments, aging of the damper, etc. A suggested safety factor is 0.80 (or 80% of the rated torque). 4. Select the actuator type from Table 3. Total Torque Table 3. Actuator <44 lb-in (5 Nm) GDE16x <88 lb-in (10 Nm) GLB16x <132 lb-in (15 Nm) GEB16x <221 lb-in (25 Nm) GBB16x <310 lb-in (35 Nm) GIB16x >310 lb-in >620 lb-in (35 Nm 70 Nm) Use tandem mounting bracket ASK73.1 with any GIB1x actuator. Place the actuator on the damper shaft so that the front of the actuator is accessible. The label is on the front side. A mounting bracket is included with the actuator. The minimum damper drive shaft length is 3/4-inch (20 mm). Observe the service envelope around the actuator as shown in Figure 31. Detailed mounting instructions are included with each actuator. EA1002R1 1/2-inch Ø Factory-Installed Guide 3/8-inch Ø Use the shaft insert supplied for any 3/8-inch (8 to 10mm) diameter shaft Figure 20. Damper Shaft Sizes. 5/8-inch Ø For all damper shafts with the exception of the 1/2-inch round shaft: Remove 1/2-inch Ø guide before installation. Page 10

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Manual Override To move the damper blades and lock the position with no power present: ADJUSTMENT LEVER 2 1. Slide the red manual override knob toward the back of the actuator. 45 2. Make adjustments to the damper position. MANUAL 3. Slide the red manual override knob toward the front of the actuator. Once power is restored, the actuator returns to automated control. PL0013R2 AUTO Figure 21. Manual Override. 3 1 Mechanical Range Adjustment To mechanically limit the range of the damper blade. 1. Loosen the stop set screw. 2. Move the screw along the track to the desired position, and fasten it in place. 1 4 mm 2 < 45 45 EA0535R2 EA0536R2 Figure 22. Moving the Mechanical Range Stop. Example: To use the entire 0 to 10V input signal to control the mechanically limited range, see Figure 17 for setting self-adaptive features. Stop set screw at 70 Self-adapt switch ON Input signal Y = 5 Vdc The damper will be at 35 (50% of the adjusted range.) On versions with the slope and offset features, this example assumes Offset Uo = 0 Vdc Slope ΔU = 10 Vdc Page 11

Document Number: 155-187P25 24 Vac Modulating Control Wiring All wiring must conform to NEC and local codes and regulations. Use earth ground isolating step-down Class 2 transformers. Do not use autotransformers. The sum of the VA ratings of all actuators and all other components powered by one transformer must not exceed the rating of the transformer. It is recommended that one transformer power no more than 10 actuators. WARNING: All six outputs of the dual auxiliary switch (A and B) must only be connected to: Class 2 voltage (UL/CSA). Separated Extra-Low Voltage (SELV) or Protective Extra Low Voltage (PELV) (according to HD384-4-41) for installations requiring conformance. WARNINGS: Installations requiring Conformance: All wiring for CE certified actuators must be SELV or PELV rated per HD384-4-41. Use safety-isolating transformers (Class III transformer) per EN61558. They must be rated for 100% duty cycle. Over current protection for supply lines is maximum 10A. Wiring Diagrams 24 Vac power supply 0 to 10V modulating control Each wire has the standard symbol printed on it. Standard Symbol Function Table 4. Terminal Designation Color 1 Supply (SP) G Red 2 Neutral (SN) G0 Black 8 0 to 10V input signal Y Gray 9 Output for 0 to 10 Vdc U Pink position indication Factory-installed Options S1 Switch A Common Q11 Black S2 Switch A - NC Q12 Black S3 Switch A - NO Q14 Black S4 Switch B - Common Q21 Black S5 Switch B - NC Q22 Black S6 Switch B - NO Q24 Black Page 12

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Wiring, Continued Terminal Strip Maximum wire size for the GDE161.1T is 14 AWG. GDE161.1T 8 GDE161.1T M EA1093R1 COM 0 to 10 Vdc Input Supply 24 Vac EA1092R1 1 2 Figure 23. GDE161.1T Terminal Strip. Figure 24. GDE161.1T Wiring Diagram. Strain Relief Securing the wires/cabling will prevent breakage and ensure strong signals to and from the GDE161.1T model. 45 The following is recommended: 1. The open bracket to the right of the actuator terminal strip is the strain relief for the customer provided control wires. 2. Secure the wires to the actuator bracket with a cable tie as shown in Figure 25. EA1097R1 Figure 25. Page 13

Document Number: 155-187P25 24 Vac Modulating Control Wiring, Continued Post Header AMP GDE161.1N The GDE161.1N Post Header AMP has two sets of identical contacts as shown in Figure 26. All wiring must conform to NEC and local codes and regulations. Use earth ground isolating step-down Class 2 transformers. Do not use autotransformers. Determine the supply transformer rating by summing the total VA of all actuators used. It is recommended that one transformer power no more than 12 actuators. WARNING: Installations requiring Conformance All wiring for CE rated actuators must only be separated extra low voltage (SELV) or protective extra low voltage (PELV) per HD384-4-41. Use safety-isolating transformers (Class III transformer) per EN 61558. They must be rated for 100% duty cycle. Over current protection for supply lines is maximum 10A. CAUTION: It is necessary that the output current properly sustain and operate all GDE161.1N actuators in a daisy chain configuration. You must select either the top 3 contacts or the bottom 3 contacts. EA1239R1 GDE161.1N G0 Y G G0 Y G Input (Output) Output (Input) Figure 26. GDE161.1N Post Header AMP. 8 M EA1092R1 1 2 Figure 27. GDE161.1N 0 to 10 Vdc Modulating Control Wiring Diagram. Page 14

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Wiring, Continued Post Header AMP The input cable (purchased separately) brings power and a control signal to the first actuator in a daisy chain configuration. See Figure 29 and Figure 30. CAUTION: Insert the plug into the GDE161.1N from the left to prevent damage to the cable wires. (See Figure 28) 1. The open bracket to the right of the actuator (See Figure 26) is used for strain relief of the customer purchased cabling (See Required Tools). 2. Secure the cabling to the actuator bracket with a cable tie. (See Figure 29.) Modulating Control Input Cable 3 ft 985-133 12 pk 45 You must select either the top 3 contacts or the bottom 3 contacts. EA1247R1 Cable Tie EA1244R1 Cable Tie Input cable from controller sold separately Figure 28. Always Insert the Cable From the Left. Figure 29. Input Cable Installed in Bottom Three Contacts. Table 5. Daisy Chain Cables 12 ft 985-134 12 pk 12 ft 985-135 12 pk Page 15

Document Number: 155-187P25 24 Vac Modulating Control Wiring, Continued Daisy Chain Configuration, 45 45 45 You must select either the top 3 contacts or the bottom 3 contacts. EA1238R1 Input cable from controller sold separately Figure 30. WARNING: Do not configure more than 12 actuators in a daisy chain at any time. Troubleshooting WARNING: Do not open the actuator. If the actuator is inoperative, replace the unit. Page 16

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Start-Up/ Commissioning 1. Check that the wires are connected correctly. 2. Check that offset and slope are set correctly, if used. 3. Check that the direction of rotation switch/cable matches the rotation of the damper shaft. 4. Connect wires 1 (red) and 2 (black) to a Digital Multimeter (DMM) with the dial set at AC V to verify that the operating voltage is within range. Check operation: 1. Connect wires 1 (red) and 2 (black) to the actuator. 2. Set the DMM dial to Vdc. 3. Connect wires 2 (black) and 8 (gray) to the DMM. 4. Apply a full-scale input signal (10 Vdc) to wire 8 (gray). 5. Allow the actuator shaft coupling to rotate from 0 to. 6. Disconnect wire 8 (gray) and the shaft coupling returns to the 0 position. Check Feedback: 1. Set the DMM dial to Vdc. 2. Attach wires 2 (black) and 9 (pink) to the DMM. 3. Apply a full-scale input signal to wire 8 (gray). The reading at the DMM should increase. 4. Remove the signal from wire 8 (gray). The reading at the DMM should decrease and the actuator shaft coupling returns to the 0 position. Check the Auxiliary Switch A: 1. Set the DMM dial to ohms (resistance) or continuity check. 2. Connect wires S1 and S3 to the DMM. The DMM should indicate open circuit or no resistance. 3. Apply a full-scale input signal to wire 8 (gray). The DMM should indicate contact closure as the actuator shaft coupling reaches the setting of switch A. 4. Connect wires S1 and S2 to the DMM. The DMM should indicate open circuit or no resistance. 5. Stop the signal to wire 8 (gray). The DMM should indicate contact closure as the actuator shaft coupling reaches the setting of switch A. Check the Auxiliary Switch B: 1. Set the DMM dial to ohms (resistance) or continuity check. 2. Connect wires S4 and S6 to the DMM. The DMM should indicate open circuit or no resistance. 3. Apply a full-scale input signal to wire 8 (gray). The DMM should indicate contact closure as the actuator shaft coupling reaches the setting of switch B. 4. Connect wires S4 and S5 to the DMM. The DMM should indicate open circuit or no resistance. 5. Stop the signal to wire 8 (gray). The DMM should indicate contact closure as the actuator shaft coupling reaches the setting of switch B. Page 17

Document Number: 155-187P25 24 Vac Modulating Control Dimensions 7/16 (11) min. 4 inch 100 mm 1/32 (0.8) 1/2 (12) 25/32 (20) 5-7/16 (137) min. 1/4 inch 6 mm min. 8 inch 200 mm 3-7/16 (87) 6-5/8 (168) 7-1/16 (180) 15/16 (94) 2-3/8 (60) min. 2-3/8 inch 60 mm 5/32 (4) EA0531R2 min. 1 inch 25 mm min. 3/8 inch 10 mm 13/16 (21) EA0530R3 2-3/4 (70) Figure 31. GDE/GLB Actuator and Mounting Bracket Dimensions in Inches (mm). Page 18

Technical Instructions 24 Vac Modulating Control Document Number: 155-187P25 Dimensions, continued.46 (12) min. 4 (100) 1/2 (12) 25/32 (20).04 (1) 6-5/8 (168) 7-1/16 (180) 6.2 (156,3) min..25 (6) min. 8 (200) 3.4 (87) EA0531R2.8 (19,3).96 (24) 1.8 (44,9) 2.4 (61) min. 2.38 (60).16 (4,15).84 (21,4) EA1242R1 2.8 (70,7) Figure 32. GDE161.1T and GDE161.1N Actuators and Mounting Bracket Dimensions in Inches (mm). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. OpenAir is a registered trademark of Siemens Schweiz AG. Other product or company names mentioned herein may be the trademarks of their respective owners. 2011 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 USA + 1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com Document No. 155-187P25 Printed in the USA Page 19