XTL-FA-01 Edge Filter for Xenus: User Guide

Similar documents
R10-FA-01 Ruggedized Edge Filter for Xenus: User Guide

Copley ASCII Interface Programmer s Guide

Combining Today s Best Technologies. For Tomorrow s Break Through Discoveries. Control Modes. Command Interface. Communications

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

Analog Servo Drive. Continuous Current. Features

Analog Servo Drive 25A20DD

Accelus CARD SERVOAMPLIFIER

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

FEATURES DESCRIPTION THE OEM ADVANTAGE

Analog Servo Drive 30A8

Electrical Specifications

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

Xenus XSL User Guide P/N

ASP-X2. Accelus Panel. Control Modes Current (torque, force)

Analog Servo Drive 30A20AC

Analog Servo Drive 20A20

Analog Servo Drive 30A8

External brake resistor AX2090-BW5x

Dynamo Brushless DC Motor and GreenDriveTM Manual

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

AxCent Servo Drive A50A100

Model SPDT Power Switch Module

AxCent Servo Drive A25A100

Analog Servo Drive 100A40

AC/DC Power Supply Series APPLICATION NOTE

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

2017 Advanced Energy Industries, Inc. HITEK POWER MH60 SERIES VERSATILE HIGH-VOLTAGE POWER SUPPLY MODULES

Xenus XTL. RoHS. Control Modes Indexer, Point-to-Point, PVT Camming, Gearing, Position, Velocity, Torque

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

PRODUCT SPECIFICATION

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

DigiFlex Servo Drive DPQNNIE-060A400

American Power Design, Inc.

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Analog Servo Drive BD15A8

Junus. to HV max. PWM minimum pulse width

USER MANUAL LDY CW Diode Driver Power Supplies

G250X MANUAL STEP MOTOR DRIVE

USER MANUAL. CW Diode Driver Power Supplies

Xenus Micro RoHS XSJ Model Vac

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

FC1010 FC10010 FC15030 BFC1010 BFC10010 BFC15030 BFC

Xenus XTL User Guide P/N

6/24/02 DigiMod 500 DigiMod 1000 DigiMod 1500 DigiMod 2000HV DigiMod 1000NPS. User Manual

Xenus R10. RoHS. RUGGEDIZED DIGITAL SERVO DRIVE for BRUSHLESS/BRUSH MOTORS

A53106 SERIES DC-TO-DC CONVERTER

Installation Instructions Space Temperature Transmitter

Analog Servo Drive 10A8

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Xenus R11. RoHS. RUGGEDIZED DIGITAL SERVO DRIVE for BRUSHLESS/BRUSH MOTORS

PP400B060-ND. H-Bridge POW-R-PAK IGBT Assembly 400 Amperes/600 Volts

G251X MANUAL STEP MOTOR DRIVE

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Documentation. PerfectPulse Fast Edge Signal Generator

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

Analog Servo Drive B25A20

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

NI PXIe-5630 Specifications

DigiFlex Servo Drive DPQNNIE-015B200

USER MANUAL NUPOWER TM 12B01A L & S BAND POWER AMPLIFIER

USER MANUAL NUPOWER TM 12A03A MICRO L & S BAND POWER AMPLIFIER

100V GaN E-HEMT Half Bridge Evaluation Kit. Visit for the latest version of this user s guide.

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Xenus Micro XSJ DESCRIPTION

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

BTM Series Pulsed RF Power Amplifier Modules. Application Note

CEC VIBRATION TRANSMITTER

100V GaN E-HEMT Half Bridge Evaluation Kit. Visit for the latest version of this user s guide.

Electrical Specifications

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

AxCent Servo Drive AZBE10A4IC

DC-DC Converter Module

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

Trusted Speed Monitor Input FTA (SIFTA)

Electrical Specifications

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

American Power Design, Inc.

DigiMod 3000PFC DigiMod 3000PFCsu

GS Product Specification. 1 of 19 N. QSFP+ Cable to Board Connector System 1.0 SCOPE 2.0 PRODUCT DESCRIPTION

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

AC/DC Power Supply Series APPLICATION NOTE

American Power Design, Inc.

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Transcription:

XTL-FA-01 Edge Filter for Xenus: User Guide P/N 95-00378-000 Revision 3 June 2008

Edge Filter for Xenus: User Guide This page for notes.

TABLE OF CONTENTS About This Guide... iii Overview and Scope...iii Related Documentation...iii Comments...iii Copyrights...iii Document Validity...iii Product Warnings... iv Revision History... iv 1: XTL-FA-01 Edge Filter... 5 1.1: Overview... 6 1.1.1: Differential and Common Mode Filtering... 6 1.1.2: Description and Functional Diagram... 6 1.1.3: PWM Output Plot... 6 1.2: XTL-FA-01 Edge Filter Specifications... 7 1.3: Thermal Considerations... 7 1.4: XTL-FA-01 Edge Filter Dimensions... 8 1.5: XTL-FA-01 Edge Filter Wiring... 9 1.5.1: Electrical Codes and Warnings... 9 1.5.2: Connector Locations... 10 1.5.3: Cable Notes... 11 1.5.4: Input (J1) From Amplifier... 11 1.5.5: Output (J2) To Motor... 11 1.5.6: Diagram: Edge Filter Wiring with Brushless Motor... 12 1.5.7: Diagram: Edge Filter Wiring with Brush Motor... 12 1.6: XTL-FA-01 Edge Filter Ordering... 13 Copley Controls Corp. i

Table of Contents Edge Filter for Xenus: User Guide This page for notes. ii Copley Controls Corp.

ABOUT THIS GUIDE Overview and Scope This guide describes the installation and connection of the Xenus Model XTL-FA-01 edge filter. Related Documentation Related information is available in these Copley Controls documents: Xenus XTL User Guide CME 2 User Guide Information on Copley Controls Software can be found at: http://www.copleycontrols.com/motion/products/software/index.html Comments Copley Controls Corporation welcomes your comments on this guide. For contact information, see http://www.copleycontrols.com Copyrights No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Copley Controls Corporation. Xenus, XTL, and CME 2 are registered trademarks of Copley Controls Corporation. Document Validity We reserve the right to modify our products. The information in this document is subject to change without notice and does not represent a commitment by Copley Controls Corporation. Copley Controls Corporation assumes no responsibility for any errors that may appear in this document. Copley Controls Corp. iii

About this Guide Edge Filter for Xenus: User Guide Product Warnings Observe all relevant state, regional, and local safety regulations when installing and using this product. For safety and to assure compliance with documented system data, only Copley Controls Corporation should perform repairs.! DANGER: Hazardous voltages. Exercise caution when installing and adjusting. Failure to heed this warning can cause equipment damage, injury, or death. DANGER! DANGER! Risk of electric shock. High-voltage circuits on Xenus J1, J2, and J3 and on Filter J1 and J2 are connected to mains power. Failure to heed this warning can cause equipment damage, injury, or death. Use equipment as described. Operate equipment within the specifications provided in this manual. Failure to heed this warning can cause equipment damage, injury, or death. DANGER Revision History Release Date DECO # Comments 1.0 February Initial publication. 2005 2 December 2007 16397 Minor updates including RoHS compliance indication. 3 June 2008 17137 Updated Web page references. iv Copley Controls Corp.

CHAPTER 1: XTL-FA-01 EDGE FILTER This chapter provides an overview of the Model XTL-FA-01 edge filter. The contents of this chapter include: Title Page 1.1: Overview... 6 1.2: XTL-FA-01 Edge Filter Specifications... 7 1.3: Thermal Considerations... 7 1.4: XTL-FA-01 Edge Filter Dimensions... 8 1.5: XTL-FA-01 Edge Filter Wiring... 9 1.6: XTL-FA-01 Edge Filter Ordering... 13 Copley Controls Corp. 5

Xenus Filter Edge Filter for Xenus: User Guide 1.1: Overview The XTL-FA-01 edge filter can be used to minimize noise on the output of any Xenus amplifier. The XTL-FA-01 edge filter is RoHS compliant. 1.1.1: Differential and Common Mode Filtering Most noise is capacitively coupled from the motor power cable to neighboring cables. To minimize this noise, the XTL-FA-01 edge filter uses both differential edge filtering and common mode filtering. Differential edge filtering reduces the high frequency component of the PWM signal, thus producing a signal with less energy that can be coupled during transmission. Common mode filtering reduces the unnecessary common mode noise generated by PWM signals. 1.1.2: Description and Functional Diagram The differential filter increases the rise time by at least a factor of 3, substantially reducing noise in the system. Copley Controls amplifiers typically have a 150 ns-rise time (high frequency component in the MHz range). Thus, the edge filter can increase rise time to 500 ns, reducing the high frequency noise emissions by the square law. The differential filter is designed with 82 CH inductors and a proprietary passive circuit. The inductance will provide a total of 164CH in series with the load, helping to reduce ripple current. This brings low inductance motors into the required range. The common mode filter is designed with a 220 CH common mode toroid that works with the cable capacitance to earth ground to remove common mode switching noise. Amp Filter Motor J1 J2 U U J1-4 J2-4 V J1-3 82uH 82uH J2-3 V W J1-2 J1-1 Common Mode 82uH Differential Mode W J2-2 J2-1 Case GND 1.1.3: PWM Output Plot +HV 90% 10% 500ns 150ns Raw PWM Filtered 6 Copley Controls Corp.

Edge Filter for Xenus: User Guide Xenus Filter 1.2: XTL-FA-01 Edge Filter Specifications Input Output Peak Current/Peak Current Time Rise/Fall Time Differential Mode Inductance Common Mode Inductance Nominal Resistance Agency Approvals Voltage, maximum Current, maximum Voltage, maximum Current, maximum 1.3: Thermal Considerations 373 Vdc 20 Adc 373 Vdc 20 Adc 40 Adc for 1 second 500 ms (typical) 82 CH per phase, 162 uh phase-phase (nominal) 220 CH (nominal) 27 milliohms per leg, 54 milliohms phase-phase (nominal) UL508C, EN60204, RoHS Cooling Requirements When used with XTL-230-18 or XTL 230-36 amplifiers, the XTL-FA-01 operates below maximum temperature values, and thus requires no cooling fan. When used with XTL-40 amplifiers running continuous currents greater than 12 Adc, the XTL-FA-01 should be cooled with an external fan. The fan should have a flow rate of at least 110 CFM. The filter has been tested using the Comair Rotron MD24B2 24 Vdc powered fan. Fan Mounting Guidelines Most of the filter s heat is transferred to ambient air, rather than through the heat plate. Thus, it is very important to mount the filter and fan in such a way that the fan can blow up through the filter s cover slots. Mount the filter on edge and mount the fan below it so that it blows up through the cover slots. There is no heatsink option for the XTL-FA-01 edge filter. Copley Controls Corp. 7

Xenus Filter Edge Filter for Xenus: User Guide 1.4: XTL-FA-01 Edge Filter Dimensions The following diagram shows the mounting dimensions of the XTL-FA-01 Edge Filter. 8 Copley Controls Corp.

Edge Filter for Xenus: User Guide Xenus Filter 1.5: XTL-FA-01 Edge Filter Wiring This section describes the wiring of the XTL-FA-01 Edge Filter. 1.5.1: Electrical Codes and Warnings Be sure that all wiring complies with the National Electrical Code (NEC) or its national equivalent, and all prevailing local codes.! DANGER: Hazardous voltages. Exercise caution when installing. Failure to heed this warning can cause equipment damage, injury, or death. DANGER! DANGER! WARNING Risk of electric shock. High-voltage circuits on Xenus J1, J2, and J3 and on Filter J1 and J2 are connected to mains power. Failure to heed this warning can cause equipment damage, injury, or death. Do not ground mains-connected circuits. With the exception of the ground pins on Xenus J1, J2, and J3 and on Filter J1 and J2, all of the other circuits on these connectors are mains-connected and must never be grounded. Failure to heed this warning can cause equipment damage. Copley Controls Corp. 9

Xenus Filter Edge Filter for Xenus: User Guide 1.5.2: Connector Locations Edge Filter J1 connects to Xenus J2. Edge Filter J2 connects to the motor. 10 Copley Controls Corp.

Edge Filter for Xenus: User Guide Xenus Filter 1.5.3: Cable Notes 1 Keep the Edge Filter J1 to Xenus J2 cable as short as possible. A typical length is 7 inches. 2 To reduce noise, twisted shielded cable must be used and the signal cables should not be bundled in the same conduit. 1.5.4: Input (J1) From Amplifier Mating Connector Description Euro-style, 5 position, 5.0 mm pluggable female terminal block Manufacturer PN Wago 51118042 or 721-105/026-047/RN01-0000 Wire Size 22-12 AWG Recommended Wire 12 AWG, 600 V (Shielded cable used for CE compliance) Wire Insertion/Extraction Tool Wago 231-131 Connector and tool are included in connector kit XTL-FK. Pin Description Pin Signal Function 1 Ground Chassis ground and cable shield 2 Phase W Phase W input from amplifier 3 Phase V Phase V input from amplifier (use for DC motor connection) 4 Phase U Phase U input from amplifier (use for DC motor connection) 5 --- No connection 1.5.5: Output (J2) To Motor Mating Connector Description Euro-style, 4 position, 5.0 mm pluggable female terminal block. Manufacturer PN Wago 51118008 or 721-104/026-047/RN01-0000 Wire Size 22-12 AWG Recommended Wire 12 AWG, 600 V (Shielded cable used for CE compliance) Wire Insertion/Extraction Tool Wago 231-131 Connector and tool are included in connector kit XTL-FK. Pin Description Pin Signal Function 1 Ground Chassis ground and cable shield 2 Phase W Phase W output to motor 3 Phase V Phase V output to motor (use for DC motor connection) 4 Phase U Phase U output to motor (use for DC motor connection) Copley Controls Corp. 11

Xenus Filter Edge Filter for Xenus: User Guide 1.5.6: Diagram: Edge Filter Wiring with Brushless Motor Amplifier J2-4 J2-3 J2-2 U V W Filter J1-5 J1-4 J2-4 J1-3 J2-3 J1-2 J2-2 A B C Brushless Motor J2-1 J1-1 J2-1 Case Ground 1.5.7: Diagram: Edge Filter Wiring with Brush Motor Amplifier J2-4 J2-3 U V Filter J1-5 J1-4 J2-4 J1-3 J2-3 + - Brush Motor J2-2 J2-1 J1-2 J1-1 J2-2 J2-1 Case Ground 12 Copley Controls Corp.

Edge Filter for Xenus: User Guide Xenus Filter 1.6: XTL-FA-01 Edge Filter Ordering Filter Model XTL-FA-01 Description Xenus Edge Filter Connector Kit Model Qty Ref Description Mfr.Model No. 1 J1 Plug, 5 position, 5.0 mm, female Wago 51118042 or 721-105/026-047/RN01-0000 XTL-FK 1 J2 Plug, 4 position, 5.0 mm, female Wago 51118008 or 721-104/026-047/RN01-0000 2 -- Insertion / Extraction Tool Wago 231-131 Copley Controls Corp. 13

XTL-FA-01 Edge Filter for Xenus: User Guide P/N 95-00378-000 Revision 3 June 2008 2005, 2006, 2007, 2008 Copley Controls Corporation 20 Dan Road Canton, MA 02021 USA All rights reserved