EWP Product Guide. For Use With Products Manufactured by. Corona Westampton Largo Montgomery Humble Thornhill, Ontario THFI2514

Similar documents
For Use With Products Manufactured by

EWP Product Guide. For Use With Products Manufactured by.

EWP Product Guide. For Use With Products Manufactured by THF23140 LSSH179 SKH1720L

Backer Block (both sides) of web with single RFPI Joist. (12) - 10d. Backer Block. each side. 2 min. 2 min.

For Use With Products Manufactured by

LSSH179 THF17925 THO17118

EWP Product Guide. For Use With Products Manufactured by. BCI I-Joists. Canadian Specifiers Guide. USPconnectors.com LIMIT STATES DESIGN SKH2520R-2

EWP Product Guide. For Use With Products Manufactured by. Canadian Specifiers Guide. USPconnectors.com LIMIT STATES DESIGN SKH2520R-2 LSSH35 THFI2514

EWP Product Guide. For Use With Products Manufactured by. TJI 110, 210, 230, 360, & 560 Joists.

CONNECTOR SELECTION GUIDE

CONNECTOR SELECTION GUIDE

CONNECTOR SELECTION GUIDE

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.


T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

Main Floor Revisions: 38' 0" Rm1 H3 50' 0" Bk1 B1 Rm2 B5 (26)-2 H2 B2 H3 (3)-3 B3 (11)-4 Bk1 B1 (5)-5 Rm4 Bk1 Rm3 Bk1 24' 0" 6' 0" 20' 0" START FRAMIN

Featuring TJ Rim Board and TimberStrand LSL

RIDGE-JOIST CONNECTION 12/12 maximum slope

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

APA Performance Rated Rim Boards

Wood I-Joists by Curtis Eck, P.E.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

SDWH TIMBER-HEX Screw

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

THE ENGINEERED WOOD ASSOCIATION

Load Tables, Technical Data and Installation Instructions

ROOF SYSTEM DESIGN GUIDE

Designed for Building Designed for Living

Residential I-Joist & LVL INSTALLATION GUIDE

3.1 General Provisions

MAT105: Floor Framing

VERSA-LAM. An Introduction to VERSA-LAM Products

Wood Connections. Concepts of Well Designed Connections

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

Best Barns USA. the Brookhaven 10' x 16' Assembly Book. revised March 23, 2016

Structural Criteria for Residential Flush-Mounted Solar Arrays

Attach Trusses and Rafters Faster

Shearwall System Installation Guide

Structural Criteria for Residential Rooftop Solar Energy Installations

PV System Structural Criteria

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

SECTION ROUGH CARPENTRY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Dura-Lock Roof System

Structural Criteria for Residential Rooftop Solar Energy Installations

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems

Unirac Installation Manual

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

Vertical Offset Base and Safety Rail System Installation Instructions

SEALANT ACCESSORY CONTROL, NOT COMPROMISE. Low VOC Do-All-Ply Sealant

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

A. Rough carpentry includes but is not limited to the following:

INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

5 5 8 " 60" 53 8 " " 7" 5 1 2" 7" " FIVE MODELS TO MEET YOUR DESIGN REQUIREMENTS.

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

SD Screw #10x2½" 16dx2½" SD Screw #9x2½" SD Screw 10dx1½" 8d Common N54A 0.25" 0.131"

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

INSTALLATION INSTRUCTIONS

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Belmont with pocket doors. Building Size 12'x16' or 12'x20' Revised January 10, 2012

INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

Designed for Building Designed for Living

Chapter 33: Lofts (Or Second Floors)

FRAMING DETAILS FOR FLOOR AND ROOF

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

TJI 110, TJI 210, TJI 230,

ICBO ES ER-5598 n HUD MR 1310 DSA PA-123 n LAC RR25448 n CCMC R. Limit States Design

Chapter 23. Garage Construction

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

Site Installation Guide

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

WARNING: JOISTS ARE UNSTABLE UNTIL BRACED LATERALLY BRACING INCLUDES:

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

Best Barns USA Assembly Book

Best Barns USA Assembly Book

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

TJI 210 TJI TJI 360 TJI 560 JOISTS

Wood Connections. Presented by: Karyn Beebe, P.E.

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

KOLO SHELTER Installation Instructions Parts List

Best Barns USA Assembly Book

Best Barns USA Assembly Book

METALWORKS Concealed. Installation Instructions

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California / 16

Section Downloads. Terminology Outline. Industry Standards/ Publications. American Softwood Lumber Standard ANSI/TPI 1. Section 02: Terminology

Best Barns USA Assembly Book

Best Barns USA Assembly Book

Best Barns USA Assembly Book

Transcription:

EWP Product Guide For Use With Products Manufactured by www.connectors.com THFI2514 LSSH179 THF25925 TFL25118 Corona Westampton Largo Montgomery Humble Thornhill, Ontario #1032

General Notes Follow these instructions to ensure the proper installation of products. See current Product Catalog for General Notes, Warranty, and installation information for hanger models, joist sizes, and header situations not shown. Loads listed address hanger/header/fastener limitations as well as joist/ hanger limitations assuming header material is Douglas Fir-Larch (DF-L), Southern Pine (SP), or LVL. reaction should be checked by a qualified designer to ensure proper hanger selection. Uplift loads have been increased 60% for wind or seismic loads and no further increase shall be permitted. Reduce loads according to code for normal duration loading such as cantilever construction. If hanger height Plated is less Truss than 60% of joist height, joist rotation may occur; therefore supplemental lateral restraints are required, see page 3. The type and quantity of fasteners used to install products is critical to connector performance. To achieve the allowable loads shown in this catalog, install with the fasteners specified for that particular product. All specified fasteners must be properly installed prior to applying load of any kind to the connection. Throughout this guide, dimensions are expressed in inches and loads in pounds, unless specifically noted otherwise. Load values for 10d and 16d designations in the fastener schedules throughout this catalog refer to common wire nails, unless noted otherwise. The allowable loads shown in this catalog are based on Allowable Stress Design methodology (U.S. only). Multiple Plies: Fasten together multiple plies of wood I- s, in accordance with International Beam s installation guidelines, such that the joists act as a single unit. Sloped Filler s: & Backer Use hangers Block Sizes with sloped seats and beveled web stiffeners whenever the slope exceeds the following: 1 2:12 for seat bearing lengths of 2-1 2 or less; 3 8:12 for bearing lengths between 2-1 2 and 3-1 2 ; and 1 4:12 for bearing lengths in excess of 3-1 2. Backer Blocks Pattern the nails used to install backer blocks or web stiffeners in wood s to avoid splitting the block. The nail pattern should be sufficiently spaced to avoid the same grain line, particularly with solid sawn backer blocks. Backer blocks must be installed on wood s acting as the header, or supporting member. Install in accordance with the I- manufacturer s installation guidelines. The nails used to install hangers mounted to a I-J oist header must penetrate through the web and into the backer block on the opposite side. Filler Block Installation: Nail filler blocks per IB design manual Backer Block Installation: Install tight to top flange (tight to bottom flange with face mount hangers). Attach with twelve 10d (3 ) common nails, clinched when possible. Typical THO backer block installation Gap 1/4 Gap 1/8 Backer Block (both sides) of web with single IB. Typical THF backer block installation Gap 1/8-1/4 (10) - 10d box Backer Block each side Flange Width Depth 9-1/2" 2-1/8" x 6" 11-7/8" 2-1/8" x 8" 2-1/2" IB400 1" (note 1) 14" 2-1/8" x 10" 2-1/2" 3-1/2" With top flange hangers, backer block required only for downward loads exceeding 250 lbs or for uplift conditions Filler and Backer Block sizes Series IB600 IB800 Thickness Required Backer Block Minimum 1 Depth 16" 2-1/8" x 12" 9-1/2" 2-1/8" x 6" 11-7/8" 2-1/8" x 8" 14" 2-1/8" x 10" 1" (note 1) 16" 2-1/8" x 12" 18" 2-1/8" x 14" 20" 2-1/8" x 16" 9-1/2" 3-1/8" x 6" 11-7/8" 3-1/8" x 8" 14" 3-1/8" x 10" 1-1/2" (note 1) 16" 3-1/8" x 12" 18" 3-1/8" x 14" 20" 3-1/8" x 16" 11-7/8" 3-1/8" x 8" 14" 3-1/8" x 10" 3-1/2" IB900 16" 1-1/2" (note 1) 3-1/8" x 12" 18" 3-1/8" x 14" 20" 3-1/8" x 16" 1) For face-mount or top-mount hangers use joist depth minus 4". For example, for 9-1/2" I-joist, use 5-1/2" minimum depth. Web stiffener each side IB400 or IB600 1 x 2-1/2 minimum width. IB800 or IB900 1-1/2 x 3-1/2 minimum width. Page 1 + - 2 + - 2 Filler Block Size Bearing/Web Stiffener Attachment 2-1/2 or 3-1/2 Gap: 1/8-1/4 No Gap (4) 8d nails, 10d required for IB I-s with 3-1/2 flange width IB800 or IB900 for up to 16 I-joist depth. For deeper depths, contact International Beams. 2 Customer Service & Technical Assistance 1-800-328-5934 1-952-898-8772

EWP Installation Support Height & Lateral Stability Hangers for joists without web stiffeners must support the I- s top flange and provide lateral resistance with no less than 1 8 contact. Hangers for joists with web stiffeners must support a minimum of 60% of joist depth, or potential joist rotation must be addressed. 1/8 maximum gap Resist lateral movement Web stiffener depth 60% min. of joist depth (Top flange support requirements can be verified in EWP Top Mount Hangers charts under the Web Stiffener Req. column of s Product Catalog.) Nailer Installations Correct Hanger Attachment to Nailer A nailer or sill plate is considered to be any wood member attached to a steel beam, concrete block wall, concrete stem wall, or other type of structure unsuitable for nailing, which is used as a nailing surface for top mount hangers to hold beams or joists. Nailer Sized Correctly Top flange of hanger is fully supported and recommended nails have full penetration into nailer, resulting in a carried member hanging safely at the proper height. The nailer must be sized to fit the support width as shown and be of sufficient thickness to satisfy recommended top flange nailing requirements. A design professional must specify nailer attachment to steel beams. Wrong Nailer Size Causes Component Failure Avoid direct contact between hangers and steel beams, which may cause squeaks 1/4 Max. Correct Attachment 1/4 Max.! Too Narrow Top flange not fully supported can cause nail breakout. Or, by fully supporting top flange, hanger is tilted back, causing lifting of carried member which results in uneven surfaces and squeaky floors.! Too Wide! Too Thin Loading can cause cross grain breaking of nailer. The recommended nailer overhang is 1 4 maximum per side. Top flange nailing cannot fully penetrate nailer, causing reduced allowable loads. Never use hangers which require multiple face nails since the allowable loads are dependent on all nail holes being used. Top Flange Hangers The thickness of the hanger metal and nail heads on top mount hangers must be evaluated for the effect on subsequent sheathing. Ensure the top mount hanger is installed so the flanges of the hanger are not over-spread which tends to elevate the supported I-, causing uneven floor surfaces and squeaking. Similarly, ensure the hanger is installed plumb such that the face flanges of the hanger are mounted firmly against the wide-face surface of the header. Flush framing! Hanger over-spread! Hanger not plumb www.uspconnectors.com email: uspcustomerservice@mii.com 3

Single International Beam I-s U.S./Allowable Load (Lbs.) Height Stock No. 1 Top Mount Hangers 4 Header Stock No. 1 Header IB400 or IB600 Width = 2-1/2" Face Mount Hangers Fastener Schedule 5 DF/SP S-P-F Fastener Schedule 5 DF/SP S-P-F 9-1/2 TFL2595 (6) 10d (2) 10d x 1-1/2 1600 140 1230 120 THFI2595 (8) 10d -- -- 960 135 960 115 11-7/8 TFL25118 (6) 10d (2) 10d x 1-1/2 1600 140 1230 120 THFI25118 (10) 10d -- -- 1200 135 1200 115 14 TFL2514 (6) 10d (2) 10d x 1-1/2 1600 140 1230 120 THFI2514 Min (12) 10d -- -- 1440 135 1440 115 THFI2514 Max (14) 10d -- -- 1680 135 1680 115 16 TFL2516 (6) 10d (2) 10d x 1-1/2 1600 140 1230 120 THF25160 (22) 10d (2) 10d x 1-1/2 2550 360 2200 310 18 TFI318 (6) 16d (2) 10d x 1-1/2 2560 360 1660 310 THF25160 (22) 10d (2) 10d x 1-1/2 2550 360 2200 310 20 TFI320 (6) 16d (2) 10d x 1-1/2 2560 360 1660 310 THF25160 (22) 10d (2) 10d x 1-1/2 2550 360 2200 310 IB800 Width = 3-1/2" 9-1/2 THO35950 (10) 10d (2) 10d x 1-1/2 2050 265 1720 225 THF35925 (12) 10d (2) 10d x 1-1/2 1370 245 1175 205 11-7/8 THO35118 (10) 10d (2) 10d x 1-1/2 2050 265 1720 225 THF35112 (16) 10d (2) 10d x 1-1/2 1825 245 1570 205 14 THO35140 (12) 10d (2) 10d x 1-1/2 2715 265 2280 225 THF35140 (20) 10d (2) 10d x 1-1/2 2320 245 2000 205 16 THO35160 (12) 10d (2) 10d x 1-1/2 2715 265 2280 225 THF35157 (22) 10d (2) 10d x 1-1/2 2550 245 2200 205 18 TFI418 (6) 16d (2) 10d x 1-1/2 2560 360 1660 310 THF35165 (24) 10d (8) 10d x 1-1/2 2785 1295 2400 1085 20 TFI420 (6) 16d (2) 10d x 1-1/2 2560 360 1660 310 THF35165 (24) 10d (8) 10d x 1-1/2 2785 1295 2400 1085 IB900 Width = 3-1/2" 11-7/8 THO35118 (10) 10d (2) 10d x 1-1/2 2050 265 1720 225 THF35112 (16) 10d (2) 10d x 1-1/2 1825 245 1570 205 14 THO35140 (12) 10d (2) 10d x 1-1/2 2715 265 2280 225 THF35140 (20) 10d (2) 10d x 1-1/2 2320 245 2000 205 16 THO35160 (12) 10d (2) 10d x 1-1/2 2715 265 2280 225 THF35157 (22) 10d (2) 10d x 1-1/2 2550 245 2200 205 18 TFI418 (6) 16d (2) 10d x 1-1/2 2560 360 1660 310 THF35165 (24) 10d (8) 10d x 1-1/2 2785 1295 2400 1085 20 TFI420 (6) 16d (2) 10d x 1-1/2 2560 360 1660 310 THF35165 (24) 10d (8) 10d x 1-1/2 2785 1295 2400 1085 1) Web stiffeners may be required for hangers by joist manufacturer. 2) Loads listed are based on hanger attachment to a DF, SP, or S-P-F species solid sawn or LVL header. Some loads may be increased for duration of load adjustments. Refer to Product Catalog for details. 3) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 4) Top Mount Hangers require minimum 3" header width for THO series hangers; 3-1/2" minimum header thickness for all other stock numbers. 5) 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, and 16d nails are 0.162" dia. x 3-1/2" long. 16d sinkers are 0.148" dia. x 3-1/4" long and may be used where 10d commons are specified. H Additional diamond nail holes for maximum nailing Standard round nail holes for minimum nailing TFL TFI THO THFI W 2 THF single Patented dimple allows 45 nailing 4 Customer Service & Technical Assistance 1-800-328-5934 1-952-898-8772

Single International Beam I-s U.S./Allowable Load (Lbs.) Height IB400 or IB600 Stock No. 1,5 Adjustable Height Hangers Skewed 45 Hangers Fastener Schedule 4 DF/SP S-P-F Fastener Schedule 4 DF/SP Header Stock No. 1,5 Plate Rafter Width = 2-1/2" 9-1/2 -- -- -- -- -- -- -- -- -- -- SKH2520L/R (14) 10d (10) 10d x 1-1/2 1625 1565 1400 1345 11-7/8 MSH322 (6) 10d (4) 10d x 1-1/2 2165 1820 SKH2520L/R (14) 10d (10) 10d x 1-1/2 1625 1565 1400 1345 14 MSH322 (6) 10d (4) 10d x 1-1/2 2165 1820 SKH2524L/R (16) 10d (10) 10d x 1-1/2 1855 1565 1600 1345 16 MSH322 (6) 10d (4) 10d x 1-1/2 2165 1820 SKH2524L/R (16) 10d (10) 10d x 1-1/2 1855 1565 1600 1345 18 MSH322 (6) 10d (4) 10d x 1-1/2 2165 1820 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 20 MSH322 (6) 10d (4) 10d x 1-1/2 2165 1820 -- -- -- -- -- -- -- -- -- -- -- -- -- -- IB800 Width = 3-1/2" 9-1/2 MSH422 (6) 10d (6) 10d 2025 1700 SKH410L/R 6 (16) 16d 2255 1565 1935 1345 11-7/8 MSH422 (6) 10d (6) 10d 2025 1700 SKH410L/R 6 (16) 16d 2255 1565 1935 1345 14 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 16 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 18 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 20 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 IB900 Width = 3-1/2" 11-7/8 MSH422 (6) 10d (6) 10d 2025 1700 SKH410L/R 6 (16) 16d 2255 1565 1935 1345 14 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 16 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 18 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 20 MSH422 (6) 10d (6) 10d 2025 1700 SKH414L/R 6 (22) 16d 3100 1565 2660 1345 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by joist manufacturer. 2) Loads listed are based on hanger attachment to a DF, SP, or S-P-F species solid sawn or LVL header. Some loads may be increased for duration of load adjustments. Refer to Product Catalog for details. 3) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 4) 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, and 16d nails are 0.162" dia. x 3-1/2" long. 5) For additional sizes, stock numbers, and modifications not shown, refer to 's Product Catalog. 6) Miter cut required on end of joist to achieve design loads. S-P-F MSH SKH_L left shown www.uspconnectors.com email: uspcustomerservice@mii.com 5

Double International Beam I-s U.S./Allowable Load (Lbs.) Top Mount Hangers 4 Face Mount Hangers Fastener Schedule 5 DF/SP S-P-F Fastener Schedule 5 DF/SP S-P-F Height Stock No. 1,6 Header Stock No. 1,6 Header Double IB400 or IB600 Width = 5" 9-1/2 THO25950-2 (6) 10d 3535 1175 2710 985 THF25925-2 (12) 10d (6) 10d 1390 1115 1200 960 11-7/8 THO25118-2 (6) 10d 3535 1175 3005 985 THF25112-2 (16) 10d (6) 10d 1855 1115 1600 960 14 THO25140-2 (12) 16d (6) 10d 3535 1175 3265 985 THF25140-2 (20) 10d (6) 10d 2540 1220 2200 1055 16 THO25160-2 (12) 16d (6) 10d 3535 1175 3265 985 THF25160-2 (24) 10d (6) 10d 3050 1220 2640 1055 18 THO25180-2 (14) 16d (6) 10d 3535 1175 3520 985 THF25160-2 (24) 10d (6) 10d 3050 1220 2640 1055 20 THO25200-2 (14) 16d (6) 10d 3535 1175 3520 985 THF25160-2 (24) 10d (6) 10d 3050 1220 2640 1055 Double IB800 Width = 7" 9-1/2 BPH7195 (6) 10d 3485 1220 3280 1055 HD7100 (12) 16d (6) 10d 1690 1140 1450 990 11-7/8 BPH71118 (6) 10d 3455 1220 3280 1055 HD7120 (16) 16d (6) 10d 2255 1140 1935 990 14 BPH7114 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 16 BPH7116 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 18 BPH7118 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 20 BPH7120 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 Double IB900 Width = 7" 11-7/8 BPH71118 (6) 10d 3455 1220 3280 1055 HD7120 (16) 16d (6) 10d 2255 1140 1935 990 14 BPH7114 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 16 BPH7116 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 18 BPH7118 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 20 BPH7120 (6) 10d 3455 1220 3280 1055 HD7140 (20) 16d (8) 10d 2820 1525 2420 1320 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by joist manufacturer. 2) Loads listed are based on hanger attachment to a DF, SP, or S-P-F species solid sawn or LVL header. Some loads may be increased for duration of load adjustments. Refer to Product Catalog for details. 3) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 4) Top Mount Hangers require minimum 3" header width for THO series hangers; 3-1/2" minimum header thickness for all other stock numbers. 5) 10d nails are 0.148" dia. x 3" long, and 16d nails are 0.162" dia. x 3-1/2" long. 16d sinkers are 0.148" dia. x 3-1/4" long and may be used where 10d commons are specified. 6) For additional sizes, stock numbers, and modifications not shown, refer to 's Product Catalog. THO Double BPH THF Double HD 6 Customer Service & Technical Assistance 1-800-328-5934 1-952-898-8772

Double International Beam I-s U.S./Allowable Load (Lbs.) Adjustable Height Hangers Skewed 45 Hangers Fastener Schedule 4 DF/SP S-P-F Fastener Schedule 4 DF/SP S-P-F Height Stock No. 1 Double IB400 or IB600 Header Stock No. 1 Plate Rafter Width = 5" 9-1/2 MSH2622-2 (6) 10d (4) 10d 2210 1690 SKH2520L/R-2 7 (14) 10d (10) 10d 1665 1905 1440 1645 11-7/8 MSH2622-2 (6) 10d (4) 10d 2210 1690 SKH2520L/R-2 7 (14) 10d (10) 10d 1665 1905 1440 1645 14 MSH2622-2 (6) 10d (4) 10d 2210 1690 SKH2524L/R-2 7 (16) 10d (10) 10d 1905 1905 1650 1645 16 MSH2622-2 (6) 10d (4) 10d 2210 1690 SKH2524L/R-2 7 (16) 10d (10) 10d 1905 1905 1650 1645 18 MSH2622-2 (6) 10d (4) 10d 2210 1690 SKH2524L/R-2 7 (16) 10d (10) 10d 1905 1905 1650 1645 20 MSH2622-2 (6) 10d (4) 10d 2210 1690 SKH2524L/R-2 7 (16) 10d (10) 10d 1905 1905 1650 1645 Double IB900 Width = 7" 9-1/2 MSH422-2 (6) 16d 3690 2610 HD7100-SK45L/R 5,6 (12) 16d (6) 10d 1690 855 1450 745 11-7/8 MSH422-2 (6) 16d 3690 2610 HD7120-SK45L/R 5,6 (16) 16d (6) 10d 2255 855 1935 745 14 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 16 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 18 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 20 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 Double IB900 Width = 7" 11-7/8 MSH422-2 (6) 16d 3690 2610 HD7120-SK45L/R 5,6 (16) 16d (6) 10d 2255 855 1935 745 14 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 16 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 18 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 20 MSH422-2 (6) 16d 3690 2610 HD7140-SK45L/R 5,6 (20) 16d (8) 10d 2820 1145 2420 990 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by joist manufacturer. 2) Loads listed are based on hanger attachment to a DF, SP, or S-P-F species solid sawn or LVL header. Some loads may be increased for duration of load adjustments. Refer to Product Catalog for details. 3) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 4) 10d nails are 0.148" dia. x 3" long and 16d nails are 0.162" dia. x 3-1/2" long. 16d sinkers are 0.148" dia. x 3-1/4" long and may be used where 10d commons are specified. 5) Hangers are special order. Consult for pricing and lead times. 6) Miter cut required on end of joist to achieve design loads. MSH SKH_L Double left shown www.uspconnectors.com email: uspcustomerservice@mii.com 7

International Beam LVL Beams & Headers Height 1-3/4" IB LVL Stock No. 6 Top Mount Hangers 3 Face Mount Hangers Fastener Schedule 4 Uplift 2 Down 1 Fastener Schedule 4 Header 160% Stock No. 6 Header Uplift 2 160% 7-1/4 PHXU17725 1035 4420 HD1770 (14) 16d (4) 10d x 1-1/2 760 1975 Down 1 9-1/4 9-1/2 11-1/4 11-7/8 14 BPH17925 THO17950 BPH17112 THO17118 BPH1714 (6) 10d (6) 10d (4) 10d x 1-1/2 (2) 10d x 1-1/2 (4) 10d x 1-1/2 (2) 10d x 1-1/2 (4) 10d x 1-1/2 625 270 625 270 625 3340 HD17925 1345 HD17925 3340 HD17112 1345 HD17112 3340 HD1714 (18) 16d (18) 16d (22) 16d (22) 16d (26) 16d (8) 10d x 1-1/2 1065 1065 1065 1065 1065 2540 2540 2900 2900 3140 PHXU17925 PHXU1795 PHXU17112 PHXU17118 PHXU1714 1035 1035 1035 1035 1035 4420 HUS179 5 4420 HUS179 5 4420 HUS179 5 4420 HUS179 5 4420 HUS179 5 (30) 16d (30) 16d (30) 16d (30) 16d (30) 16d 3205 3205 3205 3205 3205 5310 5310 5310 5310 5310 2 Ply 1-3/4" IB LVL or 3-1/2" IB LVL 7-1/4 PHXU35725 (6) 10d 1290 6650 THD48 (28) 16d (16) 10d 2595 3950 9-1/4 9-1/2 11-1/4 11-7/8 14 16 18 PHXU35925 (6) 10d 1290 6650 THD410 (38) 16d (20) 10d 3810 5360 HLBH35925 (15) NA16D-RS (6) 16d 1420 10620 THDH410 5 (46) 16d (12) 16d 3970 8260 PHXU35112 (6) 10d 1290 6650 THD410 (38) 16d (20) 10d 3810 5360 HLBH35112 (15) NA16D-RS (6) 16d 1420 10620 THDH412 5 (56) 16d (14) 16d 5225 9845 PHXU35118 (6) 10d 1290 6650 THD410 (38) 16d (20) 10d 3810 5360 HLBH35118 (15) NA16D-RS (6) 16d 1420 10620 THDH412 5 (56) 16d (14) 16d 5225 9845 PHXU3595 PHXU3514 PHXU3516 PHXU3518 (6) 10d (6) 10d (6) 10d (6) 10d 1290 1290 1290 1290 6650 THD410 6650 THD410 6650 THD412 6650 THD412 (38) 16d (38) 16d (48) 16d (48) 16d (20) 10d (20) 10d (20) 10d (20) 10d 3810 3810 3810 3810 5360 5360 6770 6770 HLBH3595 HLBH3514 HLBH3516 HLBH3518 (15) NA16D-RS (15) NA16D-RS (15) NA16D-RS (15) NA16D-RS (6) 16d (6) 16d (6) 16d (6) 16d 1420 1420 1420 1420 10620 THDH410 5 10620 THDH414 5 10620 THDH414 5 10620 THDH414 5 (46) 16d (66) 16d (66) 16d (66) 16d (12) 16d (16) 16d (16) 16d (16) 16d 3970 6810 6810 6810 8260 9845 9845 9845 1) Loads listed are based on hanger attachment to a DF or SP species LVL header. Some loads may be increased for duration of load adjustments. Refer to 's Product Catalog for details. 2) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 3) Top Mount Hangers require a minimum 3" header thickness for THO series hangers; 3-1/2" minimum header thickness for all other stock numbers. 4) 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, and 16d nails are 0.162" dia. x 3-1/2" long. 16d sinkers are 0.148" dia. x 3-1/4" long and may be used where 10d commons are specified. 5) nails need to be toe nailed at a 30 to 45 angle to achieve listed loads for THDH and HUS models. 6) For additional sizes, stock numbers, and modifications not shown, refer to 's Product Catalog. THO HD HUS 8 Customer Service & Technical Assistance 1-800-328-5934 1-952-898-8772

International Beam LVL Beams & Headers Top Mount Hangers 3 Face Mount Hangers Height Stock No. 6 3 Ply 1-3/4" IB LVL Fastener Schedule 4 Down 1 Fastener Schedule 4 Uplift 2 Uplift 2 Down 1 Header 160% Stock No. 6 Header 160% 7-1/4 BPH55725 (6) 10d 815 3450 HD68 (14) 16d (6) 10d 1140 1975 PHXU55925 (6) 10d 1290 6650 THD610 (38) 16d (20) 10d 3410 5660 9-1/4 HLBH55925 (15) NA16D-RS (6) 16d 1605 10620 THDH610 5 (46) 16d (16) 16d 4565 8725 PHXU5595 (6) 10d 1290 6650 THD610 (38) 16d (20) 10d 3410 5660 9-1/2 HLBH5595 (15) NA16D-RS (6) 16d 1605 10620 THDH610 5 (46) 16d (16) 16d 4565 8725 PHXU55112 (6) 10d 1290 6650 THD610 (38) 16d (20) 10d 3410 5660 11-1/4 HLBH55112 (15) NA16D-RS (6) 16d 1605 10620 THDH612 5 (56) 16d (20) 16d 5180 9935 PHXU55118 (6) 10d 1290 6650 THD610 (38) 16d (20) 10d 3410 5660 11-7/8 HLBH55118 (15) NA16D-RS (6) 16d 1605 10620 THDH612 5 (56) 16d (20) 16d 5180 9935 PHXU5514 (6) 10d 1290 6650 THD610 (38) 16d (20) 10d 3410 5660 14 HLBH5514 (15) NA16D-RS (6) 16d 1605 10620 THDH614 5 (66) 16d (22) 16d 5795 11645 PHXU5516 (6) 10d 1290 6650 THD612 (48) 16d (20) 10d 4065 7150 16 HLBH5516 (15) NA16D-RS (6) 16d 1605 10620 THDH614 5 (66) 16d (22) 16d 5795 11645 PHXU5518 (6) 10d 1290 6650 THD612 (48) 16d (20) 10d 4065 7150 18 HLBH5518 (15) NA16D-RS (6) 16d 1605 10620 THDH614 5 (66) 16d (22) 16d 5795 11645 4 Ply 1-3/4" IB LVL PHXU71925 (6) 10d 1290 6650 THD7210 (38) 16d (20) 10d 3410 5660 9-1/4 HLBH71925 (15) NA16D-RS (6) 16d 1605 10620 THDH7210 5 (46) 16d (12) 16d 3970 8260 PHXU7195 (6) 10d 1290 6650 THD7210 (38) 16d (20) 10d 3410 5660 9-1/2 HLBH7195 (15) NA16D-RS (6) 16d 1605 10620 THDH7210 5 (46) 16d (12) 16d 3970 8260 PHXU71112 (6) 10d 1290 6650 THD7210 (38) 16d (20) 10d 3410 5660 11-1/4 HLBH71112 (15) NA16D-RS (6) 16d 1605 10620 THDH7212 5 (56) 16d (14) 16d 5225 9845 PHXU71118 (6) 10d 1290 6650 THD7210 (38) 16d (20) 10d 3410 5660 11-7/8 HLBH71118 (15) NA16D-RS (6) 16d 1605 10620 THDH7212 5 (56) 16d (14) 16d 5225 9845 PHXU7114 (6) 10d 1290 6650 THD7210 (38) 16d (20) 10d 3410 5660 14 HLBH7114 (15) NA16D-RS (6) 16d 1605 10620 THDH7214 5 (66) 16d (16) 16d 6810 9845 PHXU7116 (6) 10d 1290 6650 HD7120 (16) 16d (6) 10d 1140 2255 16 HLBH7116 (15) NA16D-RS (6) 16d 1605 10620 THDH7214 5 (66) 16d (16) 16d 6810 9845 PHXU7118 (6) 10d 1290 6650 HD7140 (20) 16d (8) 10d 1525 2820 18 HLBH7118 (15) NA16D-RS (6) 16d 1605 10620 THDH7214 5 (66) 16d (16) 16d 6810 9845 1) Loads listed are based on hanger attachment to a DF or SP species LVL header. Some loads may be increased for duration of load adjustments. Refer to 's Product Catalog for details. 2) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 3) Top Mount Hangers require a minimum 3" header thickness for THO series hangers; 3-1/2" minimum header thickness for all other stock numbers. 4) 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, and 16d nails are 0.162" dia. x 3-1/2" long. 16d sinkers are 0.148" dia. x 3-1/4" long and may be used where 10d commons are specified. 5) nails need to be toe nailed at a 30 to 45 angle to achieve listed loads for THDH and HUS models. 6) For additional sizes, stock numbers, and modifications not shown, refer to 's Product Catalog. HLBH PHXU THDH THD www.uspconnectors.com email: uspcustomerservice@mii.com 9

General Installation Slope/Skew Hangers LSSH series Fastener Schedule 4 DF/SP S-P-F Height Stock No. 1 Header IB400 or IB600 Width = 2-1/2" 9-1/2 LSSH25 (14) 16d (12) 10d x 1-1/2 1825 1195 1530 1005 11-7/8 LSSH25 (14) 16d (12) 10d x 1-1/2 1825 1195 1530 1005 14 LSSH25 (14) 16d (12) 10d x 1-1/2 1825 1195 1530 1005 16 LSSH25 6 (14) 16d (12) 10d x 1-1/2 1825 1195 1530 1005 18 LSSH25 6 (14) 16d (12) 10d x 1-1/2 1825 1195 1530 1005 20 LSSH25 6 (14) 16d (12) 10d x 1-1/2 1825 1195 1530 1005 IB800 Width = 3-1/2" 9-1/2 LSSH35 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 11-7/8 LSSH35 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 14 LSSH35 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 16 LSSH35 6 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 18 LSSH35 6 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 20 LSSH35 6 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 IB900 Width = 3-1/2" 11-7/8 LSSH35 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 14 LSSH35 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 16 LSSH35 6 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 18 LSSH35 6 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 20 LSSH35 6 (14) 16d (12) 10d x 1-1/2 1920 1585 1615 1330 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for non-shaded hangers by I-joist manufacturers. 2) Loads listed are based on hanger attachment to a DF, SP, or S-P-F species solid sawn or LVL header. Some loads may be increased for duration of load adjustments. Refer to Product Catalog for details. 3) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 4) 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long and 16d nails are 0.162" dia. x 3-1/2" long. 5) LSTA24 strap required along top chord for lateral restraint. Installation: Use all specified fasteners. Steps: 1. Position LSSH connector against plumb-cut end of joist. Fasten joist side flanges on both sides with 10d (0.148 ) x 1-1/2 nails. Bend seat up to fit against joist bottom and drive (1) 10d (0.148 ) x 1-1/2 nail through bottom seat into rafter bottom. Drive (2) 10d (0.148 ) x 1-1/2 nails at downward angle through dimpled nailing guides. 2. Lean connector and rafter end against ridge beam at desired position. Install 10d (0.148 dia. x 3 long) or 16d (0.162 dia. x 3-1/2 long) nails through nail holes into ridge beam at right 90 angle. If skewing the rafter, only drive nails into ridge beam on inside flange. 3. Bend flange to desired angle. 4. Hammer outside flange until edge touches header. Fasten outside flange to ridge by driving 10d (0.148 dia. x 3 long) or 16d (0.162 dia. x 3-1/2 long) nails through nail holes. Web stiffeners are required for all wood I- installations. Designer may consider adding a tension restraint for the supported member for roof slopes exceeding 6/12. 2 skew to 45 maximum 1 3 & 4 LSSH Variable Pitch Connectors TMP & TMPH series Fastener Schedule 4 DF/SP S-P-F Stock No. 1 Header IB400 or IB600 Width = 2-1/2" TMP25 (6) 10d (4) 10d x 1-1/2 1970 220 1970 220 TMPH25 (10) 10d (8) 10d x 1-1/2 1950 200 1950 200 IB800 or IB900 Width = 3-1/2" TMP4 (6) 10d (4) 10d x 1-1/2 1970 220 1970 220 TMPH4 (10) 10d (8) 10d x 1-1/2 1950 200 1950 200 Installation: Use all specified fasteners. Position connector on top plate. Fasten connector to outside of top plate with specified nails. Insert rafter into rafter pocket. Adjust rafter and pocket to correct pitch. Fasten rafter to connector with specified nails. Installing the TMP requires driving specified nails through the opposing slots in the pocket. TMPH installation involves sliding the fulcrum until it supports the pocket at the desired pitch and nailing down through the fulcrum base into the top plate to lock the fulcrum into position. 1) Shaded hangers require web stiffeners at joist ends. Web stiffeners may be required for hangers by joist manufacturer. 2) Loads listed are based hanger attachment to a DF, SP, or S-P-F species solid sawn or LVL header. Loads are governed by test results; no further increase shall be permitted. 3) Uplift loads have been increased 60% for wind and seismic loading; no further increase shall be permitted. 4) 10d x 1-1/2 nails are 0.148" dia. x 1-1/2" long and 10d nails are 0.148" dia. x 3" long. fulcrum Pitch Range: TMP 1 12 6 12 TMPH 6 12 14 12 TMP Typical TMP installation TMPH Typical TMPH installation 10 Customer Service & Technical Assistance 1-800-328-5934 1-952-898-8772

General Installation WS Series Wood Screw Applications - Joining 2, 3, or 4 Ply LVL Members or Parallam PSL Members Installation: Screws are self-drilling. Install using a low speed clutch drill with 3/8 hex head driver. The washer head should be flat to the surface and the serrations will oppose turning and release the clutch. Do not over-tighten the screws. For 2 ply members, wood screws shall be installed with the screwheads in the loaded ply. For 3 or 4 ply members, wood screws shall be installed in both outer plies. Designer shall specify all wood screw locations. Increase edge and end distances if wood splitting occurs. Stagger all screws installed into the opposite face. A minimum of 2 rows of screws shall be used for all members with H=5-1/2 and larger. Recommended Row Guidelines H 1 1 /2 min 2 1 /2 min 2 1 /2 min 1 1 /2 min name 3/8 1 min. Recommended (Typ) Other Stagger patterns as approved by Engineer are acceptable Spacing 4 min. 24 max. Screw length L SH T WS Spacing 4 min. 24 max. Serrations 1/4 Beveled reamer Cut threads Self drilling point 4 min End of member Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 WS35 installed in (2) 1-3/4 Ply WS35 installed in (3) 1-3/4 Ply WS6 installed in (4) 1-3/4 Ply WS35 installed in (1) 1-3/4, (1) 3-1/2 Ply WS35 installed in (2) 1-3/4, (1) 3-1/2 Ply WS6 installed in (2) 3-1/2 Ply Stock No. Dimensions (in) Description Ref. No. (in) L SH T WS35 SDS25312 1/4 x 3-1/2 3-1/2 3/4 2-3/4 WS6 7 SDS25600 1/4 x 6 6 1-3/4 1) Based on Zscrew = 243 pounds in Douglas Fir-Larch with a side member thickness of not less than 1-3/4. 2) Load values depicted assume all uniform load is applied to the most narrow outside ply only. 3) Except for Figure 6 installation, load values neglect any contribution of screws installed to opposite side, even if they extend significantly into the loaded ply. 4) Loads are for normal () duration of load, and may be increased in accordance with the code. 5) Uniform loads in table represent the capacity of the fasteners. The capacity of the LVL or PSL beam may be less and should be checked by a qualified designer or with the manufacturer s literature. 4 Maximum Allowable Uniform Loads that can be applied to either outside member (Lbs. Per Lineal Ft.) 1,3,4,5,6 DF/SP Wood Screw Spacing Multiple Members 12" O.C. 18" O.C. 24" O.C. Installation 2 3 2 3 2 3 Figure 2,8 Rows Rows Rows Rows Rows Rows 1 970 1460 650 970 485 730 2 730 1095 485 730 365 545 4 730 1095 485 730 365 545 5 650 970 430 650 325 485 3 650 970 430 650 325 485 6 1940 2920 1300 1940 970 1460 6) A qualified designer shall ensure the adequacy of a 7 wide beam to resist the applied load on one edge; otherwise, the loads shall be uniformly distributed across the width or applied equally on both sides. 7) Wood screws longer than 3-1/2 are not recommended for use with Parallam PSL or TimberStrand LSL. 8) For Figures 2, 3, 5, and 6: Stagger the screws on opposite face by half minimum spacing requirements. www.uspconnectors.com email: uspcustomerservice@mii.com 11

Specification Tools All available on our Web Site @ www.connectors.com Comprehensive Web Site Contains all literature in a printable.pdf format Drawing Library downloads CAD Library CAD Library contains over 350 illustrations in.dxf and.dwg formats Find drawings quickly by Stock No. or Reference No. High Wind Illustrations are also available Customer Service Burnsville, MN Phone: 1-800-328-5934/1-952-898-8772 Fax: 1-952-898-8605 Manufacturing: Montgomery, MN Phoenix, AZ Largo, FL Thornhill, Ontario www.connectors.com Warehouses: Corona, CA Humble, TX Tracy, CA Westampton, NJ Copyright 2015 MiTek USA, Inc. Revised August, 2015