Solid State Relays 1-Phase with Integrated Heatsink Zero Cross or Instant On Switching Types RGC Solid State Contactor 'E' Connection

Similar documents
Solid State Relay. Zero Switching Types RGC Solid State Contactor 'E' Connection. Product Description RGC 1 A 60 A 30 K K E _.

Solid State Relays Zero Switching Types RGC Solid State Contactor 'E' Connection

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection

Solid State Relays Zero Switching Types Solid State Contactor

Solid State Relays 1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

Solid-state Contactor Specifications

Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..

Solid State Relays 3-Phase with Integrated Heatsink Types RGC2, RGC3

Solid-state Contactor Specifications

Solid State Relays 3-Phase with Integrated Heatsink Types 2 & 3 Pole

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Solid State Relays 1-Phase with Integrated Heatsink Proportional Switching Controllers Types RGC1P..AA.., RGC1P..V..

Industrial, 2-Pole ZS Type RA2A

Solid State Relays 3-Phase with Integrated Heatsink Types RGC2, RGC3

2PSS60A40 Solid State Relays 3-Phase with Integrated Heatsink

Starting Torque Controller Technical Data

2-pole solid state relays

2-pole solid state relays

Solid State Relays 1-Phase, Proportional Switching Controllers Types RGS1P..AA.., RGS1P..V..

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

Solid State Relays 1-Phase with Integrated Heatsink Zero Cross Switching, 1600 Vp Blocking Voltage Types RGH

Type CP-S, CP-C & CP-A Switch mode

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

CP-T range Product group picture

08/07/2015

CP-T range Benefits and advantages

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

05/09/2012

08/07/2015

Subject to changes 11/2003 Page 1/7

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Solid State Motor Contactor 3 Phase Motor Reversing Types REC2R

Solid State Relays 3-Phase with Integrated Heatsink Proportional Switching Controllers

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Power supply CP-E 24/20.0

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

02/11/2015

Power supply CP-E 24/2.5

SOLID STATE RELAY RATINGS

Electronic timer CT-TGD.22

RN Thyristor Controllers

Power supply CP-T 48/5.0 Primary switch mode power supply

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Output Voltage* (nom.)(adjustable)

Power supply CP-T 48/20.0 Primary switch mode power supply

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Power supply CP-T 24/20.0 Primary switch mode power supply

02/11/2015

Power supply CP-T 24/10.0 Primary switch mode power supply

SELECTION GUIDE. BULLETIN 156 Solid-State Contactors

Semiconductor contactors, Solid-state relays

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Electronic timer CT-SDD.22

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-E 24/0.75

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

02/11/2015

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-D 24/4.2 Primary switch mode power supply

38 Series - Relay interface modules A

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

CP-E range Benefits and advantages

38 Series - Relay interface modules A

Zelio Control Measurement Relays

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

QUINT-PS/ 3AC/24DC/10

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Power supply CP-D 24/1.3

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

Power supply CP-E 24/2.5

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

QUINT-PS/ 1AC/24DC/20

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

QUINT-PS AC/24DC/40

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Power supply CP-D 12/2.1

Electronic timer CT-SDS.22

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

Thermistor motor protection relays

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Solid State Relay, 1-phase

Transcription:

Solid State Relays 1-Phase with Integrated Heatsink Zero Cross or Instant On Switching Types RGC Solid State Contactor 'E' Connection Product Width ranging from 17.5mm up to 70mm Rated Operational voltage: Up to 600VAC Rated Operational current: Up to 85AAC @ 40 C Up to 18,000A²s for I²t and 1200Vp blocking voltage Control voltages: 3-32 VDC, 20-275 VAC (24-190 VDC) IP20 protection Design according to EN/IEC60947-4-2, EN/IEC60947-4-3, EN/IEC62314, UL508, CSA 22-2 No. 14-10 Integrated voltage transient protection with varistor RoHS compliant Short circuit current rating: 100kA VDE approval Germanischer Lloyd approval1 Product Description This new range of solid state contactors presents a unique opportunity to maximize efficiency in panel space and is an evolution of solid state switches for which Carlo Gavazzi is very well known. The nominal current ratings are at 40 C. The smallest width is 17.5mm and is rated at 20 AAC. Power and control teminals allow for safe looping of cables. Voltage transient protection is standard across the output with a varistor. Specifications are stated at 25 C unless otherwise noted. Ordering Key Solid state relay Number of poles Switching mode Rated operational voltage Control voltage Rated operational current Connection type for control Connection type for power Connection configuration Option RGC 1 A 60 A 30 K K E _ 1. Germanischer Lloyd approval applicable only to models RGC1...15.KE, RGC1...20.KE, RGC1..25..KE and RGC1...30.KE Ordering Key (Refer to page 2 and 3 for available part numbers) 1Phase SSR Rated Voltage, Control Voltage Rated Connection Connection Connection with heatsink Blocking Voltage Currentat 40 C 2 Control Power Configuration Option RGC1A: ZC 4 23: 230V +10% - 15%, 800Vp D: 3 or 4-32VDC 15: 20AAC, 525A²s K: Screw K: Screw E: Contactor P: Overtemperature RGC1B: IO 4 60: 600V +10% -15%, 1200Vp A: 20-275VAC, 20: 23AAC, 525A²s G: Box clamp G: Box Clamp protection 24-190 VDC 25: 25AAC, 1800A²s M: Pluggable (OTP) 3 30: 30AAC, 1800A²s spring-loaded 40: 40AAC, 3200A²s 42: 43AAC, 18000A²s 60: 60AAC, 3200A²s 62: 65AAC, 18000A²s 90: 85AAC, 6600A²s 92: 85AAC, 18000A²s 2. Refer to derating curves 3. Default control connection for RGC...P is Box Clamp. See connections specifications 4. ZC= Zero Cross Switching, IO= Instant ON Switching Specifications are subject to change without notice (26.06.2015) 1

Selection Guide Rated voltage, Control voltage Connection Rated operational current @ 40 o C (I 2 t value) Blocking voltage, Control/ Power Product width Switching mode 20 AAC (525A²s) 23 AAC (525A²s) 25 AAC (1800A²s) 30 AAC (1800A²s) 17.5mm, low depth 17.5mm 17.5mm, low depth 22.5mm 230V, 800Vp 3-32VDC Screw/Screw RGC1A23D15KKE RGC1A23D20KKE RGC1A23D25KKE RGC1A23D30KKE ZC Spring/Screw RGC1A23D15MKE RGC1A23D20MKE RGC1A23D25MKE RGC1A23D30MKE 20-275VAC, 24-190VDC Screw/Screw RGC1A23A15KKE RGC1A23A20KKE RGC1A23A25KKE RGC1A23A30KKE Spring/Screw RGC1A23A15MKE RGC1A23A20MKE RGC1A23A25MKE RGC1A23A30MKE 40 AAC (3200A²s) 43 AAC (18000A²s) 60 AAC (3200A²s) 65 AAC (18000A²s) 35mm 35mm 70mm 70mm 3-32VDC Screw/Box RGC1A23D40KGE RGC1A23D42KGE RGC1A23D60KGE RGC1A23D62KGE Spring/Box RGC1A23D40MGE RGC1A23D42MGE - RGC1A23D62MGE 20-275VAC, 24-190VDC Screw/Box RGC1A23A40KGE RGC1A23A42KGE RGC1A23A60KGE RGC1A23A62KGE Spring/Box RGC1A23A40MGE RGC1A23A42MGE - RGC1A23A62MGE 20 AAC (525A²s) 23 AAC (525A²s) 25 AAC (1800A²s) 30 AAC (1800A²s) 17.5mm, low depth 17.5mm 17.5mm, low depth 22.5mm 600V, 1200Vp 4-32VDC Screw/Screw RGC1A60D15KKE RGC1A60D20KKE RGC1A60D25KKE RGC1A60D30KKE ZC Spring/Screw RGC1A60D15MKE RGC1A60D20MKE RGC1A60D25MKE RGC1A60D30MKE 20-275VAC, 24-190VDC Screw/Screw RGC1A60A15KKE RGC1A60A20KKE RGC1A60A25KKE RGC1A60A30KKE Spring/Screw RGC1A60A15MKE RGC1A60A20MKE RGC1A60A25MKE RGC1A60A30MKE 40 AAC (3200A²s) 43 AAC (18000A²s) 60 AAC (3200A²s) 65 AAC (18000A²s) 35mm 35mm 70mm 70mm 4-32VDC Screw/Box RGC1A60D40KGE RGC1A60D42KGE RGC1A60D60KGE RGC1A60D62KGE Spring/Box RGC1A60D40MGE RGC1A60D42MGE - RGC1A60D62MGE 20-275VAC, 24-190VDC Screw/Box RGC1A60A40KGE RGC1A60A42KGE RGC1A60A60KGE RGC1A60A62KGE Spring/Box RGC1A60A40MGE RGC1A60A42MGE - RGC1A60A62MGE 20 AAC (525A²s) 23 AAC (525A²s) 25 AAC (1800A²s) 30 AAC (1800A²s) 17.5mm, low depth 17.5mm 17.5mm, low depth 22.5mm 600V, 1200Vp 4-32VDC Screw/Screw RGC1B60D15KKE RGC1B60D20KKE RGC1B60D25KKE RGC1B60D30KKE IO 40 AAC (3200A²s) 43 AAC (18000A²s) 60 AAC (3200A²s) 65 AAC (18000A²s) 35mm 35mm 70mm 70mm 4-32VDC Screw/Box RGC1B60D40KGE RGC1B60D42KGE RGC1B60D60KGE RGC1B60D62KGE 2 Specifications are subject to change without notice (26.06.2015)

Selection Guide - RGC..P (Integrated Overtemperature Protection) Rated voltage, Control voltage Connection Rated operational current @ 40 o C (I 2 t value) Blocking voltage, Control/ Power Product width Switching mode 23 AAC (525A²s) 25 AAC (1800A²s) 30 AAC (1800A²s) 85AAC (6600A²s) 22.5mm 22.5mm, low depth 22.5mm 70mm + fan 230V, 800Vp 5-32VDC Screw/Screw RGC1A23D20GKEP - RGC1A23D30GKEP RGC1A23D90GGEP ZC 23 AAC (525A²s) 25 AAC (1800A²s) 30 AAC (1800A²s) 22.5mm 22.5mm, low depth 22.5mm 600V, 1200Vp 5-32VDC Box/Screw RGC1A60D20GKEP RGC1A60D25GKEP RGC1A60D30GKEP ZC 20-275VAC, 24-190VDC Box/Screw RGC1A60A20GKEP RGC1A60A25GKEP RGC1A60A30GKEP 40 AAC (3200A²s) 43 AAC (18000A²s) 60 AAC (3200A²s) 65AAC (18000A²s) 35mm 35mm 70mm 70mm 5-32VDC Box/Box RGC1A60D40GGEP RGC1A60D42GGEP RGC1A60D60GGEP RGC1A60D62GGEP 20-275VAC, 24-190VDC Box/Box RGC1A60A40GGEP RGC1A60A42GGEP RGC1A60A60GGEP RGC1A60A62GGEP 85AAC (6600A²s) 70mm + fan 85AAC (18000A²s) 70mm + fan 5-32VDC Box/Box RGC1A60D90GGEP RGC1A60D92GGEP 20-275VAC, 24-190VDC Box/Box RGC1A60A90GGEP RGC1A60A92GGEP Output Voltage Specifications RGC..23.. RGC..60.. Operational Voltage Range 24-240 VAC, 42-600 VAC, +10%, -15% on max +10% -15% on max Blocking Voltage 800Vp 1200 Vp Internal Varistor 275V 625V General Specifications Latching voltage (across L1-T1) Operational frequency range Power factor Touch Protection Control input status 20V 45 to 65Hz > 0.5 @ Vrated IP20 continuously ON Green LED, when control input is applied Pollution degree 2 (non-conductive pollution with possibilities of condensation) Over-voltage category III (fixed installations) Isolation Input to Output RGC... 4000 Vrms RGC...D..P 2500 Vrms RGC...A..P 4000 Vrms Input and Output RGC... 4000 Vrms to case RGC...D..P 4000 Vrms RGC...A..P 4000 Vrms Input to Fan/ Alarm Output RGC...A..P 2500 Vrms Specifications are subject to change without notice (26.06.2015) 3

Output Specifications (@ 25 C unless otherwise specified) RGC..15.. RGC..20.. RGC..25.. RGC..30.. Rated operational current 6 AC-51 rating @ Ta=25 C 20 AAC 25.5 AAC 30 AAC 30 AAC AC-51 rating @ Ta=40 C 20 AAC 23 AAC 25 AAC 30 AAC AC-53a rating @ Ta=40 C 5 AAC 5 AAC 5 AAC 8 AAC Number of motor starts (x:6, Tx:6s, F:50%) at 40 C 5 30 30 30 30 Min. operational current 150 maac 150 maac 250 maac 250 maac Rep. overload current - (Motor Rating) PF = 0.4-0.5 UL508: T AMB=40 C, t ON=1s, t OFF=9s, 50cycles 51 AAC 60 AAC 51 AAC 84 AAC Maximum transient surge current (I TSM), t=10ms 325 Ap 325 Ap 600 Ap 600Ap Maximum off-state leakage current at rated voltage 3 maac 3 maac 3 maac 3 maac I²t for fusing (t=10ms) Minimum 525 A²s 525 A²s 1800 A²s 1800 A²s Crititcal dv/dt (@ Tj init = 40 C) 1000 V/us 1000 V/us 1000 V/us 1000 V/us RGC..40.. RGC..42.. RGC..60.. RGC..62.. RGC..90.. RGC..92.. Rated operational current 6 AC-51 rating @ Ta=25 C 47 AAC 50 AAC 70 AAC 75 AAC 85 AAC 85 AAC AC-51 rating @ Ta=40 C 40 AAC 43 AAC 60 AAC 65 AAC 85 AAC 85 AAC AC-53a rating @ Ta=40 C 13 AAC 16 AAC 14.8 AAC 20 AAC 18 AAC 20 AAC Number of motor starts (x:6, Tx:6s, F:50%) at 40 C 5 30 30 30 30 30 30 Min. operational current 400 maac 500 maac 400 maac 500 maac 400 maac 500 maac Rep. overload current - (Motor Rating) PF = 0.4-0.5 UL508: T AMB=40 C, t ON=1s, t OFF=9s, 50cycles 126 AAC 126 AAC 126 AAC 168 AAC 168 ACC 168 AAC Maximum transient surge current (I TSM), t=10ms 800 Ap 1900 Ap 800 Ap 1900 Ap 1150 Ap 1900 Ap Maximum off-state leakage current at rated voltage 3 maac 3 maac 3 maac 3 maac 3 maac 3 maac I²t for fusing (t=10ms) Minimum 3200 A²s 18000 A²s 3200 A²s 18000 A²s 6600 A²s 18000 A²s Crititcal dv/dt (@ Tj init = 40 C) 1000 V/us 1000 V/us 1000 V/us 1000 V/us 1000 V/us 1000 V/us 5. Overload current profle definition: x: multiple of AC53a rating, Tx: duration of current surge, F: duty cycle 6. See derating curves Overtemperature Alarm Specifications for RGC...P RGC..D..P RGC..A..P Output type PNP open collector Potential Free Normal state Closed Closed Maximum current rating 50 madc 50 madc Rated voltage (EN61131-2: 2003) 8,7, Ua 24VDC -15%, +20% 24VDC -15%, +20% Rated voltage, Us RGC...D9xGGEP 24VDC ± 10% N/A Fan rating, Uf RGC...A9xGGEP N/A 24VDC ±10%, 50mA nominal Alarm voltage drop Typical 2.8VDC 1.8VDC Maximum 4VDC 3.5VDC Visual Indication Continous Red LED Continous Red LED Reverse polarity protection 24VDC 24VDC 7: DC supply for alarm signal should be supplied from a Class 2 power source 8: Maximum voltage to be applied between 11+ and 12- (Ua) terminals should be 35VDC maximum with reference to A2-4 Specifications are subject to change without notice (26.06.2015)

Input specifications RGC..D.. RGC..A.. Control voltage range 9,10 RGC..23.. 3-32 VDC 20-275 VAC, 24 (-10%) - 190 VDC RGC..60.. 4-32 VDC 20-275 VAC, 24 (-10%) - 190 VDC RGC...P (Uc) 5-32 VDC 20-275 VAC, 24 (-10%) - 190 VDC Pick-up voltage RGC..23.. 3.0 VDC 20 VAC/DC RGC..60.. 3.8 VDC RGC...P 5 VDC 20 VAC/ 24VDC Drop-out voltage 1 VDC 5 VAC/DC Maximum Reverse voltage 32 VDC - Response time pick-up ZC (RGC1A..) 0.5 cycle + 500µs @ 24VDC 2 cycles @ 230VAC/110VDC Response time pick-up IO (RGC1B..) 350µs @ 24 VDC N/A Response time drop-out 0.5 cycle + 500µs @ 24VDC 0.5 cycle + 40ms @ 230VAC/ 110VDC Input current @ 40 C See diagrams below See diagrams below 9. DC control to be supplied by class 2 power source according to UL1310 10. For GL approved models control range for RGC1.23... is 4-32VDC and for RGC1.60... 5-32VDC RG..A.. 40mA RGC1.. A : input current vs input voltage 35mA 30mA 25mA 20mA RGC.. A 15mA 10mA 5mA RGC..A..P (Active Protection) RGC..A..P (Normal Operation) 0mA 0VAC 50VAC 100VAC 150VAC 200VAC 250VAC 300VAC RGC1.. A : input current vs input voltage 40mA 35mA RGC..A..P (Active Protection) 30mA 25mA 20mA 15mA RGC.. A 10mA 5mA RGC..A..P (Normal Operation) 0mA 0VDC 50VDC 100VDC 150VDC 200VDC 250VDC Specifications are subject to change without notice (26.06.2015) 5

Input specifications (cont.) RG..D.. 25.0mA RGC..D..P (Normal Operation) A1 Characteristics: DC input current vs Input voltage x 20.0mA 15.0mA RGC..D..P (Active Protection) 10.0mA 5.0mA 2V 4V 6V 8V 10V 12V 14V 16V 18V 20V 22V 24V 26V 28V 30V 32V 34V x: Input currents for all models except RGC1..D90GGEP and RGC1..D92GGEP 20.0mA IN1 Characteristics: DC input current vs Input voltage y x 15.0mA RGC..D9xGGEP (Normal Operation) 10.0mA 5.0mA RGC..D9xGGEP (Active Protection) 0.0mA 2V 4V 6V 8V 10V 12V 14V 16V 18V 20V 22V 24V 26V 28V 30V 32V 34V y: input currents valid only for RGC1..D90GGEP and RGC1..D92GGEP Motor Ratings: HP (UL508) / kw (EN/IEC60947-4-2) @ 40 C 115 VAC 230 VAC 400 VAC 480 VAC 600 VAC RGC..15 ⅓HP / 0.18kW 1HP / 0.37kW 2HP / 0.75kW 3HP / 1.1kW 3HP / 1.5kW RGC..20 ½HP / 0.18kW 1½HP / 0.37kW 2HP / 0.75kW 3HP / 1.1kW 3HP / 1.5kW RGC..25 ⅓HP / 0.18kW 1HP / 0.37kW 2HP / 0.75kW 3HP / 1.1kW 3HP / 1.5kW RGC..30 ¾HP / 0.37kW 2HP / 1.1kW 3HP / 1.5kW 5HP / 2.2kW 5HP / 3.7kW RGC..40 1HP / 0.56kW 3HP / 1.5kW 5HP / 2.2kW 5HP / 3.7kW 7½HP / 4kW RGC..42 1½HP / 0.56kW 3HP / 1.5kW 5HP / 2.2kW 7½HP / 3.7kW 10HP / 4kW RGC..60 1½HP / 0.56kW 3HP / 1.5kW 5HP / 3kW 7½HP / 4kW 10HP / 4kW RGC..62 2HP / 0.75kW 5HP / 1.5kW 7½HP / 4kW 10HP / 4kW 15HP / 5.5kW RGC..90 2HP / 0.75kW 5HP / 1.5kW 7½HP / 4kW 10HP / 4kW 15HP / 5.5kW RGC..92 2HP / 0.75kW 5HP / 1.5kW 7½HP / 4kW 10HP / 4kW 15HP / 5.5kW 6 Specifications are subject to change without notice (26.06.2015)

Detailed Over temperature Alarm Procedure (for RGC...P) ALARM Signal and Fan (applicable to RGC..D90GGEP) (applicable ALARM to RGC..D92GGEP) Signal and FAN ALARM Signal only ALARM Signal only START START Is Chip temperature > 115 C? N Chip temperature limit reached? N Y Y FAN: ON SSR output: Red LED: Alarm Signal: OFF ON ON Is Chip temperature < 85 C? N Chip temperature limit reached? N Chip temperature < 80 C? N Y FAN: OFF SSR output: Red LED: Alarm Signal: Y OFF ON ON Y SSR output: ON Red LED: OFF Alarm Signal: OFF Is Chip temperature < 80 C? N Y SSR output: ON Red LED: OFF Alarm Signal: OFF FAN: OFF CAUTION Alarm condition resets whenever the voltage signal is removed from terminal A1 (+) In the case of RGC...D9xGGEP, if the voltage signal is not applied across A1(+) and A2 (-) terminals, the overtemperature detection and functionality is lost (including fan operation and alarm signalling) In the case of RGC1A60A9xGGEP it is necessary to supply IN2 and IN3 with 24VDC for fan operation. Alarm procedure for RGC1A60A9xGGEP follows Alarm signal only flow since fan is continously operating. Alarm condition automatically resets ONLY when power semiconductor temperature < 80 C Temperatures indicated are typical figures. Specifications are subject to change without notice (26.06.2015) 7

Output Power Dissipation R G C 1xyyz. C WP 08 C WP 15 C WP x5 C WP 25 C WP 30 C WP 30 C WP 41 C urrent R G C 1..20 R G C 1..30 R G C 1..30 R G H1..20 R G C 1..40 R G C 1..60 R G C 1..90 100W 0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1 0.654 0.624 0.624 0.565 0.630 0.630 0.578 2 1.411 1.347 1.347 1.235 1.342 RGC1..60 1.342 1.246 390W 2.216 2.111 2.111 1.951 2.090 2.090 1.951 4 3.058 2.905 2.905 2.700 2.862 2.862 RGC1..62, 2.682 R 5 3.931 3.723 3.723 3.478 3.655 3.655 RGC1..9x G C 1.. 90 80W 3.434 6 4.832 4.562 4.562 4.281 4.464 4.464 4.203 7 5.759 5.419 5.419 5.105 5.288 5.288 4.988 8 70W 6.710 6.293 6.293 5.951 6.127 6.127 5.787 9 7.684 7.183 7.183 6.816 6.978 6.978 6.600 10 60W 8.680 8.088 8.088 7.699 RGC1..40 R G C 1..40 7.841 7.841 7.424 11 9.697 9.008 9.008 8.600 8.715RGC1..42 8.715 8.261 12 10.736 9.940 9.940 9.518 9.601 9.601 9.108 50W 13 11.795 10.886 10.886 10.453 10.497 10.497 9.966 14 12.874 11.845 11.845 11.404 11.402 11.402 10.834 15 40W 13.973 12.816 12.816 12.371 12.318 12.318 11.711 16 15.091 13.799 RGC1..25, 13.799 13.353 13.243 13.243 12.599 17 16.229 14.793 RGC1..30 14.793 14.351 14.178 14.178 13.495 30W 18 17.385 RGC1..20 15.799 15.799 15.363 15.121 15.121 14.401 19 18.560 16.817 16.817 16.391 16.074 16.074 15.316 20 20W 19.754 RGC1..15 17.845 17.845 17.432 17.035 17.035 16.239 21 20.965 18.885 18.885 18.489 18.005 18.005 17.171 22 22.195 19.935 19.935 19.559 18.983 18.983 18.112 10W 23 23.444 20.996 20.996 20.643 19.969 19.969 19.060 24 24.710 22.067 22.067 21.742 20.964 20.964 20.017 250W 25.993 23.149 23.149 22.854 21.967 21.967 20.982 26 0A 5A27.295 10A 15A 20A 24.24025A 30A24.240 35A 40A 45A 23.980 50A 55A 22.978 60A 65A 70A 22.978 75A 80A 21.955 85A 90A 27 28.614 25.343 25.343 L oad c urrent 25.119 in A A C rms 23.997 23.997 22.935 28 29.951 26.455 26.455 26.272 25.024 25.024 23.924 Power dissiaption in W 8 Specifications are subject to change without notice (26.06.2015)

Current Derating (UL508) temperature 0 25 40 70 80 RGC..15 35 20 20 20 8.2 RGC..20 30 26 23 8.2 RGC..25 30 30 30 25 15.5 RGC..30 30 30 30 19.5 RGC..40 25 57.5 47.4 40.5 12.2 RGC..42 57.5 50 43 28 RGC..60 20 84 70.4 60.5 30 RGC..62 84 75 65.4 38 RGC..90 85 85 85 55 RGC..92, RGC..90 15 85 85 85 55 achieved 60 but will leave 55 Load Current in AACrms 10 RGC..30 RGC..25 RGC..20 RGC..15 5 0 0 10 20 30 40 50 60 70 80 Surrounding Ambient Temperature in C Surrounding Ambient Temperature in C Load Current in AACrms 90 80 70 60 50 40 30 20 10 RGC..92, RGC..90 RGC..62 RGC..60 RGC..42 RGC..40 0 0 10 20 30 40 50 60 70 80 Surrounding Ambient Temperature in Cin C RGC...P models max. operating temperature is + 70 C Specifications are subject to change without notice (26.06.2015) 9

Derating vs. Spacing Curves RGC.. 15.. 25 Load Curre ent in AAC 20 15 10 5 0mm 5mm 0 0 10 20 30 40 50 60 70 80 Surrounding Ambient Temperature in C 10mm & over RGC.. 20.. 35 30 Load Curre ent in AAC 25 20 15 10 5 0 0 10 20 30 40 50 60 70 80 0mm 5mm 10mm 20mm & over Surrounding Ambient Temperature in C RGC.. 25. 30 Load Current in AAC 25 20 15 10 0mm 5mm 10mm 22.5mm & over 5 0 0 10 20 30 40 50 60 70 80 Surrounding Ambient Temperature in C 10 Specifications are subject to change without notice (26.06.2015)

Derating vs. Spacing Curves RGC.. 30.. 35 Load Curren nt in AAC 30 25 20 0mm 5mm 15 10 0 10 20 30 40 50 60 70 80 Surrounding Ambient Temperature in C 10mm & over Stand alone unit RGC.. 40.. 50 45 nt in AAC Load Curre 40 35 30 25 20 15 10 0 10 20 30 40 50 60 70 80 Surrounding Ambient Temperature in C 0mm 10mm & over Stand alone unit RGC.. 42. Specifications are subject to change without notice (26.06.2015) 11

Derating vs. Spacing Curves RGC.. 60.. Load Curre ent in AAC 70 65 60 55 50 45 40 35 30 0 10 20 30 40 50 60 70 80 Surrounding Ambient Temperature in C 0mm 10mm & over Stand alone unit RGC.. 62. RGC.. 90GGEP, RGC..92GGEP 90 Load Curre ent in AAC 85 80 75 70 65 60 55 50 0 10 20 30 40 50 60 70 Surrounding Ambient Temperature in C 0mm 10mm & over Stand alone unit 12 Specifications are subject to change without notice (26.06.2015)

Agency Approvals and Conformances Conformance IEC/EN 62314 IEC/EN 60947-4-2 IEC/EN 60947-4-3 Agency Approvals Short Circuit Current Rating UL508 Listed (E172877) cul Listed (E172877) VDE 0660-109 GL12 100kA, UL508 Electromagnetic Compatibility EMC Immunity IEC/EN 61000-6-2 Electrostatic Discharge (ESD) Immunity IEC/EN 61000-4-2 Air discharge, 8kV Performance Criteria 1 Contact, 4kV Performance Criteria 1 Electrical Fast Transient (Burst) Immunity IEC/EN 61000-4-4 Output: 2kV, 5kHz Performance Criteria 1 Input: 1kV, 5kHz Performance Criteria 1 Electrical Surge Immunity IEC/EN 61000-4-5 (for ) Output, line to line, 1kV Performance Criteria 1 Output, line to earth, 2kV Performance Criteria 1 Input, line to line, 1kV Performance Criteria 2 Input, line to earth, 2kV Performance Criteria 2 Electrical Surge Immunity IEC/EN 61000-4-5 (for P) Output, line to line, 1kV Performance Criteria 1 Output, line to earth, 2kV Performance Criteria 1 DC lines, line to line, 500V Performance Criteria 2 DC lines, line to earth, 500V Performance Criteria 2 Signal lines, line to earth, 1kV Performance Criteria 2 Radiated Radio Frequency Immunity IEC/EN 61000-4-3 10V/m, 80-1000 MHz Performance Criteria 1 10V/m, 1.4-2 GHz Performance Criteria 1 3V/m, 2-2.7 GHz Performance Criteria 1 Conducted Radio Frequency IEC/EN 61000-4-6 Immunity 10V/m, 0.15-80 MHz Performance Criteria 1 Voltage Dips Immunity IEC/EN 61000-4-11 0% for 10ms/20ms Performance Criteria 2 40% for 200ms Performance Criteria 2 70% for 500ms Performance Criteria 2 Voltage Interruptions Immunity IEC/EN 61000-4-11 0% for 5000ms Performance Criteria 2 EMC Emission IEC/EN 61000-6-4 Radio Interference Voltage Emission (Conducted) IEC/EN 55011 0.15-30MHz Class A (industrial) with filters - see filter information IEC/EN 60947-4-2, 60947-4-3 Class A (no filtering needed) Radio Interference Field Emission (Radiated) IEC/EN 55011 30-1000MHz Class A (industrial) Environmental Specifications Operating Temperature 11 Storage Temperature RoHS (2002/95/EC) Impact resistance (EN50155, EN61373) Weight RGC..15 RGC..20 (P) RGC..25 (P) -40 C to 80 C (-40 F to +176 F) -40 C to 100 C (-40 F to +212 F) Compliant 15/11 g/ms approx. 260g approx. 315g (360g) approx. 260g (307g) Vibration resistance (2-100Hz, IEC60068-2-6, EN50155, EN61373) 2g per axis Relative humidity 95% non-condensing @ 40 C UL flammability rating (housing) UL 94 V0 GWIT & GWFI conforms to EN 60335-1 requirements RGC..30 (P) RGC..4x (P) RGC..6x (P) RGC..9x (P) approx. 375g (412g) approx. 515g (581g) approx. 972g (1020g) approx. 1100g 11. Operating temperature range for RGC..P (overtemperature protection) is -30 C to 70 C (-22 F to 158 F) 12. Applicable to models RGC1...15.KE, RGC1...20.KE, RGC1..25..KE and RGC1...30.KE Specifications are subject to change without notice (26.06.2015) 13

Filtering - EN / IEC 55011 Class A compliance (for class B compliance contact us) Part Number Suggested filter for compliance Maximum Heater current RGC1A23..15 68nF/ 275 V / X1 20A RGC1A23..20 68nF/ 275 V / X1 20A RGC1A23..25, RGC1A23..30 220 nf / 275V / X1 30A RGC1A23..40 220 nf / 275V / X1 30A 330 nf / 275V / X1 45A RGC1A23..60 220 nf / 275V / X1 30A 330 nf / 275V / X1 45A RGC1A23..42, RGC1A23..62, 330 nf / 275V / X1 35A RGC1A23..9x 470 nf / 275V / X1 65A RGC1A60..15 100 nf / 760V / X1 20A RGC1A60..20 100 nf / 760V / X1 20A RGC1A60..25, RGC1A60..30 220 nf / 760V / X1 30A RGC1A60..40 220 nf / 760V / X1 25A 330 nf / 760V / X1 45A RGC1A60..60 220 nf / 760V / X1 25A 330 nf / 760V / X1 45A RGC1A60..42, RGC1A60..62, 330 nf / 760V / X1 40A RGC1A23..9x 470 nf / 760V / X1 65A Note: Control input lines must be installed together to maintain products' susceptability to Radio Frequency interference. Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. Use of mains filters may be necessary for cases where the user must meet E.M.C requirements. The capacitor values given inside the filtering specification tables should be taken only as indications, the filter attenuation will depend on the final application. Performance Criteria 1: No degradation of performance or loss of function is allowed when the product is operated as intended. Performance Criteria 2: During the test, degradation of performance or partial loss of function is allowed. However when the test is complete the product should return operating as intended by itself. Performance Criteria 3: Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls. Filter Connection Diagrams 1 Phase 3 Phase L1 L2 L3 SSR SSR SSR LOAD N R d R d R d R d = 1MΩ, 0.5W Filter has to be connected across both LOAD and SSR 14 Specifications are subject to change without notice (26.06.2015)

ALAR M ALAR M S UP P LY G ND Connection Diagram (No OTP) L1 L2/N * AC Controlled A1 ~ 1 L1 In AC controlled types only (RG..A..) a varistor is placed across A1/A2 terminals. DC Controlled Control input * depends on system requirements Load A2-2 T1 In DC controlled types only (RG..D..) a diode is placed in series with the control circuit for protection against reverse biased connection. Connection Diagram (with OTP) RGC1...D20GKEP, RGC1..D25GKEP, RGC1...D30GKEP, RGC1...D4xGGEP, RGC1...D6xGGEP RGC1...D9xGGEP L1 L2/N * 1 L1 Uc: 5-32 VDC Ua: max 35VDC Alarm Output: max. 50mA Uc: 5-32 VDC Us: 24 VDC Alarm Output: max. 50mA 11 + 12 - A1 S witch S olid S tate R G C ONTR OL RGC1...A20GKEP, RGC1..A25GKEP, RGC1...A30GKEP, RGC1...A4xGGEP, RGC1...A6xGGEP RGC1...A9xGGEP FAULT A2 2 T1 Load * depends on system requirements Uc: 24-275 VAC 24-190 VDC Ua: max 35VDC Alarm Output: max. 50mA Uc: 24-275 VAC 24-190 VDC Ua: max. 35 VDC Alarm Output: max. 50mA Uf: 24 VDC Specifications are subject to change without notice (26.06.2015) 15

Terminal Layout and Dimensions RGC...15KKE, RGC...25KKE RGC...15MKE, RGC...25MKE 1 L1 RG Solid State Switch A1 L1 A2 T1 ON A1 A2 2 T1 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal A2 (-): Control ground : Protective earth Housing width tolerance +0.5mm, -0mm as per DIN43880. All other tolerances ± 0.5mm. All dimensions in mm. 16 Specifications are subject to change without notice (26.06.2015)

Terminal Layout and Dimensions (cont). RGC...20KKE RGC...20MKE 1 L1 State Switch A1 L1 RG Solid A2 T1 ON A1 A2 2 T1 RGC...30KKE 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal Housing width tolerance +0.5mm, -0mm as per DIN43880. A2 (-): Control ground All other tolerances ± 0.5mm. : Protective earth All dimensions in mm. Specifications are subject to change without notice (26.06.2015) 17

R G Solid State Switch Terminal Layout and Dimensions (cont.) RGC...30MKE 1 L1 Switch A1 L1 State RG Solid A1 A2 ON T1 A2 2 T1 RGC...40KGE, RGC...42KGE R G Solid State Switch A1 L1 A2 T1 ON A1 A2 RGC...40MGE, RGC...42MGE 1 L1 A1 L1 A2 T1 ON A1 A2 2 T1 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal A2 (-): Control ground : Protective earth Housing width tolerance +0.5mm, -0mm as per DIN43880. All other tolerances ± 0.5mm. All dimensions in mm. 18 Specifications are subject to change without notice (26.06.2015)

Terminal Layout and Dimensions (cont.) RGC...60KGE, RGC...62KGE R G Solid State Switch A1 L1 A2 T1 ON A1 A2 RGC...62MGE 1 L1 R G Solid State Switch A1 L1 A2 T1 ON A1 A2 2 RGC...20GKEP 1 L1 ALARM ALARM 11 + 12 - SUPPLY A1 RG Solid State Switch T1 CONTROL FAULT A2 GND GND 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal 2 T1 (Positive supply in case of RGC1A..D9xGGEP) A2 (-): Control ground IN1: Control signal (only for RGC1A.. D 9xGGEP) IN2: Fan + supply (only for RGC1A60A9xGGEP) IN3: Fan - supply (only for RGC1A60A9xGGEP) 11 + : Alarm output (+) OUT, 12 - : Alarm output (-) : Protective earth Housing width tolerance +0.5mm, -0mm as per DIN43880. All other tolerances ± 0.5mm. All dimensions in mm. Specifications are subject to change without notice (26.06.2015) 19

Terminal Layout and Dimensions (cont.) RGC...25GKEP ALARM ALARM 11 + 12 - SUPPLY A1 RGC...30GKEP 1 L1 ALARM ALARM 11 + 12 - SUPPLY A1 RG Solid State Switch RG Solid State Switch CONTROL FAULT A2 GND GND CONTROL FAULT A2 GND GND 2 T1 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal (Positive supply in case of RGC1A..D9xGGEP) A2 (-): Control ground IN1: Control signal (only for RGC1A.. D 9xGGEP) IN2: Fan + supply (only for RGC1A60A9xGGEP) IN3: Fan - supply (only for RGC1A60A9xGGEP) 11 + : Alarm output (+) OUT, 12 - : Alarm output (-) : Protective earth Housing width tolerance +0.5mm, -0mm as per DIN43880. All other tolerances ± 0.5mm. All dimensions in mm. 20 Specifications are subject to change without notice (26.06.2015)

ALARM FAN + CONTROL FAN - SUPPLY GND A1 Terminal Layout and Dimensions (cont.) RGC...40GGEP, RGC...42GGEP A1 IN2 IN3 A2 RGC...60GGEP, RGC...62GGEP IN2 IN3 A2 RGC...90GGEP, RGC...92GGEP OUT IN1 A1 11+ 12-11+ 12- A1 11+ 12- A1 RG Solid State Switch CONTROL FAULT IN2 IN3 A2 IN2 IN3 A2 RGC...D9xGGEP RGC...A9xGGEP 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal (Positive supply in case of RGC1A..D9xGGEP) A2 (-): Control ground IN1: Control signal (only for RGC1A.. D9xGGEP) IN2: Fan + supply (only for RGC1A60A9xGGEP) IN3: Fan - supply (only for RGC1A60A9xGGEP) 11 + : Alarm output (+) OUT, 12 - : Alarm output (-) : Protective earth Housing width tolerance +0.5mm, -0mm as per DIN43880. All other tolerances ± 0.5mm. All dimensions in mm. Specifications are subject to change without notice (26.06.2015) 21

Connection Specifications POWER CONNECTIONS: 1/L1, 2 /T1 Use 75 C copper (Cu) conductors RGC...KKE ; RG..GKEP. ; RG...MKE RG...KGE ; RG...GGEP ; RG...MGE Stripping Length (X) 12mm 11mm Connection type M4 screw with captivated washer M5 screw with box clamp Rigid (Solid & Stranded) UL/ cul rated data X 2 x 2.5..6 mm 2 1 x 2.5..6 mm 2 1 x 2.5..25mm 2 2 x 14.. 10 AWG 1 x 14.. 10 AWG 1 x 14...3 AWG Flexible with end sleeve 2 x 1.0... 2.5mm 2 2 x 2.5..4mm 2 1 x 1.0..4mm 2 1 x 2.5..16mm 2 2 x 18.. 14 AWG 1 x 18.. 12 AWG 1 x 14.. 6 AWG 2 x 14.. 12 AWG Flexible without 2 x 1.0... 2.5mm 2 end sleeve 2 x 2.5.. 6mm 2 1 x 1.0.. 6mm 2 1 x 4.. 25mm 2 2 x 18.. 14 AWG 1 x 18.. 10 AWG 1 x 12.. 3 AWG 2 x 14.. 10 AWG Torque specifications Pozidriv 2 Posidriv 2 UL: 2Nm (17.7lb-in) UL: 2.5Nm (22lb-in) IEC: 1.5-2.0Nm (13.3-17.7lb-in) IEC: 2.5-3.0Nm (22-26.6lb-in) Aperture for termination lug 12.3mm N/A Protective Earth (PE) Connection M5, 1.5Nm (13.3 in-lb) Note: M5 PE screw not provided with SSR. PE connection required when product is intended to be used in Class 1 applications according to EN/IEC 61140. CONTROL CONNECTIONS: A1(+), A2(-) Use 60/75 C copper (Cu) conductors RG...KKE, RG..KGE RG...MKE, RG...MGE Torque specifications M3, Pozidriv 1 UL: 0.5Nm (4.4lb-in) IEC: 0.5-0.6Nm (4.4-5.3lb-in) Stripping Length (X) 8mm 12-13mm Rigid (Solid & Stranded) UL/ cul rated data X 2 x 0.5..2.5mm 2 1 x 0.5..2.5mm 2 1 x 0.2...2.5mm 2 2 x 18..12 AWG 1 x 18..12 AWG 1 x 24...12 AWG Flexible with end sleeve 2 x 0.5..2.5mm 2 1 x 0.5..2.5mm 2 2 x 18..12AWG 1 x 18..12AWG CONTROL CONNECTIONS: A1(+), A2(-), IN1, IN2, IN3, 11 (+), 12(-), OUT Use 60/75 C copper (Cu) conductors RG...GGEP Torque specifications M3, Pozidriv 1 UL: 0.5Nm (4.4lb-in) IEC: 0.4-0.5Nm (3.5-4.4lb-in) Stripping Length (X) 6mm 6mm Rigid (Solid & Stranded) UL/ cul rated data X Flexible with end sleeve 2 x 1.0..2.5mm 2 1 x 1.0..2.5mm 2 2 x 18..14 AWG 1 x 18..14 AWG 2 x 1.0..2.5mm 2 1 x 1.0..2.5mm 2 2 x 18..14 AWG 1 x 18..14AWG 22 Specifications are subject to change without notice (26.06.2015)

Installation Instructions Y1 = 50mm 20mm X X = X Refer = 20mm to Derating vs. Spacing Curves 20mm X Y2 = 100mm Mounting on DIN rail Dismounting from DIN rail 50mm Short Circuit Protection Protection Co-ordination, Type 1 vs Type 2: Type 1 protection implies that after a short circuit, the device under test will no longer be in a functioning state. In type 2 co-ordination the device under test will still be functional after the short circuit. In both cases, however the short circuit has to be interrupted. The fuse between enclosure and supply shall not open. The door or cover of the enclosure shall not be blown open. There shall be no damage to conductors or terminals and the condcutors shall not separate from terminals. There shall be no breakage or cracking of insulating bases to the extent that the integrity of the mounting of live parts is impaired. Discharge of parts or any risk of fire shall not occur. The product variants listed in the table hereunder are suitable for use on a circuit capable of delivering not more than 100,000A rms Symmetrical Amperes, 600 Volts maximum when protected by fuses. Tests at 100,000A were performed with Class J fuses, fast acting; please refer to the table below for maximum allowed ampere rating of the fuse. Use fuses only. Tests with Class J fuses are representative of Class CC fuses. Co-ordination type 1 (UL508) Part No. Prospective short Max. fuse size [A] Class Voltage [VAC] circuit current [karms] RGC..15 100 30 J or CC max. 600 RGC..20 100 30 J or CC max. 600 RGC..25 100 30 J or CC max. 600 RGC..30 100 30 J or CC max. 600 RGC..40 100 40 J max. 600 RGC..42 100 90 J max. 600 RGC..60 100 40 J max. 600 RGC..62 100 90 J max. 600 RGC..90 100 40 J max. 600 RGC..92 100 90 J max. 600 Specifications are subject to change without notice (26.06.2015) 23

Co-ordination type 2 (IEC/EN 60947-4-2/ -4-3) Part No. Prospective short Ferraz Shawmut Siba Voltage [VAC] circuit current Max fuse Max fuse [karms] size [A] Part number size [A] Part number RGC..15 10 25 6.9xx CP GRC 14x51 /25 32 50 142 06.32 max. 600 100 25 6.9xx CP GRC 14x51 /25 32 50 142 06.32 max. 600 RGC..20 10 40 6.6xx CP URD 22x58 /40 32 50 142 06.32 max. 600 100 40 6.6xx CP URD 22x58 /40 32 50 142 06.32 max. 600 RGC..25 10 40 6.9xx CP GRC 22x58 /40 32 50 142 06.32 max. 600 100 40 6.6xx CP URD 22x58 /40 32 50 142 06.32 max. 600 RGC..30 10 40 6.9xx CP GRC 22x58 /40 32 50 142 06.32 max. 600 100 40 6.6xx CP URD 22x58 /40 32 50 142 06.32 max. 600 RGC..40 10 63 6.621 CP URGD 27x60 /63 63 50 194 20.63 max. 600 10 70 A70QS70-4 63 50 194 20.63 max. 600 100 63 6.621 CP URQ 27x60 /63 63 50 194 20.63 max. 600 RGC..42 10 63 6.9xx CP URC 14x51 /63 80 50 194 20.80 max. 600 10 70 A70QS70-4 80 50 194 20.80 max. 600 100 63 6.9xx CP URC 14x51 /63 80 50 194 20.80 max. 600 100 70 A70QS70-4 80 50 194 20.80 max. 600 RGC..60 10 80 6.621 CP URQ 27x60 /80 80 50 194 20.80 max. 600 up to 65AAC 100 n/a n/a 80 50 194 20.80 max. 600 RGC..62 10 100 6.9xx CP GRC 22x58 /100 100 50 194 20.100 max. 600 10 100 A70QS100-4 100 50 194 20.100 max. 600 100 100 6.621 CP URGD 27x60 /100 100 50 194 20.100 max. 600 100 100 A70QS100-4 100 50 194 20.100 max. 600 RGC..90 10 100 6.621 CP URQ 27x60 /100 100 50 194 20.100 max. 600 up to 80AAC 10 100 A70QS100-4 100 50 194 20.100 max. 600 100 n/a n/a 100 50 194 20.100 max. 600 RGC..92 10 125 6.621 CP URQ 27x60 /125 125 50 194 20.125 max. 600 10 125 A70QS125-4 125 50 194 20.125 max. 600 100 125 6.621 CP URQ 27x60 /125 125 50 194 20.125 max. 600 100 125 A70QS125-4 125 50 194 20.125 max. 600 24 Specifications are subject to change without notice (26.06.2015)

Type 2 Protection with Miniature Circuit Breakers (M.C.B.s) Solid State Relay ABB Model no. for ABB Model no. for Wire cross Minimum length of type Z - type M. C. B. B - type M. C. B. sectional area [mm2] Cu wire conductor [m] 13 (rated current) (rated current) RGC..15, RGC..20 RGC..25, RGC..30 1 pole S201 - Z4 (4A) S201 - B2 (2A) 1.0 21.0 S201 - Z6 UC (6A) S201 - B2 (2A) 1.0 21.0 1.5 31.5 1 pole S201 - Z10 (10A) S201-B4 (4A) 1.0 7.6 1.5 11.4 2.5 19.0 S201 - Z16 (16A) S201-B6 (6A) 1.0 5.2 1.5 7.8 2.5 13.0 4.0 20.8 S201 - Z20 (20A) S201-B10 (10A) 1.5 12.6 2.5 21.0 S201 - Z25 (25A) S201-B13 (13A) 2.5 25.0 4.0 40.0 2 pole S202 - Z25 (25A) S202-B13 (13A) 2.5 19.0 4.0 30.4 RGC..40 RGC..60 RGC..90GGEP 1 pole S201 - Z25 (25A) S201-B13 (13A) 2.5 7.0 4.0 11.2 6.0 16.8 1 pole S201 - Z25 (25A) S201-B13 (13A) 2.5 7.0 4.0 11.2 6.0 16.8 1 pole S201 - Z20 (20A) S201-B10 (10A) 1.5 4.2 2.5 7.0 4.0 11.2 S201 - Z32 (32A) S201-B16 (16A) 2.5 13.0 4.0 20.8 6.0 31.2 2 pole S202 - Z20 (20A) S202-B10 (10A) 1.5 1.8 2.5 3.0 4.0 4.8 S202 - Z32 (32A) S202-B16 (16A) 2.5 5.0 4.0 8.0 6.0 12.0 10.0 20.0 S202 - Z50 (50A) S202-B25 (25A) 4.0 14.8 6.0 22.2 10.0 37.0 RGC..42, RGC..62, RGC..92 1 pole S201-Z32 (32A) S201-B16 (16A) 2.5 3.0 4.0 4.8 6.0 7.2 S201-Z50 (50A) S201-B25 (25A) 4.0 4.8 6.0 7.2 10.0 12.0 16.0 19.2 S201-Z63 (63A) S201-B32 (32A) 6.0 7.2 10.0 12.0 16.0 19.2 13. Between MCB and Load (including return path which goes back to the mains). Note: A prospective current of 6kA and a 230/400V power supply system is assumed for the above suggested specifications. For cables with different cross section than those mentioned above please consult Carlo Gavazzi's Technical Support Group. Specifications are subject to change without notice (26.06.2015) 25

Accessories Control Plugs Ordering Key Pack of 10 spring loaded control plugs RGM25 * Refer to Connection Specifications section for further details. 26 Specifications are subject to change without notice (26.06.2015)