VACUTAP VVS COMPACT ON-LOAD TAP-CHANGER FOR GRID APPLICATIONS.

Similar documents
On-load tap-changer VACUTAP VRD, VRF, VRG

VACUTAP VR On-Load Tap-Changer for Regulating Transformers

On-load tap-changer VACUTAP VRC and VRE

VACUTAP VR THE ALL-AROUND ON-LOAD TAP-CHANGER. TRANSFORMER CONTROL

PRODUCTS AND SOLUTIONS FOR A SMOOTH POWER SUPPLy. TRANSFORMER CONTROL

On-Load Tap Changer Type M

PRODUCTS & ACCESSORIES FOR DISTRIBUTION TRANSFORMERS.

ON LOAD TAP CHANGERS RS 6.3 / RS 6 TECHNICAL DATA

TRANSFORMER SERVICES OUR KNOWLEDGE. YOUR EXPERTS.

ON LOAD TAP CHANGERS RSV 5.3 TECHNICAL DATA

Load Tap Changers for Power Transformers

ON LOAD TAP CHANGERS RS 9.3 / RS 9 TECHNICAL DATA

Service by MR. Safety ex Works

24 th International Conference on Electricity Distribution Glasgow, June Paper 0881 ABSTRACT STATE OF THE ART INTRODUCTION ECOTAP VPD

TECHNICAL DATA TYPE CMD OIL-IMMERSED ON-LOAD TAP CHANGER

MR PUBLICATION. On-Load Tap-Changers for Power Transformers A Technical Digest

ECOTAP VPD THE COMPACT CLASS FOR DISTRIBUTION TRANSFORMERS.

Keywords: Power Transformer, On-load Tap Changer, AVR, Low Voltage Variation, Change Positions, OLTC Control.

INTERNATIONAL STANDARD

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

Documents and Addresses

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

TECHNICAL DATA TYPE SHZV VACUUM ON-LOAD TAP CHANGER FOR OIL-IMMERSED TRANSFORMER

Voltage Regulator TAPCON 230 basic. Quick reference guide /02

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TECHNICAL DATA TYPE CV & SV OIL-IMMERSED ON-LOAD TAP CHANGER

1ZSC AAJ en, Rev. 1. Vacuum on-load tap-changers, type VUBB Technical guide

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

GRIDCON ACF ACtIve FIlteRs FOR CleAN voltage AN ACtIve IMpACt IN the GRID. power QuAlIty

Tatjana Šimović a *, Marko Stanić a, Laurenc Kirchner b

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Variable Shunt Reactors. Johann Griebichler I EM TR LPT GTC

Comparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

About us. Vision. To lead our field in innovation, quality and customer service.

1ZSE en, Rev. 6. On-load tap-changers, type UBB Technical guide

TAP CHANGER SELECTING MANUAL TECHNICAL DATA

Regional Technical Seminar

Diagnostic testing of cast resin transformers

Regional Technical Seminar TAP CHANGERS

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

1ZSE en, Rev. 9. On-load tap-changers, type UC and VUC Technical guide

Substation Preventive Maintenance

APPARENT POWER DEPENDENT VOLTAGE CONTROL IN THE LV GRIDS WITH DISTRIBUTED GENERATION USING ON-LOAD TAP CHANGING TRANSFORMER

Pomona, CA May 24 & 25, LTC Applications - Location, Series & Preventative Auto Transformers

Comparative analysis of on-load tap changing (OLTC) transformer topologies

Register now to make sure you have a place: Contact:

Hands-On Transformer Testing and Maintenance

Vacuum Interrupters for Medium Voltage

Mobile Power Transformer Test Systm

Repair & Retrofit new life for old transformers. Repair and retrofitting through TLM Transformer Lifecycle Management. Answers for energy.

La protection sélective des réseaux électriques

1ZSC AAW en, Rev. 2. On-load tap-changers, type UC Technical guide

The Weidmann Conference The Aging of America s Transformers

On-load tap-changers, type UC and VUC Technical guide

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Capacitive voltage transformers

Semiconductor (AC) fuses

A compact, integrated solution for medium voltage connection, transformer and low voltage distribution

Medium-voltage in-phase regulator system Energy Management

Technical guide. Type VRLTC load tap changer

DIFFERENCE BETWEEN SWITCHING OF MOTORS & GENERATORS WITH VACUUM TECHNOLOGY

Onsite Mobile AC High Voltage Test System

Tap Changer Condition Assessment Using Dynamic Resistance Measurement

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström

Protection of low power mains against pulse power of natural lightning using spark gap arresters. Abstract

CAST RESIN DRY TRANSFORMER

POWER TRANSFORMERS CATALOGUE

Technical guide. Type VRLTC load tap changer

Energy Division. Bowthorpe LV/MV Surge Arresters

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Inductive Voltage Transformers. Types VEOT and VEOS

Center for Quality Engineering. Test Report No.: B0EF0002

gridcon TransforMer The voltage regulated DisTribuTion TransforMer. power DisTribuTion. smart grid lösungen

Center for Quality Engineering. Test Report No.: B0JA0002

TECHNICAL INFORMATION

MEDIUM & HIGH VOLTAGE

Introduction. Centrado leading-edge transformer. Introduction

Liquid-Filled Transformers

Power Engineering II. High Voltage Testing

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Power Transformer Condition Assessment Based on Standard Diagnosis

StarSine Power Quality Products

Current Transformers. Type OSKF

OIL-IMMERSED ARC-SUPPRESSION COILS

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

SPECIFICATION No SS-88/5 630 kva, 30 / 0.4 kv THREE-PHASE TRANSFORMERS WITH ON-LOAD TAP CHANGER

Medium voltage circuit breaker technical guide

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

Transformer condition assessment with an integrated test van

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

FINDINGS AND REPAIR OF WESTINGHOUSE UTT AND McGRAW 550 TAP CHANGERS

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Combined Instrument Transformers. Types IVOKT and TMC

Technical Information Requirement for MV Transformers and Transformer for Internal Power Supply for SUNNY CENTRAL

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT D

VOLTAGE OPTIMIZATION FOR INDUSTRY, TRADE, BUSINESS AND LOCAL NETWORKS

Transcription:

COMPACT ON-LOAD TAP-CHANGER FOR GRID APPLICATIONS. WWW.REINHAUSEN.COM

2

TAILORED FOR GRID APPLICATIONS. The vacuum on-load tap-changer was developed and optimized for operation in transformers up to approximately 60-70 MVA for 110 kv* power grids. Its compact design combines a diverter switch and tap selector in one functional unit. The is based on the well-proven VACUTAP VV and comprises a diverter switch and selector within the oil compartment. This compact design enables a spatially optimized configuration of the transformer and transformer cell. Maintenance-free for nearly all grid applications The vacuum-switching technology already proven in the VACUTAP VV ensures maximum reliability. The maintenance interval of 300,000 operations means maintenance-free performance for nearly all grid applications and therefore maximum availability of your transformers. This is made possible through features such as vacuum interrupters, which are developed in accordance with our strict requirements and have proven themselves in years of operation. No other manufacturer of tap changers has such a large number of vacuum on-load tap-changers in operation as Maschinenfabrik Reinhausen. Benefits of vacuum technology I Substantially reduced frequency of maintenance compared to conventional oil circuit engineering I No arcing in the tap-changer oil I No oil filter unit needed *voltage levels may vary by country 3

VERY COMPACT. MOST RELIABLE. The on-load tap-changers of the VACUTAP series combine decades of experience in vacuum-switching technology with the consistent further development of this technology. This results in on-load tap-changers with maximum reliability and availability. Flange for bell-type tank installation standard to simplify assembly Enhanced change-over selector capacity, usually no potential connection measure needed Internal integrated change-over selector I Optimized dimensions I No influence on the DGA values of the transformer Space saving in the transformer tank due to very compact dimensions designed for standard grid applications 4

TECHNICAL DATA. Installation length VVS III 400 Y On-load tap-changer VVS III 400 Y VVS III 400 D Number of phases 3 Max. rated through-current I r (A) 400 Rated short-time current (ka) 4 Rated duration of short-circuits (s) 3 1,345 Dimensions in mm 207 370 222 204 76 76 120 76 Change-over selector Rated peak withstand current (ka) 10 Max. rated step voltage U ir (V) 1,300 Step capacity P StN (kva) 400 Rated frequency (Hz) 50 to 60 Operating positions with change-over selector: max. 19 Motor-drive unit Rated insulation level VVS III 400 Highest voltage for equipment U m (kv) 40 or 76 Rated lightning impulse withstand voltage (kv, 1.2 50 µs) 200 or 350 TAPMOTION ED, ETOS ED Rated short-duration power frequency withstand voltage (kv, 50 Hz, 1 min.) 70 or 140 Installation length VVS III 400 D 370 Change-over selector III 400 step capacity diagram 120 1400 1200 1,800 Dimensions in mm 382 382 342 204 76 76 76 Rated step voltage U ir (V) 1000 800 600 400 200 0 VVS 400 0 100 200 300 400 500 Rated through-current I r (A) 5

6

HIGH QUALITY. LOW LIFE-CYCLE COSTS. For reliable, economical operation. Maintenance-free and long-lasting I Maintenance interval of 300,000 tap-changes without time-based components I Maintenance free for nearly all grid applications Maximum operational reliability I In our globally unique testing department, our on-load tap-changers are tested over all technical limits I No other manufacturer of tap-changers has such a large number of vacuum on-load tap-changers in operation worldwide Low life-cycle costs I With this product we offer the best price-performance ratio I Maintenance-free in most cases during the transformer life time Compact design I The innovative design is especially well-suited for applications with little available space I The integrated change-over selector enables a more effective transformer design that uses less material 7

Maschinenfabrik Reinhausen GmbH Falkensteinstrasse 8 93059 Regensburg, Germany Phone: +49 941 4090-0 Fax: +49 941 4090-7001 E-mail: info@reinhausen.com www.reinhausen.com Please note: The data in our publications may differ from the data of the devices delivered. We reserve the right to make changes without notice. IN5671730/01 EN F0351401 01/19 uw Maschinenfabrik Reinhausen GmbH 2017