Product Data Sheet 6424/2HP-210

Similar documents
Product Data Sheet 8452/2 GHHP

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 8214 J/2H4P

Product Data Sheet DV4112/2NP-201

Product Data Sheet 3254 J/2H3P

Product Data Sheet 622/2HHP-021

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 3252J/2H3PU

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet RER225-63/18/2TDO- 406

EC centrifugal fan - RadiCal

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

EC centrifugal fan - RadiCal

-1 ] temperature life [V]

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

B1793 AC Blower Innovation in Motion

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

AC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

AC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. backward curved, single inlet

2-02 Start voltage The voltage that enable to start the fan by sudden switch on.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

DC axial compact fan

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

AC diagonal compact fan

AC axial compact fan

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

EC centrifugal fan - RadiCal

Specification For Approval

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

DB Motorized Impeller

Specification For Approval

Specification For Approval

CONTENTS 1. SCOPE 3 2. ELECTRICAL 3 3. MATERIAL 4 4. MECHANICAL NOISE MEASUREMENT RELIABILITY PRODUCT LABEL...

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

9WL type. Rated current Rated input. Rated speed [min -1 ]

SPECIFICATION FOR APPROVAL

DB Motorized Impeller

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

NEW PRODUCT INFORMATION

AC centrifugal fan. backward curved

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan - RadiCal

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

DB Motorized Impeller

CUSTOMER: ARCERA EU MODEL NO: 9225 (CeraDyna Fan) PART NO: FD1290-AP181E3AL DATE: CUSTOMER APPROVAL. Taiwan. Page 1 of 12 REV.

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

175 mm 69 mm Specifications

EC centrifugal fan. backward curved, single inlet

V: Very low speed, E: Extra low speed, L: Low speed, M: Middle speed, H: High speed, S: Super High speed, U: Ultra High speed, T: Top High speed

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

NEW PRODUCT INFORMATION

onlinecomponents.com

Transformers, Power Supply Units and Socket Outlets

Rotary Measurement Technology Incremental Encoders

AC axial compact fan

Tangential blowers with multiple housings. Optimized air flow steady distribution.

SPECIFICATION FOR APPROVAL

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Power Supplies 3. SDN-C Compact DIN Rail Series

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Technical Data. General specifications. Rated operating distance s n 3 mm

MODEL: M2DYS SEN TRONIC AG

KFS. Flap-type flow meter. Design and range of application

SPECIFICATION FOR APPROVAL

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

Automotive BL-DC Fans for Commercial Vehicles. Edition

Specification For Approval

Technical guide. EC300 motor V8

DC Axial Fans. ebm-papst St. Georgen. Noise

Power supply CP-D 24/4.2 Primary switch mode power supply

Refrigerated Products Brochure. USA Edition

WL Product Range Performance Comparison

SPECIFICATION FOR APPROVAL

Tangential Fans - Basic principles. Expertise, performance, innovation

DC Axial Fans. ebm-papst St. Georgen. Ball Bearings. Noise

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Transcription:

6424/2HP-210 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data... 5 3.3 Operating Data - Electrical Interface -Output... 6 3.4 Electrical Features... 7 3.5 Aerodynamic... 8 3.6 Sound Data... 8 4 Environment... 9 4.1 General... 9 4.2 Climatic requirements*)... 9 5 Safety... 10 5.1 Electrical Safety... 10 5.2 Approval Tests... 10 03/09/2015 page 2 of 11

1 General Fan type Rotational direction looking at rotor Airflow direction Bearing system Mounting position Fan counterclockwise Air outlet over struts Ball bearing any 2 Mechanics 2.1 General Width Depth Diameter Weight Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 150,0 mm 51,0 mm 172,0 mm 0,760 kg Metal Plastic wire outlet corner: 260 Ncm remaining corners: 260 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Wires - Plug Length of lead wire Wire gauge (AWG) 22 Insulation diameter 1,70 mm Contact see drawing Colour Operation Wire 1 red + UB Wire 2 blue - GND Wire 3 violet PWM Wire 4 white Tacho The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. 03/09/2015 page 3 of 11

3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input PWM Features PWM - Frequency 1 khz - 10 khz Typical: 2 khz Characteristics Schematics Speed control: 0... 100% PWM; f: 2 khz; open collector Alternatively: Resistor to GND (33 mw) 0... oo kohm Transistor reqirements: V CE sat< 0,15 V; V CE max. 12 V; I sink max. 5 ma 03/09/2015 page 4 of 11

3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).in the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see section 3.5) I: corresp. to arithm. mean current value Name Condition PWM 0001 PWM: 100 %; Features Condition Symbol Values Voltage range p = 0 U 12,0 V 28,0 V Nominal voltage p = 0 U N 24,0 V Power consumption p = 0 7,0 W 31,4 W 35,6 W P +- 15,0 % +- 12,0 % +- 10,0 % PWM 0001 Current consumption p = 0 580 ma 1.310 ma 1.270 ma I +- 15,0 % +- 12,0 % +- 10,0 % PWM 0001 Speed p = 0 2.280 1/min 4.270 1/min 4.410 1/min n +- 15,0 % +- 12,0 % +- 10,0 % PWM 0001 Starting current consumption 1.800 ma Inrush current 5.500 ma 100% PWM; f: 2 khz or broken control lead (open control input) Name Condition PWM 0002 PWM: 50 %; Features Condition Symbol Values Voltage range p = 0 U 12,0 V 28,0 V Nominal voltage p = 0 U N 24,0 V Power consumption p = 0 5,0 W 5,5 W 5,9 W P +- 15,0 % +- 12,0 % +- 10,0 % PWM 0002 Current consumption p = 0 420 ma 230 ma 210 ma I +- 15,0 % +- 12,0 % +- 10,0 % PWM 0002 Speed p = 0 1.970 1/min 2.000 1/min 2.010 1/min n +- 15,0 % +- 12,0 % +- 12,0 % PWM 0002 03/09/2015 page 5 of 11

3.3 Operating Data - Electrical Interface -Output Tacho type /2 (Open collector) Features Note Values Tacho operating voltage (UBS) <= 60 V Tacho signal Low I sink: 2 ma <= 0,4 V Tacho signal High I source: 0 ma <= 60 V Maximum sink current <= 20 ma External resistor External resistor Ra from UBS to US required. All voltages measured to GND. Tacho frequency (2 x n) / 60 Tacho isolated from motor No Slew rate => 0,5 V/us Alarm type None 03/09/2015 page 6 of 11

3.4 Electrical Features Electronic function Reversed polarity protection Max. residual current at Un Locked rotor protection Locked rotor current at Un Clock signal t3/t4 at locked rotor Speed-Controlled Rectifying diode IF <= 10 ma Auto restart approx. 2.500 ma Typical: 0,5 s / 5,0 s 03/09/2015 page 7 of 11

3.5 Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 4.270 1/min at free air flow PWM 100 %; Max. free-air flow ( p = 0 / = max.) 490,0 m3/h Max. static pressure ( p = max. / =0) 245 Pa 3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see section 3.5 a.) Operation condition: 4.270 1/min at free air flow Optimal operating point PWM 100 % PWM min.: PWM max.: 325,0 m3/h @ 100 Pa Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 7,0 bel(a) 62,0 db(a) 03/09/2015 page 8 of 11

4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 72 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic requirements*) Humidity requirements humid heat, constant; according to DIN EN 60068-2- 78, 14 days Water exposure None Dust requirements None Salt fog requirements None *) Permittet application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.please require severity levels and specification parameters from the responsible development departments 03/09/2015 page 9 of 11

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. clearance / creepage distance Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE Association for Electrical, Electronic and Information Technologies Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment CSA Canadian Standards Association Yes / C22.2 No. 113 Fans and Ventilators CCC China Compulsory Certification No 03/09/2015 page 10 of 11