Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

Similar documents
General information. Supply voltage

Product type designation. General information. Supply voltage

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

CPU 314C-2 PTP. Function

2A (recommended) Power loss

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet CPU 313SC (313-5BF13)

Data sheet CPU 013C (013-CCF0R00)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

General specifications and features

FM HIGH-SPEED BOOLEAN PROCESSOR

FM COUNTER MODULE

FM 355 CONTROLLER MODULE

General information. CiR - Configuration in RUN

FM COUNTER MODULE

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

EXM INPUT/OUTPUT EXPANSION

Zentralbaugruppen CPU 222

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

SM 1222 DIGITAL OUTPUT MODULE

SM 1223 DIGITAL INPUT/OUTPUT MODULE

SIMATIC S7-300 Function modules

General information. CiR - Configuration in RUN

FM COUNTER MODULE

Product Information. Release 3 4 SIMATIC ET 200S. 4DI UC V High Feature Digital Electronic Module

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

FM POSITIONING MODULE

PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Q.raxx A101-8 slimline RS / EC

Q.raxx A slimline RS / EC Universal Measurement System

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Q.raxx A slimline RS / EC

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

em4 local - Robust Specific characteristics Part number

em4 em4 alert em4 alert 2G

Outputs U8 I1. Protection class IP64 (IP67) WB25

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Outputs U8 I1. Protection class IP64 (IP67) WB25KT

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

8V General information. 2 Order data 8V

This data sheet is only valid in association with the IL SYS INST UM E user manual.

S7-200 SMART Programmable controller Answers for industry.

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

SIMATIC. ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB52-0AB0) Preface. Properties 1. Parameters 2.

XIOC technology and networking modules

EM 6000 EM 6000 DANTE True bit diversity receiver

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

8V General information. 2 Order data 8V

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

Ultra flat POSICHRON position sensor. Current Resolution

Analog Inputs and Outputs

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Analog input module. AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1) SIMATIC. ET 200SP Analog input module AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1)

Ranges >500 mm: L10 = ±0.10 % f.s. L02 = ±0.02 % f.s. Ranges 500 mm: L10 = ±0.5 mm L02MM = ±0.2 mm Repeatability ±3 µm

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

DAB+ Voice Break-In Solution

Protection class U8 I1. Linearity ±0.10 % f. s. (standard); optional ±0.05 % WB10ZG

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

Protection class U8 I1. Linearity ±0.10 % f. s. (standard); optional ±0.05 % WB10ZG

Analog Input Module. AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0)

Pulse Scaler for DIN Rail Attachment

Totalizing Counters mini-i

Technical Data: Model:EXM-12DC-DA-R-4G

MULTIFUNCTION GRAPHICAL UNIT MGU 800

U8 I1. Linearity ±0.10 % f. s. (standard); optional ±0.05 % WB61

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

Positioning drives DC motor, brushless Absolute multiturn position detection, Profibus-DP

U8 I1. Linearity ±0.10 % f. s.; optional ±0.05 % WB12

Technical Data: Model:EXM-12DC-DAI-R

Digital Input Output Module for Zone 1 Series 9470/32

Protection class. Male 8 pin socket M12 (ADCANOP: 5 pin socket)

Industrial Modbus I/O Modules

ADTECH Solar inverter

SIMATIC. ET 200SP Analog Input Module AI 4xU/I 2-wire ST (6ES7134-6HD01-0BA1) Preface. Documentation guide. Product overview.

maxon document number:

GPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards

2CSG445013D0201 M2M PROFIBUS. Profibus DP interface user manual M2M ABB

7.2 DV1311.L08 and DV1311.L12

Digital Input Output Module for Zone 2 Series 9470/33

Absolute multi-turn hollow shaft encoder BOMH Dignalizer SSI

Magnetic absolute multi-turn hollow shaft encoder BMMH MAGRES SSI

PACSystems* RX3i IC695MDL765

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

SIMATIC. ET 200SP Analog Input Module AI 4xI 2-/4-wire ST (6ES7134-6GD01-0BA1) Preface. Documentation guide. Product overview.

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles Life cycle of bearings

Transcription:

6ES7313-6CF03-0AB0 SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD REQUIRED Product type designation General information Hardware product version 01 Firmware version V2.6 Engineering with Programming package STEP 7 V5.3 SP2 or higher with HW update Supply voltage 24 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) External protection for supply cables (recommendation) 20.4 V 28.8 V Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A Load voltage L+ Rated value (DC) permissible range, lower limit (DC) permissible range, upper limit (DC) 24 V 20.4 V 28.8 V

Digital inputs Load voltage L+ Rated value (DC) 24 V Reverse polarity protection Digital outputs Load voltage L+ Rated value (DC) 24 V Reverse polarity protection Input current Current consumption (rated value) Current consumption (in no-load operation), typ. Inrush current, typ. I²t from supply voltage L+, max. 900 ma 100 ma 11 A 0.7 A² s 900 ma Digital inputs from load voltage L+ (without load), max. 70 ma Digital outputs from load voltage L+, max. 100 ma Power losses Power loss, typ. 10 W Memory Type of memory other Work memory Integrated expandable 64 kbyte Load memory pluggable (MMC) pluggable (MMC), max. 8 Mbyte

Data management on MMC (after last programming), min. 10 y Backup present without battery ; Guaranteed by MMC (maintenance-free) ; Program and data CPU processing times for bit operations, typ. 0.1 µs for bit operations, max. 0.2 µs for word operations, typ. 0.2 µs for fixed point arithmetic, typ. 2 µs for floating point arithmetic, typ. 3 µs CPU-blocks Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. DB Number, max. 511; Number range: 1 to 511 Size, max. 16 kbyte FB Number, max. 1 024; Number range: 0 to 2047 Size, max. 16 kbyte FC Number, max. 1 024; Number range: 0 to 2047 Size, max. 16 kbyte OB Size, max. 16 kbyte Number of free cycle OBs 1; OB 1 Number of time alarm OBs 1; OB 10 Number of delay alarm OBs 1; OB 20

Number of time interrupt OBs 1; OB 35 Number of process alarm OBs 1; OB 40 Number of DPV1 alarm OBs 3; OB 55, 56, 57 Number of startup OBs 1; OB 100 Number of asynchronous error OBs 5; OB 80, 82, 85, 86, 87 Number of synchronous error OBs 2; OB 121, 122 Nesting depth per priority class 8 additional within an error OB 4 Counters, timers and their retentivity S7 counter Number 256 of which retentive without battery can be set lower limit 0 upper limit 255 preset 8 Retentivity can be set lower limit 0 upper limit 255 preset 8 Counting range lower limit 0 upper limit 999 IEC counter present Type Number SFB Unlimited (limited only by RAM

capacity) S7 times Number 256 of which retentive without battery can be set lower limit 0 upper limit 255 Retentivity can be set lower limit 0 upper limit 255 preset retentivity Time range lower limit 10 ms upper limit 9 990 s IEC timer present Type Number SFB Unlimited (limited only by RAM capacity) Data areas and their retentivity retentive data area, total all Flag Number, max. 256 byte Retentivity available ; MB 0 to MB 255 Retentivity preset MB 0 to MB 15 Number of clock memories 8; 1 memory byte Data blocks Number, max. 511; Number range: 1 to 511

Size, max. Retentivity adjustable Retentivity preset 16 kbyte ; via non-retain property on DB Local data per priority class, max. 510 byte Address area I/O address area Inputs Outputs 1 kbyte 1 kbyte of which, distributed Inputs 1 006 byte; max. Outputs 1 006 byte; max. Process image Inputs Outputs 128 byte 128 byte Default addresses of the integrated channels Digital inputs 124.0 to 125.7 Digital outputs 124.0 to 125.7 Digital channels Inputs 8 064 Outputs 8 064 Inputs, of which central 1 008 Outputs, of which central 1 008 Analog channels Inputs 503 Outputs 503 Inputs, of which central 248 Outputs, of which central 248

Hardware configuration Expansion devices, max. 3 Number of DP masters Integrated 1 Via CP 4 Number of operable FMs and CPs (recommended) FM 8 CP, point-to-point 8 CP, LAN 6 Rack Racks, max. 4 Modules per rack, max. 8; In rack 3 max. 7 Time of day Clock Hardware clock (real-time clock) battery-backed and synchronizable Deviation per day, max. Backup time 10 s 6 wk Operating hours counter Number 1 Number/Number range 0 Range of values Granularity retentive 0 to 2^31 hours (when using SFC 101) 1 hour Clock synchronization supported to MPI, master to MPI, slave

to DP, master to DP, slave in AS, master ; With DP slave only slave clock Digital inputs Number of digital inputs 16 of which, inputs usable for technological functions 12 integrated channels (DI) 16 Input characteristic curve in accordance with IEC 61131, type 1 Number of simultaneously controllable inputs horizontal installation up to 40 C, max. 16 up to 60 C, max. 8 vertical installation up to 40 C, max. 8 Input voltage Rated value (DC) 24 V for signal "0" -3 to +5V for signal "1" 15 to 30 V Input current for signal "1", typ. 9 ma Input delay (for rated value of input voltage) for standard inputs Parameterizable ; 0.1 / 0.3 / 3 / 15 ms Rated value 3 ms for counter/technological functions at "0" to "1", max. 16 µs Cable length

Cable length, shielded, max. Cable length unshielded, max. 1 000 m; 100 m for technological functions 600 m; For technological functions: Technological functions shielded, max. 100 m Unshielded, max. not allowed Standard DI shielded, max. 1 000 m Unshielded, max. 600 m Digital outputs Number of digital outputs 16 of which high-speed outputs 4 integrated channels (DO) 16 short-circuit protection Response threshold, typ. ; Clocked electronically 1 A Limitation of inductive shutdown voltage to L+ (-48 V) Controlling a digital input Switching capacity of the outputs Lamp load, max. 5 W Load resistance range lower limit upper limit 48 Ω 4 kω Output voltage for signal "1", min. L+ (-0.8 V) Output current for signal "1" rated value for signal "1" permissible range, min. for signal "1" permissible range, max. 500 ma 5 ma 0.6 A

for signal "1" minimum load current for signal "0" residual current, max. 5 ma 0.5 ma Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. of the pulse outputs, with resistive load, max. 100 Hz 0.5 Hz 100 Hz 2.5 khz Aggregate current of outputs (per group) horizontal installation up to 40 C, max. 3 A up to 60 C, max. 2 A vertical installation up to 40 C, max. 2 A Cable length Cable length, shielded, max. Cable length unshielded, max. 1 000 m 600 m Analog inputs Integrated channels (AI) 0 Analog outputs Integrated channels (AO) 0 Encoder Connectable encoders 2-wire sensor Permissible quiescent current (2-wire sensor), max. 1.5 ma

Interfaces Number of USB interfaces 0 Number of parallel interfaces 0 Number of 20 ma interfaces (TTY) 0 Number of RS 232 interfaces 0 Number of RS 422 interfaces 0 Number of other interfaces 0 MPI Cable length, max. 50 m; without repeater 1st interface Interface type Integrated RS 485 interface Physics RS 485 Isolated Power supply to interface (15 to 30 V DC), max. 200 ma Functionality MPI DP master DP slave Point-to-point connection MPI Number of connections 8 Transmission rate, max. 187.5 kbit/s Services PG/OP communication Routing Global data communication S7 basic communication S7 communication S7 communication, as client

2nd interface S7 communication, as server Interface type Integrated RS 485 interface Physics RS 485 Isolated Power supply to interface (15 to 30 V DC), max. 200 ma Number of connection resources 8 Functionality MPI DP master DP slave PROFINET IO Controller PROFINET CBA Point-to-point connection DP master Number of connections, max. Transmission rate, max. 8; For PG/OP communication 12 Mbit/s Number of DP slaves, max. 32 Services PG/OP communication Routing Global data communication S7 basic communication ; I blocks only S7 communication S7 communication, as client S7 communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE

Activation/deactivation of DP slaves Direct data exchange (slave-to-slave communication) DPV1 Address area Inputs, max. 1 kbyte Outputs, max. 1 kbyte User data per DP slave Inputs, max. 244 byte Outputs, max. 244 byte DP slave Number of connections 8 GSD file Transmission rate, max. Automatic baud rate search The latest GSD file is available at: http://www.siemens.com/profibus-gsd 12 Mbit/s ; only with passive interface Address area, max. 32 User data per address area, max. 32 byte Services PG/OP communication Routing ; Only with active interface Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Direct data exchange (slave-to-slave communication) DPV1 Transfer memory

Inputs 244 byte Outputs 244 byte Communication functions PG/OP communication Global data communication supported Number of GD loops, max. 4 Number of GD packets, max. 4 Number of GD packets, transmitter, max. 4 Number of GD packets, receiver, max. 4 Size of GD packets, max. Size of GD packet (of which consistent), max. 22 byte 22 byte S7 basic communication supported User data per job, max. User data per job (of which consistent), max. 76 byte 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) S7 communication supported as server As client User data per job, max. User data per job (of which consistent), max. ; Via CP and loadable FB 180 kbyte; With PUT/GET 64 byte S5-compatible communication supported ; via CP and loadable FC Number of connections overall 8

usable for PG communication 7 reserved for PG communication 1 Adjustable for PG communication, min. 1 Adjustable for PG communication, max. 7 usable for OP communication 7 reserved for OP communication 1 adjustable for OP communication, min. 1 adjustable for OP communication, max. 7 usable for S7 basic communication 4 Reserved for S7 basic communication 0 adjustable for S7 basic communication, min. adjustable for S7 basic communication, max. usable for routing 0 4 4; max. S7 message functions Number of login stations for message functions, max. Process diagnostic messages 8 simultaneously active Alarm-S blocks, max. 20 Test commissioning functions Status block Single step Number of breakpoints 2 Status/control Status/control variable Variables Inputs, outputs, memory bits, DB, times, counters Number of variables, max. 30

of which status variables, max. 30 of which control variables, max. 14 Forcing Forcing Force, variables Inputs, outputs Number of variables, max. 10 Diagnostic buffer present Number of entries, max. 100 can be set Interrupts/diagnostics/status information Diagnostics indication LED Status indicator digital output (green) Status indicator digital input (green) Integrated Functions Number of counters Counter frequency (counter) max. Frequency measurement Number of frequency meters controlled positioning Integrated function blocks (closed-loop control) PID controller Number of pulse outputs Limit frequency (pulse) 3; 3 channels (see "Technological Functions" manual) 30 khz 3; 3 channels up to max. 30 khz (see "Technological Functions" manual) PID controller (see "Technological Functions" manual) 3; 3 channels pulse width modulation up to max. 2.5 khz (see "Technological Functions" manual) 2.5 khz Galvanic isolation

Galvanic isolation digital inputs Galvanic isolation digital inputs between the channels between the channels and the backplane bus Galvanic isolation digital outputs Galvanic isolation digital outputs between the channels between the channels, in groups of 8 between the channels and the backplane bus Permissible potential difference between different circuits 75 VDC / 60 VAC Isolation Isolation checked with 600 V DC Configuration Configuration software STEP 7 ; V5.3 SP2 with HW update programming Command set see instruction list Nesting levels 8 System functions (SFC) System function blocks (SFB) see instruction list see instruction list Programming language LAD FBD STL SCL GRAPH

HiGraph Know-how protection User program protection/password protection Dimensions Width Height Depth 120 mm 125 mm 130 mm Weights Weight, approx. 566 g last modified: 13.10.2014