INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

Similar documents
INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-42 AC MD-42 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-34 AC LD-34 DC

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-44 AC MD-44 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

INSTALLATIONSANVISNING INSTALLATION MANUAL MA-44/MA-44DC OMVANDLARE RS RS-422/485 CONVERTER RS RS-422/485. Balanced Transmission

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

User Guide. Westermo Teleindustri AB 2004 REV.A MDW Converter RS-232 RS-422/485.

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

FOM-5A, 6A Asynchronous Fiber Optic Modems

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

MDW-45 Converter RS RS-422/485

Concept of Serial Communication

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Interface converter G kbit/sec

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

This FAQ covers Single Direction use of current loop with transmitting devices.

User Guide Westermo Teleindustri AB TR-36. Tele and leased line modem for RV rack system.

This FAQ covers the common questions from technicians installing these converters.

Universal RS232/CMOS to RS422/RS485 Converter

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

Miniature Synchronous Multipoint Modems

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

M9606. FSK Modem. 5C Communications Inc.

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

Intermittent Vibration 0.075

Cable and Port Specifications

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA

MODEL: DLS. Telemetering System

Telemetrie-Messtechnik Schnorrenberg

ZCS485 User s Manual. Version ZYPEX, Inc.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Voice-Frequency Telegraph Modem HY101-SWT

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

User Manual CTP4/8/16

User Guide. Westermo Teleindustri AB 2006 IDW ISDN Terminaladapter.

M-Bus Master MultiPort 250L Installation and User Guide

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

USER'S MANUAL. Model : K

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

KiloStream Data Sheet

Chapter 12: Digital Modulation and Modems

ANALOG AND DIGITAL PHYSICAL INTERFACES

9600 bps, Dual Modem 170 Card Private Wire Only

USER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)

Lecture #3 RS232 & 485 protocols

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

Integrity Instruments

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

MGE TM Galaxy TM , 60 Hz kva

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

User Guide Westermo Teleindustri AB IDW-90. ISDN Terminaladapter.

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

1 What s in the shipping package?

Stat-4 Stat-8 Stat-24

FOM-4SF Sync/Async Single Fiber Modem

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Add/Drop Multiplexor/Demultiplexor

SIN 57 Issue 2.4 May 2018

CP485-4 User s Manual

Fanuc Serial (RS232) Communications Information

APPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC)

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

E205 Long Range Wireless Modem V1.0 Data Sheet

CAB2 Schematic drawing CAB3 CAB4 CAB5. CAB6 Schematic drawing CAB7 Schematic drawing CAB8 Schematic drawing 03315

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Dual band E-GSM / GPRS Class 10 / GPS MODEM. GENLoc25. Electronic Hardware Design and Production

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

High-precision process calibrator Model CED7000

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Atrie WireSpan 600/610 MODEM User's Manual

DA 30 High Torque Technical Specification

ECE 4510/5530 Microcontroller Applications Week 6 Lab 5

CROSS Chassis from 160 A to 450 A

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Installation Instructions. RFID MHz Interface Board for EasyCoder F2 and F4 Printers

DECODE. User Manual v1.2n. Multi-standard modem IDM 50B.

TD-36 TD-36. DIN-rail Tele and Leased Line modem TD DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

LDM85. Fiber Optic Modem. Description. Features. Specifications

1.0 Introduction. Related Products and Documentation

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

Transcription:

INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 0-00 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem Short Haul Modem Kurzstreckenmodem www.westermo.se

Specifications Transmission Asynchronous Full/half duplex or simplex Interface EIA RS--C/CCITTV., V. -pin D-sub, female DCE Interface 0 ma tri-state balanced current loop -position detachable screw-terminal mounted on the rack s back board Transmission rate 0-, kbit/s Indicators Power, TD, RD,, DCD Isolation Complete galvanic insulation with opto-coupler (data) and transformer (supply) Isolation voltage 00 V Power supply External through PS-0 mounted in rack (RV-0) ±0 V DC ±0% Power consumption +0V 0 ma, -0V 0 ma Temperature range -0 C Humidity 0-% RH, non-condensing Dimension 00x00 mm Weight 0. kg Mounting In rack, takes one card-slot in RV-0 0-00

Switch settings The can through different switch settings be adapted to a variety of operating conditions. The switches are located on the circuit board and have the following functions: - - F/F Selection of signal activating transmitter (carrier) Selection of signal controlling CTS Fuse 00mA Fast F F Transmitter (carrier) activated by CTS controlled by Always active AUX Always high SRS DCD RFR DTR Factory settings DTR and AUX DTR and SRS DTR and RFR DTR and 0-00

Connections Line connection (-Position screw-terminal) Direction No. Description Direction ) Pin CCITT V. Description no. Circuit no. Transmitter R+ Transmitter R- Receiver T+ Receiver T- Shield Terminal connection (DCE) (RS--C/V./V., -Position D-sub, female) I 0 TD/Transmitted Data O 0 RD/Received Data I 0 /Request To Send O 0 CTS/Clear To Send O 0 DSR/Data Set Ready 0 SG/Signal Ground O 0 DCD/Data Carrier Detect I AUX/Auxiliary I 0 SRS/Secondary Request to Send I 0 0/ DTR/Data Terminal Ready I RFR/Ready For Receiving I=Input O=Output on Section of rack RV-0 with one mounted. Terminal connection to a -position D-sub (female) connector on. Line connection to a -position detachable screw-terminal, which is mounted on the male connector located at the rear of RV-0. 0 0-00

Line connection Twisted pairs ±0 ma Current Loop e.g. MA- Receiver R+ T+ Transmitter R- T- Transmitter T+ R+ Receiver Shield ) T- R- ) If shielded cable is used, connect the shield only at one end to avoid ground currents. Transmission range (interface ) Cable Transmission rate bit/s pf/m 0.mm 00 000m 00 000m 00 000m 00 000m 00 00m 00 000m 00 00m 0-00

Hints The has the same line interface as many of Westermo s systems MA-, MA-, MA-, MA-, MM-, MM-, LA-0, LD-0 and LD-0 are hence compatible. The RS- interface on the is configured as DCE (Data Communication Equipment). Most printers, PC s and terminals are set as DTE (Data Terminal Equipment). Some recommendation of cable configurations are given below. If any problems do occur on set up of the, the LED s will be helpful. - PWR: The unit has power. - RD: Data received on line interface. - TD: Data received on RS- interface. - DCD: Carrier indication, must be on for transmission. - : Indicates the carrier control status. A good way to check the MA- is to carry out a loop back test. Connect T+ to R+ and T- to R-. Connect the RS- port to a terminal. When keys are pressed on the terminal you should receive the echo on screen. The TD & RD lights will both flicker simultaneously as you press the keys. DTE DCE 0 0 0 0 0 0 0 0 -pol. PC 0 0 0-00

OWN COMMENTS 0-00

Block diagram RS--C/V. LINE ) DTR AUX X 0 +V & +V SRS RFR CTS DCD RD RD DCD R+ () R- () DSR TD SG +V 0V TD EN +V 0V T+ () T- () () Shield 0V X 0V POWER SUPPLY -...V +...V 0 00mA 00mA STAB +V 0V -V +V -V 0V -V Westermo Teleindustri AB have distributors in several countries, contact us for further information. Westermo Teleindustri AB S-0 0 Stora Sundby, Sweden Phone + 00 Fax + 0 E-mail: info@westermo.se Westermo Web site: www.westermo.se Westermo Data Communications Ltd Solent Business Centre Millbrook Road West Millbrook, Southampton SO 0HW Phone: +(0)0-0 Fax.:+(0)0 0 E-Mail: sales@westermo.co.uk Subsidiaries Westermo Data Communications GmbH Bruchsaler Straße, Waghäusel Tel.: +(0)-00-0 Fax.:+(0)-00- E-Mail: westermo.germany@t-online.de 0-00 0. TunaTryck AB, Eskilstuna, Sweden