INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-34 AC LD-34 DC

Similar documents
INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-42 AC MD-42 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-44 AC MD-44 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

User Guide. Westermo Teleindustri AB 2004 REV.A MDW Converter RS-232 RS-422/485.

INSTALLATIONSANVISNING INSTALLATION MANUAL MA-44/MA-44DC OMVANDLARE RS RS-422/485 CONVERTER RS RS-422/485. Balanced Transmission

MDW-45 Converter RS RS-422/485

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

User Guide Westermo Teleindustri AB TR-36. Tele and leased line modem for RV rack system.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOM-5A, 6A Asynchronous Fiber Optic Modems

Voice-Frequency Telegraph Modem HY101-SWT

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Trip amplifier, 1 channel

M9606. FSK Modem. 5C Communications Inc.

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

MODEL: DLS. Telemetering System

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

User Guide. Westermo Teleindustri AB 2006 IDW ISDN Terminaladapter.

dmx2pwm 9 channel dimmer setup manual

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Universal RS232/CMOS to RS422/RS485 Converter

1 What s in the shipping package?

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

NMEA Protocol Converter 2 Plus 3 Users Guide

1000BASE-TX to 1000BASE-SX/LX Media Converter

Miniature Synchronous Multipoint Modems

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

02/11/2015

02/11/2015

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

CAN-IO Custom IO remote module

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Interface converter G kbit/sec

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

ES86 Series Closed-loop Stepper Drive + Motor System (ES-D808 Drive+ Motor/Encoder)

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

Telemetrie-Messtechnik Schnorrenberg

DCPS Programmable DC Power Supply

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

USER MANUAL SATEL i-link I/O-converter Version 1.6

MODEL: DAST-20. Telemetering System

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

User Manual CTP4/8/16

Installation and Operating Manual

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

CP485-4 User s Manual

Two-phase Digital Stepper Motor Driver SD Low Vibration Low Noise Low Power. Characteristics. Performance Index. Product Codes:

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

This FAQ covers Single Direction use of current loop with transmitting devices.

PU202. Encoder Signal Generator and Level Converter. Operating Instructions. control motion interface

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

DSSIU-6-1U-V. Features VOM:

MODEL AT-10 ANALOG TRANSMITTER

This FAQ covers the common questions from technicians installing these converters.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

FOM-4SF Sync/Async Single Fiber Modem

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

KiloStream Data Sheet

M70LL Laser Distance Sensor

Preset counters, electronic

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

9600 bps, Dual Modem 170 Card Private Wire Only

Integrated servo motor

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Positioning drives DC motor, brushless Absolute multiturn position detection, Profibus-DP

FA Wireless SS Terminals

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

ELECTRONIC COMPONENTS LP4 32 USER MANUAL

Differential charge amplifier

TLS-A. Laurel Electronics, Inc. Triple output loop splitter. Connection details and general information

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

Differential Charge Amplifier

PRetrans Table of contents

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Artistic Licence. Rail-DMX-DALI. User Guide. Version 1-7. Rail-DMX-DALI User Guide

Encapsulated Power Supply

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

MODEL: MRP6. Final Control Elements

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Signamax Connectivity Systems Gigabit Ethernet Converter Series U S E R S

Transcription:

LD-34 AC LD-34 DC INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG Galvanic Isolation 6603-2001 CE Approved Westermo Teleindustri AB 1999 REV. A 4 kanalig switch - /V.24 4 channel switch - /V.24 4 Kanal Erweiterung -/V.24 www.westermo.se

Description LD-34 General The LD-34 is a 4 channel switch. The unit has one input channel that communicates with a selected output channel. A sixth channel called the Expansion channel is provided for onward connection to a modem or another unit. All channels are DCE connections., is available on all channels flow control. Channel selection is made by external signals on the Digital in connector or by raising the signal line. The front cover has 9 LED's to indicate the state of the various communications paths. As with all Westermo products the LD-34 provides a high level of galvanic isolation on the power supply side through transformers and through optocouplers on the inputs. Channel one and the digital inputs are isolated from channel 2-6. All operating parameters are set-up via DIP switches located under the lid on the top of the unit. The LD-34 is available in both AC (230V) and DC (12-36V) supply voltage. Digital In The Digital Inputs, A0,A1,EN, E1 and COM can be used to select the required output channel. The inputs have a voltage range of 10-30 VDC between A0, A1, EN, E1 and COM, COM is equivalent to 0V ( ). It is possible to reverse the polarity, which means COM = 10-30 VDC and the inputs are activated by 0V(-) being applied. The maximum input voltage on the inputs is 30 VDC at a maximum current of 5mA per input. Switching time when channel is less then 0.1 ms. All digital inputs are galvanic isolated via optocouplers. control Raising the signal on channels 2-5 activates this channel. Only one channel can be activated at a time. If two lines have active, the first gets priority. 8 6603-2001

Specifications LD-34 Transmission Asynchronous, full/half duplex or simplex Interface CCITT V.24 Inputs: 9-position D-sub outputs: 5-position screw block Isolation AC 3000V, DC 1500V Data rate 0-115,2 kbit/s Power supply 230 V AC +15/ 10% 48-62 Hz, 12-36V DC Fuse AC 100mA fast 5x20 mm. DC 1.6 A Indicators PWR, CH2, CH3, CH4, CH5,,,, Power consumption AC 30 ma, DC 1.5W Temperature range 5-50 C Humidity 0 95% RH, non-condensing Dimension 55x100x128 mm (WxHxD) Weight AC 0.5 kg, DC 0.3 kg Mounting On 35 mm DIN-rail LEDs for indication on LD-34 PWR Indicates that the unit has power CH2 Indicates that channel 2 is selected channel CH3 Indicates that channel 3 is selected channel CH4 Indicates that channel 4 is selected channel CH5 Indicates that channel 5 is selected channel Indicates that the unit is receiving data through channel 1 Indicates that the unit is sending data through channel 1 Indicates that the unit is receiving signal through channel 1 Indicates that the unit is sending signal through channel 1 6603-2001 9

Switch settings LD-34 Activation control ON S1 selection of channel 2-5 12345678 S1 ON 12345678 Selecting channel with Digital in (A0, A1) S2:1-6 (No function) Digital in A0 A1 EN E1 Ch 2 Ch 3 Ch 4 Ch 5 Ch 6 0 0 0 0 data data 1 0 0 0 data data 0 1 0 0 data data 1 1 0 0 data data 0 0 1 0 data 1 0 1 0 data 0 1 1 0 data 1 1 1 0 data X X 0 1 data data data data data X X 1 1 data X = donõt care Note: Unconnected input is Ô0Õ Factory settings S1 ON 12345678 S2 ON 123456 10 6603-2001

Connections LD-34 5 4 3 2 1 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Not used Terminal connection (Channel 1) Direction DCE Connection 9-pin D-Sub CCITT V.24 Description Signal Description NC 1 109 DCD/Data Carrier Detect O 2 104 /Received Data I 3 103 /Transmitted Data NC 4 108/2 DTR/Data Terminal Ready 5 102 SG/Signal Ground NC 6 107 DSR/Data Set Ready I 7 105 /Request To Send O 8 106 /Clear To Send NC 9 (Channel 2-6) Direction Channel 2 4 Pin No. I 5 10 15 /Transmitted Data O 4 9 14 /Received Data I 3 8 13 /Request To Send O 2 7 12 /Clear To Send 1 6 11 /Signal Ground I = input O = output NC = not connected Channel 5 Pin No. Channel 6 Pin No. Signal Description 6603-2001 11

Power connection LD-34 AC 3-position screw-terminal Power connection LD-34 DC 2-position screw-terminal Screw L N Power supply 230V AC power Earth Connection Power supply Voltage + + Voltage Example: How to connect SG Equipment DCE Equipment DTE SG Channel 2 Channel 3 SG Equipment DCE Equipment DTE SG Channel 4 Not used Channel 5 EXPANSION CPU Digital out Com Port A0 A1 EN E1 COM 12 6603-2001

OWN COMMENTS 6603-2001 13

Block diagram A0 CH 2 A1 EN CH 3 E1 CH 4 COM CH 5 PAL CH 1 CH 6 (exp.) Westermo Teleindustri AB have distributors in several countries, contact us for further information. Westermo Teleindustri AB S-640 40 Stora Sundby, Sweden Phone +46 16 612 00 Fax +46 16 611 80 E-mail: info@westermo.se Westermo Web site: www.westermo.se Westermo Data Communications Ltd Solent Business Centre Millbrook Road West Millbrook, Southampton SO15 0HW Phone: +44(0)1703-704 611 Fax.:+44(0)1703 702 682 E-Mail: sales@westermo.co.uk Subsidiaries Westermo Data Communications GmbH Bruchsaler Straße 18, 68753 Waghäusel Tel.: +49(0)7254-95400-0 Fax.:+49(0)7254-95400-9 E-Mail: westermo.germany@t-online.de 6603-2001 01.99 TunaTryck AB, Eskilstuna, Sweden