SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Similar documents
SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,

User s Guide Instructions for Installation and Operation

Operating Instructions

User s Guide Instructions for Installation and Operation

PRO Professional Radio Control Series Applications

ET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

VIPER Remote Control Systems

P700WLS IoProx Receiver

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

SV613 USB Interface Wireless Module SV613

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

COD GB / 1.0 RBAND/UMS - RBAND/CSM

Blue Point Engineering

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Modular Radio Telemetry System

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

UNIT A 8-30VDC 8-28VAC POWER V IN3 IN4 COM1/2 NO3 NO4 IN1 IN2 GND NO1 NO2 COM3/4 ANY 8-28VAC OR 8-30VDC POWER ADAPTER (SOLD SEPARATELY)

Modular Radio Telemetry System

Tower Light with Wireless Switch Control Box

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Operating Instructions

ELSEMA. GLR2701 Single Channel 27MHz Gigalink Receiver with Timer Controlled Relay Output

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

MODEL NC221 MOBILE TWO-TONE SEQUENTIAL DECODER INSTRUCTION MANUAL

Data Acquisition Modules/ Distributed IO Modules

Plus III Basics. Remote Flash Triggering. Connecting. Powering On/Off. Channels & Zones. Plus III FAQ

WLS-5500 Receiver (KSF & W26)

TOP VIEW. 6.75" (171.5mm) Network ID Selector. Input Voltage Selection Jumper 7.285" (185mm) Battery Positive Terminal SIDE VIEW. 6.12" (155.

DNT90MC DNT90MP. Low Cost 900 MHz FHSS Transceiver Modules with I/O

RADIOBAND V3 Programming & Installation Manual

2, 4, & 6 Button Application Tool

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

200, 201 Series Radio Telemetry Transmitters

FMR ELSEMA 2-Channel 151MHz Receiver - FMR15102

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

Ocean Controls KT-5221 Modbus IO Module

LoRa1276 Catalogue

Wireless Data Gathering Panel MODEL TS0825

DISCONTINUED. Modulation Type Number of RF Channels 15

LORA1276F30 Catalogue

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

MCR91501R 1-Channel, 915MHz Receiver with Frequency Hopping

DNT900. Low Cost 900 MHz FHSS Transceiver Module with I/O

+GF+ SIGNET Temperature Transmitter Instructions

P700-WLS ioprox Receiver

RM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01

The wireless alternative to expensive cabling...

RF1212 Catalog

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

DISCONTINUED. Modulation Type Number of RF Channels 15

Use of Voter Comparators to Improve Railroad Radio Communications

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

OEM KEYFOB TRANSMITTER DATA GUIDE

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

S-COR. FIGURE 1 Wiring Diagram NOTE: To reset S-COR to factory settings, press and! hold < and > buttons upon power up. INSTALLATION INSTRUCTIONS

Blue Point Engineering Inc.

NEW DIGITAL PUMP LOAD CONTROL

This Errata Sheet contains corrections or changes made after the publication of this manual.

LORA1278F30 Catalogue

DUAL BAND FM WIRELESS TRANSCEIVER RXQ1. Applications

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)

AM / FM RADIO TRANSMITTER KEYFOBS

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1-7.doc

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

Catalogue

User Manual. ProRF Encoder Transmitter & Receiver

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

Receiver 10-5 BER -100 dbm Transmitter RF Output Power 1 10 or 63 mw mw Antenna Impedance 50 Ω

RN-41-SM. Class 1 Bluetooth Socket Module. Features. Applications. Description. Block Diagram. rn-41sm-ds 9/9/2009

DM8010 tm. Hardware Reference Manual. Document Revision B3 May 16, 2018

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.

DRF4432D20 20dBm ISM RF Transceiver Module V1.21

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

LoRa1278 Wireless Transceiver Module

RF4432F27 Catalog

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

Wireless Rain and Wireless Rain/Freeze Sensor

Preliminary. RF Data Transmission Rates 38.4, 115.2, 200 and 500 kbps

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

DRF7020D13 13dBm ISM RF Transceiver Module

Embedded Radio Data Transceiver SV611

SMARTALPHA RF TRANSCEIVER

Radio Control Installation and Operating Instructions System 4

Quick Guide. FCC/IC: MHz CE: MHz

Installation Notes. SCR Single Channel

DNT2400. Low Cost 2.4 GHz FHSS Transceiver Module with I/O

HORNET Remote Control Systems

S ENSORLINK INSTALLATION MANUAL

The wireless alternative to expensive cabling...

Transcription:

Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The SF900C Series Remote Control/Switch Followers are a twoway system designed to provide a quick and cost effective solution for a variety of wireless switching applications. Each unit has multiple (4 or 8) inputs connected to a transmitter and 4/8 outputs connected to a receiver. Designed to work in pairs, the output relay at the receive end of one unit will follow the input at the transmit end of the paired unit. The inputs are opto-isolated and may be operated by an applied voltage that can be supplied by a power source from 5 to 24 Volts AC or DC through a switch contact, relay, sensor, PLC output, etc. Alternatively, instead of automatic switch following operation, the SF900C can operate as a 4/8-channel wireless relay using a SFT900C handheld remote control. The default mode is Momentary but with optional custom software, Latched and Toggle modes are available for special applications. When a button is pushed on the SFT900C, an RX LED and optional Beep will indicate that the proper relay was triggered after receiving a verified acknowledgment reply from the SF900C. In this mode, multiple transmitters can be used with one receiver as well as one transmitter can transmit to multiple receivers. These products utilize spread spectrum technology and are immune to interference and multipath fading. All inputs and outputs are independently isolated from each other and from the power supply ground. The antenna, however, is connected to the internal ground and, if AC powered, the antenna must be isolated from the power input ground. Features 4-Inputs/4 each-10a Relay Outputs or 8-Inputs/8 each 10A Relay Outputs Long Range: 1 to 5-miles Two-Way Operation Spread Spectrum Technology Isolated Inputs and Outputs 12-36 Volt DC or AC Operation Handheld Remotes Available Optional NEMA 4X Wall Mount Remote Available Antenna Included FCC Certified Made in USA Typical Applications Pump Control Motor Control Solenoid Control Lighting Control Access Control PLC Activation HVAC Control Ordering Information Model No. Product Description Channels Range Response Time SF900C4-B Switch Follower Transceiver 4 2-miles 180ms SF900C4-J Switch Follower Transceiver 4 ½-Mile 58ms SF900C8-B Switch Follower Transceiver 8 2-miles 180ms SF900C8-J Switch Follower Transceiver 8 ½-Mile 58ms SFT900Cn Handheld Transmitter, n-buttons n=1,2,3,4,6 or 8 www.appliedwireless.com Tel: (805) 383-9600 Fax (805) 383-9001

R S S D A T A Electrical Characteristics Sym Parameter Min Typ Max Unit Operating Voltage Range 10 12 36 Volts Operating Current, Receive Mode 45 56 ma Operating Current, Transmit Mode 212 225 ma Input Resistance 4.7K Ohms Signal Input Voltage 5 24 Volts AC or Output Relay Contact Ratings at 28VDC 10 Amps f Frequency Range 902 928 MHz Pout Output Power 100 mw Zout Antenna Input Impedance 50 Ohms Top Operating Temperature -20 +60 C Package Dimensions ANTENNA 1 3 5 7 P W REL AYS R I 1 3 5 7 APPLIED WIRELESS 2 4 6 8 2 4 6 8 LEARN 12-24V AC/DC FRONT VIEW 8 7 6 5 4 3 2 1 NO8 C8 NC8 NO7 C7 NC7 NO6 C6 NC6 NO5 C5 NC5 NO4 C4 NC4 NO3 C3 NC3 NO2 C2 NC2 NO1 C1 NC1 REAR VIEW RELATED PRODUCTS 600279-8 RPSMA ANTENNA BULKHEAD EXTENSION CABLE, 8.5 600279-L200E-72 RPSMA ANTENNA BULKHEAD EXTENSION CABLE, 6 FT OPTION 14 NEMA ENCLOSURE WITH CABLE GLANDS www.appliedwireless.com Tel: (805) 383-9600 Fax (805) 383-9001

LEARN PROCEDURE STANDARD TWO WAY APPLICATION: To pair two SF900C units, place both units in the learn mode by pushing their respective learn buttons. The learn lights will flash. Let s call one the Base unit and the other the Remote unit. The second push of the learn button on the Remote unit will trigger the learning process. Once completed, the learn lights will turn Off. The Remote unit will have learned and adopted the code and frequency of the Base unit. The Base unit is defined as the unit that has not adopted an alternate code. The distinction is important for the next example. RECEIVER/TRANSMITTER APPLICATION: To pair a SF900C to be used as a receiver with a SFT900C handheld transmitter, the case of the SFT900C will have to be removed to access the learn button. Remove the 4 screws from the back cover and remove it. Place both units in the learn mode by pushing their respective learn buttons. The learn lights will flash. Then press the learn button on the SFT900C handheld transmitter again and the pairing will take place. Replace the cover. The SFT900C Remote unit will have learned and adopted the code and frequency of the SFT900C Base unit. Other transmitters can be added one at a time by using the SF900C as the base unit by repeating the learn process. All of the transmitter will have learned and adopted the SF900C Base unit's code and frequency. More SF900C receivers can be added to the above system one at a time by using the same SF900C as the Base unit. However, the covers will have to be removed from the additional SF900C receivers and the ACK jumper will have to be moved to the NO ACK position to disable acknowledgements. When a signal is received from a transmitter, only one receiver, logically the Base unit, must reply with an acknowledgment to avoid collisions. CHANGING THE FREQUENCY: The least significant 5 bits of the address of the Base unit is used to determine the frequency of operation, one of 32 possible. Therefore, there is a 1 in 32 chance that any two units will be operating on the same frequency. The label on the units will have the 4 hex digit code as well as a 2 digit hex frequency. If two or more Base units are to be operating in the same area and they have the frequency, the Base units can be set to different frequencies. For those units that have a 6 position tri-state dip switch at S1, switches 1-5 set the frequency by moving the switches to the up or down position and switch 6 is an enable switch for the the alternate frequency selection if set to the down position. The center tri-state position for all of the switches disables the alternate frequency switch function.+ An alternate is a 4 position dip switch covering switch positions 2-5 and an enable jumper in place of switch 6 allowing for 16 possible frequencies. To enable the alternate frequency selection, Jumper J4 must be moved to the two pins closest to the EN position and each of the dip switches must be moved up or down. To disable the alternate frequency selection, the enable jumper must be moved to the two pins farthest from the the EN location and the dip switches must be moved to the center tri-state position. See the Frequency Select Switch Table. (1 is UP and 0 is DOWN.) NOTE: Whenever the frequency select switch, S1, is changed on the Base unit, the power has to be turned Off and back On again for the frequency change to take effect. Then, the Learn Procedure will have to be repeated for all of the Remote units associated with the Base unit that has a new frequency setting. FCC ID: QY4-618 www.appliedwireless.com Tel: (805) 383-9600 Fax (805) 383-9001

FREQUENCY SELECT SWITCH TABLE CHANNEL CHANNEL 6 Position Switch 4 Position Switch Decimal HEX BINARY, lsb first BINARY, lsb first 0 00 000000 0000 EN 1 01 100000 2 02 010000 1000 EN 3 03 110000 4 04 001000 0100 EN 5 05 101000 6 06 011000 1100 EN 7 07 111000 8 08 000100 0010 EN 9 09 100100 10 0A 010100 1010 EN 11 0B 110100 12 0C 001100 0110 EN 13 0D 101100 14 0E 011100 1110 EN 15 0F 111100 16 10 000010 0001 EN 17 11 100010 18 12 010010 1001 EN 19 13 110010 20 14 001010 0101 EN 21 15 101010 22 16 011010 1101 EN 23 17 111010 24 18 000110 0011 EN 25 19 100110 26 1A 010110 1011 EN 27 1B 110110 28 1C 001110 0111 EN 29 1D 101110 30 1E 011110 1111 EN 31 1F 111110 www.appliedwireless.com Tel: (805) 383-9600 Fax (805) 383-9001

Application Circuit Standard AC or DC Power Supply or Adapter as required. Wireless control. Up to 3 Miles line of sight. AC or DC Power Supply or Adapter as required. NO8 C8 N C8 N O7 C7 N C7 NO6 C6 N C6 N O5 C5 NC5 NO4 C4 N C4 N O3 C3 NC3 N O2 C2 NC2 NO1 C 1 N C1 12-24V 8 7 6 5 4 3 2 1 AC/DC N O8 C 8 NC8 NO7 C 7 NC7 N O6 C 6 NC6 NO5 C 5 N C5 N O4 C 4 NC4 NO3 C 3 N C3 NO2 C 2 N C2 N O1 C1 NC1 8 7 6 5 4 3 2 1 12-24V AC/DC These swtiches signals upto 36 volts) control these lights loads up to 10 amps). These swtiches signals upto 36 volts) control these lights. loads up to 10 amps). APPLIED WIRELESS SF900C Standard Application 4 of 8 circuits shown www.appliedwireless.com Tel: (805) 383-9600 Fax (805) 383-9001

www.appliedwireless.com Tel: (805) 383-9600 Fax (805) 383-9001