nalog and non-indicating type, PID control, set temperature by dial Features Improved control performance with built-in microcomputer dopting new uto-tuning PID control algorithm : Selectable ON/OFF, PID control (with the external slide SW) Easy to check controlling status with deviation indicators : Deviation LED(red, green), output LED(red) indicators Dial setting output OFF function broken display function Ordering information T S R P C Unit C Celsius F Fahrenheit Temperature range for each input type Temperature - to -8 to 22 Pt - - to 32 to 22 Pt - K 2 to 2 32 to 392 Pt J K 3 to 3 32 to 72 - J - to 32 to 72 Pt J K 6 to 6 32 to,2 - - K 8 to 8 32 to,72 - - K C to,2 32 to 2,92 - - K P DPtΩ J J(IC) K K(C) Item Size Control method Control output R Relay output S drive output -2VC /6Hz ON/OFF control & PID control combined S DIN W8 x H8mm(8pin plug type) M DIN W72 x H72mm L DIN W96 x H96mm T nalog setting type temperature : 8pin socket(pg-8, PS-8) is sold separately. H-67
Series TS TM TL llowable voltage range consumption -2VC /6Hz 9 to % of rated voltage Max. V Size DIN W8 H8mm DIN W72 H72mm DIN W96 H96mm method Setting type Deviation LED(red, green), Output LED(red) Dial setting Setting accuracy F.S. ±2%(room temperature 23 ± ) Input type Control Control output Specifications Functions Thermocouples ON/OFF Control PID Control Relay Di strength Vibration Relay life cycle Mechanical Electrical Insulation resistance Noise resistance Memory retention DPtΩ(allowable line resistance max. Ω per a wire) K(C), J(IC) Hysteresis: 2 fixed Control period: Relay output - 2 sec. / drive output - 2 sec. 2VDC±2V PV deviation indicatable, Error indicatable 2,VC /6Hz for min.(between input terminal and power terminal).7mm amplitude at frequency of to Hz(for min.) in each of X, Y, Z directions for 2 hours Min.,, operations(8, operations/hr) Min., operations(9 operations/hr) Min. MΩ(at VDC megger) ±2kV R-phase, S-phase the square wave noise(pulse width: us) by the noise simulator pprox. years(when using non-volatile semiconductor memory type) Environment mbient temperature - to, storage: -2 to 6 mbient humidity 3 to 8%RH, storage: -3 to 8%RH Insulation type Double insulation or reinforced insulation (mark:, di strength between the measuring input part and the power part: 2kV) pproval Weight 2 pprox. 2g(approx. 7g) pprox. 76g(approx. g) pprox. 237g(approx. 2g) : Out of room temperature range: elow model is F.S. ±%, Over model is F.S. ±3% 2: The weight is with packaging and the weight in parentheses is only weight. Environment resistance is rated at no freezing or condensation. Connections TS ( (PG-8, PS-8) is sold separately) + - 3 6 : DPtΩ(3-wire type) RELY OUT RESISTIVE LOD 2 7 8 ~ -2VC V /6Hz TM 2 3 6 7 8 9 Thermocouple: K(C), J(IC) 9 2 2 2 26 27 2 2 RELY OUT 22 RESISTIVE LOD 3 23 6 7 8 ~ -2VC V /6Hz + - H-68
Connections TL : DPtΩ(3-wire type) Thermocouple: K(C), J(IC) -2VC V /6Hz RELY OUT RESISTIVE LOD Dimensions TS 8.2 66.7 2 TM 72.7 6. 6. (: mm).8 TL 96.7 6. 6. Series cut-out Size C D TS Min. 6 Min. 6 +.6 +.6 TM Min. 9 Min. 9 68 +.7 68 +.7 TL Min. Min. 92 +.8 92 +.8 C D racket TS TM, TL 8.6 3 2 3.3.9 36 6 6 2 37.. 2 6 23.9 H-69
Terminal cover(sold separately) RM-COVER (72 72mm) 7 RL-COVER (96 96mm) 9 (: mm) 68. 3 9. 3 Parts description 7 8 6 2 3. Deviation indicator: It shows deviation of present temperature(pv) based on set temperature(sv) by LED. Input deviation indicator [Deviation indicator: (green), / (red)] PV deviation temperature Deviation indicator PV deviation temperature Deviation indicator Input OPEN indicators flash (every. sec.) Less than or equal to ±2 indicator turns ON This is the same as Fahrenheit( ). When power is on, all indicators light for 2sec., then all indicators turn off and control operation starts. 2. Set temperature(sv) dial: Dial to change set temperature(sv). When changing set temperature, it is applied after 2 sec. for the stable input. 3. Input type: Indicates type of present value. Input type or input range each product is shown in the below table. Input Range No. Temperature range( ) Temperature range( ) to 32 to 22 2 to 2 32 to 392 K(C) to 32 to 72 6 to 6 32 to,2 Thermocouple 8 to 8 32 to,72 C to,2 32 to 2,92 2 to 2 32 to 392 J(IC) 3 to 3 32 to 72 to 32 to 72 - to -8 to 22 DPtΩ to 32 to 22 2 to 2 32 to 392 to 32 to 72 Set temperature within input range each.. Temperature : Indicates temperature (, ) of set temperature(sv) and present value(pv).. Temperature range: Indicates temperature range of set temperature(sv). 6. Control output indicator indicator: Turns ON when control output(relay output/ drive output). 7. Control mode selector switch: Select PID control or ON/OFF control using switch. 8. Terminal: Terminals for external connections. For detail, refer to Connections. H-7 Exceed max. input value indicator flashes (every. sec.) More than -2 to less than or equal to - indicators turn ON More than indicator turns ON More than - indicator turns ON More than 2 to less than or equal to indicators turn ON Less than min. input value indicator flashes (every. sec.)
Product mounting TS(8 8mm) Series Series Mount the product on the, fasten bracket by pushing with tools as shown above. Functions drive output drive output 2VDC module INPUT LOD Load Temperature ON/OFF control Reverse operation ON/OFF control function is for controlling temperature by comparing present (Heating) temperature(pv) to setting temperature(sv). ON/OFF control is fixed on reverse operation(heating). Output turns on to power to heater when present temperature(pv) falls lower than setting temperature(sv) and the output turns off to turn off heater Hysteresis when present temperature(pv) is higher then setting temperature(sv). Temperature Hysteresis is fixed 2 during ON/OFF control. SV PID control PID constants are suggested and implemented based on self tuning from power until reaching set temperature(sv), then self tuning is over after reaching set temperature(sv). When power, in case that set temperature(sv) dial points at OFF or self tuning can not be started because present temperature(pv) is higher than set temperature(sv) or hunting occurs during self tuning, output control is switched to proportion band because that is considered to error. t that time, proportion band is fixed at. Control cycle of PID control and proportion control is 2 sec. in relay output model and 2 sec. in drive output model. STOP Control output could stop without power off by setting the front setting volume to below min. setting range. If control output stops by STOP function, Green indicator in deviation indicator( ) will flash every sec. Error Error mark will flash(every sec.) in PV indicator when error occurs during the control operation. It will operate normally, if input is connected or returned to normal range. No Description Control output indicators flash If input line is broken or is not connected. 2 indicator flashes If measured input is higher than temperature range. 3 indicator flashes If measured input is lower than temperature range. H-7