celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

Similar documents
celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

celduc r e l a i s Proud to serve you MOSFET BASED DC SOLID STATE RELAY SCM VDC 600VDC 40ADC Page 1/5 GB

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC. 4-20mADC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Control Input. Status Ouputs. 0 to 24VDC 1A AC/DC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

celduc r e l a i s Proud to serve you celduc MOSFET BASED DC SOLID STATE RELAY SCM VDC 200VDC 100ADC Page 1/5 GB

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2

MOSFET BASED DC SOLID-STATE RELAY (With built-in transient voltage suppressor) In & case / Out Insulation

PRELIMINARY DATA MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig.

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

RN Thyristor Controllers

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

Semiconductor contactors, Solid-state relays

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

QUINT-PS-24DC/24DC/10

Type CP-S, CP-C & CP-A Switch mode

Semiconductor contactors, Solid-state relays

Solid State Relays 3-Phase with Integrated Heatsink Types 2 & 3 Pole

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Switching power supplies CP range, Linear power supplies CP-L range. Content

CI-tronic Soft start motor controller

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Output Voltage* (nom.)(adjustable)

Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection

celduc r e l a i s Proud to serve you XKLD31006 DOCUMENT PRELIMINAIRE RELAIS STATIQUE A MOSFET POUR COURANT CONTINU 10-30VDC 40V (60V crête) 10ADC

CP-T range Product group picture

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Solid-state Contactor Specifications

1-Phase Integrated Heatsink Zero Cross or Instant On Switching

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Solid State Relays Zero Switching Types Solid State Contactor

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

CP-T range Benefits and advantages

To be automatically connected to the nearest North American Technical Sales Office:

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

References 1 for asynchronous motors 1

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

CP-E range Benefits and advantages

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

QUINT-PS/ 3AC/24DC/10

Zelio Control Measurement Relays

ACST310-8B. Overvoltage protected AC switch. Description. Features. Applications. Benefits

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

MINI-PS AC/24DC/1.3

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

LC35/2-DA-iC. 35 W Dimmable two channel intelligent Colour LED driver. 35 W V 0 / Hz. Functional Description. Mains Characteristics

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

Switching Power Supply Type SPP1 60W Enclosed type

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

TN1610H-6T. High temperature 16 A SCRs. Description. Features. Applications

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Soft starters with internal by-pass

SOLID STATE RELAY RATINGS

QUINT-PS AC/24DC/40

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

No-wear isolation of potentials in terminal block design

Industrial, 2-Pole ZS Type RA2A

Power supply CP-T 48/20.0 Primary switch mode power supply

ST300S SERIES 300A. Features. Typical Applications. Major Ratings and Characteristics. Bulletin I25158 rev. B 01/94. case style TO-209AE (TO-118)

Transcription:

Power Solid State Relay With Analog Control, pitch.5mm compact size and DIN rail mounting. Ready to use SinglePhase Relay: Phase angle controller Transfer characterisic :Angle open loop Operating voltage :160 to 450 Operating Current :0.1 to 40A page 1 /5 GB SIM465000 Phase angle controller Output : 160450AC 40A(*) Input : Analog 010 Wide variety of applications. Main frequency range : 40 to 70 Hz with self adaptation Analog control : oltage 010 Green LED visualization on the input Relay without trimmer (factory setting) Isolated internal power supply (taken from the mains) Built in protection : RC and DR Mounting and dismounting on DIN rail without any tool or directly mountable on panel with screws. (*) see conditions, thermal curve page 4. Designed in conformity with EN6094743 (IEC94743) and EN60950 SSR Proud to serve you All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. celduc

page /5 GB Control characteristics (at 5 C) Operating control voltage Maximum input voltage Input resistor Input LED Rise and fall time Input immunity Input immunity Paramètre / Parameter Conditions Symbol Typ. Unit Uc 0 to 10 Uc max ± 30 Rc kω see fig. IEC 100044 (burst) IEC 100045(schocks) time green 6 k K Output characteristics (at 5 C) Parameter Load voltage Operating range Peak voltage Mains frequency range Clamping voltage internal power supply current counsomption (from mains) AC51 nominal current : permanent AC53 nominal current Non repetitive overload current On state voltage drop (typical value) Dynamic resistance (typical value) Output Power dissipation (typical value for full conduction) Thermal resistance between junction to air Off state leakage current Minimum load current Rise and fall time Delay time Power up initialisation time Off state dv/dt Maximum non repetitive di/dt It (<10) Conducted immunity level Conducted immunity level Short circuit protection Conditions ( see Fig. 4 page 4 ) tp=10 (Fig. 3) @ 5 C @50Hz see fig. @50Hz see fig. IEC 100044 (burst) IEC 100045(schocks) FERRAZ Symbol Ue Ueminmax Up fm Uclamp Ie Ie AC51 Ie AC53 Itsm t rt Pd Rthj/a Ilk Iemin tau td max t init. dv/dt di/dt I t Typ. 400 160450 10 4070 8 (@1mA) 6 40 1 550 0,9 8 0,81xIe+0,08xIe Unit r r Hz ma r A r A r A mω W K/W ma ma /µs A/µs A s 3,3 (,5) <5 100 15 160 500 50 1500 4k criterion B 4k criterion B grc 5A/3A/50A/63A 14x51 General characteristics (at 5 C) Input to output insulation voltage Output to status insulation voltage Output to case insulation voltage Insulation resistance Rated impulse voltage Protection level / IEC 59 Pollution degree ibration resistance 10 55 Hz according to CEI68 : Shocks resistance according to CEI68 ( on DIN rail / with screws) Ambient temperature (with no icing or condensation) Storage temperature (with no icing or condensation) Ambient humidity Weight Conformity Ri mp double amplitude HR 500 100 (@500DC) IP (not tested) 30/50 /+70 40/+100 40 to 85 70 EN6094743 (IEC6094743) RMS RMS RMS MΩ g C C g 5, Rue Ampère BP30004 490 SORBIERS FRANCE Email : celducrelais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 1 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19

page 3 /5 GB Transfer characteristics (at 5 C) Paramètre / Parameter Operating analog voltage Minimum release voltage Uload/Ue (@ Ue typ.) Tranfer accuracy Transfer type Conditions Us @ Uc=10 Symbol Min Nom 010 0,1 >98 angle linear (see Fig. 1 ) Max Unit Other possibilities with SIL4 series :(consult us) With trimmer for minimum step level setting: With trimmer for fall and rise time setting: Type of soft fall and rise time :linear or exponential Transfer characteristic: angle, RMS, power Analog input :0 5, 4 ma,... Mains frequency range Mains voltage range Operating current 5, Rue Ampère BP30004 490 SORBIERS FRANCE Email : celducrelais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 1 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19

page 4 /5 GB Thermal specifications. The curve "1" gives the limits of the product. The temperature reached are acceptable for the components. These values are in compliance with most of SSRs manufacturers. In a cabinet with a minimum of ventilation or a non permanent current, these values are correct. The curve "" gives the limits of the product according to EN6094743 with a maximum rise temperature of 50 C (@40 C) for a permanent working and in air calm ( test during 8 hours). For a non permanent current, you can calcule the average power = Pd x duty cycle and check the rise temperature : ΔTj = Pd x Rthj/a (Pd and Rthj/a are given page )). The junction temperature must not exceed 15 C at the maximum ambient temperature. The maximum current is limited to the size of the thyristors = 50A. I (A) 45 40 35 30 5 15 10 5 0 0 5 10155303540455055606570758085 1 The thermal constant (Cth) of the product is 7 minutes. That means the rise temperature is only 63 of the stabilized temperature after a running time of 7 minutes. Tambient ( C) fig. 4 Overload current. 1 No repetitive Itsm is given without voltage reapplied. This curve is used for the determination of the protection. Repetitive Itsm is given for inrush current with initial Tj = 70 C. In normal working, this curve musn't be exceed. Be carefull, the repetition of the surge current decrease the lifetime SSR's. fig 3 Mounting and dismounting on DIN rail without any tool. Panel Mounting Warning! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable isolation in the event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration...). 5, Rue Ampère BP30004 490 SORBIERS FRANCE Email : celducrelais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 1 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19

page 5 /5 GB Connections. For the output terminals, the wire cross sections must be adapted to the load current and to the overcurrent protection device characteristics. The relay rated voltage must be adapted to the mains rated voltage. celpac use screw clamp connections. Mounting Only in vertical position: The user should protect heat sensitive materials as well as persons against any contacts with the heatsink. For non vertical mounting, the load current must be 50 lower than the rated one. For a good cooling, the SSR needs an air convection. Less convection air produces an abnormal heating. Keep a distance between the upper SSR and the lower SSR. In case of no space between two SSR (zero space between two SSRs), please reduce the load current. For further details refer to below : Derating current with no space between SSRs AC51 nominal currents are given with a space of,5mm between each SSR, for a permanent current during a minimum time of 8 hours in air calm according to IEC6094743. In case of non permanent currents or in case of SSRs are mounted with no space, you must check the heatsink temperature never exceed 90 C. When the SSRs are mounted side to side ( no space between each relay) a derating current of 5 must be take into account. A forced cooling ( fan inside the cabinet) improves significantly the thermal performances. Typical application : LOADS SILD product is designed mainly for AC51 résistive load. AC53 motor current are also given. For other loads, check the inrush current at turn ON and possible overvoltages at turn OFF or consult us : * AC55b : Incandescent lamps : Inrush current is generally 10 times In during few 10. So limit the nominal current at about 15A. * AC55a : Electric discharge lamp : These loads often have overcurrent at turn ON and overvoltage at turn OFF, so we advise to use 400AC SSR on 30AC mains. * AC56a : Transformers loads : ery high inrush current up to 100 times In. We advise to use random SSR. Protection : wires (mm ) control 1 x(0,75>,5) L = 6mm Power 1x(1,5>16) 1 x(1,5>10) L = 10mm To protect the SSR against a shortcircuit of the load, use a fuse with a I t value = 1/ I t value specified page. A test has been made with FERRAZ fuse ( see page ). It is possible to protect SSR by MCB ( miniature circuit breaker). In this case, see application note ( SSR protection) and use a SSR with high I t value (5000A s minimum). EMC : Immunity : We give in our datasheets, the immunity level of our SSRs according to the main standards for this type of products : EN6100044 &5. You can see the high immunity level in comparison with the products on the market. Emission: SSRs are complex devices which must be interconnected with other equipment (loads, cables,etc.) to form a system. Because the other equipment or the interconnections may not be under the control of celduc, it shall be the responsibility of the system integrator to ensure that syste containing SSRs comply with the requirements of any rules and regulations applicable at the system level.. Consult celduc laboratory which can make some tests in your application. L L torques 0,4N.m (0,6N.m max) 1,N.m (1,8N.m max) screwdriver screwdrive 3,5x0,5mm Pozidriv/ 0,8x5,5 (1x6) 5, Rue Ampère BP30004 490 SORBIERS FRANCE Email : celducrelais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 1 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19