HVDC High Voltage Direct Current

Similar documents
East-South HVDC Interconnector II, India : in commercial operation since 2003

DESIGN CONSIDERATIONS OF ULTRA HIGH VOLTAGE DC SYSTEM

Design and Simulation of Passive Filter

Bipole III Transmission Project

High Voltage Direct Current Transmission Proven Technology for Power Exchange

High Voltage DC Transmission 2

Introduction to HVDC Transmission. High Voltage Direct Current (HVDC) Transmission

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

SRI VIDYA COLLEGE OF ENGG AND TECH

Voltage Source Converter Modelling

Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation

Recent trends in High Voltage Direct Current (HVDC)Transmission Systems Abstract

High Voltage DC Transmission Prof. Dr. S. N. Singh Department of Electrical Engineering Indian Institute of Technology Kanpur

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

SYSTEM STUDIES for HVDC

Insulation Co-ordination For HVDC Station

Digital Fault Recorder Deployment at HVDC Converter Stations

Curso de Transmissão em Corrente Continua Rio de Janeiro, de Junho, 2007

A Review Paper on Technical Data of Present HVDC Links in India

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING UNIT I

ATC s Mackinac Back to Back. Summary

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Industrial Electronics

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES

High Voltage DC Transmission Prof. Dr. S. N. Singh Department of Electrical Engineering Indian Institute of Technology, Kanpur

Study of Technical Data of Present HVDC Links in INDIA and Techniques Used For System Stability in HVDC Transmission Line

USE OF HVDC MULTI TERMINAL OPTIONS FOR FUTURE UPGRADE OF THE NATIONAL GRID

VSC Transmission. Presentation Overview. CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April LCC HVDC Transmission

This is a preview - click here to buy the full publication. Performance of high-voltage direct current (HVDC) systems with linecommutated

A cost effective hybrid HVDC transmission system with high performance in DC line fault handling

Principles for Controlling Harmonics

B4-203 NELSON RIVER POLE 2 MERCURY ARC VALVE REPLACEMENT

Topics in JNTU Syllabus Modules and Sub Modules Lecture. Basic characteristics L21 T1-Ch4, T2-Ch14 Characteristics. Modification of the control

HVDC. for beginners and beyond

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

COOPERATIVE PATENT CLASSIFICATION

ATC s Mackinac Back-to-Back HVDC Project: Planning and Operation Considerations for Michigan s Eastern Upper and Northern Lower Peninsulas

Application Of Artificial Neural Network In Fault Detection Of Hvdc Converter

Reactive Power and AC Voltage Control of LCC HVDC System with Digitally Tunable Controllable Capacitors

Principles of HVDC Transmission

High-Voltage Direct Current Technology - Part 2

HVDC Solutions for Integration of the Renewable Energy Resources

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström

Power Factor. Power Factor Correction.

IJEETC. InternationalJournalof. ElectricalandElectronicEngineering& Telecommunications.

Simulation of H bridge Inverter used for Induction Melting Furnace

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Power Upgrading of Transmission Line by Injecting DC Power in to AC Line with the help of ZIG-ZAG Transformer

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Case Study 1. Power System Planning and Design: Power Plant, Transmission Lines, and Substations

Open-Delta Systems Affect Variable Frequency Drives

PAPER-II (Subjective)

2013 Applied Power Electronics Conference (APEC) Page 1 of 8

Electromagnetic Transient Simulation for Study on Commutation Failures in HVDC Systems

Magnetization System of Magnetically Controlled Shunt Reactors

CERN - ST Division THE NEW 150 MVAR, 18 KV STATIC VAR COMPENSATOR FOR SPS: BACKGROUND, DESIGN AND COMMISSIONING

LECTURE NOTES FUNDAMENTALS OF HVDC AND FACTS DEVICES. IV B.Tech II Sem (JNTU R15) Prepared by. Ms. B. Manogna Assistant Professor

New HVDC Interaction between AC networks and HVDC Shunt Reactors on Jeju Converter Stations

EE6010 HVDC TRANSMISSION TWO MARK QUESTIONS AND ANSWERS

Should we transform our lines to HVDC?

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

HVDC Transmission Using Artificial Neural Networks Based Constant Current and Extension Angle Control

POWER QUALITY ENHANCEMENT BY DC LINK SUPPLIED INDUSTRIAL SYSTEM

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Power Engineering II. High Voltage Testing

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Speed Control Of Transformer Cooler Control By Using PWM

ELECTRONIC CONTROL OF A.C. MOTORS

Understanding the Design and Control of VSC-Based HVDC System with Shunt Passive Filters

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

shunt (parallel series

Fundamental Concepts of Dynamic Reactive Compensation. Outline

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

POWER- SWITCHING CONVERTERS Medium and High Power

Design and R&D for an ECRH Power Supply and Power Modulation System on JET

Power Flow Control And Total Harmonic Distortion Reduction In HVDC Link Using PI And ANN Controllers

Introduction to HVDC VSC HVDC

TECHNICAL SPECIFICATION

Voltage and current regulation circuits operating according to the non-switched (linear) principle are classified in subclass G05F

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

IGBT Induction Heater Profiles

Voltage and Current Waveforms Enhancement using Harmonic Filters

Single Line Diagram of Substations

Grounding System Theory and Practice

Dietrich Bonmann, ABB Monselice Transformer Days, May 5, 2010 Optimized AC transmission solutions with phase-shifting transformers and shunt reactors

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Design of an 80kV, 40A Resonant SMPS for Pulsed Power Applications

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

6 HVdc Converter Stations and Electrodes

Part Five. High-Power ac Drives

Modelling of the back-to-back converter between Uruguay and Brazil in A.T.P.

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Pre location: Impulse-Current-Method (ICE)

ELEMENTS OF FACTS CONTROLLERS

Design of Magnetically Controlled Shunt Reactors

Transcription:

HVDC High Voltage Direct Current

Typical HVDC Station

BACK TO BACK CONVERTER STATION MONO POLAR WITH GROUND RETURN PA Back to Back Converters indicates that the Rectifiers & Inverters are located in the Same Station. Back-to-Back Converters are mainly used for Power transmission between adjacent AC grids which can not be synchronized. Mono Polar With Ground Return Path: For very long distance & in particular for very long sea cable transmission, return path with ground / sea electrodes will be feasible solution. In many cases, existing infrastructure prevent use of electrodes. In such cases, metallic return path is used in spite of

BIPOLE WITH GROUND RETURN PAT BIPOLE WITH METALLIC RETURN PATH This is a commonly used configuration for a bipolar transmission system. The solution provides a high degree of flexibility with respect to operation wit reduced capacity during contingencies or maintenance. Upon a single pole fault, the current of sound pole will be taken over by the ground return path & faulty pole will be isolated

Simplified Single line diagram Bipolar converter station

Converter transformer Smoothing reactor D.C Side A.C Side A.C Filter 12-pulse Rectifier or converter Rihand-Delhi 1500 MW, Bipole HVDC Transmission System D.C Filter

Satellite Image (RihandDelhi HVDC) A.C Side(A.C Filter, Converter Transformer Thyristor Valve Hall (12 Pulse Converter, Valve Cooling equipment) D.C Side ( Smoothing Reactor, D.C Filter, Surge arrestor, D.C Line)

A.C switch

A.C Filter - 3 x 230 MVAR (11/33,3/36,5/27) The 12-pulse HVDC converter produces current harmonics (11th, 13th, 23rd, 25th, 35th, 37th etc.) on the AC side. These harmonics are prevented from entering into the connected AC network by AC filters, i.e. resonant circuits comprising capacitors, inductances (reactors) and resistors. The filters also produce a part of the reactive power consumed by the converter.

Conventional HVDC converters always have a demand for reactive power. At normal operation, a converter consumes reactive power in an amount that corresponds to approximately 50 % of the transmitted active power. The simplest way to generate reactive power is in shunt connected capacitor banks. Some of these capacitor banks can then be combined with reactors and resistors to form filters providing low impedance paths for the harmonics in order to limit them from entering into the connected AC network A series resonance filter branch will give a very low impedance and thereby efficient filtering in a narrow frequency band around the tuning frequency. Such branches are therefore normally used for the largest harmonics, i.e. the 11th and 13th

Filter bank 1 (11th order harmonics & 33rd Harmonics) Filter bank 2 (3rd order harmonics & 36th Harmonics) Filter bank 3 (5th order harmonics & 27th Harmonics)

Converter Transformer 305 MVA( 1 Phase,3 Winding)

Rihand Delhi HVDC uses singlephase-three-winding Transformer. Converter transformers connect the AC network to the thyristor valve bridge, and adjust the voltage on the valve side to a suitable level based on the DC voltage used for the transmission. Converter Transformer Serves for following purpose: Supply of AC voltages in two separate circuits with a relative phase shift of 30 electrical degrees for reduction of low order harmonics, especially the 5th and 7th harmonics. Act as a galvanic barrier between the AC and DC systems to prevent the DC potential to enter the AC system. Voltage transformation between the AC supply and the HVDC system.

Thyristor Valve - 12 Pulse Converter ( 6.5Kv, 1568 Amp, Water cooled, Suspended type)

Converter Transformer Sing Doubl Quadrupl e Valve le e Valv Valve e conversion from AC into The thyristor valve make the central component of any HVDC converter Dc & thus are the The basic circuit consists of two 6-Pulse bridge converter, but in order to eliminate the largest harmonics, two such bridges are connected in series forming a 12-pulse converter. The thyristor valves are normally located in a valve building and arranged as three structures (quadruple valves) suspended from the ceiling of the valve hall,

Thyristors are used as switches & thus the valve becomes controllable. The Thyristor valve will have firing circuit in the same arrangement. For Seismic requirement reasons, the entire thyristor valve are suspended from the ceiling of the valve hall.

The Thyristors are triggered by electrical gate pulses generated in a small electronic thyristor control unit (TCU) located near each thyristor. These units receive triggering impulses 50 or 60 times per second from the HVDC control system. In Rihand-Delhi HVDC, Light Triggered Thyristor (LTT) are used to trigger the thyristor, by injecting the photons into the gate of thyristor instead of electrons. With LTT Technology, the gating light pulse is transmitted via fiber optic cable through the thyristor housing directly to thyristor. Thus no elaborate electronic circuits are required for firing. The required

DC switchyard The DC switchyard contains all the external equipment needed for an HVDC transmission: Voltage dividers Current measuring devices Smoothing Reactors DC Filters Transmissions with cables(underground or underwater) does not require any DC filter. Transmissions with OH typically require DC filters to prevent the harmonics generated by the converter to be transported along the DC line. A harmonic filter for 12th and a high pass is usually enough.

Smoothing Reactor Air Insulated dry type reactor Oil insulated reactor in a tank - 180 mh 360 mh The dc reactor contributes to the smoothing of the dc current and provides harmonic voltage reduction in the dc line. The dc reactor also contributes to the limitation of the crest current during a short-circuit fault on the dc line. It should be noted that the inductance of the converter

Smoothing Reactor ( Air Insulated dry type reactor) Advantage of the Dry-Type reactor is that maintaining spare parts is not very expensive because the usually consist of several partial coils. However for very large inductances it is possible to have more than one unit & it could be a problem if much space is not available For Air Insulated Dry-Type Smoothening Reactor, a wall brushing is needed to connect with the valves. Purpose of Smoothing reactor Prevention of Intermittent Currents Limitation of DC Fault Currents Prevention of resonance in the DC Circuit. Reducing harmonic currents including limitation of

Smoothing Reactor ( Oil insulated reactor in a tank ) In High Seismic Regions, Setting them on the Post insulators or on an insulating platform is a possible solution. Oil insulated smoothing reactor are then the preferred solution. One Bushing of the Oil insulated Smoothing reactor penetrates usually into valve hall, while other bushing is normally in a vertical position

D.C Filter 2 X (12, HP 24)

The HVDC converter also gives rise to voltage harmonics on the DC side (12th, 24th, 36th etc.). A large inductance (smoothing reactor) is always installed on the DC side to reduce the ripple in the direct current. In addition, a DC filter is also normally needed to reduce the level of harmonic currents in the DC overhead line. The harmonics may otherwise cause interference to telephone circuits in the vicinity of

For overhead line transmissions, it is normally necessary to install additional filter circuits between the pole bus (outside the smoothing reactor) and the neutral bus. Capacitors or filter circuits may also have to be installed between the neutral bus and ground. The filter types used on the d.c. side are essentially the same as those used on the a.c. side, i.e. series resonance filters and high pass filters. The largest item of a DC filter, the capacitor, is often suspended, especially in seismic areas. The principle of the active DC filter is to inject a current generated by a power amplifier into the DC circuit cancelling the DC side harmonics coming from the HVDC converter.

Why HVDC transmission?