PM5000 Series. PowerLogic PM5100, PM5300 and PM5500 series

Similar documents
PowerLogic PM5000 series

PowerLogic PM5000 series

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Power Meter Series PM3200 Functions and characteristics

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

Power Meter Series PM9

Conzerv EM6400NG series

Side view View from below Rear view

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

MT 560/UMT TRANSDUCER & ANALYZER

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Energy Management Energy Analyzer Type EM210 MID

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

ULTRA RAPID POWER QUALITY ANALYZER

Energy Management Three-phase energy meter with output modules Type EM4-DIN

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Energy Management Energy Meter Type EM110

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

UMG 509-PRO. Multifunction power analyser with RCM

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM340

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

UMG 103-CBM. Universal measurement device for DIN rails

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

PQube 3 Specifications

Smart Demand Controller

Energy Management Energy Meter GM3D

Energy Management Energy Analyzer Type EM111

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Energy Management Energy Meter Type EM110

PQM3000R Class A network analyzer according to EN for power quality monitoring

Energy Management Energy Analyzer Type EM210

Energy Management Energy Meter Type EM21 72R Retro-Fit

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

PEM353. Universal measuring device

Energy Measurement & Management

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Centrale de mesure Power Meter PM500 Merlin Gerin

Energy Management Energy Analyzer Type EM112

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

Data Sheet. RISH Master Record %THD

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Introduction DIN rail mounted electricity meters

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

AMIK 200 / 201 Technical Data Sheet

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Advantages There are many diverse advantages of a portable analyzer for the user. The most important is information.

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

EM-72 Electricity Meters for Current Transformers

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

NETWORK ANALYZERS Analyzers

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

ZHUHAI PILOT TECHNOLOGY CO., LTD.

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Operating Guide October 2006

Measuring centers MC7x0 series Multifunction Meter MC740

Measuring transducers

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Monitoring Electric Network Via Internet

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Automation for a Changing World. Delta Power Meter DPM Series VARITEL

Transienten. Datenspeicher

PQube 3 Specifications

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Technical Data Sheet. x1000. kwh R Y B

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

M.8. Portable power analyzers and accessories CONTENTS. Page. Introduction 3 AR.5 AR5L. Power analyzers 4. Applications 4 Harmonics.

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

PLA 33. Power line analyzer. User and service manual. version 2.4

ENERIUM. A powerful solution for energy management and the environment

E650 Series 3. Electricity Meters IEC/MID Industrial and Commercial ZMD402AT/CT, ZFD402AT/CT. Technical Data

DOBLE F6150e TECHNICAL SPECIFICATIONS

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

RE17LLBM asymmetrical flashing relay s V AC - solid state output

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

Delta Power Meter DPM Series

Transcription:

Functions and characteristics PowerLogic PM5100, PM5300 and PM5500 series PB111776 The PowerLogic applications. It provides the measurement capailities needed to allocate energy usage, perform tenant metering and su-illing, pin-point energy savings, optimise equipment electrical network. In a single 96 x 96 mm unit, with a graphical display, all three phases, neutral and ground can e monitored simultaneously. The right, anti-glare display features large characters and powerful acklighting for easy reading even in extreme lighting conditions and viewing angles. Easy to understand menus, text in 8 selectale languages, icons and graphics create a friendly environment to learn aout your electrical network. Applications PowerLogic meter PM5100 METSEPM5100 PM5110 METSEPM5110 PM5111 METSEPM5111 PM5310 METSEPM5310 PM5320 METSEPM5320 PM5330 METSEPM5330 PM5331 METSEPM5331 PM5340 METSEPM5340 PM5341 METSEPM5341 PM5560 METSEPM5560 PM5561 METSEPM5561 PM5563 METSEPM5563 PM5561 METSEPM5561 PM5563 METSEPM5563 Cost management: how and when your facility uses electricity. The PowerLogic PM5000 series meters are ideal for: condominium association, homeowners association, or other multi-tenant approved meters for illing applications across Europe. Cost allocation: indoor and outdoor lighting, refrigeration, etc), different parts of an industrial money y making changes to your operation, etter maintaining your equipment, Network management: Improving reliaility of the electrical network is key for success in any usiness. Monitoring values such as voltage levels, harmonic distortion and voltage unalance will help you to ensure proper operation and maintenance of your electrical network and equipment. PowerLogic PM5000 series meters are the perfect tool for: Basic Power Quality monitoring: power quality phenomena can cause undesirale effects such as heating in transformers, capacitors, motors, generators and misoperation of electronic equipment and protection devices. Min/ Max monitoring (with timestamp): understanding when electrical parameters, such as voltage, current and power demand, reach maximum and minimum values will give you the insight to correctly maintain your electrical network and assure equipment will not e damaged. Alarming: alarms help you to e aware of any anormal ehavior on the electrical network in the moment it happens. WAGES monitoring: take advantage of the input metering on PM5000 meters to integrate measurements from 3rd party devices such as water, air, gas, electricity or steam, meters. Main characteristics Easy to install without voltage transformers for installations compliant with category III. Easy to operate Intuitive navigation with self-guided, language selectale menus, six lines, four - customizale either for alarms or energy pulse outputs. The PM5300 provides two relay outputs (high performance Form A type) with monitored switches can e wired directly to the meter without external power supply. PM5500 series have 4 status inputs (digital) and 2 digital output (solid state) to use for WAGES monitoring, control and alarm annunciation. Accurate energy measurement for precise cost allocation: IEC 62053-22 (Active Energy) Class 0.5S Class 0.5S Class 0.2S IEC 62053-24 (Reactive Energy) Class 2 Class 2 Class 1 2014 71

PB111768 Direct metering of neutral current servers), measuring neutral current is essential to avoid overload and resulting outage. In addition, the PM5500 provides a calculated ground current value, not Power Quality analysis angles for voltage and current: Individual Harmonics magnitudes up to 15th magnitudes up to 31st magnitudes & angles up to 63rd PowerLogic PM5500 meter These types of power quality parameters help to identify the source of harmonics that can harm transformers, capacitors, generators, motors and electronic equipment. PB111770 Load management Peak demands with time stamping are provided. Predicted demand values can e used in comination with alarms for asic load shedding applications. Alarming with time stamping A different comination of set point driven alarms and digital alarms with 1s time stamping are availale in the PM5000 family: PB111768 PowerLogic PM5300 meter PowerLogic PM5100 meter MID legal metrology relevant to active electrical energy meters (see Annex MI-003 of Alarms can e visualized as Active (the ones that have picked up and did not drop out Alarms can e programmed and comined to trigger digital outputs and mechanical relays (PM5300). The PM5000 series keeps an alarm log with the active and historical alarms with date and time stamping. Load timer A load timer can e set to count load running hours ased on a minimum current High Performance and accuracy error in the class for real and reactive power and energy, frequency, current, voltage, power factor, voltage unalance, voltage and current harmonics (odds), voltage up current and safety. It makes compliant meters readings comparale - they will measure the same values when connected to the same load. In addition to illing applications, for facility managers responsile for energy cost Set point driven alarms 29 29 29 Unary 4 4 4 Digital 2 4 Boolean / Logic 10 5 72 2014

General Instantaneous rms values per phase, neutral and ground (PM5500) Frequency Real, reactive, and apparent power Total and per phase Signed, Four Quadrant True Power Factor Total and per phase Signed, Four Quadrant Total and per phase Signed, Four Quadrant Energy values* Accumulated Active, Reactive and Apparent Energy Demand values* Active power Reactive power Apparent power Peak demand with time stamping D/T for current and powers thermal methods Synchronisation of the measurement window to input, communication command or internal clock Other measurements* Operating timer Load timer Alarm counters and alarm logs Power quality measurements Individual harmonics (odds) 15th 31st 63rd Data recording Alarms with 1s timestamping* and duration (e.g. 2 parameters for 60 days at 15 minutes interval) Up to 14 selectale parameters duration (e.g. 6 parameters for 90 days at 15 minutes interval) Memory capacity 256 kb 1.1 MB Min/max log Maintenance, alarm and event logs Customisale data logs Inputs / Outputs / Mechanical Relays 2 (SI1, SI2) 4 (SI1, SI2, SI3, SI4) with WAGES support 1 (kwh only) Form A Relay outputs 2 Timestamp resolution in seconds 1 Whetting voltage Onoard wepages *Stored in non-volatile memory 2014 73

Electrical characteristics Type of measurement: True rms on three-phase 64 samples per cycle 128 samples per cycle Measurement accuracy Active Energy Input-voltage (up to 1.0 with voltage transformer) Reactive Energy Active Energy ±0.5% ±0.2% Reactive Energy ±2% ±1% Active Power Apparent Power Current, Phase ±0.15% Voltage, L-N ±0.1% Frequency ±0.05% MID Directive EN50470-1, EN50470-3 Impedance Annex B and Annex D (Optional model references) Class C 20 V L-N / 35 V L-L to 400 V L-N /690 V L-L asolute range 35 V L-L to 760 V L-L 20 V L-N / 20 V L-L to 400 V L-N /690 V L-L asolute range 20 V L-L to 828 V L-L F nom Input-current I nom 1 A or 5 A power power Measured Amps with over range and Withstand Impedance Starting current: 5mA Operating range: 50mA to 8.5A Starting current: 5m A Operating range: 50 ma to 10 A F nom Burden Operating range Burden Frequency Ride-through time Operating range maximum urden maximum urden Burden Ride-through time Outputs Relay Max output frequency 0.5 Hz maximum (1 second ON / 1 second OFF - minimum times) Switching current cycles, resistive 12.5 k cycles, resistive Isolation 2.5 kv rms outputs 1 2 2 Max load voltage 40 V DC 30 V AC / 60 V DC Max load current 20 ma 125 ma On Resistance 50 max 8 Meter constant Output Output from 1 to 9,999,999 pulses per kwh 50% duty cycle 25 Hz max. Leakage current 0.03 micro Amps 1 micro Amps Isolation 5 kv rms 2.5 kv rms Optical outputs Pulse width (LED) 200 ms Pulse frequency 50 Hz. max. Meter constant from 1 to 9,999,999 pulses per kwh 74 2014

Electrical characteristics (cont'd) Status Inputs Input Resistance Maximum Frequency 250 ms) 20 ms) Response Time 20 ms 10 ms Opto Isolation 5 kv rms 2.5 kv rms Whetting output 24 V DC/ 8mA max Input Burden 2mA @24V DC 2 ma @ 24 V AC/DC Mechanical characteristics Product weight 380 g 430 g 450 g Mounting position * Panel thickness Environmental characteristics Operating temperature IP52 front display, IP30 meter ody Vertical 6 mm maximum Meter -25 C to 70 C reduced performance) -25 C to +70 C Storage temp. -40 C to +85 C 5 to 95 % RH at 50 C (non-condensing) Polution degree 2 Altitude 2000 m CAT III / 3000 m CAT II 3000 m max. CAT III Flicker emissions IEC 61000-3-3 Electrostatic discharge IEC 61000-4-3 Immunity to fast transients Immunity to surge Immunity to voltage dips Radiated emissions 2014 75

Safety Europe culus as per UL61010-1 (3rd Edition) CAT III up to 400 V L-N / 690 V L-L As per IEC/UL 61010-1 Ed. 3 Communication II, Doule insulated for user accessile parts 1 Optional 2 (for daisy chain only, one IP address) Isolation Human machine interface Resolution 128 x 128 Backlight Keypad Energy pulse alarm indication Wavelength Maximum pulse rate 67 x 62.5 mm 4-utton 590 to 635 nm PE86288 Features and Options PM5100 PM5110 PM5310 PM5320 PM5330 PM5340 PM5560 PM5563 Installation Fast installation, panel mount with integrated display Fast installation, DIN rail mountale Accuracy CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.2S CI 0.2S Display Backlit LCD, multilingual, ar graphs, 6 lines, 4 concurrent values Power and energy metering 3-phase voltage, current, power, demand, energy, frequency, power factor 4 4 4 4 8 8 Power quality analysis THD, thd, TDD Harmonics, individual (odd) up to 15th 15th 31st 31st 31st 31st 63rd 63rd I/Os and relays I/Os 1DO 1DO 2DI/2DO 2DI/2DO 2DI/2DO 2DI/2DO 4DI/2DO 4DI/2DO Relays 0 0 0 0 2 2 0 0 Alarms and control Alarms 33 33 35 35 35 35 52 52 Set point response time, seconds 1 1 1 1 1 1 1 1 Single and multi-condition alarms Boolean alarm logic Communications Serial ports with modus protocol 1 1 1 1 1 Ethernet port with Modus TCP protocol 1 1 2** 2** onoard wepages MID ready compliance, EN50470-1/3, Annex B and Annex D PM5111 PM5331 PM5341 PM5561 Class C ** 2 Ethernet ports for daisy chain, one IP address. 76 2014

Dimensions and connection meter dimensions PB111279 PB111276 PM5500 PB111278 PB111277 PM5500 PM5000 meter parts A Menu selection uttons B C D Maintenance and alarm PM5500 meter parts E F RS-485 comms G H I J Ethernet ports K PM5100 / PM5300 meter parts E Relay output (PM5300 only) F G H I J Ethernet (PM5300 only) or RS-485) 2014 77