Product Information PI

Similar documents
Product Information PI

Product Information PI

Product Information PI

Product Information PI

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

Product Information PI

Rotating Anode X-Ray Tube Housing Assembly. General Data

Stationary Anode X-Ray Tube. General Data

Rotating Anode X-Ray Tube Housing Assembly. General Data

Rotating Anode X-ray Tube Assembly

Rotating Anode X-ray Tube

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

Industrial X-ray Tube KL

Technical Data TD. X-Ray FLAT PANEL IMAGER FDX3543RP FEATURING: Active Area: 35(H) 43(V)cm (14 17 ) Excellent Sensitivity & Resolution

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

Corsix R 32 Accu PRODUCT DATA

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

BCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

MG MW S-Band Magnetron

Digital Panoramic X- Ray unit. Product Data

MobileDaRt Evolution MX8 Version

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

YD1195/8913 YD1197/8937 RF Power Triodes

The AMK 15-2 is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies

BCA 9RK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Practix. Mobile Radiography. Constantly on the move, and yet never tired. Practix 160

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW

MILADY. Product Data. Page 1 of 8

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

MG7095 Tunable S-Band Magnetron

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

MG5223F S-Band Magnetron

X-ray Tube and Generator Basic principles and construction

ARU-01CF Portable X-Ray NSN:

MXRP-160C. Product Description. Product Specifications

MG6090 Tunable S-Band Magnetron

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0

M5028 Precision Tuned Magnetron

Distributed by. Ecotron Anyview Series. The Intelligent C-Arm System

MG5193 Tunable S-Band Magnetron

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

E2V Technologies MG6028 Fast Tuned Magnetron

Flasher, 30 mω Shunt, Pilot Lamp to GND or V Batt U2043B

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

CX1140 Hydrogen Thyratron

SAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS

Practix. Mobile Radiography. Changing its point of view comes naturally. Practix 300

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

THE PANTAK THERAPAX SXT 150

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

A-ISOMETER IR / IR

UNISONIC TECHNOLOGIES CO., LTD

MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier

Low Capacitance Transient Voltage Suppressors / ESD Protectors CM QG/D. Features

Flasher, 18-mΩ Shunt, Frequency Doubling Disabling U6433B

Emotron FDU 2.0 Variable Speed Drive

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

MOBILEART eco C504-E009G

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

For more information, please visit the product page. output. output current max (A)

XRC X-Ray Calibration System

X-ray Tube and Generator Basic principles and construction

CUSTOMER S ACCEPTANCE SPECIFICATIONS

VOF XX - XXX - X

Flasher IC with U643B

E2V Technologies MG5223F S-Band Magnetron

2017 Advanced Energy Industries, Inc. PEII SERIES LOW-FREQUENCY POWER SUPPLIES 5 TO 60 KW

World-Class Accuracy & Measurement Range (40 Conventional Models)

MULTIX PRO/TOP, VERTIX Solitaire, VERTIX PRO/TOP

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

AT5210 FEATURES DESCRIPTION APPLICATION. 150mA High PSRR LDO. AT X.X KE R Shipping: IAT R: Tape & Reel Circuit Type. Immense Advance Tech.

ISOMETER IR Headline. Version V004. Vorläufiges Datenblatt

AZ386 General Description. Features. Applications

AT432 Low Voltage Adjustable Shunt Regulator

Flasher IC with 18-mΩ Shunt U6043B

CA3012. FM IF Wideband Amplifier. Description. Features. Applications. Ordering Information. Schematic Diagram. Pinout.

Datasheet (Preliminary) Modular Inverter System VARIS Datasheet VARIS

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

New spectral benefi ts, proven low dose

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

Datasheet. Modular Inverter System VARIS Datasheet VARIS

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

Digital Radiography System

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power


E2V Technologies M5187F X-Band Magnetron

Disclosure to Promote the Right To Information

OEM s #1 Choice for X-Ray Sources and Generators. Focus on Performance, Reliability, Form Factor, and Versatility.

FT01MHNG FT01MVNG. 530 nm DC-1 MBd RedLink Fiber Optic Transmitter Datasheet DESCRIPTION FEATURES APPLICATIONS AVAILABLE OPTIONS

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

X-RAYS - NO UNAUTHORISED ENTRY

Transcription:

Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE The TOSHIBA XH-183 housing is developed for use in surgical C-arm application. It provides ease for use at a nominal patient table height. The heavy anode is constructed with specially processed rhenium-tungsten faced molybdenum target which has an improved coating to increase thermal emissivity. This tube has foci.6 and.3, and is available for a maximum tube voltage 125 kv. General Data IEC Classification (IEC661-1:25)... Class Ⅰ ME EQUIPMENT Application... Diagnostic Radiography for Mobile C-arm Electrical: Circuit: High Voltage Generator... Constant Potential High-Voltage Generator Grounding... Center-grounded Nominal X-ray Tube Voltage (IEC6613:21): Radiographic... 125 kv Fluoroscopic... 125 kv Nominal Focal Value (IEC6336:25): Large Focus....6 Small Focus....3 Nominal Anode Input Power (at.1s): Hz 6 Hz Large Focus... 2 kw 22 kw Small Focus... 7.4 kw 8 kw Nominal Radiographic Anode Input Power (IEC6613:21): Hz 6 Hz Large Focus... 19 kw 21 kw Small Focus... 6 kw 7 kw The information contained herein is presented only as a guide for the applications of our products. No Responsibility is assumed by TOSHIBA ELECTRON TUBES & DEVICES CO.,LTD.(TETD) for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TETD or others. The information contained herein may be changed without prior notice. It is therefore advisable to contact TETD before proceeding with the design of equipment incorporating this product.

Motor Ratings: Stator: XS-BB Starting Running Driven Frequency [Hz] / 6 / 6 Input Power [W] 4 Voltage 1) 3) [V] 12 4 Current 2) [A] 4 1.4 Min. Speed Up 4) [s] 1.2 - Capacitor [µf] 3 Note: 1) Applied voltage between common and main terminal. 2) Common current. 3) The every applied voltage must be never exceeded 11% of the above specification. 4) The speed-up time is allowed up to 11% of the above specification. Anode Speed: Hz... Minimum 27 min -1 6 Hz... Minimum 32 min -1 Stator Resistance: Common - Main Winding... 2 Ω Common - Auxiliary Winding... Ω Resistance between Housing and Low Voltage Terminals... Minimum 2 MΩ Normal Operating Range of the Housing Temperature... 16 ~ 75 C Mode of Operation... Intermittent Thermal Switch... Normally Closed Open... 82 ~ 88 Closed... 71 ~ 77 Mechanical: Dimensions... See dimensional outline Overall Length... 41 mm Maximum Diameter... 212 mm Target: Anode Angle... 1 degrees Diameter... 74 mm Construction... Rhenium-Tungsten-faced Molybdenum Filtration: Permanent Filtration....7 mm Al / 75 kv IEC6522:1999 Available Additional Filter combination (.4-1.5 mm)... Maximum 2.2 mm Al / 75 kv Radiation Protection (In accordance with IEC661-1-3:28): Leakage Technique Factor... 125 kv, 1.5 ma X-ray Coverage... 35 35 mm at SID mm Weight (Approx.)... 19 kg High Voltage Receptacle... PMI H1541 P2 (cathode) PMI H1541 P1 (anode) Cooling Method... Natural or forced air - 2 -

Absolute Maximum and Minimum Ratings (At any time, these values must not be exceeded.) Maximum X-ray tube Voltage (IEC6613:21): Radiographic... 125 kv Fluoroscopic... 125 kv Between Anode (or Cathode) and Ground... 62.5 kv Minimum X-ray Tube Voltage... 4 kv Maximum X-ray Tube Current (IEC6613:21)... See rating charts Large Focus... 2 ma Small Focus... ma Maximum X-ray Filament Current: Large Focus... 5. A Small Focus... 4.1 A Filament Voltage: Large Focus (At maximum filament current 5. A)... 1.1 ~ 12.3 V Small Focus (At maximum filament current 4.1 A)... 6.6 ~ 8.8 V Filament Frequency Limits... ~ 25 khz Continuous Anode Input Power (IEC6613:21)... 142 W (2 HU/s) (Fluoroscopic, repeated radiographic or mixed exposure) Thermal Characteristics: Anode Heat Content... 21 kj (3 khu) Maximum Anode Heat Dissipation... 87 W (1226 HU/s) X-ray Tube Assembly Heat Content... 1135 kj (16 khu) Nominal Continuous Input Power (IEC6613:21): Without Air-circulator... 177 W (15 khu/min) Environmental Limits Operating Limits: Temperature... 5 ~ 4 Humidity... 3 ~ 9 % (No condensation) Atmospheric Pressure... 7 ~ 16 kpa Shipping and Storage Limits: Temperature... -1 ~ 75 Humidity... 1 ~ 9 % (No condensation) Atmospheric Pressure... ~ 16 kpa - 3 -

Maximum Rating Charts (Absolute Maximum Rating Charts) Conditions: Tube Voltage Constant Potential High-Voltage Generator Stator Power Frequency Hz Nominal Focal Spot Value:.6 Nominal Focal Spot Value:.3 2 2 1 kv 11kV 75 25 kv 11kV.1.2.5.1.2.5 1 2 3 5 7 1.3.7.3.7 EXPOSURE TIME [s].1.2.5.1.2.5 1 2 3 5 7 1.3.7.3.7 EXPOSURE TIME [s] Refer to IEC6613:21 Conditions: Tube Voltage Constant Potential High-Voltage Generator Stator Power Frequency 6Hz Nominal Focal Spot Value:.6 Nominal Focal Spot Value:.3 2 2 1 kv 11kV 75 25 kv 11kV.1.2.5.1.2.5 1 2 3 5 7 1.1.2.5.1.2.5 1 2 3 5 7 1.3.7.3.7.3.7.3.7 EXPOSURE TIME [s] EXPOSURE TIME [s] Refer to IEC6613:21-4 -

Emission & Filament Characteristics Constant Potential High-Voltage Generator Nominal Focal Spot Value:.6 2 12 2 1 kv Ef 11 1 9 FILAMENT VOLTAGE [V] 8 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5 FILAMENT CURRENT [A] Note1) For Reference Only Note2) Refer to IEC6613:21 Nominal Focal Spot Value:.3 9 8 6 4 kv Ef 8 7 6 FILAMENT VOLTAGE [V] 2 5 3.5 3.6 3.7 3.8 3.9 4. 4.1 FILAMENT CURRENT [A] Note1) For Reference Only Note2) Refer to IEC6613:21 When using these emission curves for trial exposure, refer to the power rating curves shown for maximum KV, tube emission, filament current, exposure time, and target speed. - 5 -

Thermal Characteristics X-ray Tube Assembly Heating / Cooling Curve 12 COOLING HEAT STORAGE [kj] 8 6 4 2W 2 HEATING 2 4 6 8 12 TIME [min] Anode Heating / Cooling Curve 21 2 COOLING HEAT STORAGE [kj] 1 2W W HEATING 1 2 3 4 5 6 7 8 9 1 TIME [min] - 6 -

Dimensional Outline (1) Unit mm 41 246 86 212 192 Focal Spot Position No.8-32U-2B No.6-32U-2B 6-1/4-2U 137 89 65±.1 φ147 134±.1 18 65±.1 No.6-32U-2B 2-No.6-32U-2B 155.2±.5 25.8 Focal Spot Position 16 2.3-7 -

Dimensional Outline (2) Unit mm A-side View 147 137 B-side View 147 ANODE S CATHODE R38 L C 88 83 R74 NPT 1-8/27 (Depth 14) No.6-32U-2B (Depth 1) 8-No.1-32UNF-2B (Depth 14) 212 Symbol C:COMMON L:LARGE FOCUS S:SMALL FOCUS 89 A B - 8 -

Connector Wiring Diagram 6 4 3 5 2 CONNECTOR P1 (MOLEX 39-1-313) CONTACT PIN (MOLEX 39--54) CONNECTOR P4 (MOLEX 432-4) CONTACT PIN (MOLEX 4331-12) 2 3 4 5 6 7 8 9 2 3 4 CONNECTOR P2 (MOLEX 39-1-323) CONTACT PIN (MOLEX 39--54) CONNECTOR J2 (MOLEX 39-1-322) CONTACT PIN (MOLEX 39--28) 2 2 Symbol C :COMMON M :MAIN WINDING OF THE STATOR COIL A :AUX. WINDING OF THE STATOR COIL T1:TEMPERATURE RELAY :NON-CONNECTION C M A T TUBE HOUSING UNIT - 9 -

OVERSEAS SUBSIDIARIES AND AFFILIATES EU REPRESENTATIVE TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 4549 DÜSSELDORF, GERMANY PHONE +49 (211) 5296-17 FAX +49 (211) 5296-42 For Sales & Technical Services, please contact the following representative: TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 4549 DÜSSELDORF, GERMANY PHONE +49 (211) 5296-17 FAX +49 (211) 5296-42 TOSHIBA AMERICA ELECTRONIC COMPONENTS, I. 21 EAST LAKE COOK ROAD, SUITE 31 BUFFALO GROVE, ILLINOIS 689 USA PHONE +1 (847) 484-24 FAX +1 (847) 541-7287 TOSHIBA ELECTRON DEVICES & MATERIALS (SHANGHAI) CO., LTD. (TEMS) RM166, SH-PLAZA, No.336, XIZANG ROAD (MIDDLE), SHANGHAI, 21, CHINA PHONE +86 (21) 6361-77 FAX +86 (21) 6351-576 (Product Development Engineering Department) 1385 SHIMOISHIGAMI, OTAWARA-SHI, TOCHIGI-KEN, 324-85, JAPAN PHONE: +81-287-26-6666 FAX: +81-287-26-66 http://www.toshiba-tetd.co.jp/ Toshiba Electron Tubes & Devices Co., Ltd. meets the Environmental Management System Standard, ISO141. Toshiba Electron Tubes & Devices Co., Ltd. meets internationally recognized Standards for Quality Management System ISO91, ISO13485.