WIRING DIAGRAMS FOR SMART MODELS

Similar documents
STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

CIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 92 Series and 93 Series

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

PROCESS & TEMPERATURE CONTROLLERS

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Chapter 1 - Introduction to Mechatronics. Questions

vacon 100 flow ac drives application manual

UN2 - Universal controller Building automation s missing link

Configured air damper actuators 6FU11xx-xDxxx-xxxx

AC 01.2 Modbus TCP/IP

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

E3 Adjustable Speed Drive Engineering Specification

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

12V Dimmer Kit, version 2

ELECTRICAL ENGINEERING TECHNOLOGY PROGRAM EET 433 CONTROL SYSTEMS ANALYSIS AND DESIGN LABORATORY EXPERIENCES

LA-5000 SERIES LINEAR VALVE ACTUATORS

AC 01.2 HART Technical data Actuator controls

P5201 Universal Programmable Transmitters with Galvanic Isolation

CT325 Miniature DC Temperature Controller

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Electro Controls. Input-Output Modules WattsIndustries.co.uk

S11 Adjustable Speed Drive Engineering Specification

Analog Servo Drive 20A20

VF-nC1 Adjustable Speed Drive Engineering Specification

SPECIFICATION, CONTROLS AND ACCESSORIES

Specifications.

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Process Components. Process component

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

General Purpose Drives

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

DC1010/DC1020/DC1030/DC1040

Analog Servo Drive 25A20DD

NX Series Inverters. HVAC Pocket Programming Guide

Analog Servo Drive 30A8

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Small, Low-Voltage Digital Servo Drive

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Relay Driver Overview and Applications

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

AxCent Servo Drive A25A100

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

Temperature Controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Resistors and voltage. CSE1010 Jeffrey A. Meunier

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

RCDC2 Radio Controlled Device Controller- 2 channel

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Worcester Controls PB SMART PRODUCTS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

2010 Technological Studies. Standard Grade Credit. Finalised Marking Instructions

An important note about your Charged Up Exploration Kit.

Process controller with Modbus Master/Slave & PROFIBUS DP 1/8 DIN - 48 x 96 mm Platinum Series X5000 Line

PT8A3252/54 5LED Ceramic Heating Controller

Analog Servo Drive 30A8

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

RCMS460 and RCMS490 Series

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED.

Conductive Sensors 2 to 4-point level controller Type CL with potentiometer

POINTS POSITION INDICATOR

LAZERPOINT RF WIRELESS DOOR ACTIVATION SYSTEM

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Control solutions Biofloor

Home Map Projects Construction Soldering Study Components 555 Symbols FAQ Links

ELEXBO A-Car-Engineering

658 Current to Position Converters

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

Transmitters & Receivers

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

KNC-SRV-FD423 Series Servo Driver

AEE Solar Toroid Autotransformers. OutBack Power

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TEAM DIGITAL. Servette TM Single Servo Controller

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

SGD 70-A 7 PanelPilotACE Compatible Display

SPECIFICATION, CONTROLS AND ACCESSORIES

Rotary actuators for ball valves

SPECIFICATION, CONTROLS AND ACCESSORIES

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

HAW-Arduino. Sensors and Arduino F. Schubert HAW - Arduino 1

Industrial Automation Training Academy. Arduino, LabVIEW & PLC Training Programs Duration: 6 Months (180 ~ 240 Hours)

LTC3127EDD QUICK START GUIDE. 1A Buck-Boost DC/DC Converter with Programmable Input Current Limit DESCRIPTION

PID CONTROLLERS LT SERIES

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Microprocessor Control Board Set Up Procedures (OR PLC)

Signet 9950 Dual Channel Transmitter

KUBE Electronics AG. KUBE TR156 Universal PIR Circuit IC. For PIR Motion and Presence Detectors. Applications. Features

Wiring Information. Blinds & Shades

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

EY-EM 527: Remote I/O module, ecolink527

K3P ENG.qxd 23/10/ Pagina 1

EE Laboratory 4 - First Order Circuits *** Due in recitation on the week of June 2-6, 2008 ***

WIRELESS MODBUS GATEWAY WGW410

Transcription:

SMART SERIES CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: CONTROL WIRING CODE CONTROL WIRING TYPE 1 3 Wire system, single pole double throw, switching the live SPDT 2 3 Wire system, single pole single throw, make or break switch SPST 3 3 Wire system, 2 x single pole single throw, make or break switches SPST x 2 4 4 Wire System, 2 x single pole single throw, make or break switches SPST x 2 X Other factory special wiring FEEDBACK TYPE FEEDBACK TYPE CODE 1 3 Wire system, cam driven volt free single pole double throw switch SPDT 2 2 Wire system connected to motor switches to give powered output 3 3 Wire system, 10kΩ potentiometer 4 3 Wire System, volt free relay switch (relay for open, relay for closed) X Other factory special feedback ALARM ALARM CODE 0 No alarm A Relay powered alarm AVA CODE SYSTEM WIRING CREATED BY THE AVA CODE E 1 4 0 3 Wire, SPDT control with relays for open and for closed position feedback F 1 4 A 3 Wire, SPDT control with relays for open and for closed position feedback with alarm output G 2 4 0 3 Wire, SPST control with relays for open and for closed position feedback H 2 4 A 3 Wire, SPST control with relays for open and for closed position feedback with alarm output J 3 4 0 3 Wire, 2 x SPST control with relays for open and for closed position feedback K 3 4 A 3 Wire, 2 x SPST control with relays for open and for closed position feedback & alarm output L 3 1 A 3 Wire, 2 x SPST control with cam driven volt free SPDT feedback with alarm output M 4 X 0 4 Wire, 2 x SPST control N X 4 A 4 Wire, 2 x SPST control with relays for open and for closed position feedback & alarm output O-V 2 Wire permanent connection for all modulating control options W 2 Wire permanent connection for Modbus communication option X 2 Wire permanent connection for Canbus communication option Y 2 Wire permanent connection for Wireless option Z 2 Wire permanent connection for Timer option 1-6 2 Wire permanent connection for all modulating control options with alarm output

ON-OFF [OPEN / CLOSE] WIRING DIAGRAM: E E (Code 1-4-0) SPDT (Single pole, double throw) TO OPEN Connect live / +ve to 3 TO CLOSE Disconnect from 3, connect to 2 END OF TRAVEL CONFIRMATION Available, see wiring diagram F End of travel confirmation only available when external power is connected to the actuator. Note: Standard UK stock wiring configuration WIRING DIAGRAM: F F (Code 1-4-A) SPDT (Single pole, double throw) TO OPEN Connect live / +ve to 3 TO CLOSE Disconnect from 3, connect to 2 END OF TRAVEL CONFIRMATION End of travel confirmation and fault indication are only available when external power is connected Do not connect external power supply to this circuit WIRING DIAGRAM: G G (Code 2-4-0) SPST (Single pole, single throw) TO OPEN Connect live / +ve to 3 TO CLOSE Disconnect from 3 END OF TRAVEL CONFIRMATION Available, see wiring diagram H End of travel confirmation is only available when external power is connected to the actuator.

ON-OFF [OPEN / CLOSE] WIRING DIAGRAM: H H (Code 2-4-A) SPST (Single pole, single throw) TO OPEN Connect live / +ve to 3 TO CLOSE Disconnect from 3 Do not connect external power supply to this circuit END OF TRAVEL CONFIRMATION End of travel confirmation is only available when external power is connected to the actuator. MODULATING 0-20mA or 4-20mA WIRING DIAGRAM: O & P [DC POWER SUPPLY] O & P CONTROL SIGNAL I/O For Ref: O 0-20mA CONTROL SIGNAL I/O For Ref: P 4-20mA No, but available as an option. See wiring diagram ref: 1 or 2 O Closes P Can be configured to open, close, or stay put. WIRING DIAGRAM: 1 & 2 [DC POWER SUPPLY] Vout = Iout x Rx (use low TCR resistor for Rx) Vout 8V so Rx 400Ω Manufacturer recommends Vout=5V, RX= 250Ω/ 0.25W) 1 & 2 CONTROL SIGNAL I/O For Ref: 1 0-20mA CONTROL SIGNAL I/O For Ref: 2 4-20mA Do not connect external power supply to this circuit 1 Closes 2 Can be configured to open, close, or stay put.

MODULATING 0-20mA or 4-20mA WIRING DIAGRAM: O & P [FOR AC POWER SUPPLY] O & P CONTROL SIGNAL I/O For Ref: O 0-20mA CONTROL SIGNAL I/O For Ref: P 4-20mA No, but available as an option. See wiring diagram ref: 1 or 2 O Closes P Can be configured to open, close, or stay put. WIRING DIAGRAM: 1 & 2 [FOR AC POWER SUPPLY] Vout = Iout x Rx (use low TCR resistor for Rx) Vout 8V so Rx 400Ω Manufacturer recommends Vout=5V, RX= 250Ω/ 0.25W) 1 & 2 CONTROL SIGNAL I/O For Ref: 1 0-20mA CONTROL SIGNAL I/O For Ref: 2 4-20mA 1 Closes 2 Can be configured to open, close, or stay put. MODULATING 0-10V or 2-10V WIRING DIAGRAM: U & V [DC POWER SUPPLY] WIRING TYPE U & V Permanent supply across Blue (BU) and Red (RD) CONTROL SIGNAL I/O 0-10V CONTROL SIGNAL I/O 2-10V No, but available as an option. See wiring diagram ref: 5 U Actuator closes V Can be configured to open, close or stay put. Use low TCR resistor for Rx

MODULATING 0-10V or 2-10V WIRING DIAGRAM: U & V [AC POWER SUPPLY] U & V CONTROL SIGNAL I/O For Ref: U 0-10V CONTROL SIGNAL I/O For Ref: V 2-10V No, but available as an option. See wiring diagram ref: 5 or 6 U Closes V Can be configured to open, close, or stay put. Use low TCR resistor for Rx WIRING DIAGRAM: 5 & 6 5 & 6 CONTROL SIGNAL I/O For Ref: 5 0-1V CONTROL SIGNAL I/O For Ref: 6 2-10V 5 Closes 6 Can be configured to open, close, or stay put. Do not connect external power supply to this circuit Use low TCR resistor for Rx

SMART BUS COMMUNICATION WIRING DIAGRAM: W W [Modbus/ Canbus] Modbus CONTROL RS485 Modbus Recommended wiring when using bus actuators in parallel. WIRING DIAGRAM: X X [Canbus] WIRING TYPE Permanent supply across 1 and Red 2 CONTROL Canbus 2.0 Canbus CONTROL SIGNAL I/O Ref: V = 2-10V Closed

WIRING DIAGRAM: Y WIRELESS COMMUNICATION WIRING TYPE CONTROL Y Permanent supply across Blue (BU) and Red (RD) RF Radio frequency RF433/868M/915M FSK / LORA Modbus compatible. WIRING DIAGRAM: Y-OCEAN WIRING TYPE CONTROL Y OCEAN Permanent supply across Blue (BU) and Red (RD) RF-OCEAN [single control] Stays put Several OCEAN switches could control one actuator, or several actuators could be controlled by one OCEAN switch Recommended wiring when using wireless actuators in parallel.

TIMER WIRING DIAGRAM: Z WIRING TYPE CONTROL TIMER MODE LOOP MODE Z Permanent supply across Blue (BU) and Red (RD) Internal timer programmable by external push buttons Pulse or time mode Loop by days, or weeks ACCESSORIES: ANTI-CONDENSATION HEATER Heater 2 wire permanent supply Unless otherwise stated UK stock is fitted with an anti-condensation heater as standard.