High Voltage Trench MOS Barrier Schottky Rectifier Ultra Low V F = 0.54 V at I F = 5 A TO-220AB V2020SG PIN PIN 2 PIN 3 CASE 2 3 TMBS ITO-220AB 2 3 VF2020SG PIN PIN 2 PIN 3 FEATURES Trench MOS Schottky technology Low forward voltage drop, low power losses High efficiency operation Meets MSL level, per J-STD-020, LF maximum peak of 245 C (for TO-263AB package) Solder bath temperature 275 C maximum, 0 s, per JESD 22-B06 (for TO-220AB, ITO-220AB, and TO-262AA package) Material categorization: for definitions of compliance please see /doc?9992 NC A VB2020SG DESIGN SUPPORT TOOLS Models Available D 2 PA (TO-263AB) PRIMARY CHARACTERISTICS I F(AV) 20 A V RRM 20 V I FSM 50 A V F at I F = 20 A 0.78 V T J max. 50 C Package NC Circuit configuration A HEATSIN PIN PIN 3 TO-262AA VI2020SG PIN 2 TO-220AB, ITO-220AB, D 2 PA (TO-263AB), TO-262AA Single click logo to get started 2 3 TYPICAL APPLICATIONS For use in high frequency converters, switching power supplies, freewheeling diodes, OR-ing diode, DC/DC converters and reverse battery protection. MECHANICAL DATA Case: TO-220AB, ITO-220AB, D 2 PA (TO-263AB), and TO-262AA Molding compound meets UL 94 V-0 flammability rating Base P/N-E3 - RoHS-compliant, commercial grade Terminals: matte tin plated leads, solderable per J-STD-002 and JESD 22-B02 E3 suffix meets JESD 20 class A whisker test Polarity: as marked Mounting Torque: 0 in-lbs maximum MAXIMUM RATINGS ( unless otherwise noted) PARAMETER SYMBOL V2020SG VF2020SG VB2020SG VI2020SG UNIT Maximum repetitive peak reverse voltage V RRM 20 V Maximum average forward rectified current (fig. ) I F(AV) 20 A Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load I FSM 50 A Non-repetitive avalanche energy at T J = 25 C, L = 60 mh E AS 80 mj Peak repetitive reverse current at t p = 2 μs, khz, T J = 38 C ± 2 C I RRM 0.5 A Voltage rate of change (rated V R ) dv/dt 0 000 V Isolation voltage (ITO-220AB only) from terminal to heatsink t = min V AC 500 V Operating junction and storage temperature range T J, T STG -40 to +50 C Revision: 8-Jun-208 Document Number: 88994 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9000
ELECTRICAL CHARACTERISTICS ( unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TYP. MAX. UNIT Breakdown voltage I R =.0 ma V BR 20 (minimum) - V I F = 5 A 0.62 - I F = 0 A 0.8 - Instantaneous forward voltage I F = 20 A.20.33 I F = 5 A V () F 0.54 - V I F = 0 A 0.65 - I F = 20 A 0.78 0.88 Reverse current V R = 90 V 0-7 µa - ma V R = 20 V I (2) R - 250 µa 2 25 ma Notes () Pulse test: 300 μs pulse width, % duty cycle (2) Pulse test: Pulse width 40 ms THERMAL CHARACTERISTICS ( unless otherwise noted) PARAMETER SYMBOL V2020SG VF2020SG VB2020SG VI2020SG UNIT Typical thermal resistance R JC 2.2 4.2 2.2 2.2 C/W ORDERING INFORMATION (Example) PACAGE PREFERRED P/N UNIT WEIGHT (g) PACAGE CODE BASE QUANTITY DELIVERY MODE TO-220AB V2020SG-E3/4W.88 4W 50/tube Tube ITO-220AB VF2020SG-E3/4W.75 4W 50/tube Tube TO-263AB VB2020SG-E3/4W.38 4W 50/tube Tube TO-263AB VB2020SG-E3/8W.38 8W 800/reel Tape and reel TO-262AA VI2020SG-E3/4W.45 4W 50/tube Tube RATINGS AND CHARACTERISTICS CURVES ( unless otherwise noted) Average Forward Current (A) 25 20 5 0 5 Resistive or Inductive Load VF2020SG Mounted on Specific Heatsink V(B,I)2020SG Average Power Loss (W) 35 30 25 20 5 0 5 D = 0. D = 0.2 D = 0.3 D = 0.8 D = 0.5 D =.0 T D = t p /T t p 0 0 25 50 75 00 25 50 75 Case Temperature ( C) Fig. - Forward Current Derating Curve 0 0 4 8 2 6 20 24 Average Forward Current (A) Fig. 2 - Forward Power Loss Characteristics Revision: 8-Jun-208 2 Document Number: 88994 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9000
Junction Capacitance (pf) Transient Thermal Impedance ( C/W) Transient Thermal Impedance ( C/W) Instantaneous Forward Current (A) 00 0 T A = 50 C T A = 00 C 0 Junction to Case V(B,I)2020SG 0. 0 0.2 0.4 0.6 0.8.0.2.4.6 Instantaneous Forward Voltage (V) Fig. 3 - Typical Instantaneous Forward Characteristics 0.0 0. 0 00 t - Pulse Duration (s) Fig. 6 - Typical Transient Thermal Impedance Instantaneous Reverse Current (ma) 00 T A = 50 C 0 T A = 00 C 0. 0.0 0.00 0 20 30 40 50 60 70 80 90 00 Percent of Rated Peak Reverse Voltage (%) Fig. 4 - Typical Reverse Characteristics 0 Junction to Case VF2020SG 0. 0.0 0. 0 00 t - Pulse Duration (s) Fig. 7 - Typical Transient Thermal Impedance 0 000 T J = 25 C f =.0 MHz V sig = 50 mvp-p 000 00 0 0. 0 00 Reverse Voltage (V) Fig. 5 - Typical Junction Capacitance Revision: 8-Jun-208 3 Document Number: 88994 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9000
PACAGE OUTLINE DIMENSIONS in inches (millimeters) 0.45 (0.54) 0.380 (9.65) 0.6 (4.08) 0.39 (3.53) 0.3 (2.87) 0.03 (2.62) TO-220AB 0.85 (4.70) 0.75 (4.44) 0.055 (.39) 0.045 (.4) 0.60 (4.06) 0.40 (3.56) 0.057 (.45) 0.045 (.4) PIN 2 3 0.635 (6.3) 0.625 (5.87) 0.350 (8.89) 0.330 (8.38).48 (29.6).8 (28.40) 0.560 (4.22) 0.530 (3.46) 0.603 (5.32) 0.573 (4.55) 0.0 (2.79) 0.00 (2.54) 0.035 (0.90) 0.04 (2.65) 0.028 (0.70) 0.096 (2.45) 0.205 (5.20) 0.95 (4.95) 0.022 (0.56) 0.04 (0.36) Revision: 8-Jun-208 4 Document Number: 88994 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9000
TO-262AA 0.4 (0.45) 0.380 (9.65) 0.055 (.40) 0.047 (.9) 0.85 (4.70) 0.75 (4.44) 0.055 (.40) 0.045 (.4) 0.950 (24.3) 0.920 (23.37) 0.60 (4.06) 0.40 (3.56) 0.057 (.45) 0.045 (.4) PIN 2 3 0.50 (2.95) 0.470 (.94) 0.350 (8.89) 0.330 (8.38) 0.560 (4.22) 0.530 (3.46) 0.40 (0.9) 0.38 (9.68) 0.0 (2.79) 0.00 (2.54) 0.04 (2.65) 0.096 (2.45) 0.035 (0.90) 0.028 (0.70) 0.205 (5.20) 0.95 (4.95) 0.022 (0.56) 0.04 (0.35) 0.4 (0.45) 0.380 (9.65) 0.245 (6.22) MIN. D 2 PA (TO-263AB) 0.90 (4.83) 0.60 (4.06) 0.055 (.40) 0.045 (.4) Mounting Pad Layout 0.42 (0.66) MIN. 0.33 (8.38) MIN. 0.360 (9.4) 0.320 (8.3) NC A 0.624 (5.85) 0.59 (5.00) 0.055 (.40) 0.047 (.9) 0.670 (7.02) 0.59 (5.00) 0.037 (0.940) 0.027 (0.686) 0.05 (2.67) 0.095 (2.4) 0.205 (5.20) 0.95 (4.95) 0 to 0.0 (0 to 0.254) 0.0 (2.79) 0.090 (2.29) 0.02 (0.53) 0.04 (0.36) 0.40 (3.56) 0.0 (2.79) 0.08 (2.032) MIN. 0.05 (2.67) 0.095 (2.4) 0.5 (3.8) MIN. Revision: 8-Jun-208 5 Document Number: 88994 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9000
Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, Vishay ), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer s technical experts. Product specifications do not expand or otherwise modify Vishay s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. 207 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-7 Document Number: 9000