T3 / T4 Series Features Various size as DIN specifications (W H24, W72 H36, W96 H, W H, W H96, W72 H72, W96 H96mm) Please read Safety Considerations in operation manual before using. Ordering Information T 3 S I N 4 N P 4 C N New 1 Temperature unit Temperature range 3 N C New type -99.9 to 99.9, -99 to 199, -99.9 to 199.9 1 to 99.9 2 to 2 4 to 4 5 to 5 8 to 8 to 999 C to 12 F 6 to 16 Input type 3 Control output P J K R N DPt1Ω J(IC) K(C) R(PR) Indicator larm/sub output Power supply Control method X 12-24VDC 4 1-24VC 5/6Hz N Indicator I Indicator Item Digit Size N DIN W H24mm Y DIN W72 H36mm W DIN W96 Hmm S DIN W Hmm (8-pin plug type) 2 H DIN W H96mm M DIN W72 H72mm L DIN W96 H96mm 3 999 (3-digit) 4 9999 (4-digit) T Temperature Controller 1: Name plate and connections are different from previous T3/T4 Series. 2: Sockets (PG-8, PS-8(N)) are sold separately. H-116
3: Input type and temperature range by Series Input type Thermocouples K(C) J(IC) Specifications to 2 2 to 4 4 to 8 8 to 999 to 12 C to 2 2 to 4 4 to 5 5 R(PR) 6 to 16 F DPt 1Ω -99.9 to 99.9-99.9 to 199.9-99 to 199 to 99.9 1 to 2 2 Series Model to 4 4 Please contact us for temperature unit model. T3NI T4YI, T4WI Series T3NI T4YI T4WI T3SI T3HI T4MI T4LI Power supply 12-24VDCᜡ 1-24VCᜠ 5/6Hz llowable voltage range 9 to 11% of rated voltage Power consumption Max. 1W Max. 3V Display method 7-segment (red) LED method Character size (W H) 3.8 7.6mm 8. 14.2mm 3.8 7.6mm 6. 1.mm 8. 14.2mm Input type DPt1Ω (allowable line resistance max. 5Ω per a wire) T3SI T3HI T4MI, T4LI K(C), J(IC) K(C), J(IC), R(PR) Display t room temperature (23ºC ± 5ºC): (PV ±.5% or ±1ºC, select the higher one)±1-digit accuracy 1 Out of room temperature range: (PV±.5% or ±2ºC, select the higher one)±1-digit Sampling period Dielectric strength Vibration Insulation resistance Noise immunity Environment Weight 2 mbient temp. mbient humi. 1ms 1,VC 5/6Hz for 1 min (between input terminal and power terminal) 2,VC 5/6Hz for 1 min (between input terminal and power terminal).75mm amplitude at frequency of 1 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours Over 1MΩ (at 5VDC megger) Square-wave noise by noise simulator (pulse width 1 μs ) ±5V R-phase and S-phase -1 to 5, storage: -2 to 6 Square-wave noise by noise simulator (pulse width 1 μs ) ±2kV R-phase and S-phase 35 to 85% RH, storage: 35 to 85% RH pprox. g (approx. 25g) pprox. 181g pprox. 231g pprox. 12g pprox. 23g pprox. 22g pprox. 274g (approx. 123g) (approx. 14g) (approx. 8g) (approx. 7g) (approx. 7g) (approx. 185g) 1: In case of the T3NI, T3SI Series and the decimal point display models t room temperature (23ºC±5ºC): (PV ±.5% or ±2, select the higher one)±1-digit Out of room temperature range: (PV ±.5% or ±3, select the higher one)±1-digit 2: The weight includes packaging. The weight in parenthesis is for unit only. Environment resistance is rated at no freezing or condensation. () Photoelectric () Fiber Optic (C) Door/rea (D) Proximity (E) Pressure (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution oxes/sockets (H) Temperature (I) SSRs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software H-117
T3 / T4 Series Connections Use teminals of size specified below. <Round> a b <Forked> a Min. 3.5mm Min. 3.5mm b Max. 7.2mm Max. 7.2mm a b T3NI T4YI 4 3 2 1 12-24VDC 1W 1-24VC 5/6Hz 3V T4WI 1-24VC 5/6Hz 3V T3SI T4MI 1-24VC 5/6Hz 3V 1-24VC 5/6Hz 3V T3HI, T4LI 1-24VC 5/6Hz 3V H-118
Dimensions T3NI 52 4 4 8 () Photoelectric () Fiber Optic 24 21 (C) Door/rea T4YI (D) Proximity 72 7 1 8 (E) Pressure 36 3 (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution oxes/sockets T4WI 96 12 112 9 (H) Temperature (I) SSRs / Power 45 (J) Counters (K) Timers T3SI 12.3 1.5 9.1 63.8 (L) Panel (M) Tacho / Speed / Pulse 45 (N) Display Units (O) Sensor T3HI 83 7 (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels 96 (S) Field Network Devices (T) Software H-119
T3 / T4 Series T4MI 72 11.8 89.3 75 T4LI 96 12.5 82.5 7 67.5 racket T3NI Series T4YI Series T4WI Series 42 73 3 28.8 22 36.28 12 1 4.4 2 3.5 53.5 45.2.6 3.5 32.4 26.4 T3SI Series T3HI/T4MI/T4LI Series 45.4 61 4 1 3.3 3.5 1 11.6 7.9 1 46 4.5 4.2 41 3.9 37.5 4.5 15 7.4 12.2 47.8 61 12 23.9 H-12
Terminal cover (sold separately) RM-COVER (72 72mm) 7 3 RL-COVER (96 96mm) RH-COVER ( 96mm) 47.2 4 () Photoelectric () Fiber Optic 68.5 64 386 94 86 (C) Door/rea (D) Proximity (E) Pressure (F) Rotary Encoders Panel cut-out (G) Connectors/ Connector Cables/ Sensor Distribution oxes/sockets (H) Temperature D Series Size C D T3NI Min. 55 Min. 37 45 +.5 22.2 +.3 (I) SSRs / Power T4YI Min. 91 Min. 4 68 +.7 31.5 +.6 C T4WI Min. 116 Min. 52 92 +.8 45 +.6 T3SI Min. 65 Min. 65 45 +.6 45 +.6 (J) Counters T3HI Min. 65 Min. 115 45 +.6 92 +.8 T4MI Min. 9 Min. 9 68 +.7 68 +.7 T4LI Min. 115 Min. 115 92 +.8 92 +.8 (K) Timers Display When Power Is ON When power is supplied, whole display parts turn ON for 1 sec. It displays model type (digits, size, alarm/sub output and control output, sensor, temp. range, unit). fterward, it returns to RUN mode. Whole parts turn ON Error Display Display Description Troubleshooting OPEN HHHH LLLL Displays digits, size, alarm/sub output When input sensor break/sensor is not connected, it displays [OPEN]. In case of normal operation, it displays the present input temperature. Flashes when a temperature sensor is broken or not connected. Flashes when the measured input value is higher than the temperature range of the sensor. Flashes when the measured input value is lower than the temperature range of the sensor. Displays control output, sensor, temp. range, unit When input sensor break/sensor is not connected RUN mode Normal operation Check the status of the temperature sensor. When the sensor is connected correctly, it is clear. When the measured temperature is within the temperature range of the sensor, it is clear. (L) Panel (M) Tacho / Speed / Pulse (N) Display Units (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software H-121