TENDER shedule. Sealed tenders in the prescribed format are invited for the purchase of equipments for various labs for Electronics Departments.

Similar documents
1. A transducer converts

Biomedical Electrodes, Sensors, and Transducers. Definition of Biomedical Electrodes, Sensors, and Transducers. Electrode: Sensor: Transducer:

Series GLET Accessory for dataloggers series GL in modular enclosure

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

An Instrumentation System

PRODUCT CATALOG TRAINER KITS FOR ENGINEERING DEGREE COURSES MICROTECH INDUSTRIES

INVITATION FOR QUOTATION. TEQIP-II/2017/btec/Shopping/2

Quantity available (A) Quantity required (R) Sl. No. Deficiency (R - A) Description of Equipment

M.D. Singh J.G. Joshi MECHATRONICS

Sensors (Transducer) Introduction By Sintayehu Challa

MECE 3320 Measurements & Instrumentation. Data Acquisition

ni.com Sensor Measurement Fundamentals Series

SENSOR AND MEASUREMENT EXPERIMENTS

Exercise 2: Temperature Measurement

Lesson Plan. Name of the Faculty : Discipline : Electrical Engineering Semester : 4 th Semester. Lesson Plan Duration : Week

Operating Manual Ver.1.1

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

Unit 2 Semiconductor Devices. Lecture_2.5 Opto-Electronic Devices

INSTRUCTION MANUAL PCE-222

P-CUBE-Series High Sensitivity PIN Detector Modules

400 MHz Photoreceiver with Si PIN Photodiode

Instrumentation Amplifier Module. Instruction Manual

MECHANICAL ENGINEERING SYSTEMS LABORATORY

IS-3000 SERIES INFRARED SCANNER

Conversion of a DC-AC inverter to 400 Hz

LAB 1 AN EXAMPLE MECHATRONIC SYSTEM: THE FURBY

TRACEABLE MEASUREMENT CAPABILITY

PHYSICS 330 LAB Operational Amplifier Frequency Response

Chapter 1: Introduction

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

INVITATION FOR QUOTATION. TEQIP-II/2013/UP1G01/Shopping/39

Exp. No. 13 Measuring the runtime of light in the fiber

Chapter 10 Switching DC Power Supplies

CATALOG. ANALOG COMMUNICATION SYSTEMS DIGITAL COMMUNICATION SYSTEMS Microcontroller kits Arm controller kits PLC Trainer KITS Regulated Power supplies

Great Britain: LASER COMPONENTS (UK) Ltd., Phone: , Fax: , France: LASER COMPONENTS

5. Transducers Definition and General Concept of Transducer Classification of Transducers

UNIVERSITY OF NAIROBI COLLEGE OF BIOLOGICAL AND PHYSICAL SCIENCES FACULTY OF SCIENCE SPH 307 INTRODUCTORY ELECTRONICS

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

M70LL Laser Distance Sensor

Measurement system applications. Measurement System

Electronics II. Calibration and Curve Fitting

Operational Amplifiers

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

INVITATION FOR QUOTATION. TEQIP-II/2013/UP1G01/Shopping/43

Lecture 14 Interface Electronics (Part 2) ECE 5900/6900 Fundamentals of Sensor Design

Signal Conditioning Systems

INVITATION FOR QUOTATION. TEQIP-II/2015/UP1G01/Shopping/60

Electronic Circuits EE359A Final project requirements

200 MHz Photoreceiver with Si PIN Photodiode

CONTA-ELECTRONICS. Converter Units

ADVANCE DIGITAL COMMUNICATION LAB

High-Speed Photoreceiver with Si PIN Photodiode

DRG-SC Series Signal Conditioners

ANALOG TO DIGITAL CONVERTER ANALOG INPUT

CERTIFICATE OF ACCREDITATION

Displacement Sensors Miniature Displacement Sensors SM/MD/DF

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

Mechanical 0.3% 1 to 9999 RPM 1% of reading Tachometer. Up to 24 hours/0.01 Sec 1 Sec Master Stopwatch and Manual Comparison Chemical

33609/J Limiter/Compressor

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

CHEMICAL ENGINEERING 2I03

Indian Institute of Information Technology, Pune

611 Strain gauge transducer amplifier ELECTRONICS

GSV-2MSD-DI IP43. Highlights

DIGITAL ELECTRONICS ANALOG ELECTRONICS

* Notebook is excluded. Features KL-720 contains nine modules, including Electrocardiogram Measurement, E lectromyogram Measurement,

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION (Autonomous) (ISO/IEC Certified) MODEL ANSWER

Downloaded from Downloaded from

INVITATION FOR QUOTATION. TEQIP-III/2018/vecl/Shopping/82

Question Bank SENSORS AND INSTRUMENTATION [EE-305/405]

Improved Radiometry for LED Arrays

R & D Electronics DIGITAL IC TRAINER. Model : DE-150. Feature: Object: Specification:

Operating Manual Ver.1.1

V-LAB COMPUTER INTERFACED TRAINING SET

Electronic Components

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

MAE334 - Introduction to Instrumentation and Computers. Final Exam. December 11, 2006

LAB ASSIGNMENT No. 1 Characteristics of IC Temperature Sensor (LM 335)

Operating Manual Ver.1.1

MADE FOR THE TRADE! XL fibertools Series

Connecting Mains Electrical Power

MCTS II Multi Channel Current Transducer System. Installation Manual

Variable Gain Photoreceiver - Fast Optical Power Meter

Chapter 8. Digital and Analog Interfacing Methods

200 MHz Variable Gain Photoreceiver

University Visvesvaraya College of Engineering

Power MOSFET Stage for Boost Converters

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002)

PRACTICAL DESIGN TECHNIQUES FOR SENSOR SIGNAL CONDITIONING

ECE 454 Homework #1 Due 11/28/2018 This Wednesday In Lab

1 Lock-in Amplifier Introduction

Experiments with wave, using low-cost amplitude modulated ultrasonic techniques

Developer Techniques Sessions

INVITATION FOR QUOTATION. TEQIP-III/2018/uiej/Shopping/23

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

Lecture 4. Integrated Electronics

Operating Manual Ver.1.1

Transcription:

MODEL ENGINEERING COLLEGE THRIKKAKA,COCHIN-2 PH:2577379,2575370 Ref no.a2/273/7/mec dtd 29..207 Tender No.6/207-8/MEC TENDER shedule Sealed tenders in the prescribed format are invited for the purchase of equipments for various labs for Electronics Departments..Last date and time of sale of tender form:5//208 0 am 2.Last Date & Time of Reciept of Tender: 5//208 am 3.Date & Time of Opening of Tender:5//208 2 P M Cost of Tender Form: Original : 400 + 8% GST Duplicate :200 + 8% GST Tender form and details can be had from Model Engineering College,Thrikkakara. Mode of remmittance by Cash payment at College Office.Those who apply for tender form by post should remit additional amount of Rs.50/- as postal charges.agreement in stamp paper worth Rs.200/- to accompany tender. Further details available at www.mec.ac.in/ Tenders. PRINCIPAL

MODEL ENGINEERING COLLEGE THRIKKAKA,COCHIN-2 PH:2577379,2575370 Ref no.a2/273/7/mec dtd 29..207 Tender No.6/207-8/MEC Specification of Equipments of Electronis department Sl no Item Specification qty Mounted High Power LED with power supply Wavelength: 420nm, 450nm, 530nm, 620nm, 640nm Spectral width : 40 to 80nm Collimated optical power output : > 2.5w Power output : 2mw, 3mw, 0mw, 2 High Intensity Lux Meter Max Range: 4,00,000 Lux Accuaracy: ± 5% ± 0d for all ranges Max resolution: 0. lux / Fc 3 Optical Power Meter Wavelength range : 850 nm / 30 nm / 550 nm Resolution : 0.0 db Detector type : Si photo diode Detector range : 0 to -50dB 4 Transducer system using diode thermometer 0 to 00 C Option to plot characteristics Digital display for temperature indicator Glass epoxy PCB Heating equipment with temperature monitoring Test points User s Manual with sample experiments 5 Transducer system using LVDT LVDT Transducer should be visible Displacement of ± 5mm or more Provision for Current and Voltage output On-board Digital Panel Meter

Screw Gauge for displacement Onboard Instrumentation Amplifier Test points All ICS should be mounted on Sockets. Glass Epoxy PCB Built in Power Supply of +5V,A, ±2V 250mA User s Manual with sample experiments 6 Transducer system using Strain Gauge Resistive load cell Load in weights 2 Kgs. Provision for Voltage and Current output On-board Digital Panel Meter Weights can be verified by Physical counting of weights Weights with different denominations Onboard Instrumentation Amplifier Test points All ICS should be mounted on Sockets. Glass Epoxy PCB In-Built Power Supply of +5V A, ±2V, 250mA User s Manual with sample experiments 7 Transducer system using Pressure Transducer Resistive Transducer should be visible. pressure of 0-200mm Hg or Provision for voltage and Current output On-board Digital Panel Meter Pressure generation and Monitoring On board Instrumentation Amplifier Test points All ICS should be mounted on Sockets. Glass Epoxy PCB In-Built Power Supply of +5V,A, ±2V,250mA User s Manual with sample experiments

8 Transducer system using Thermocouple 0 to 00 C Thermocouple -K or J or R Type On-board Digital Panel Meter Heating equipment with temperature monitoring On board Instrumentation Amplifier Test points All ICS should be mounted on Sockets. Glass Epoxy PCB In-Built Power Supply of +5V,A, ±2V,250mA User s Manual with sample experiments 9 Transducer system using RTD 0 to 00 C PT-00 -type RTD Sensor On-board Digital Panel Meter provided Heating equipment with temperature monitoring Onboard Instrumentation Amplifier Test points All ICS should be mounted on Sockets. Glass Epoxy PCB In-Built Power Supply of +5V,A, ±2V,250mA User s Manual with sample experiments

0 Transducer system using Photocells 0 to 000 Lux or Above Photo conductive cell, Photo voltaic cell, Photo transistor, PiN Photo diode Digital display Lighting Equipment with monitoring (using Lux Meter) In-Built Power Supply of +5V,A, ±2V,250mA Glass epoxy PCB Test points User s Manual with sample experimental programs Boost DC-DC Converter 2 Push Pull DC-DC Converter set up 3 Buck DC-DC Converter set up Output voltage can be varied from 5V or to 24V or Output power - 0 W or overload protection Output voltage 2V or Output power - 00 W or overload protection

Output voltage can be varied from 0V to 2V or Output power 0 W or 4 Buck -boost DC-DC Converter set up Output voltage 0V to 2V or Output power 0 W or 5 SMPS set up 6 Half bridge and full bridge Converter set up Inbuilt power &load Facility to measure efficiency Facility to load SMPS Isolation transformer Output: +2V or +5 V, A or -2V or -5 V, A or +5V, 5A or Various test points to observe signals Product tutorial

7 Basic Inverter Circuit set up output voltage 2V or Output power - 00 W or overload protection Square wave and sine wave output Output voltage 220 VRMS Output frequency 50 Hz Input DC should be 2V or 24 V Provision to connect external battery / BJT Output power - 00 W or Short circuit and overload protection Inbuilt power &load PRINCIPAL