When is a Building Permit Required? Deck Details: What Must be Submitted with a Building Permit Application?

Similar documents
DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

FREDERICK COUNTY USBC/IRC 2015

Deck Evaluation Checklist

Typical Deck Details

Typical Deck Details

APPLICATION FOR A BUILDING PERMIT

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

City of Virginia Beach, Virginia Typical Deck Details

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. Based on the 2015 International Residential Code

DECK PERMIT APPLICATION PACKET

Deck Design Guide. One and Two Family Residential Dwellings

Prescriptive Residential Wood Deck Construction Guide Based on the 2006 International Residential Code

Residential Decks. Typical Deck Details DECKING REQUIREMENTS

Maryland Building Officials Association Typical Deck Details

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

Typical Deck Details

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

3.1 General Provisions

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

Attached/Detached Patio Cover

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

Page 1 of 70

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

BUILDING & SAFETY DIVISION 110 E. LA HABRA BLVD. LA HABRA, CA Rev. 06/17

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016

Step 2 - Measure and install joist hangers every 16". See Figure "B" above. Fill every hole in each

Load Tables, Technical Data and Installation Instructions

Bedroom Window Egress

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

PAINT & MISC. Notes. Table of Contents. Front Handrail Posts Front Handrails Closet Shelving Exterior Deck...

NEW SINGLE FAMILY HOMES

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

Perennial Wood Decking Installation Guide

Call (770) STEP 6: Caulk bolt hole within the bracket for protection from the elements.

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

Featuring TJ Rim Board and TimberStrand LSL

TO WHOM IT MAY CONCERN:

Garage Design Guide. October 2018

Ohlson Project Property Owner: Kathy Ohlson Property Address: Deer Lake Rd. Derwood MD 20855

SDWH TIMBER-HEX Screw

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

BUILDING PLANS. BUILDING DEPARTMENT

APA Performance Rated Rim Boards

REVISION CHANGES: REV. NO. REV. DATE

TRELLIS. Trellis SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

COMPACT DECK. Compact Deck SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION

FASTENERS BUILDING DEPARTMENT


A ledger/header board is the next step if you are attaching your deck to an existing structure.

Ocean View. Deck Planner Software Report for Simpson Template. 1 All rights reserved copyright 2017 DIY Technologies

ICC-ES Evaluation Report

Lateral Tension System

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

Build Outdoor Stairs. Stair Building Terms There are five basic design elements you'll need to consider when planning outdoor stairs:

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

Determine the stairway pitch based on tread and riser dimensions. For the main stairway in a house, the pitch can be no greater than 37º.

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

ROOF-CEILING CONSTRUCTION

Single-Family Dwelling Submittal Requirements

Chapter 33: Lofts (Or Second Floors)

How to Build Good Decks..

RESIDENTIAL BUILDING PERMIT REQUIREMENTS

THE ENGINEERED WOOD ASSOCIATION

The maximum back wall height is eight-feet three-inches (8 3 ), including truss, and is allowed only in the rear half of the booth space.

Installation Guide. 203 Chesterra Drive, Dahlonega, GA Toll-Free ~ Fax ~

G. SAMPLE DRAWINGS AND ILLUSTRATIONS INDEX

Main Floor Revisions: 38' 0" Rm1 H3 50' 0" Bk1 B1 Rm2 B5 (26)-2 H2 B2 H3 (3)-3 B3 (11)-4 Bk1 B1 (5)-5 Rm4 Bk1 Rm3 Bk1 24' 0" 6' 0" 20' 0" START FRAMIN

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

ROOF-CEILING CONSTRUCTION

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

12' Octagon Wood Gazebo

SUMMIT 36 Barn Kit - EQUINE PACKAGE

Exterior Wall Fastener Schedule

Wall bracing is one of the most important structural elements of

Build Like a Pro: Building a Deck

RAPID RIVER RUSTIC, INC.

10x10 Shed Plans and Building Guide

Accessory Dwelling Unit Prototype 4 Plan Sets. Prototype 4: Detached 1- Story ADU using alternate materials and techniques

Vertical Offset Base and Safety Rail System Installation Instructions

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER:

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW SINGLE-FAMILY DWELLING

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

Multi-Stage ASSEMBLY INSTRUCTIONS ST-8100 SERIES. 125 TAYLOR PARKWAY ARCHBOLD, OH PHONE: (419) FAX: (419)

PLAN SUBMITTAL REQUIREMENTS

IN T E R N A T I O N A L

E-Blueprints. Children s Backyard Playhouse 8 x sq. feet main 32 sq feet porch 2 x 4 Framed Walls 6' Ceiling Height

STORAGE SHED. Storage Shed SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

6x6 Shed Plans and Building Guide

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems

Solving Porch Problems

Transcription:

P.O. Box 1190, Fort Collins, Colorado 80522-1190, Planning (970) 498-7683, Building (970) 498-7700, Larimer.org When is a Building Permit Required? A permit is required if ANY of the following is true: Deck is greater than 30 inches above ground, OR Deck serves as the main entry/exit to a structure. If NONE of these are true, no permit is required. Note: Decks must meet setback requirements of the Larimer County Land Use Code, whether or not a permit is required. For setback information, please call the Planner on Call at (970) 498-7679. What Must be Submitted with a Building Permit Application? Residential Building Permit Application form. Two (2) full sets of plans drawn to scale (for example, 1/8, 3/16 or 1/4 = 1 ), including plan view, cross sections, and elevations, showing all structural elements including footings, posts, beams, joists, ledger and connections. Seven (7) copies of plot plans drawn to scale (see plot plan handout). Check, cash or credit card for plot plan and plan review fee. Deck Details: All lumber must be treated or naturally decay-resistant. Piers or pads are required to support a deck. If attached to the structure, footings must be minimum 30 below grade. Foundation plan must be stamped by a Colorado Registered Engineer if location or design warrants. For attached decks: If deck surface is 10 above surrounding grade at any point it must be x-braced. For detached decks: If deck surface is 5 above surrounding grade at any point it must be x-braced. If deck exceeds 30 above grade, a guardrail is required, 36 in height minimum, with intermediate railings spaced such that a 4 sphere cannot fit through, including between bottom rail and deck. If installing stairs, stair rise must be a minimum of 4 and a maximum of 7 ¾. Tread run must be a minimum of 10 with ¾ to 1 ¼ nosing. Elimination of nosing requires an 11 minimum run. Variation of rise or run over the entire stairs shall not exceed 3 /8". Openings between open risers shall not allow exceed 4. If more than three risers are installed, a continuous, graspable stair handrail is required, 34 to 38 above the tread nosing, returned to posts at top and bottom, with maximum 4 3 /8 spacing between rails. Graphic from Colorado Chapter of the International Code Council See attached pages for deck details and allowed spans. NEED MORE INFORMATION? Contact the Building Department at 970-498-7700

DECK BEAM SPAM (Based on 45 psf Ground Snow Load & 10 psf Dead Load for elevations below 6000 ) 6 7 8 9 10 11 12 13 14 15 4 2-2x6 s 2-2x6 s 2-2x6 s 2-2x8 s 2-2x8 s 2-2x8 s 2-2x10 s 2x2x10 s 2x2x10 s 2-2x12 s 5 2-2x6 s 2-2x6 s 2-2x8 s 2-2x8 s 2-2x8 s 2-2x10 s 2-2x10 s 2x2x12 s 2x2x12 s 3-2x12 s 6 2-2x6 s 2-2x6 s 2-2x8 s 2-2x8 s 2-2x10 s 2x2x10 s 2x2x12 s 2-2x12 s 3-2x12 s 3-2x12 s 7 2-2x6 s 2-2x8 s 2-2x8 s 2x2x10 s 2x2x10 s 2x2x12 s 2x2x12 s 3-2x12 s 3-2x12 s 3-2x12 s JOIST SPAN 8 2-2x6 s 2-2x8 s 2-2x8 s 2x2x10 s 2x2x12 s 2-2x12 s 3-2x12 s 3-2x12 s 3-2x12 s 9 2-2x6 s 2-2x8 s 2-2x10 s 2x2x10 s 2x2x12 s 3-2x12 s 3-2x12 s 3-2x12 s 10 2-2x8 s 2-2x8 s 2x2x10 s 2-2x12 s 2-2x12 s 3-2x12 s 3-2x12 s 11 2-2x8 s 2-2x10 s 2x2x10 s 2-2x12 s 3-2x12 s 3-2x12 s 3-2x12 s 12 2-2x8 s 2-2x10 s 2x2x10 s 2-2x12 s 3-2x12 s 3-2x12 s 13 2-2x8 s 2-2x10 s 2x2x12 s 2-2x12 s 3-2x12 s 3-2x12 s 14 2-2x8 s 2x2x10 s 2x2x12 s 3-2x12 s 3-2x12 s This area to be sized by Design Professional 15 2-2x10 s 2x2x10 s 2-2x12 s 3-2x12 s 3-2x12 s 16 2-2x10 s 2x2x10 s 2-2x12 s 3-2x12 s 3-2x12 s This is for beams with joists on one side NOT interior beams JOIST SPAN TABLE AND ON-CENTER SPACING 45psf Ground Snow Load SPACED AT 12 INCHES SPACED AT 16 INCHES SPACED AT 24 INCHES FEET MIN. SIZE FEET MIN. SIZE FEET MIN. SIZE 6 2 x 6 6 2 x 6 6 2 x 6 7 2 x 6 7 2 x 6 7 2 x 8 8 2 x 6 8 2 x 8 8 2 x 8 9 2 x 8 9 2 x 8 9 2 x 10 10 2 x 8 10 2 x 8 10 2 x 10 11 2 x 8 11 2 x 10 11 2 x 12 12 2 x 10 12 2 x 10 12 2 x 12 13 2 x 10 13 2 x 10 13 ** 14 2 x 10 14 2 x 12 14 ** 15 2 x 12 15 2 x 12 15 ** 16 2 x 12 16 ** 16 ** NOTES: Neither table addresses multiple spans All calculations based on Hem-Fir #2 Firewood storage and/or hot tubs are not permitted using these tables All beams must be fully supported Lumber must be protected from exterior elements Cantilevers not exceeding 1 foot can be included in overall joist span **To be sized by Design Professional CANTILEVER Larimer County Deck Handout does not apply to these deck designs. They must be designed by others to accepted engineering standards. MULTIPLE SPAN

DECK BEAM SPAM (Based on 70 psf Ground Snow Load & 10 psf Dead Load for elevations below 6001 to 8000 ) 6 7 8 9 10 11 12 13 14 15 4 2-2x6 s 2-2x6 s 2-2x8 s 2-2x8 s 2-2x8 s 2-2x10 s 2-2x10 s 2x2x12 s 2x2x12 s 3-2x12 s 5 2-2x6 s 2-2x6 s 2-2x8 s 2-2x8 s 2-2x10 s 2-2x10 s 2-2x12 s 2x2x12 s 3x2x12 s 3-2x12 s 6 2-2x6 s 2-2x8 s 2-2x8 s 2-2x10 s 2-2x10 s 2x2x12 s 3x2x12 s 3-2x12 s 3-2x12 s 7 2-2x6 s 2-2x8 s 2-2x10 s 2x2x10 s 2x2x12 s 2x2x12 s 3x2x12 s 3-2x12 s JOIST SPAN 8 2-2x8 s 2-2x8 s 2-2x10 s 2x2x12 s 2x2x12 s 3-2x12 s 3-2x12 s 9 2-2x8 s 2-2x10 s 2-2x10 s 2x2x12 s 3x2x12 s 3-2x12 s 10 2-2x8 s 2-2x10 s 2x2x12 s 2-2x12 s 3-2x12 s 3-2x12 s 11 2-2x8 s 2-2x10 s 2x2x12 s 3-2x12 s 3-2x12 s 12 2-2x10 s 2-2x10 s 2x2x12 s 3-2x12 s 3-2x12 s 13 2-2x10 s 2-2x12 s 2x2x12 s 3-2x12 s 14 2-2x10 s 2x2x12 s 3x2x12 s 3-2x12 s This area to be sized by Design Professional 15 2-2x10 s 2x2x12 s 3-2x12 s 3-2x12 s 16 2-2x10 s 2x2x12 s 3-2x12 s This is for beams with joists on one side NOT interior beams JOIST SPAN TABLE AND ON-CENTER SPACING 70 psf Ground Snow Load SPACED AT 12 INCHES SPACED AT 16 INCHES SPACED AT 24 INCHES FEET MIN. SIZE FEET MIN. SIZE FEET MIN. SIZE 6 2 x 6 6 2 x 6 6 2 x 6 7 2 x 6 7 2 x 6 7 2 x 8 8 2 x 8 8 2 x 8 8 2 x 10 9 2 x 8 9 2 x 8 9 2 x 10 10 2 x 8 10 2 x 10 10 2 x 12 11 2 x 10 11 2 x 10 11 2 x 12 12 2 x 10 12 2 x 12 12 ** 13 2 x 10 13 2 x 12 13 ** 14 2 x 12 14 ** 14 ** 15 2 x 12 15 ** 15 ** 16 ** 16 ** 16 ** **To be sized by Design Professional NOTES: Neither table addresses multiple spans All calculations based on Hem-Fir #2 Firewood storage and/or hot tubs are not permitted using these tables All beams must be fully supported Lumber must be protected from exterior elements Cantilevers not exceeding 1 foot can be included in overall joist span CANTILEVER Larimer County Deck Handout does not apply to these deck designs. They must be designed by others to accepted engineering standards. MULTIPLE SPAN

ELEVATION DETAIL Guardrails 36 min. height See attached table for prescriptive footing size. Justification of design professional required if assuming greater than 1500 PSF load bearing value of soil in Class C Roof Area or 2500 PSF in Class B Roof Area Frost depth required is 30 min. below grade unless solid rock is encountered. If rock is encountered within 30, a #4 rebar 12 long shall be doweled 6 into rock and epoxied (or per engineered plans). PLAN VIEW Posts must be treated if within 8 of grade. EXISTING RESIDENCE SHOW JOIST SIZE & SPACING INDICATE BEAM SIZE & SPAN SEE LEDGER DETAIL BELOW EXISTING SIDING TO BE REMOVED FOR NEW LEDGER BOARD ATTACHMENT Z-FLASHING 26 GAGE GALVANIZED METAL DECK JOIST JOIST HANGER (USE NON-CORROSIVE FASTENERS AS SPECIFICED BY HANGER MANUFACTURER) LEDGER CONNECTION DETAIL EXISTING FOUNDATION EXISTING FRAME WORK EXISTING FLOOR JOIST EXISTING RIM JOIST 1/2 LAG BOLTS OR LAG SCREWS AT 16 ON CENTER OR 5/16 LEDGERLOKS PER MANUFACTURER S SPECIFICATIONS (WHICH MUST FULLY PENETRATE THROUGH THE RIM BOARD). REFER TO ATTACHED TABLE FOR QUANTITY.

LEDGER ATTACHMENT ½ Diameter Lag Screws or LedgerLOKs DECK JOIST SPAN GROUND SNOW LOAD 6 & Less 6 1 8 8 1 10 10 1 12 12 1-14 14 1-16 45 PSF 2 2 3 3 4 4 70 PSF 2 3 3 4 4 5 DECK LATERAL ATTACHMENT DETAIL PER 2018 IRC FIGURE R507.9.2(2)