PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Similar documents
PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Digital Multifunction Instrument - Rish Master 3440

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Technical Data Sheet. x1000. kwh R Y B

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Data Sheet. RISH Master Record %THD

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Technical Data Sheet AMIK 300 / 301

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

EM-72 Electricity Meters for Current Transformers

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Power Meter Series PM3200 Functions and characteristics

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

AMIK 200 / 201 Technical Data Sheet

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Power Meter Series PM9

DIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Integra 1560 and 1580 Digital Transducer Systems

Monitoring Electric Network Via Internet

3-phase meter with direct connection and pulse or Modbus RS485 output

AMIK Three Phase Digital Panel Meters

RS Pro ENGLISH. Datasheet

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

RS Pro ENGLISH. Datasheet

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

N. TEST TEST DESCRIPTION

PEM353. Universal measuring device

Technical Data Sheet

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Single phase meter with direct connection and pulse or Modbus RS485 output

DIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

N. TEST TEST DESCRIPTION

Applications. diris_581_e_1_gb_cat

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM111

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

Installation and Operating Instructions

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm

Energy Management Energy Analyzer Type EM280-72D

Energy Management Energy Analyzer Type EM270-72D

 Applications DIRIS A40 DIRIS A40 DIRIS A40. diris_581_e_1_gb_cat

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Jewell DPM EINE BEST IN CLASS

PLA 33. Power line analyzer. User and service manual. version 2.4

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Energy Management Energy Meter Type EM340

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Centrale de mesure Power Meter PM500 Merlin Gerin

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Introduction DIN rail mounted electricity meters

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Power Quality and Energy Measurement PEM533

Energy Management Energy Meter Type EM110

Energy Management Energy Analyzer Type EM210 MID

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management Energy Analyzer Type EM210

ME432 Three-phase Power Meter

Alpha 50. Technical Data Sheet. Special Features

Energy Management Energy Meter Type EM21 72R Retro-Fit

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Applications. diris_581_d_1_gb_cat. Multimeasurement. Currents

MID energy meter B21 Single-phase energy meter, 65 A

Power Quality and Energy Measurement PEM575

Energy Management Compact Power Transducer Type CPT-DIN Basic version

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Energy Management Energy Meter GM3T E GM3T-RS485 E

Power Quality and Energy Measurement PEM735

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Application: Salient Features: Products Features:

ZHUHAI PILOT TECHNOLOGY CO., LTD.

Transcription:

RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module) Single phase or three phase network compatible True RMS measurement High definition white backlit LCD display Auto or manual page scrolling Daisy chaining up to 32 meters from one supply Programmable voltage and current transformer ratio MID BD Certified (Cert. o. : TCM 221/15xxxx) Simple programming & operation (auto or manual page scroll) Pulse output, Modbus and Mbus communication options Product Description Displayed Parameters The RIF300 is part of the easywire family of meters. The easywire system has been designed to save up to 90% installation time compared to a standard meter and current transformer installation. These MID approved multifunction energy meters are suitable for monitoring energy consumption and many other electrical parameters in industrial and commercial applications. These meters may be used in single or three phase applications. A high efficiency white backlit LCD display provides clear indication of measured values in all light conditions. Quick select pushbuttons on the front of the meter allow the user fast access to the display page required. The meter is available in three versions: With single pulse output. With single pulse output and Modbus communication. With single pulse output and Mbus communication. The unit is housed in a compact DI 96 case suitable for panel mounting. MID MID APPROVED FOR BILLIG APPLICATIOS Measuring Instruments Directive Voltage LL, L and average Current Phase, total and Max. demand Power Factor per phase and average Total Harmonic Distortion Current and Voltage eutral current (calculated) Frequency Hours Run Hours & minutes Power Active, Reactive and Apparent (per phase and total) Power Min./Max. demand Active, reactive and apparent. Energy Active, reactive and apparent (per phase and total) Import and export energy Active, Reactive and Apparent (per phase and total) www.rayleigh.com 1

Display Display Type Digit height Page scrolling High definition white backlit LCD 11.2mm (displayed parameter) 6.35mm (lowest 8 digits) Manual by front key / or auto scroll mode Displayed parameters and accuracies Voltage 0.5% of full scale Current 0.5% of full scale Frequency 0.1% of full scale (L >20V) Power factor 1% of unity Active power 1% Reactive power 1% Apparent power 1% Active Energy Class 1, Class B (IEC/E6205321, IEC/E50470) Reactive Energy Class 2 (IEC/E6205323) Total Harmonic Distortion (THD) 3% Energy maximum display 99999999 Resolution 0.01K, 0.1K, 1K, 0.01M, 0.1M, 1M (depending on CT ratio & VT ratio) Programming Parameters that can be changed using programming menu Programming access Memory retention CT Primary current VT primary voltage VT secondary voltage Communication address Communication speed (Baud) Communication Parity Communication number of stop bits Backlight timeout period Demand period (for integration) Pulse output (kwh) Pulse duration Reset to Factory Default Reset Energy and Maximum Demand Reset Active Energy Reset Reactive Energy Reset Apparent Energy Reset Maximum Current Reset Maximum Active Power Reset Minimum Active Power Reset Maximum Reactive Power Reset Minimum Reactive Power Reset Maximum Apparent Power Password protected (user selectable) on volatile memory www.rayleigh.com 2

Input Connection Single phase (selectable, or CT connection), Three phase four wire Input voltage range 100 240V ±15% (L ) Voltage Rated Burden <6VA ( supply), <0.2VA ( and ) ominal current input easywire input 330mV Max current (Imax) easywire input 396mV (ominal x 1.2) Current Rated Burden Starting current /A (easywire input) 0.4% of nominal Short time overcurrent 30 x Imax to IEC/E6205321 23 Impulse voltage withstand 6kV 1.2/50µS 0.5J AC voltage withstand CT primary current VT primary voltage Frequency 4kV 50Hz for 1 min 1A 10000A 100 500KV 45 65Hz Auxiliary Supply Voltage range Operating frequency Power consumption Selfsupplied from measuring input See input section See input section Outputs Energy pulses umber of pulse outputs 1 Pulse output function Pulse output type Pulse output Max. current Pulse output voltage range Pulse duration Pulse resolution kwh Semiconductor (does not support voltfree operation) 100mA 5 27Vdc 100ms 2s 0.01K, 0.1K, 1K, 0.01M, 0.1M, 1M (depending on CT ratio & VT ratio) Communication Communication type Communication protocol Modbus (Mbus upon request) Address 1 255 umber of bits 8bits Parity one, odd, even Baud rate 300, 600, 1200, 2400, 4800, 9600, 19200 Required response time to request 100ms umber of meters connected on the bus 32 (up to 255 with repeater) Max distance from Master device 500M www.rayleigh.com 3

Insulation Installation category III Pollution degree 2 Insulation voltage rating 300V (L ) Environmental Conditions Reference temperature Specified temperature operating range Storage temperature Relative humidity 23 C ±2 C 10 C 55 C 20 C 70 C 0 85%, noncondensing Mechanical Housing Housing Mounting Tamper sealing Housing material Protection degree (IEC/E60529) DI96 Panel mounted (Max. panel thickness 6mm) Meter housing (by means of a tamper evident seal). Terminal covers are available Selfextinguishing polycarbonate (UL94 V0) IP20 (terminals), IP54 (front of housing) Weight <240g Termination Current input terminal type Max. wire size Voltage input terminal type RJ45 easywire input /A (easywire input) Output terminal type Output terminal type Conformity Electromagnetic compatibility IEC/E613261, IEC/E55011 Class A, IEC/E6100042, 3, 4, 5, 6, 8, 11, IEC/E504701/3 Accuracy and functionality Safety IEC/E504701/3, IEC/E6205321, IEC/E6205323, DIRECTIVE 2014/32/EU IEC/E61010, IEC/E504701 www.rayleigh.com 4

Wiring Diagrams ote: # All fuse types : 0.5A class CC UL type 0.5A fast acting 600V Single Phase Single Phase Single Phase CT Input Voltage Voltage Voltage LIE LIE LIE 3 Phase 4 Wire Voltage LIE Dimensions Front bezel Side view Panel cutout 99 90.5 91.5 99 50 91.5 6 Model Selection Table Communications Model Pulse output RIF300P Modbus and pulse output RIF300C MBus and pulse output RIF300MB www.rayleigh.com 5